Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,6 +19,8 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -48,6 +48,7 @@ 48 48 49 49 ))) 50 50 53 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( ... ... @@ -76,6 +76,8 @@ 76 76 ))) 77 77 78 78 ((( 82 + 83 + 79 79 **Interface for Model: LT22222-L:** 80 80 ))) 81 81 ... ... @@ -99,6 +99,8 @@ 99 99 ))) 100 100 101 101 ((( 107 + 108 + 102 102 **LoRa Spec:** 103 103 ))) 104 104 ... ... @@ -159,6 +159,8 @@ 159 159 * ((( 160 160 Packet engine up to 256 bytes with CRC. 161 161 169 + 170 + 162 162 163 163 ))) 164 164 ... ... @@ -172,6 +172,8 @@ 172 172 * Firmware upgradable via program port 173 173 * Counting 174 174 184 + 185 + 175 175 == 1.4 Applications == 176 176 177 177 * Smart Buildings & Home Automation ... ... @@ -181,6 +181,8 @@ 181 181 * Smart Cities 182 182 * Smart Factory 183 183 195 + 196 + 184 184 == 1.5 Hardware Variants == 185 185 186 186 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -194,6 +194,7 @@ 194 194 * 1 x Counting Port 195 195 ))) 196 196 210 + 197 197 = 2. Power ON Device = 198 198 199 199 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -216,12 +216,9 @@ 216 216 217 217 ((( 218 218 In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 219 - 220 - 221 221 ))) 222 222 223 223 224 - 225 225 == 3.2 Example to join LoRaWAN network == 226 226 227 227 ((( ... ... @@ -230,12 +230,13 @@ 230 230 231 231 [[image:image-20220523172350-1.png||height="266" width="864"]] 232 232 244 + 233 233 ((( 234 234 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 235 235 ))) 236 236 237 237 ((( 238 - **(% style="color:blue" %)Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.250 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller. 239 239 ))) 240 240 241 241 ((( ... ... @@ -244,6 +244,7 @@ 244 244 245 245 [[image:1653297924498-393.png]] 246 246 259 + 247 247 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 248 248 249 249 Add APP EUI in the application. ... ... @@ -257,7 +257,7 @@ 257 257 258 258 259 259 ((( 260 - **(% style="color:blue" %)Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.273 +(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 261 261 ))) 262 262 263 263 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -315,8 +315,6 @@ 315 315 * [1] RO1 relay channel is close and the RO1 LED is ON. 316 316 * [0] RO2 relay channel is open and RO2 LED is OFF; 317 317 318 - 319 - 320 320 **LT22222-L:** 321 321 322 322 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -370,12 +370,7 @@ 370 370 ((( 371 371 ((( 372 372 **AT+MOD=2** 373 -))) 374 -))) 375 375 376 -(% class="box infomessage" %) 377 -((( 378 -((( 379 379 **ATZ** 380 380 ))) 381 381 ))) ... ... @@ -394,40 +394,15 @@ 394 394 ((( 395 395 ((( 396 396 **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 397 -))) 398 -))) 399 399 400 -(% class="box infomessage" %) 401 -((( 402 -((( 403 403 **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 404 -))) 405 -))) 406 406 407 -(% class="box infomessage" %) 408 -((( 409 -((( 410 410 **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 411 -))) 412 -))) 413 413 414 -(% class="box infomessage" %) 415 -((( 416 -((( 417 417 **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 418 -))) 419 -))) 420 420 421 -(% class="box infomessage" %) 422 -((( 423 -((( 424 424 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 425 -))) 426 -))) 427 427 428 -(% class="box infomessage" %) 429 -((( 430 -((( 431 431 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 432 432 ))) 433 433 ))) ... ... @@ -462,12 +462,7 @@ 462 462 ((( 463 463 ((( 464 464 **AT+MOD=3** 465 -))) 466 -))) 467 467 468 -(% class="box infomessage" %) 469 -((( 470 -((( 471 471 **ATZ** 472 472 ))) 473 473 ))) ... ... @@ -474,11 +474,10 @@ 474 474 475 475 ((( 476 476 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 477 - 478 - 479 479 ))) 480 480 481 481 456 + 482 482 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 483 483 484 484 ... ... @@ -513,20 +513,13 @@ 513 513 ((( 514 514 ((( 515 515 **AT+MOD=4** 516 -))) 517 -))) 518 518 519 -(% class="box infomessage" %) 520 -((( 521 -((( 522 522 **ATZ** 523 523 ))) 524 524 ))) 525 525 526 -((( 527 - 528 -))) 529 529 497 + 530 530 ((( 531 531 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 532 532 ))) ... ... @@ -540,33 +540,17 @@ 540 540 (% class="box infomessage" %) 541 541 ((( 542 542 ((( 543 -**AT+SETCNT=3,60 (set AVI Count to 60)** 544 -))) 545 -))) 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 546 546 547 -(% class="box infomessage" %) 548 -((( 549 -((( 550 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 551 -))) 552 -))) 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 553 553 554 -(% class="box infomessage" %) 555 -((( 556 -((( 557 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 558 -))) 559 -))) 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 560 560 561 -(% class="box infomessage" %) 562 -((( 563 -((( 564 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 565 565 ))) 566 566 ))) 567 567 568 568 569 - 570 570 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 571 571 572 572 ... ... @@ -600,12 +600,7 @@ 600 600 ((( 601 601 ((( 602 602 **AT+MOD=5** 603 -))) 604 -))) 605 605 606 -(% class="box infomessage" %) 607 -((( 608 -((( 609 609 **ATZ** 610 610 ))) 611 611 ))) ... ... @@ -626,16 +626,13 @@ 626 626 * **AT+MOD=1 ** **~-~->** The normal working mode 627 627 * **AT+ADDMOD6=1** **~-~->** Enable trigger 628 628 629 - 630 630 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 631 631 632 632 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 633 633 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 634 634 581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 635 635 636 - 637 -**AT Command to set Trigger Condition**: 638 - 639 639 (% style="color:#4f81bd" %)**Trigger base on voltage**: 640 640 641 641 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -670,7 +670,7 @@ 670 670 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 671 671 672 672 673 -**Downlink Command to set Trigger Condition:** 617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 674 674 675 675 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 676 676 ... ... @@ -713,8 +713,6 @@ 713 713 714 714 * Each bits shows if the corresponding trigger has been configured. 715 715 716 - 717 - 718 718 **Example:** 719 719 720 720 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -726,8 +726,6 @@ 726 726 727 727 * Each bits shows which status has been trigger on this uplink. 728 728 729 - 730 - 731 731 **Example:** 732 732 733 733 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -739,8 +739,6 @@ 739 739 740 740 * Each bits shows which status has been trigger on this uplink. 741 741 742 - 743 - 744 744 **Example:** 745 745 746 746 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -769,7 +769,6 @@ 769 769 ))) 770 770 771 771 772 - 773 773 == 3.4 Configure LT via AT or Downlink == 774 774 775 775 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -796,7 +796,7 @@ 796 796 797 797 Set device uplink interval. 798 798 799 -* AT Command: 736 +* (% style="color:#037691" %)**AT Command:** 800 800 801 801 (% class="box infomessage" %) 802 802 ((( ... ... @@ -806,7 +806,7 @@ 806 806 **Example: **AT+TDC=30000. Means set interval to 30 seconds 807 807 808 808 809 -* Downlink Payload (prefix 0x01): 746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 810 810 811 811 (% class="box infomessage" %) 812 812 ((( ... ... @@ -819,7 +819,7 @@ 819 819 820 820 Set work mode. 821 821 822 -* AT Command: 759 +* (% style="color:#037691" %)**AT Command:** 823 823 824 824 (% class="box infomessage" %) 825 825 ((( ... ... @@ -829,7 +829,7 @@ 829 829 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 830 830 831 831 832 -* Downlink Payload (prefix 0x0A): 769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 833 833 834 834 (% class="box infomessage" %) 835 835 ((( ... ... @@ -840,12 +840,12 @@ 840 840 841 841 ==== 3.4.2.3 Poll an uplink ==== 842 842 843 -* AT Command: 780 +* (% style="color:#037691" %)AT Command: 844 844 845 845 There is no AT Command to poll uplink 846 846 847 847 848 -* Downlink Payload (prefix 0x08): 785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 849 849 850 850 (% class="box infomessage" %) 851 851 ((( ... ... @@ -860,7 +860,7 @@ 860 860 861 861 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 862 862 863 -* AT Command: 800 +* (% style="color:#037691" %)AT Command: 864 864 865 865 (% class="box infomessage" %) 866 866 ((( ... ... @@ -872,7 +872,7 @@ 872 872 0: Disable Trigger Mode 873 873 874 874 875 -* Downlink Payload (prefix 0x0A 06): 812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 876 876 877 877 (% class="box infomessage" %) 878 878 ((( ... ... @@ -885,12 +885,12 @@ 885 885 886 886 Poll trigger settings, 887 887 888 -* AT Command: 825 +* (% style="color:#037691" %)AT Command: 889 889 890 890 There is no AT Command for this feature. 891 891 892 892 893 -* Downlink Payload (prefix 0x AB 06): 830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 894 894 895 895 (% class="box infomessage" %) 896 896 ((( ... ... @@ -903,7 +903,7 @@ 903 903 904 904 Enable Disable DI1/DI2/DI2 as trigger, 905 905 906 -* AT Command: 843 +* (% style="color:#037691" %)AT Command: 907 907 908 908 (% class="box infomessage" %) 909 909 ((( ... ... @@ -915,7 +915,7 @@ 915 915 916 916 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 917 917 918 -* Downlink Payload (prefix 0xAA 02): 855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 919 919 920 920 (% class="box infomessage" %) 921 921 ((( ... ... @@ -928,7 +928,7 @@ 928 928 929 929 Set DI1 or DI3(for LT-33222-L) trigger. 930 930 931 -* AT Command: 868 +* (% style="color:#037691" %)AT Command: 932 932 933 933 (% class="box infomessage" %) 934 934 ((( ... ... @@ -945,7 +945,7 @@ 945 945 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 946 946 947 947 948 -* Downlink Payload (prefix 0x09 01 ): 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 949 949 950 950 (% class="box infomessage" %) 951 951 ((( ... ... @@ -958,7 +958,7 @@ 958 958 959 959 Set DI2 trigger. 960 960 961 -* AT Command: 898 +* (% style="color:#037691" %)AT Command: 962 962 963 963 (% class="box infomessage" %) 964 964 ((( ... ... @@ -975,7 +975,7 @@ 975 975 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 976 976 977 977 978 -* Downlink Payload (prefix 0x09 02 ): 915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 979 979 980 980 (% class="box infomessage" %) 981 981 ((( ... ... @@ -988,7 +988,7 @@ 988 988 989 989 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 990 990 991 -* AT Command: 928 +* (% style="color:#037691" %)AT Command: 992 992 993 993 (% class="box infomessage" %) 994 994 ((( ... ... @@ -996,7 +996,7 @@ 996 996 ))) 997 997 998 998 999 -* Downlink Payload (prefix 0xAA 01 ): 936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 1000 1000 1001 1001 (% class="box infomessage" %) 1002 1002 ((( ... ... @@ -1009,7 +1009,7 @@ 1009 1009 1010 1010 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1011 1011 1012 -* AT Command: 949 +* (% style="color:#037691" %)AT Command: 1013 1013 1014 1014 (% class="box infomessage" %) 1015 1015 ((( ... ... @@ -1017,7 +1017,7 @@ 1017 1017 ))) 1018 1018 1019 1019 1020 -* Downlink Payload (prefix 0xAA 00 ): 957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 1021 1021 1022 1022 (% class="box infomessage" %) 1023 1023 ((( ... ... @@ -1030,7 +1030,7 @@ 1030 1030 1031 1031 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 1032 1032 1033 -* AT Command: 970 +* (% style="color:#037691" %)AT Command: 1034 1034 1035 1035 (% class="box infomessage" %) 1036 1036 ((( ... ... @@ -1038,7 +1038,7 @@ 1038 1038 ))) 1039 1039 1040 1040 1041 -* Downlink Payload (prefix 0xAC ): 978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 1042 1042 1043 1043 (% class="box infomessage" %) 1044 1044 ((( ... ... @@ -1049,12 +1049,12 @@ 1049 1049 1050 1050 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1051 1051 1052 -* AT Command: 989 +* (% style="color:#037691" %)AT