... ... @@ -230,13 +230,12 @@
230 230  
231 231  [[image:image-20220523172350-1.png||height="266" width="864"]]
232 232  
233 -
234 234  (((
235 235  The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN:
236 236  )))
237 237  
238 238  (((
239 -(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.
238 +**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller.
240 240  )))
241 241  
242 242  (((
... ... @@ -245,7 +245,6 @@
245 245  
246 246  [[image:1653297924498-393.png]]
247 247  
248 -
249 249  Input these keys in the LoRaWAN Server portal. Below is TTN screen shot:
250 250  
251 251  Add APP EUI in the application.
... ... @@ -259,7 +259,7 @@
259 259  
260 260  
261 261  (((
262 -(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
260 +**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
263 263  )))
264 264  
265 265  [[image:1653298044601-602.png||height="405" width="709"]]
... ... @@ -317,6 +317,7 @@
317 317  * [0] RO2 relay channel is open and RO2 LED is OFF;
318 318  
319 319  
318 +
320 320  **LT22222-L:**
321 321  
322 322  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -625,6 +625,7 @@
625 625  * **AT+MOD=1 ** **~-~->** The normal working mode
626 626  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
627 627  
627 +
628 628  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
629 629  
630 630  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
... ... @@ -631,6 +631,7 @@
631 631  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
632 632  
633 633  
634 +
634 634  **AT Command to set Trigger Condition**:
635 635  
636 636  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -711,6 +711,7 @@
711 711  * Each bits shows if the corresponding trigger has been configured.
712 712  
713 713  
715 +
714 714  **Example:**
715 715  
716 716  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -723,6 +723,7 @@
723 723  * Each bits shows which status has been trigger on this uplink.
724 724  
725 725  
728 +
726 726  **Example:**
727 727  
728 728  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -735,6 +735,7 @@
735 735  * Each bits shows which status has been trigger on this uplink.
736 736  
737 737  
741 +
738 738  **Example:**
739 739  
740 740  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -777,6 +777,7 @@
777 777  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
778 778  
779 779  
784 +
780 780  === 3.4.1 Common Commands ===