Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -76,6 +76,8 @@ 76 76 ))) 77 77 78 78 ((( 79 + 80 + 79 79 **Interface for Model: LT22222-L:** 80 80 ))) 81 81 ... ... @@ -99,6 +99,8 @@ 99 99 ))) 100 100 101 101 ((( 104 + 105 + 102 102 **LoRa Spec:** 103 103 ))) 104 104 ... ... @@ -158,8 +158,6 @@ 158 158 ))) 159 159 * ((( 160 160 Packet engine up to 256 bytes with CRC. 161 - 162 - 163 163 ))) 164 164 165 165 == 1.3 Features == ... ... @@ -194,7 +194,6 @@ 194 194 * 1 x Counting Port 195 195 ))) 196 196 197 - 198 198 = 2. Power ON Device = 199 199 200 200 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -315,7 +315,6 @@ 315 315 * [1] RO1 relay channel is close and the RO1 LED is ON. 316 316 * [0] RO2 relay channel is open and RO2 LED is OFF; 317 317 318 - 319 319 **LT22222-L:** 320 320 321 321 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -478,6 +478,7 @@ 478 478 ))) 479 479 480 480 481 + 481 481 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 482 482 483 483 ... ... @@ -630,7 +630,6 @@ 630 630 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 631 631 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 632 632 633 - 634 634 **AT Command to set Trigger Condition**: 635 635 636 636 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -710,7 +710,6 @@ 710 710 711 711 * Each bits shows if the corresponding trigger has been configured. 712 712 713 - 714 714 **Example:** 715 715 716 716 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -722,7 +722,6 @@ 722 722 723 723 * Each bits shows which status has been trigger on this uplink. 724 724 725 - 726 726 **Example:** 727 727 728 728 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -734,7 +734,6 @@ 734 734 735 735 * Each bits shows which status has been trigger on this uplink. 736 736 737 - 738 738 **Example:** 739 739 740 740 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -776,7 +776,6 @@ 776 776 777 777 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 778 778 779 - 780 780 === 3.4.1 Common Commands === 781 781 782 782 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]