Last modified by Mengting Qiu on 2025/06/04 18:42

From version 75.8
edited by Xiaoling
on 2022/06/01 17:28
Change comment: There is no comment for this version
To version 77.39
edited by Xiaoling
on 2022/06/10 08:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,6 +11,9 @@
11 11  
12 12  
13 13  
14 +
15 +
16 +
14 14  = 1.Introduction =
15 15  
16 16  == 1.1 What is LT Series I/O Controller ==
... ... @@ -48,6 +48,8 @@
48 48  == 1.2  Specifications ==
49 49  
50 50  (((
54 +
55 +
51 51  **Hardware System:**
52 52  )))
53 53  
... ... @@ -157,6 +157,7 @@
157 157  
158 158  )))
159 159  
165 +
160 160  == 1.3 Features ==
161 161  
162 162  * LoRaWAN Class A & Class C protocol
... ... @@ -168,7 +168,6 @@
168 168  * Counting
169 169  
170 170  
171 -
172 172  == 1.4  Applications ==
173 173  
174 174  * Smart Buildings & Home Automation
... ... @@ -179,7 +179,6 @@
179 179  * Smart Factory
180 180  
181 181  
182 -
183 183  == 1.5 Hardware Variants ==
184 184  
185 185  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -193,6 +193,7 @@
193 193  * 1 x Counting Port
194 194  )))
195 195  
200 +
196 196  = 2. Power ON Device =
197 197  
198 198  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -204,6 +204,7 @@
204 204  [[image:1653297104069-180.png]]
205 205  
206 206  
212 +
207 207  = 3. Operation Mode =
208 208  
209 209  == 3.1 How it works? ==
... ... @@ -218,6 +218,8 @@
218 218  
219 219  )))
220 220  
227 +
228 +
221 221  == 3.2 Example to join LoRaWAN network ==
222 222  
223 223  (((
... ... @@ -259,6 +259,7 @@
259 259  [[image:1653298044601-602.png||height="405" width="709"]]
260 260  
261 261  
270 +
262 262  == 3.3 Uplink Payload ==
263 263  
264 264  There are five working modes + one interrupt mode on LT for different type application:
... ... @@ -270,6 +270,7 @@
270 270  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
271 271  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
272 272  
282 +
273 273  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
274 274  
275 275  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -320,6 +320,7 @@
320 320  ** DO1 is high in case there is load between DO1 and V+.
321 321  ** DO1 LED is off in both case
322 322  
333 +
323 323  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
324 324  
325 325  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
... ... @@ -413,6 +413,7 @@
413 413  )))
414 414  
415 415  
427 +
416 416  === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI ===
417 417  
418 418  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -457,6 +457,8 @@
457 457  
458 458  )))
459 459  
472 +
473 +
460 460  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
461 461  
462 462  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -538,6 +538,7 @@
538 538  )))
539 539  
540 540  
555 +
541 541  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
542 542  
543 543  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -582,6 +582,8 @@
582 582  
583 583  )))
584 584  
600 +
601 +
585 585  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
586 586  
587 587  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
... ... @@ -608,6 +608,7 @@
608 608  
609 609  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
610 610  
628 +
611 611  (% style="color:#4f81bd" %)**Trigger base on current**:
612 612  
613 613  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -616,6 +616,7 @@
616 616  
617 617  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
618 618  
637 +
619 619  (% style="color:#4f81bd" %)**Trigger base on DI status**:
620 620  
621 621  DI status trigger Flag.
... ... @@ -703,6 +703,7 @@
703 703  When device got this command, it will send the MOD6 payload.
704 704  
705 705  
725 +
706 706  === 3.3.7 Payload Decoder ===
707 707  
708 708  (((
... ... @@ -711,6 +711,8 @@
711 711  
712 712  )))
713 713  
734 +
735 +
714 714  == 3.4 ​Configure LT via AT or Downlink ==
715 715  
716 716  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
... ... @@ -719,15 +719,17 @@
719 719  There are two kinds of Commands:
720 720  )))
721 721  
722 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
744 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
723 723  
724 724  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
725 725  
748 +
726 726  === 3.4.1 Common Commands ===
727 727  
728 728  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
729 729  
730 730  
754 +
731 731  === 3.4.2 Sensor related commands ===
732 732  
733 733  ==== 3.4.2.1 Set Transmit Interval ====
... ... @@ -751,6 +751,7 @@
751 751  )))
752 752  
753 753  
778 +
754 754  ==== 3.4.2.2 Set Work Mode (AT+MOD) ====
755 755  
756 756  Set work mode.
... ... @@ -772,6 +772,7 @@
772 772  )))
773 773  
774 774  
800 +
775 775  ==== 3.4.2.3 Poll an uplink ====
776 776  
777 777  * AT Command:
... ... @@ -788,9 +788,10 @@
788 788  **Example**: 0x08FF, ask device to send an Uplink
789 789  
790 790  
817 +
791 791  ==== 3.4.2.4 Enable Trigger Mode ====
792 792  
793 -Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
820 +Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
794 794  
795 795  * AT Command:
796 796  
... ... @@ -811,6 +811,7 @@
811 811  )))
812 812  
813 813  
841 +
814 814  ==== 3.4.2.5 Poll trigger settings ====
815 815  
816 816  Poll trigger settings,
... ... @@ -827,6 +827,7 @@
827 827  )))
828 828  
829 829  
858 +
830 830  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
831 831  
832 832  Enable Disable DI1/DI2/DI2 as trigger,
... ... @@ -850,6 +850,7 @@
850 850  )))
851 851  
852 852  
882 +
853 853  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
854 854  
855 855  Set DI1 or DI3(for LT-33222-L) trigger.
... ... @@ -877,6 +877,7 @@
877 877  )))
878 878  
879 879  
910 +
880 880  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
881 881  
882 882  Set DI2 trigger.
... ... @@ -904,9 +904,10 @@
904 904  )))
905 905  
906 906  
938 +
907 907  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
908 908  
909 -Set current trigger , base on AC port. See [[trigger mode>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
941 +Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
910 910  
911 911  * AT Command:
912 912  
... ... @@ -919,19 +919,20 @@
919 919  
920 920  (% class="box infomessage" %)
921 921  (((
922 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
954 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
923 923  )))
924 924  
925 925  
958 +
926 926  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
927 927  
928 -Set current trigger , base on AV port. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
961 +Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
929 929  
930 930  * AT Command:
931 931  
932 932  (% class="box infomessage" %)
933 933  (((
934 -**AT+AVLIM. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
967 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
935 935  )))
936 936  
937 937  * Downlink Payload (prefix 0xAA 00 ):
... ... @@ -938,10 +938,11 @@
938 938  
939 939  (% class="box infomessage" %)
940 940  (((
941 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] **
974 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] **
942 942  )))
943 943  
944 944  
978 +
945 945  ==== 3.4.2.11 Trigger – Set minimum interval ====
946 946  
947 947  Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger.
... ... @@ -961,6 +961,7 @@
961 961  )))
962 962  
963 963  
998 +
964 964  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
965 965  
966 966  * AT Command:
... ... @@ -993,6 +993,7 @@
993 993  )))
994 994  
995 995  
1031 +
996 996  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
997 997  
998 998  * AT Command:
... ... @@ -1055,6 +1055,7 @@
1055 1055  DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low
1056 1056  
1057 1057  
1094 +
1058 1058  === 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1059 1059  
1060 1060  * AT Command:
... ... @@ -1083,6 +1083,7 @@
1083 1083  Device will upload a packet if downlink code executes successfully.
1084 1084  
1085 1085  
1123 +
1086 1086  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1087 1087  
1088 1088  * AT Command:
... ... @@ -1133,15 +1133,16 @@
1133 1133  Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO.
