Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,7 +16,7 @@ 16 16 == 1.1 What is LT Series I/O Controller == 17 17 18 18 ((( 19 -The Dragino (%style="color:blue" %)**LT series I/O Modules**(%%)are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (%style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %),**relay output**,**digital input**(%%)and(% style="color:blue" %)**digital output**(%%)etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring.19 +The Dragino LT series I/O Modules are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as: analog current Input, analog voltage input, relay output, digital input and digital output etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 20 20 ))) 21 21 22 22 ((( ... ... @@ -24,7 +24,7 @@ 24 24 ))) 25 25 26 26 ((( 27 -The LT I/O Controllers is aiming to provide a n (%style="color:blue"%)**easy and low cost installation**(%%)by using LoRa wireless technology.27 +The LT I/O Controllers is aiming to provide a simple plug and play, low cost installation by using LoRaWAN wireless technology. 28 28 ))) 29 29 30 30 ((( ... ... @@ -41,8 +41,6 @@ 41 41 42 42 ((( 43 43 [[image:1653295757274-912.png]] 44 - 45 - 46 46 ))) 47 47 48 48 == 1.2 Specifications == ... ... @@ -153,8 +153,6 @@ 153 153 ))) 154 154 * ((( 155 155 Packet engine up to 256 bytes with CRC. 156 - 157 - 158 158 ))) 159 159 160 160 == 1.3 Features == ... ... @@ -167,8 +167,6 @@ 167 167 * Firmware upgradable via program port 168 168 * Counting 169 169 170 - 171 - 172 172 == 1.4 Applications == 173 173 174 174 * Smart Buildings & Home Automation ... ... @@ -178,8 +178,6 @@ 178 178 * Smart Cities 179 179 * Smart Factory 180 180 181 - 182 - 183 183 == 1.5 Hardware Variants == 184 184 185 185 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -193,8 +193,6 @@ 193 193 * 1 x Counting Port 194 194 ))) 195 195 196 - 197 - 198 198 = 2. Power ON Device = 199 199 200 200 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -205,7 +205,6 @@ 205 205 206 206 [[image:1653297104069-180.png]] 207 207 208 - 209 209 = 3. Operation Mode = 210 210 211 211 == 3.1 How it works? == ... ... @@ -216,8 +216,6 @@ 216 216 217 217 ((( 218 218 In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 219 - 220 - 221 221 ))) 222 222 223 223 == 3.2 Example to join LoRaWAN network == ... ... @@ -248,12 +248,10 @@ 248 248 249 249 [[image:1653297955910-247.png||height="321" width="716"]] 250 250 251 - 252 252 Add APP KEY and DEV EUI 253 253 254 254 [[image:1653298023685-319.png]] 255 255 256 - 257 257 ((( 258 258 **Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 259 259 ))) ... ... @@ -260,7 +260,6 @@ 260 260 261 261 [[image:1653298044601-602.png||height="405" width="709"]] 262 262 263 - 264 264 == 3.3 Uplink Payload == 265 265 266 266 There are five working modes + one interrupt mode on LT for different type application: ... ... @@ -414,7 +414,6 @@ 414 414 ))) 415 415 ))) 416 416 417 - 418 418 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 419 419 420 420 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -455,8 +455,6 @@ 455 455 456 456 ((( 457 457 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 458 - 459 - 460 460 ))) 461 461 462 462 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === ... ... @@ -539,7 +539,6 @@ 539 539 ))) 540 540 ))) 541 541 542 - 543 543 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 544 544 545 545 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -580,8 +580,6 @@ 580 580 581 581 ((( 582 582 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 583 - 584 - 585 585 ))) 586 586 587 587 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === ... ... @@ -704,13 +704,10 @@ 704 704 705 705 When device got this command, it will send the MOD6 payload. 