... ... @@ -235,7 +235,7 @@
235 235  )))
236 236  
237 237  (((
238 -**(% style="color:blue" %)Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.
238 +**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller.
239 239  )))
240 240  
241 241  (((
... ... @@ -257,7 +257,7 @@
257 257  
258 258  
259 259  (((
260 -**(% style="color:blue" %)Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
260 +**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
261 261  )))
262 262  
263 263  [[image:1653298044601-602.png||height="405" width="709"]]
... ... @@ -275,8 +275,6 @@
275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 -
279 -
280 280  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
281 281  
282 282  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -284,8 +284,6 @@
284 284  [[image:image-20220523174024-3.png]]
285 285  
286 286  (((
287 -
288 -
289 289  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
290 290  )))
291 291  
... ... @@ -299,7 +299,6 @@
299 299  
300 300  For example if payload is: [[image:image-20220523175847-2.png]]
301 301  
302 -
303 303  **The value for the interface is:  **
304 304  
305 305  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -316,7 +316,6 @@
316 316  * [0] RO2 relay channel is open and RO2 LED is OFF;
317 317  
318 318  
319 -
320 320  **LT22222-L:**
321 321  
322 322  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -626,14 +626,11 @@
626 626  * **AT+MOD=1 ** **~-~->** The normal working mode
627 627  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
628 628  
629 -
630 630  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
631 631  
632 632  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
633 633  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
634 634  
635 -
636 -
637 637  **AT Command to set Trigger Condition**:
638 638  
639 639  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -647,7 +647,6 @@
647 647  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
648 648  
649 649  
650 -
651 651  (% style="color:#4f81bd" %)**Trigger base on current**:
652 652  
653 653  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -657,7 +657,6 @@
657 657  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
658 658  
659 659  
660 -
661 661  (% style="color:#4f81bd" %)**Trigger base on DI status**:
662 662  
663 663  DI status trigger Flag.
... ... @@ -664,13 +664,12 @@
664 664  
665 665  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
666 666  
667 -
668 668  **Example:**
669 669  
670 670  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
671 671  
672 672  
673 -**Downlink Command to set Trigger Condition:**
661 +**Downlink Command to set Trigger Condition**
674 674  
675 675  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
676 676  
... ... @@ -699,7 +699,6 @@
699 699  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
700 700  
701 701  
702 -
703 703  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
704 704  
705 705  MOD6 Payload : total 11 bytes payload
... ... @@ -713,8 +713,6 @@
713 713  
714 714  * Each bits shows if the corresponding trigger has been configured.
715 715  
716 -
717 -
718 718  **Example:**
719 719  
720 720  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -726,8 +726,6 @@
726 726  
727 727  * Each bits shows which status has been trigger on this uplink.
728 728  
729 -
730 -
731 731  **Example:**
732 732  
733 733  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -739,8 +739,6 @@
739 739  
740 740  * Each bits shows which status has been trigger on this uplink.
741 741  
742 -
743 -
744 744  **Example:**
745 745  
746 746  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -783,7 +783,6 @@
783 783  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
784 784  
785 785  
786 -
787 787  === 3.4.1 Common Commands ===
788 788  
789 789  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved