From version < 75.9 >
edited by Xiaoling
on 2022/06/01 17:28
To version < 75.15 >
edited by Xiaoling
on 2022/06/01 17:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -272,6 +272,8 @@
272 272  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
273 273  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
274 274  
275 +
276 +
275 275  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
276 276  
277 277  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -322,6 +322,8 @@
322 322  ** DO1 is high in case there is load between DO1 and V+.
323 323  ** DO1 LED is off in both case
324 324  
327 +
328 +
325 325  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
326 326  
327 327  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
... ... @@ -610,6 +610,7 @@
610 610  
611 611  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
612 612  
617 +
613 613  (% style="color:#4f81bd" %)**Trigger base on current**:
614 614  
615 615  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -618,6 +618,7 @@
618 618  
619 619  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
620 620  
626 +
621 621  (% style="color:#4f81bd" %)**Trigger base on DI status**:
622 622  
623 623  DI status trigger Flag.
... ... @@ -721,7 +721,7 @@
721 721  There are two kinds of Commands:
722 722  )))
723 723  
724 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
730 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
725 725  
726 726  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
727 727  
... ... @@ -792,7 +792,7 @@
792 792  
793 793  ==== 3.4.2.4 Enable Trigger Mode ====
794 794  
795 -Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
801 +Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
796 796  
797 797  * AT Command:
798 798  
... ... @@ -908,7 +908,7 @@
908 908  
909 909  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
910 910  
911 -Set current trigger , base on AC port. See [[trigger mode>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
917 +Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
912 912  
913 913  * AT Command:
914 914  
... ... @@ -921,19 +921,19 @@
921 921  
922 922  (% class="box infomessage" %)
923 923  (((
924 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
930 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
925 925  )))
926 926  
927 927  
928 928  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
929 929  
930 -Set current trigger , base on AV port. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
936 +Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
931 931  
932 932  * AT Command:
933 933  
934 934  (% class="box infomessage" %)
935 935  (((
936 -**AT+AVLIM. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
942 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
937 937  )))
938 938  
939 939  * Downlink Payload (prefix 0xAA 00 ):
... ... @@ -940,7 +940,7 @@
940 940  
941 941  (% class="box infomessage" %)
942 942  (((
943 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] **
949 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] **
944 944  )))
945 945  
946 946  
... ... @@ -1137,7 +1137,7 @@
1137 1137  
1138 1138  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1139 1139  
1140 -When voltage exceed the threshold, count. Feature see [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]
1146 +When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1141 1141  
1142 1142  * AT Command:
1143 1143  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0