Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,6 +11,9 @@ 11 11 12 12 13 13 14 + 15 + 16 + 14 14 = 1.Introduction = 15 15 16 16 == 1.1 What is LT Series I/O Controller == ... ... @@ -48,6 +48,8 @@ 48 48 == 1.2 Specifications == 49 49 50 50 ((( 54 + 55 + 51 51 **Hardware System:** 52 52 ))) 53 53 ... ... @@ -70,6 +70,7 @@ 70 70 ))) 71 71 ))) 72 72 78 + 73 73 ((( 74 74 **Interface for Model: LT22222-L:** 75 75 ))) ... ... @@ -93,6 +93,7 @@ 93 93 Power Input 7~~ 24V DC. 94 94 ))) 95 95 102 + 96 96 ((( 97 97 **LoRa Spec:** 98 98 ))) ... ... @@ -157,6 +157,8 @@ 157 157 158 158 ))) 159 159 167 + 168 + 160 160 == 1.3 Features == 161 161 162 162 * LoRaWAN Class A & Class C protocol ... ... @@ -178,6 +178,8 @@ 178 178 * Smart Cities 179 179 * Smart Factory 180 180 190 + 191 + 181 181 == 1.5 Hardware Variants == 182 182 183 183 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -191,6 +191,8 @@ 191 191 * 1 x Counting Port 192 192 ))) 193 193 205 + 206 + 194 194 = 2. Power ON Device = 195 195 196 196 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -202,6 +202,7 @@ 202 202 [[image:1653297104069-180.png]] 203 203 204 204 218 + 205 205 = 3. Operation Mode = 206 206 207 207 == 3.1 How it works? == ... ... @@ -216,6 +216,8 @@ 216 216 217 217 ))) 218 218 233 + 234 + 219 219 == 3.2 Example to join LoRaWAN network == 220 220 221 221 ((( ... ... @@ -257,6 +257,7 @@ 257 257 [[image:1653298044601-602.png||height="405" width="709"]] 258 258 259 259 276 + 260 260 == 3.3 Uplink Payload == 261 261 262 262 There are five working modes + one interrupt mode on LT for different type application: ... ... @@ -268,6 +268,8 @@ 268 268 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 269 269 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 270 270 288 + 289 + 271 271 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 272 272 273 273 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -303,6 +303,7 @@ 303 303 * [1] RO1 relay channel is close and the RO1 LED is ON. 304 304 * [0] RO2 relay channel is open and RO2 LED is OFF; 305 305 325 + 306 306 **LT22222-L:** 307 307 308 308 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -318,6 +318,8 @@ 318 318 ** DO1 is high in case there is load between DO1 and V+. 319 319 ** DO1 LED is off in both case 320 320 341 + 342 + 321 321 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 322 322 323 323 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. ... ... @@ -411,6 +411,7 @@ 411 411 ))) 412 412 413 413 436 + 414 414 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 415 415 416 416 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -455,6 +455,8 @@ 455 455 456 456 ))) 457 457 481 + 482 + 458 458 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 459 459 460 460 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -536,6 +536,7 @@ 536 536 ))) 537 537 538 538 564 + 539 539 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 540 540 541 541 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -580,6 +580,8 @@ 580 580 581 581 ))) 582 582 609 + 610 + 583 583 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 584 584 585 585 (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** ... ... @@ -606,6 +606,7 @@ 606 606 607 607 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 608 608 637 + 609 609 (% style="color:#4f81bd" %)**Trigger base on current**: 610 610 611 611 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -614,6 +614,7 @@ 614 614 615 615 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 616 616 646 + 617 617 (% style="color:#4f81bd" %)**Trigger base on DI status**: 618 618 619 619 DI status trigger Flag. ... ... @@ -701,6 +701,7 @@ 701 701 When device got this command, it will send the MOD6 payload. 702 702 703 703 734 + 704 704 === 3.3.7 Payload Decoder === 705 705 706 706 ((( ... ... @@ -709,6 +709,8 @@ 709 709 710 710 ))) 711 711 743 + 744 + 712 712 == 3.4 Configure LT via AT or Downlink == 713 713 714 714 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -717,15 +717,18 @@ 717 717 There are two kinds of Commands: 718 718 ))) 719 719 720 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands753 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 721 721 722 722 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 723 723 757 + 758 + 724 724 === 3.4.1 Common Commands === 725 725 726 726 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 727 727 728 728 764 + 729 729 === 3.4.2 Sensor related commands === 730 730 731 731 ==== 3.4.2.1 Set Transmit Interval ==== ... ... @@ -749,6 +749,7 @@ 749 749 ))) 750 750 751 751 788 + 752 752 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 753 753 754 754 Set work mode. ... ... @@ -770,6 +770,7 @@ 770 770 ))) 771 771 772 772 810 + 773 773 ==== 3.4.2.3 Poll an uplink ==== 774 774 775 775 * AT Command: ... ... @@ -786,9 +786,10 @@ 786 786 **Example**: 0x08FF, ask device to send an Uplink 787 787 788 788 827 + 789 789 ==== 3.4.2.4 Enable Trigger Mode ==== 790 790 791 -Use of trigger mode, please check [[ADDMOD6>> path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]830 +Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 792 792 793 793 * AT Command: 794 794 ... ... @@ -809,6 +809,7 @@ 809 809 ))) 810 810 811 811 851 + 812 812 ==== 3.4.2.5 Poll trigger settings ==== 813 813 814 814 Poll trigger settings, ... ... @@ -825,6 +825,7 @@ 825 825 ))) 826 826 827 827 868 + 828 828 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 829 829 830 830 Enable Disable DI1/DI2/DI2 as trigger, ... ... @@ -848,6 +848,7 @@ 848 848 ))) 849 849 850 850 892 + 851 851 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 852 852 853 853 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -875,6 +875,7 @@ 875 875 ))) 876 876 877 877 920 + 878 878 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 879 879 880 880 Set DI2 trigger. ... ... @@ -902,9 +902,10 @@ 902 902 ))) 903 903 904 904 948 + 905 905 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 906 906 907 -Set current trigger , base on AC port. See [[trigger mode>> path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]951 +Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 908 908 909 909 * AT Command: 910 910 ... ... @@ -917,19 +917,20 @@ 917 917 918 918 (% class="box infomessage" %) 919 919 ((( 920 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>> url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**964 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 921 921 ))) 922 922 923 923 968 + 924 924 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 925 925 926 -Set current trigger , base on AV port. See [[trigger mode>> url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]971 +Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 927 927 928 928 * AT Command: 929 929 930 930 (% class="box infomessage" %) 931 931 ((( 932 -**AT+AVLIM. See [[trigger mode>> url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**977 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 933 933 ))) 934 934 935 935 * Downlink Payload (prefix 0xAA 00 ): ... ... @@ -936,10 +936,11 @@ 936 936 937 937 (% class="box infomessage" %) 938 938 ((( 939 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>> url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] **984 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 940 940 ))) 941 941 942 942 988 + 943 943 ==== 3.4.2.11 Trigger – Set minimum interval ==== 944 944 945 945 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. ... ... @@ -1133,13 +1133,13 @@ 1133 1133 1134 1134 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1135 1135 1136 -When voltage exceed the threshold, count. Feature see [[MOD4>> path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]1182 +When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1137 1137 1138 1138 * AT Command: 1139 1139 1140 1140 (% class="box infomessage" %) 1141 1141 ((( 1142 -**AT+VOLMAX ~/~/ See [[MOD4>> path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]**1188 +**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1143 1143 ))) 1144 1144 1145 1145 * Downlink Payload (prefix 0xA5): ... ... @@ -1234,6 +1234,7 @@ 1234 1234 1235 1235 [[image:image-20220524094641-12.png||height="402" width="718"]] 1236 1236 1283 + 1237 1237 **Step 3**: Create an account or log in Mydevices. 1238 1238 1239 1239 **Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %) ... ... @@ -1857,6 +1857,11 @@ 1857 1857 ((( 1858 1858 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn’t support AT+DEBUG. User can update to latest firmware first. 1859 1859 1907 + 1908 +== 5.5 Can i use point to point communication for LT-22222-L? == 1909 + 1910 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1911 + 1860 1860 1861 1861 ))) 1862 1862