Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,6 +11,9 @@ 11 11 12 12 13 13 14 + 15 + 16 + 14 14 = 1.Introduction = 15 15 16 16 == 1.1 What is LT Series I/O Controller == ... ... @@ -48,6 +48,8 @@ 48 48 == 1.2 Specifications == 49 49 50 50 ((( 54 + 55 + 51 51 **Hardware System:** 52 52 ))) 53 53 ... ... @@ -70,6 +70,7 @@ 70 70 ))) 71 71 ))) 72 72 78 + 73 73 ((( 74 74 **Interface for Model: LT22222-L:** 75 75 ))) ... ... @@ -93,6 +93,7 @@ 93 93 Power Input 7~~ 24V DC. 94 94 ))) 95 95 102 + 96 96 ((( 97 97 **LoRa Spec:** 98 98 ))) ... ... @@ -157,6 +157,8 @@ 157 157 158 158 ))) 159 159 167 + 168 + 160 160 == 1.3 Features == 161 161 162 162 * LoRaWAN Class A & Class C protocol ... ... @@ -206,6 +206,7 @@ 206 206 [[image:1653297104069-180.png]] 207 207 208 208 218 + 209 209 = 3. Operation Mode = 210 210 211 211 == 3.1 How it works? == ... ... @@ -220,6 +220,8 @@ 220 220 221 221 ))) 222 222 233 + 234 + 223 223 == 3.2 Example to join LoRaWAN network == 224 224 225 225 ((( ... ... @@ -261,6 +261,7 @@ 261 261 [[image:1653298044601-602.png||height="405" width="709"]] 262 262 263 263 276 + 264 264 == 3.3 Uplink Payload == 265 265 266 266 There are five working modes + one interrupt mode on LT for different type application: ... ... @@ -272,6 +272,8 @@ 272 272 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 273 273 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 274 274 288 + 289 + 275 275 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 276 276 277 277 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -307,6 +307,7 @@ 307 307 * [1] RO1 relay channel is close and the RO1 LED is ON. 308 308 * [0] RO2 relay channel is open and RO2 LED is OFF; 309 309 325 + 310 310 **LT22222-L:** 311 311 312 312 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -322,6 +322,8 @@ 322 322 ** DO1 is high in case there is load between DO1 and V+. 323 323 ** DO1 LED is off in both case 324 324 341 + 342 + 325 325 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 326 326 327 327 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. ... ... @@ -610,6 +610,7 @@ 610 610 611 611 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 612 612 631 + 613 613 (% style="color:#4f81bd" %)**Trigger base on current**: 614 614 615 615 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -618,6 +618,7 @@ 618 618 619 619 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 620 620 640 + 621 621 (% style="color:#4f81bd" %)**Trigger base on DI status**: 622 622 623 623 DI status trigger Flag. ... ... @@ -721,7 +721,7 @@ 721 721 There are two kinds of Commands: 722 722 ))) 723 723 724 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands744 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 725 725 726 726 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 727 727 ... ... @@ -792,7 +792,7 @@ 792 792 793 793 ==== 3.4.2.4 Enable Trigger Mode ==== 794 794 795 -Use of trigger mode, please check [[ADDMOD6>> path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]815 +Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 796 796 797 797 * AT Command: 798 798 ... ... @@ -908,7 +908,7 @@ 908 908 909 909 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 910 910 911 -Set current trigger , base on AC port. See [[trigger mode>> path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]931 +Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 912 912 913 913 * AT Command: 914 914 ... ... @@ -921,19 +921,19 @@ 921 921 922 922 (% class="box infomessage" %) 923 923 ((( 924 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>> url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**944 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 925 925 ))) 926 926 927 927 928 928 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 929 929 930 -Set current trigger , base on AV port. See [[trigger mode>> url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]950 +Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 931 931 932 932 * AT Command: 933 933 934 934 (% class="box infomessage" %) 935 935 ((( 936 -**AT+AVLIM. See [[trigger mode>> url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**956 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 937 937 ))) 938 938 939 939 * Downlink Payload (prefix 0xAA 00 ): ... ... @@ -940,7 +940,7 @@ 940 940 941 941 (% class="box infomessage" %) 942 942 ((( 943 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>> url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] **963 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 944 944 ))) 945 945 946 946 ... ... @@ -1137,13 +1137,13 @@ 1137 1137 1138 1138 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1139 1139 1140 -When voltage exceed the threshold, count. Feature see [[MOD4>> path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]1160 +When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1141 1141 1142 1142 * AT Command: 1143 1143 1144 1144 (% class="box infomessage" %) 1145 1145 ((( 1146 -**AT+VOLMAX ~/~/ See [[MOD4>> path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]**1166 +**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1147 1147 ))) 1148 1148 1149 1149 * Downlink Payload (prefix 0xA5): ... ... @@ -1238,6 +1238,7 @@ 1238 1238 1239 1239 [[image:image-20220524094641-12.png||height="402" width="718"]] 1240 1240 1261 + 1241 1241 **Step 3**: Create an account or log in Mydevices. 1242 1242 1243 1243 **Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %) ... ... @@ -1861,6 +1861,11 @@ 1861 1861 ((( 1862 1862 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn’t support AT+DEBUG. User can update to latest firmware first. 1863 1863 1885 + 1886 +== 5.5 Can i use point to point communication for LT-22222-L? == 1887 + 1888 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1889 + 1864 1864 1865 1865 ))) 1866 1866