1134 1134  
1135 1135  
1174 +
1136 1136  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1137 1137  
1138 -When voltage exceed the threshold, count. Feature see [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]
1177 +When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1139 1139  
1140 1140  * AT Command:
1141 1141  
1142 1142  (% class="box infomessage" %)
1143 1143  (((
1144 -**AT+VOLMAX    ~/~/ See [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]**
1183 +**AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1145 1145  )))
1146 1146  
1147 1147  * Downlink Payload (prefix 0xA5):
... ... @@ -1152,6 +1152,7 @@
1152 1152  )))
1153 1153  
1154 1154  
1194 +
1155 1155  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1156 1156  
1157 1157  * AT Command:
... ... @@ -1177,6 +1177,7 @@
1177 1177  )))
1178 1178  
1179 1179  
1220 +
1180 1180  ==== 3.4.2.18 Counting ~-~- Clear Counting ====
1181 1181  
1182 1182  Clear counting for counting mode
... ... @@ -1196,6 +1196,7 @@
1196 1196  )))
1197 1197  
1198 1198  
1240 +
1199 1199  ==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1200 1200  
1201 1201  * AT Command:
... ... @@ -1218,6 +1218,8 @@
1218 1218  
1219 1219  )))
1220 1220  
1263 +
1264 +
1221 1221  == 3.5 Integrate with Mydevice ==
1222 1222  
1223 1223  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
... ... @@ -1236,6 +1236,7 @@
1236 1236  
1237 1237  [[image:image-20220524094641-12.png||height="402" width="718"]]
1238 1238  
1283 +
1239 1239  **Step 3**: Create an account or log in Mydevices.
1240 1240  
1241 1241  **Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
... ... @@ -1258,6 +1258,7 @@
1258 1258  [[image:image-20220524094909-5.png||height="341" width="734"]]
1259 1259  
1260 1260  
1306 +
1261 1261  == 3.6 Interface Detail ==
1262 1262  
1263 1263  === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) ===
... ... @@ -1267,6 +1267,7 @@
1267 1267  [[image:1653356991268-289.png]]
1268 1268  
1269 1269  
1316 +
1270 1270  === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) ===
1271 1271  
1272 1272  (((
... ... @@ -1381,6 +1381,7 @@
1381 1381  )))
1382 1382  
1383 1383  
1431 +
1384 1384  === 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===
1385 1385  
1386 1386  NPN output: GND or Float. Max voltage can apply to output pin is 36v.
... ... @@ -1388,6 +1388,7 @@
1388 1388  [[image:1653357531600-905.png]]
1389 1389  
1390 1390  
1439 +
1391 1391  === 3.6.4 Analog Input Interface ===
1392 1392  
1393 1393  The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is:
... ... @@ -1416,6 +1416,7 @@
1416 1416  [[image:1653357648330-671.png||height="155" width="733"]]
1417 1417  
1418 1418  
1468 +
1419 1419  === 3.6.5 Relay Output ===
1420 1420  
1421 1421  (((
... ... @@ -1427,6 +1427,7 @@
1427 1427  [[image:image-20220524100215-10.png||height="382" width="723"]]
1428 1428  
1429 1429  
1480 +
1430 1430  == 3.7 LEDs Indicators ==
1431 1431  
1432 1432  [[image:image-20220524100748-11.png]]
... ... @@ -1636,6 +1636,8 @@
1636 1636  
1637 1637  )))
1638 1638  
1690 +
1691 +
1639 1639  == 4.2 Common AT Command Sequence ==
1640 1640  
1641 1641  === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
... ... @@ -1679,6 +1679,8 @@
1679 1679  
1680 1680  )))
1681 1681  
1735 +
1736 +
1682 1682  === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) ===
1683 1683  
1684 1684  (((
... ... @@ -1752,6 +1752,8 @@
1752 1752  
1753 1753  )))
1754 1754  
1810 +
1811 +
1755 1755  === 4.2.3 Change to Class A ===
1756 1756  
1757 1757  If sensor JOINED
... ... @@ -1792,6 +1792,8 @@
1792 1792  
1793 1793  (((
1794 1794  (((
1852 +
1853 +
1795 1795  == 5.2 How to change the LoRa Frequency Bands/Region? ==
1796 1796  )))
1797 1797  )))
... ... @@ -1803,6 +1803,9 @@
1803 1803  )))
1804 1804  
1805 1805  (((
1865 +
1866 +
1867 +
1806 1806  == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? ==
1807 1807  )))
1808 1808  
... ... @@ -1830,23 +1830,25 @@
1830 1830  (% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.
1831 1831  )))
1832 1832  
1895 +
1833 1833  (((
1834 1834  (% style="color:#4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands:
1835 1835  )))
1836 1836  
1837 1837  (((
1838 -(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access.
