From version < 77.1 >
edited by Edwin Chen
on 2022/06/02 15:25
To version < 77.13 >
edited by Xiaoling
on 2022/06/10 08:39
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -11,6 +11,9 @@
11 11  
12 12  
13 13  
14 +
15 +
16 +
14 14  = 1.Introduction =
15 15  
16 16  == 1.1 What is LT Series I/O Controller ==
... ... @@ -48,6 +48,8 @@
48 48  == 1.2  Specifications ==
49 49  
50 50  (((
54 +
55 +
51 51  **Hardware System:**
52 52  )))
53 53  
... ... @@ -70,6 +70,7 @@
70 70  )))
71 71  )))
72 72  
78 +
73 73  (((
74 74  **Interface for Model: LT22222-L:**
75 75  )))
... ... @@ -93,6 +93,7 @@
93 93  Power Input 7~~ 24V DC. 
94 94  )))
95 95  
102 +
96 96  (((
97 97  **LoRa Spec:**
98 98  )))
... ... @@ -157,6 +157,8 @@
157 157  
158 158  )))
159 159  
167 +
168 +
160 160  == 1.3 Features ==
161 161  
162 162  * LoRaWAN Class A & Class C protocol
... ... @@ -167,6 +167,8 @@
167 167  * Firmware upgradable via program port
168 168  * Counting
169 169  
179 +
180 +
170 170  == 1.4  Applications ==
171 171  
172 172  * Smart Buildings & Home Automation
... ... @@ -176,6 +176,8 @@
176 176  * Smart Cities
177 177  * Smart Factory
178 178  
190 +
191 +
179 179  == 1.5 Hardware Variants ==
180 180  
181 181  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -189,6 +189,8 @@
189 189  * 1 x Counting Port
190 190  )))
191 191  
205 +
206 +
192 192  = 2. Power ON Device =
193 193  
194 194  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -200,6 +200,7 @@
200 200  [[image:1653297104069-180.png]]
201 201  
202 202  
218 +
203 203  = 3. Operation Mode =
204 204  
205 205  == 3.1 How it works? ==
... ... @@ -214,6 +214,8 @@
214 214  
215 215  )))
216 216  
233 +
234 +
217 217  == 3.2 Example to join LoRaWAN network ==
218 218  
219 219  (((
... ... @@ -255,6 +255,7 @@
255 255  [[image:1653298044601-602.png||height="405" width="709"]]
256 256  
257 257  
276 +
258 258  == 3.3 Uplink Payload ==
259 259  
260 260  There are five working modes + one interrupt mode on LT for different type application:
... ... @@ -266,6 +266,8 @@
266 266  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
267 267  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
268 268  
288 +
289 +
269 269  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
270 270  
271 271  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -301,6 +301,7 @@
301 301  * [1] RO1 relay channel is close and the RO1 LED is ON.
302 302  * [0] RO2 relay channel is open and RO2 LED is OFF;
303 303  
325 +
304 304  **LT22222-L:**
305 305  
306 306  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -316,6 +316,8 @@
316 316  ** DO1 is high in case there is load between DO1 and V+.
317 317  ** DO1 LED is off in both case
318 318  
341 +
342 +
319 319  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
320 320  
321 321  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
... ... @@ -409,6 +409,7 @@
409 409  )))
410 410  
411 411  
436 +
412 412  === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI ===
413 413  
414 414  **LT22222-L**: This mode the DI1 is used as a counting pin.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved