Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -322,6 +322,7 @@ 322 322 * [1] RO1 relay channel is close and the RO1 LED is ON. 323 323 * [0] RO2 relay channel is open and RO2 LED is OFF; 324 324 325 + 325 325 **LT22222-L:** 326 326 327 327 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -337,6 +337,8 @@ 337 337 ** DO1 is high in case there is load between DO1 and V+. 338 338 ** DO1 LED is off in both case 339 339 341 + 342 + 340 340 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 341 341 342 342 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. ... ... @@ -430,6 +430,7 @@ 430 430 ))) 431 431 432 432 436 + 433 433 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 434 434 435 435 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -474,6 +474,8 @@ 474 474 475 475 ))) 476 476 481 + 482 + 477 477 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 478 478 479 479 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -555,6 +555,7 @@ 555 555 ))) 556 556 557 557 564 + 558 558 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 559 559 560 560 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -599,6 +599,8 @@ 599 599 600 600 ))) 601 601 609 + 610 + 602 602 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 603 603 604 604 (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** ... ... @@ -722,6 +722,7 @@ 722 722 When device got this command, it will send the MOD6 payload. 723 723 724 724 734 + 725 725 === 3.3.7 Payload Decoder === 726 726 727 727 ((( ... ... @@ -730,6 +730,8 @@ 730 730 731 731 ))) 732 732 743 + 744 + 733 733 == 3.4 Configure LT via AT or Downlink == 734 734 735 735 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -742,11 +742,14 @@ 742 742 743 743 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 744 744 757 + 758 + 745 745 === 3.4.1 Common Commands === 746 746 747 747 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 748 748 749 749 764 + 750 750 === 3.4.2 Sensor related commands === 751 751 752 752 ==== 3.4.2.1 Set Transmit Interval ==== ... ... @@ -770,6 +770,7 @@ 770 770 ))) 771 771 772 772 788 + 773 773 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 774 774 775 775 Set work mode. ... ... @@ -791,6 +791,7 @@ 791 791 ))) 792 792 793 793 810 + 794 794 ==== 3.4.2.3 Poll an uplink ==== 795 795 796 796 * AT Command: ... ... @@ -807,6 +807,7 @@ 807 807 **Example**: 0x08FF, ask device to send an Uplink 808 808 809 809 827 + 810 810 ==== 3.4.2.4 Enable Trigger Mode ==== 811 811 812 812 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -830,6 +830,7 @@ 830 830 ))) 831 831 832 832 851 + 833 833 ==== 3.4.2.5 Poll trigger settings ==== 834 834 835 835 Poll trigger settings, ... ... @@ -846,6 +846,7 @@ 846 846 ))) 847 847 848 848 868 + 849 849 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 850 850 851 851 Enable Disable DI1/DI2/DI2 as trigger, ... ... @@ -869,6 +869,7 @@ 869 869 ))) 870 870 871 871 892 + 872 872 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 873 873 874 874 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -896,6 +896,7 @@ 896 896 ))) 897 897 898 898 920 + 899 899 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 900 900 901 901 Set DI2 trigger. ... ... @@ -923,6 +923,7 @@ 923 923 ))) 924 924 925 925 948 + 926 926 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 927 927 928 928 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -942,6 +942,7 @@ 942 942 ))) 943 943 944 944 968 + 945 945 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 946 946 947 947 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -961,6 +961,7 @@ 961 961 ))) 962 962 963 963 988 + 964 964 ==== 3.4.2.11 Trigger – Set minimum interval ==== 965 965 966 966 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. ... ... @@ -980,6 +980,7 @@ 980 980 ))) 981 981 982 982 1008 + 983 983 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 984 984 985 985 * AT Command: ... ... @@ -1012,6 +1012,7 @@ 1012 1012 ))) 1013 1013 1014 1014 1041 + 1015 1015 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1016 1016 1017 1017 * AT Command: ... ... @@ -1074,6 +1074,7 @@ 1074 1074 DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low 1075 1075 1076 1076 1104 + 1077 1077 === 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 1078 1078 1079 1079 * AT Command: ... ... @@ -1102,6 +1102,7 @@ 1102 1102 Device will upload a packet if downlink code executes successfully. 1103 1103 1104 1104 1133 + 1105 1105 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1106 1106 1107 1107 * AT Command: ... ... @@ -1152,6 +1152,7 @@ 1152 1152 Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO. 1153 1153 1154 1154 1184 + 1155 1155 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1156 1156 1157 1157 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] ... ... @@ -1171,6 +1171,7 @@ 1171 1171 ))) 1172 1172 1173 1173 1204 + 1174 1174 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1175 1175 1176 1176 * AT Command: ... ... @@ -1196,6 +1196,7 @@ 1196 1196 ))) 1197 1197 1198 1198 1230 + 1199 1199 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1200 1200 1201 1201 Clear counting for counting mode ... ... @@ -1215,6 +1215,7 @@ 1215 1215 ))) 1216 1216 1217 1217 1250 + 1218 1218 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1219 1219 1220 1220 * AT Command: ... ... @@ -1237,6 +1237,8 @@ 1237 1237 1238 1238 ))) 1239 1239 1273 + 1274 + 1240 1240 == 3.5 Integrate with Mydevice == 1241 1241 1242 1242 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1278,6 +1278,7 @@ 1278 1278 [[image:image-20220524094909-5.png||height="341" width="734"]] 1279 1279 1280 1280 1316 + 1281 1281 == 3.6 Interface Detail == 1282 1282 1283 1283 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === ... ... @@ -1287,6 +1287,7 @@ 1287 1287 [[image:1653356991268-289.png]] 1288 1288 1289 1289 1326 + 1290 1290 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1291 1291 1292 1292 ((( ... ... @@ -1401,6 +1401,7 @@ 1401 1401 ))) 1402 1402 1403 1403 1441 + 1404 1404 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1405 1405 1406 1406 NPN output: GND or Float. Max voltage can apply to output pin is 36v. ... ... @@ -1408,6 +1408,7 @@ 1408 1408 [[image:1653357531600-905.png]] 1409 1409 1410 1410 1449 + 1411 1411 === 3.6.4 Analog Input Interface === 1412 1412 1413 1413 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: ... ... @@ -1436,6 +1436,7 @@ 1436 1436 [[image:1653357648330-671.png||height="155" width="733"]] 1437 1437 1438 1438 1478 + 1439 1439 === 3.6.5 Relay Output === 1440 1440 1441 1441 (((