1839 -(% style="background-color:#dcdcdc" %)AT+FDR  (%%) Reset Parameters to Factory Default, Keys Reserve
1840 -(% style="background-color:#dcdcdc" %)123456  (%%) Enter Password to have AT access.
1841 -(% style="background-color:#dcdcdc" %)AT+NJM=0 (%%)Set to ABP mode
1842 -(% style="background-color:#dcdcdc" %)AT+ADR=0 (%%)Set the Adaptive Data Rate Off
1843 -(% style="background-color:#dcdcdc" %)AT+DR=5 (%%) Set Data Rate (Set AT+DR=3 for 915 band)
1844 -(% style="background-color:#dcdcdc" %)AT+TDC=60000  (%%)Set transmit interval to 60 seconds
1845 -(% style="background-color:#dcdcdc" %)AT+CHS=868400000 (%%)Set transmit frequency to 868.4Mhz
1846 -(% style="background-color:#dcdcdc" %)AT+DADDR=26 01 1A F1(%%) Set Device Address to 26 01 1A F1
1847 -(% style="background-color:#dcdcdc" %)ATZ                (%%)Reset MCU
1901 +(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access.
1902 +(% style="background-color:#dcdcdc" %)AT+FDR(%%)  Reset Parameters to Factory Default, Keys Reserve
1903 +(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access.
1904 +(% style="background-color:#dcdcdc" %)AT+NJM=0 (%%) Set to ABP mode
1905 +(% style="background-color:#dcdcdc" %)AT+ADR=0 (%%) Set the Adaptive Data Rate Off
1906 +(% style="background-color:#dcdcdc" %)AT+DR=5 (%%) Set Data Rate (Set AT+DR=3 for 915 band)
1907 +(% style="background-color:#dcdcdc" %)AT+TDC=60000 (%%) Set transmit interval to 60 seconds
1908 +(% style="background-color:#dcdcdc" %)AT+CHS=868400000(%%)  Set transmit frequency to 868.4Mhz
1909 +(% style="background-color:#dcdcdc" %)AT+DADDR=26 01 1A F1(%%)  Set Device Address to 26 01 1A F1
1910 +(% style="background-color:#dcdcdc" %)ATZ  (%%) Reset MCU
1848 1848  )))
1849 1849  
1913 +
1850 1850  (((
1851 1851  As shown in below:
1852 1852  )))
... ... @@ -1859,10 +1859,15 @@
1859 1859  (((
1860 1860  User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn’t support AT+DEBUG. User can update to latest firmware first.
1861 1861  
1862 -
1926 +
1927 +== 5.5 Can i use point to point communication for LT-22222-L? ==
1928 +
1929 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
1863 1863  )))
1864 1864  
1865 1865  (((
1933 +
1934 +
1866 1866  = 6. Trouble Shooting =
1867 1867  )))
1868 1868  
... ... @@ -1874,11 +1874,11 @@
1874 1874  
1875 1875  (((
1876 1876  Please see this link for how to debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H5.1Howitwork"]]
1877 -
1878 -
1879 1879  )))
1880 1880  
1881 1881  (((
1949 +
1950 +
1882 1882  == 6.2 Have trouble to upload image. ==
1883 1883  )))
1884 1884  
... ... @@ -1888,9 +1888,7 @@
1888 1888  
1889 1889  (((
1890 1890  
1891 -)))
1892 1892  
1893 -(((
1894 1894  == 6.3 Why I can’t join TTN in US915 /AU915 bands? ==
1895 1895  )))
1896 1896  
... ... @@ -1898,147 +1898,62 @@
1898 1898  It might be about the channels mapping. [[Please see this link for detail>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1899 1899  )))
1900 1900  
1901 -(((
1902 -
1903 -)))
1904 1904  
1905 -(((
1969 +
1906 1906  = 7. Order Info =
1907 -)))
1908 1908  
1909 -(((
1910 -(((
1972 +
1911 1911  (% style="color:#4f81bd" %)**LT-22222-L-XXX:**
1912 -)))
1913 -)))
1914 1914  
1915 -(((
1916 -(((
1975 +
1917 1917  (% style="color:#4f81bd" %)**XXX:**
1918 -)))
1919 -)))
1920 1920  
1921 -(((
1922 -* (((