706 706 707 - 708 708 === 3.3.7 Payload Decoder === 709 709 710 710 ((( 711 711 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 712 - 713 - 714 714 ))) 715 715 716 716 == 3.4 Configure LT via AT or Downlink == ... ... @@ -729,7 +729,6 @@ 729 729 730 730 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 731 731 732 - 733 733 === 3.4.2 Sensor related commands === 734 734 735 735 ==== 3.4.2.1 Set Transmit Interval ==== ... ... @@ -752,7 +752,6 @@ 752 752 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 753 753 ))) 754 754 755 - 756 756 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 757 757 758 758 Set work mode. ... ... @@ -773,7 +773,6 @@ 773 773 **0x0A aa ~/~/ Same as AT+MOD=aa** 774 774 ))) 775 775 776 - 777 777 ==== 3.4.2.3 Poll an uplink ==== 778 778 779 779 * AT Command: ... ... @@ -789,7 +789,6 @@ 789 789 790 790 **Example**: 0x08FF, ask device to send an Uplink 791 791 792 - 793 793 ==== 3.4.2.4 Enable Trigger Mode ==== 794 794 795 795 Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] ... ... @@ -812,7 +812,6 @@ 812 812 **0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 813 813 ))) 814 814 815 - 816 816 ==== 3.4.2.5 Poll trigger settings ==== 817 817 818 818 Poll trigger settings, ... ... @@ -828,7 +828,6 @@ 828 828 **0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 829 829 ))) 830 830 831 - 832 832 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 833 833 834 834 Enable Disable DI1/DI2/DI2 as trigger, ... ... @@ -851,7 +851,6 @@ 851 851 **0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 852 852 ))) 853 853 854 - 855 855 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 856 856 857 857 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -878,7 +878,6 @@ 878 878 **0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 879 879 ))) 880 880 881 - 882 882 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 883 883 884 884 Set DI2 trigger. ... ... @@ -905,7 +905,6 @@ 905 905 **0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 906 906 ))) 907 907 908 - 909 909 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 910 910 911 911 Set current trigger , base on AC port. See [[trigger mode>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] ... ... @@ -924,7 +924,6 @@ 924 924 **0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]** 925 925 ))) 926 926 927 - 928 928 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 929 929 930 930 Set current trigger , base on AV port. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] ... ... @@ -943,7 +943,6 @@ 943 943 **0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] ** 944 944 ))) 945 945 946 - 947 947 ==== 3.4.2.11 Trigger – Set minimum interval ==== 948 948 949 949 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. ... ... @@ -962,7 +962,6 @@ 962 962 **0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 963 963 ))) 964 964 965 - 966 966 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 967 967 968 968 * AT Command: ... ... @@ -1153,7 +1153,6 @@ 1153 1153 **0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1154 1154 ))) 1155 1155 1156 - 1157 1157 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1158 1158 1159 1159 * AT Command: ... ... @@ -1178,7 +1178,6 @@ 1178 1178 **0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1179 1179 ))) 1180 1180 1181 - 1182 1182 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1183 1183 1184 1184 Clear counting for counting mode ... ... @@ -1197,7 +1197,6 @@ 1197 1197 **0x A6 01 ~/~/ clear all counting,** 1198 1198 ))) 1199 1199 1200 - 1201 1201 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1202 1202 1203 1203 * AT Command: ... ... @@ -1216,8 +1216,6 @@ 1216 1216 1217 1217 ((( 1218 1218 range: aa bb cc:0 to 16777215, (unit:second) 1219 - 1220 - 1221 1221 ))) 1222 1222 1223 1223 == 3.5 Integrate with Mydevice == ... ... @@ -1246,7 +1246,6 @@ 1246 1246 1247 1247 [[image:1653356838789-523.png||height="337" width="740"]] 1248 1248 1249 - 1250 1250 After added, the sensor data arrive TTN, it will also arrive and show in Mydevices. 1251 1251 1252 1252 [[image:image-20220524094909-1.png||height="335" width="729"]] ... ... @@ -1259,7 +1259,6 @@ 1259 1259 1260 1260 [[image:image-20220524094909-5.png||height="341" width="734"]] 1261 1261 1262 - 1263 1263 == 3.6 Interface Detail == 1264 1264 1265 1265 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === ... ... @@ -1268,7 +1268,6 @@ 1268 1268 1269 1269 [[image:1653356991268-289.png]] 1270 1270 1271 - 1272 1272 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1273 1273 1274 1274 ((( ... ... @@ -1284,105 +1284,51 @@ 1284 1284 [[image:1653357170703-587.png]] 1285 1285 1286 1286 ((( 1287 -((( 1288 1288 When use need to connect a device to the DI port, both DI1+ and DI1- must be connected. 