Command: 1053 1053 1054 1054 There is no AT Command to control Digital Output 1055 1055 1056 1056 1057 -* Downlink Payload (prefix 0x02): 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 1058 1058 1059 1059 (% class="box infomessage" %) 1060 1060 ((( ... ... @@ -1083,12 +1083,12 @@ 1083 1083 1084 1084 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1085 1085 1086 -* AT Command: 1023 +* (% style="color:#037691" %)AT Command: 1087 1087 1088 1088 There is no AT Command to control Digital Output 1089 1089 1090 1090 1091 -* Downlink Payload (prefix 0xA9): 1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 1092 1092 1093 1093 (% class="box infomessage" %) 1094 1094 ((( ... ... @@ -1152,12 +1152,12 @@ 1152 1152 1153 1153 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1154 1154 1155 -* AT Command: 1092 +* (% style="color:#037691" %)AT Command: 1156 1156 1157 1157 There is no AT Command to control Relay Output 1158 1158 1159 1159 1160 -* Downlink Payload (prefix 0x03): 1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1161 1161 1162 1162 (% class="box infomessage" %) 1163 1163 ((( ... ... @@ -1182,12 +1182,12 @@ 1182 1182 1183 1183 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1184 1184 1185 -* AT Command: 1122 +* (% style="color:#037691" %)AT Command: 1186 1186 1187 1187 There is no AT Command to control Relay Output 1188 1188 1189 1189 1190 -* Downlink Payload (prefix 0x05): 1127 +* (% style="color:#037691" %)Downlink Payload (prefix 0x05): 1191 1191 1192 1192 (% class="box infomessage" %) 1193 1193 ((( ... ... @@ -1239,7 +1239,7 @@ 1239 1239 1240 1240 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1241 1241 1242 -* AT Command: 1179 +* (% style="color:#037691" %)AT Command: 1243 1243 1244 1244 (% class="box infomessage" %) 1245 1245 ((( ... ... @@ -1247,7 +1247,7 @@ 1247 1247 ))) 1248 1248 1249 1249 1250 -* Downlink Payload (prefix 0xA5): 1187 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA5): 1251 1251 1252 1252 (% class="box infomessage" %) 1253 1253 ((( ... ... @@ -1258,7 +1258,7 @@ 1258 1258 1259 1259 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1260 1260 1261 -* AT Command: 1198 +* (% style="color:#037691" %)AT Command: 1262 1262 1263 1263 (% class="box infomessage" %) 1264 1264 ((( ... ... @@ -1274,7 +1274,7 @@ 1274 1274 Bb cc dd ee: number to be set 1275 1275 1276 1276 1277 -* Downlink Payload (prefix 0xA8): 1214 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA8): 1278 1278 1279 1279 (% class="box infomessage" %) 1280 1280 ((( ... ... @@ -1287,7 +1287,7 @@ 1287 1287 1288 1288 Clear counting for counting mode 1289 1289 1290 -* AT Command: 1227 +* (% style="color:#037691" %)AT Command: 1291 1291 1292 1292 (% class="box infomessage" %) 1293 1293 ((( ... ... @@ -1294,7 +1294,7 @@ 1294 1294 **AT+CLRCOUNT ~/~/ clear all counting** 1295 1295 ))) 1296 1296 1297 -* Downlink Payload (prefix 0xA6): 1234 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA6): 1298 1298 1299 1299 (% class="box infomessage" %) 1300 1300 ((( ... ... @@ -1305,7 +1305,7 @@ 1305 1305 1306 1306 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1307 1307 1308 -* AT Command: 1245 +* (% style="color:#037691" %)AT Command: 1309 1309 1310 1310 (% class="box infomessage" %) 1311 1311 ((( ... ... @@ -1312,7 +1312,7 @@ 1312 1312 **AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1313 1313 ))) 1314 1314 1315 -* Downlink Payload (prefix 0xA7): 1252 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA7): 1316 1316 1317 1317 (% class="box infomessage" %) 1318 1318 ((( ... ... @@ -2015,8 +2015,16 @@ 2015 2015 ))) 2016 2016 2017 2017 ((( 2018 - 1955 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2019 2019 1957 +If the device is not shut down, but directly powered off. 1958 + 1959 +It will default that this is a power-off state. 1960 + 1961 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 1962 + 1963 +After restart, the status before power failure will be read from flash. 1964 + 2020 2020 = 6. Trouble Shooting = 2021 2021 ))) 2022 2022