1923 -(% style="color:#4f81bd" %)**EU433**(%%): LT with frequency bands EU433
1924 -)))
1925 -)))
1978 +* (% style="color:#4f81bd" %)**EU433**(%%): LT with frequency bands EU433
1979 +* (% style="color:#4f81bd" %)**EU868**(%%): LT with frequency bands EU868
1980 +* (% style="color:#4f81bd" %)**KR920**(%%): LT with frequency bands KR920
1981 +* (% style="color:#4f81bd" %)**CN470**(%%): LT with frequency bands CN470
1982 +* (% style="color:#4f81bd" %)**AS923**(%%): LT with frequency bands AS923
1983 +* (% style="color:#4f81bd" %)**AU915**(%%): LT with frequency bands AU915
1984 +* (% style="color:#4f81bd" %)**US915**(%%): LT with frequency bands US915
1985 +* (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1986 +* (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1926 1926  
1927 -(((
1928 -* (((
1929 -(% style="color:#4f81bd" %)**EU868**(%%): LT with frequency bands EU868
1930 -)))
1931 -)))
1932 1932  
1933 -(((
1934 -* (((
1935 -(% style="color:#4f81bd" %)**KR920**(%%): LT with frequency bands KR920
1936 -)))
1937 -)))
1938 1938  
1939 -(((
1940 -* (((
1941 -(% style="color:#4f81bd" %)**CN470**(%%): LT with frequency bands CN470
1942 -)))
1943 -)))
1944 -
1945 -(((
1946 -* (((
1947 -(% style="color:#4f81bd" %)**AS923**(%%): LT with frequency bands AS923
1948 -)))
1949 -)))
1950 -
1951 -(((
1952 -* (((
1953 -(% style="color:#4f81bd" %)**AU915**(%%): LT with frequency bands AU915
1954 -)))
1955 -)))
1956 -
1957 -(((
1958 -* (((
1959 -(% style="color:#4f81bd" %)**US915**(%%): LT with frequency bands US915
1960 -)))
1961 -)))
1962 -
1963 -(((
1964 -* (((
1965 -(% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1966 -)))
1967 -)))
1968 -
1969 -(((
1970 -* (((
1971 -(% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1972 -
1973 -
1974 -)))
1975 -
1976 1976  = 8. Packing Info =
1977 -)))
1978 1978  
1979 -(((
1980 -(((
1992 +
1981 1981  **Package Includes**:
1982 -)))
1983 -)))
1984 1984  
1985 -(((
1986 -(((
1987 1987  * LT-22222-L I/O Controller x 1
1988 1988  * Stick Antenna for LoRa RF part x 1
1989 1989  * Bracket for controller x1
1990 1990  * Program cable x 1
1991 -)))
1992 -)))
1993 1993  
1994 -(((
1995 -(((
2000 +
1996 1996  **Dimension and weight**:
1997 -)))
1998 -)))
1999 1999  
2000 -(((
2001 -(((
2002 2002  * Device Size: 13.5 x 7 x 3 cm
2003 2003  * Device Weight: 105g
2004 2004  * Package Size / pcs : 14.5 x 8 x 5 cm
2005 2005  * Weight / pcs : 170g
2006 2006  
2007 -
2008 -)))
2009 -)))
2010 2010  
2011 -(((
2009 +
2012 2012  = 9. Support =
2013 -)))
2014 2014  
2015 2015  * (((
2016 -(((
2017 2017  Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
2018 2018  )))
2019 -)))
2020 2020  * (((
2021 -(((
2022 -Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to
2016 +Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
2023 2023  )))
2024 -)))
2025 2025  
2026 -(((
2027 -(((
2028 - [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
2029 2029  
2030 -
2031 -)))
2032 2032  
2033 -(((
2034 2034  = 10. Reference​​​​​ =
2035 2035  
2036 -* Product Page:
2037 -
2038 -LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
2039 -
2023 +* LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
2040 2040  * [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]
2041 2041  * [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
2042 2042  * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
2043 -)))