1289 1289 ))) 1290 -))) 1291 1291 1292 -((( 1293 - 1294 -))) 1295 1295 1296 -((( 1297 1297 **Example1**: Connect to a Low active sensor. 1298 -))) 1299 1299 1300 -((( 1301 1301 This type of sensor will output a low signal GND when active. 1302 -))) 1303 1303 1304 -* ((( 1305 -Connect sensor’s output to DI1- 1306 -))) 1307 -* ((( 1308 -Connect sensor’s VCC to DI1+. 1309 -))) 1250 +* Connect sensor’s output to DI1- 1251 +* Connect sensor’s VCC to DI1+. 1310 1310 1311 -((( 1312 -So when sensor active, the current between NEC2501 pin1 and pin2 is: 1313 -))) 1253 +So when sensor active, the current between NEC2501 pin1 and pin2 is: 1314 1314 1315 -((( 1316 -[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 1K.** 1317 -))) 1255 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]** [[image:image-20220524095628-8.png]] = DI1+ / 1K.** 1318 1318 1319 -((( 1320 -If DI1+ = 12v, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal. 1321 -))) 1257 +If DI1+ = 12v, the //IF// = 12mA , So the LT-22222-L will be able to detect this active signal. 1322 1322 1323 -((( 1324 - 1325 -))) 1326 1326 1327 -((( 1328 1328 **Example2**: Connect to a High active sensor. 1329 -))) 1330 1330 1331 -((( 1332 1332 This type of sensor will output a high signal (example 24v) when active. 1333 -))) 1334 1334 1335 -* ((( 1336 -Connect sensor’s output to DI1+ 1337 -))) 1338 -* ((( 1339 -Connect sensor’s GND DI1-. 1340 -))) 1264 +* Connect sensor’s output to DI1+ 1265 +* Connect sensor’s GND DI1-. 1341 1341 1342 -((( 1343 1343 So when sensor active, the current between NEC2501 pin1 and pin2 is: 1344 -))) 1345 1345 1346 -((( 1347 -[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 1K.** 1348 -))) 1269 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]** [[image:image-20220524095628-8.png]]= DI1+ / 1K.** 1349 1349 1350 -((( 1351 -If **DI1+ = 24v**, the[[image:1653968155772-850.png||height="23" width="19"]] 24mA , So the LT-22222-L will be able to detect this high active signal. 1352 -))) 1271 +If **DI1+ = 24v**, the [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]]** = 24mA , So the LT-22222-L will be able to detect this high active signal. 1353 1353 1354 -((( 1355 - 1356 -))) 1357 1357 1358 -((( 1359 1359 **Example3**: Connect to a 220v high active sensor. 1360 -))) 1361 1361 1362 -((( 1363 1363 Assume user want to monitor an active signal higher than 220v, to make sure not burn the photocoupler 1364 -))) 1365 1365 1366 -* ((( 1367 -Connect sensor’s output to DI1+ with a serial 50K resistor 1368 -))) 1369 -* ((( 1370 -Connect sensor’s GND DI1-. 1371 -))) 1278 +* Connect sensor’s output to DI1+ with a serial 50K resistor 1279 +* Connect sensor’s GND DI1-. 1372 1372 1373 -((( 1374 1374 So when sensor active, the current between NEC2501 pin1 and pin2 is: 1375 -))) 1376 1376 1377 -((( 1378 - [[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 51K.** 1379 -))) 1283 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]] = DI1+ / 51K.** 1380 1380 1381 -((( 1382 -If sensor output is 220v, the [[image:1653968155772-850.png||height="23" width="19"]](% id="cke_bm_243359S" style="display:none" %)[[image:image-20220524095628-8.png]](%%) = DI1+ / 51K. = 4.3mA , So the LT-22222-L will be able to detect this high active signal safely. 1383 -))) 1285 +If sensor output is 220v, the (% id="cke_bm_243359S" style="display:none" %)[[image:image-20220524095628-8.png]](%%) = DI1+ / 51K. = 4.3mA , So the LT-22222-L will be able to detect this high active signal safely. 