Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -235,7 +235,7 @@ 235 235 ))) 236 236 237 237 ((( 238 - (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.238 +**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller. 239 239 ))) 240 240 241 241 ((( ... ... @@ -244,7 +244,6 @@ 244 244 245 245 [[image:1653297924498-393.png]] 246 246 247 - 248 248 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 249 249 250 250 Add APP EUI in the application. ... ... @@ -258,7 +258,7 @@ 258 258 259 259 260 260 ((( 261 - (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.260 +**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 262 262 ))) 263 263 264 264 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -316,6 +316,7 @@ 316 316 * [0] RO2 relay channel is open and RO2 LED is OFF; 317 317 318 318 318 + 319 319 **LT22222-L:** 320 320 321 321 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -332,6 +332,7 @@ 332 332 ** DO1 LED is off in both case 333 333 334 334 335 + 335 335 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 336 336 337 337 ... ... @@ -624,6 +624,7 @@ 624 624 * **AT+MOD=1 ** **~-~->** The normal working mode 625 625 * **AT+ADDMOD6=1** **~-~->** Enable trigger 626 626 628 + 627 627 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 628 628 629 629 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type ... ... @@ -630,6 +630,7 @@ 630 630 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 631 631 632 632 635 + 633 633 **AT Command to set Trigger Condition**: 634 634 635 635 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -710,6 +710,7 @@ 710 710 * Each bits shows if the corresponding trigger has been configured. 711 711 712 712 716 + 713 713 **Example:** 714 714 715 715 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -722,6 +722,7 @@ 722 722 * Each bits shows which status has been trigger on this uplink. 723 723 724 724 729 + 725 725 **Example:** 726 726 727 727 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -734,6 +734,7 @@ 734 734 * Each bits shows which status has been trigger on this uplink. 735 735 736 736 742 + 737 737 **Example:** 738 738 739 739 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -776,6 +776,7 @@ 776 776 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 777 777 778 778 785 + 779 779 === 3.4.1 Common Commands === 780 780 781 781 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]