1384 1384 1385 - 1386 1386 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1387 1387 1388 1388 NPN output: GND or Float. Max voltage can apply to output pin is 36v. ... ... @@ -1389,7 +1389,6 @@ 1389 1389 1390 1390 [[image:1653357531600-905.png]] 1391 1391 1392 - 1393 1393 === 3.6.4 Analog Input Interface === 1394 1394 1395 1395 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: ... ... @@ -1417,7 +1417,6 @@ 1417 1417 1418 1418 [[image:1653357648330-671.png||height="155" width="733"]] 1419 1419 1420 - 1421 1421 === 3.6.5 Relay Output === 1422 1422 1423 1423 ((( ... ... @@ -1428,12 +1428,10 @@ 1428 1428 1429 1429 [[image:image-20220524100215-10.png||height="382" width="723"]] 1430 1430 1431 - 1432 1432 == 3.7 LEDs Indicators == 1433 1433 1434 1434 [[image:image-20220524100748-11.png]] 1435 1435 1436 - 1437 1437 = 4. Use AT Command = 1438 1438 1439 1439 == 4.1 Access AT Command == ... ... @@ -1634,8 +1634,6 @@ 1634 1634 1635 1635 ((( 1636 1636 AT+CFG: Print all settings 1637 - 1638 - 1639 1639 ))) 1640 1640 1641 1641 == 4.2 Common AT Command Sequence == ... ... @@ -1677,8 +1677,6 @@ 1677 1677 1678 1678 ((( 1679 1679 (% style="background-color:#dcdcdc" %)ATZ 1680 - 1681 - 1682 1682 ))) 1683 1683 1684 1684 === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) === ... ... @@ -1760,7 +1760,6 @@ 1760 1760 (% style="background-color:#dcdcdc" %)AT+CLASS=A 1761 1761 ATZ 1762 1762 1763 - 1764 1764 = 5. FAQ = 1765 1765 1766 1766 == 5.1 How to upgrade the image? == ... ... @@ -1791,7 +1791,6 @@ 1791 1791 1792 1792 [[image:1653360054704-518.png||height="186" width="745"]] 1793 1793 1794 - 1795 1795 ((( 1796 1796 ((( 1797 1797 == 5.2 How to change the LoRa Frequency Bands/Region? == ... ... @@ -1800,8 +1800,6 @@ 1800 1800 1801 1801 ((( 1802 1802 User can follow the introduction for [[how to upgrade image>>||anchor="H5.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. 1803 - 1804 - 1805 1805 ))) 1806 1806 1807 1807 ((( ... ... @@ -1855,13 +1855,10 @@ 1855 1855 1856 1856 [[image:1653360498588-932.png||height="485" width="726"]] 1857 1857 1858 - 1859 1859 == 5.4 Can I see counting event in Serial? == 1860 1860 1861 1861 ((( 1862 1862 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn’t support AT+DEBUG. User can update to latest firmware first. 1863 - 1864 - 1865 1865 ))) 1866 1866 1867 1867 ((( ... ... @@ -1875,8 +1875,10 @@ 1875 1875 ))) 1876 1876 1877 1877 ((( 1878 -Please see this link for how to debug: [[LoRaWANCommunication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H5.1Howitwork"]]1764 +Please see this link for how to debug: 1879 1879 1766 +[[http:~~/~~/wiki1.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H5.1Howitwork>>http://wiki1.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H5.1Howitwork]] 1767 + 1880 1880 1881 1881 ))) 1882 1882 ... ... @@ -1885,7 +1885,9 @@ 1885 1885 ))) 1886 1886 1887 1887 ((( 1888 -See this link for trouble shooting: [[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]] 1776 +See this link for trouble shooting: 1777 + 1778 +[[http:~~/~~/wiki1.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/>>http://wiki1.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]] 1889 1889 ))) 1890 1890 1891 1891 ((( ... ... @@ -1897,7 +1897,9 @@ 1897 1897 ))) 1898 1898 1899 1899 ((( 1900 -It might be about the channels mapping. [[Please see this link for detail>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1790 +It might be about the channels mapping. Please see this link for detail: 1791 + 1792 +[[http:~~/~~/wiki1.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband>>http://wiki1.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]] 1901 1901 ))) 1902 1902 1903 1903 ((( ... ... @@ -1971,8 +1971,6 @@ 1971 1971 ((( 1972 1972 * ((( 1973 1973 (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 1974 - 1975 - 1976 1976 ))) 1977 1977 1978 1978 = 8. Packing Info = ... ... @@ -2005,8 +2005,6 @@ 2005 2005 * Device Weight: 105g 2006 2006 * Package Size / pcs : 14.5 x 8 x 5 cm 2007 2007 * Weight / pcs : 170g 2008 - 2009 - 2010 2010 ))) 2011 2011 ))) 2012 2012 ... ... @@ -2028,8 +2028,6 @@ 2028 2028 ((( 2029 2029 ((( 2030 2030 [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 2031 - 2032 - 2033 2033 ))) 2034 2034 2035 2035 (((
- 1653968155772-850.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -886 bytes - Content
- 1653968164738-884.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -886 bytes - Content
- 1653968172068-832.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -886 bytes - Content
- image-20220531113415-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -172 bytes - Content