<
From version < 75.15 >
edited by Xiaoling
on 2022/06/01 17:41
To version < 75.6 >
edited by Xiaoling
on 2022/06/01 17:27
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -167,8 +167,6 @@
167 167  * Firmware upgradable via program port
168 168  * Counting
169 169  
170 -
171 -
172 172  == 1.4  Applications ==
173 173  
174 174  * Smart Buildings & Home Automation
... ... @@ -178,8 +178,6 @@
178 178  * Smart Cities
179 179  * Smart Factory
180 180  
181 -
182 -
183 183  == 1.5 Hardware Variants ==
184 184  
185 185  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -193,8 +193,6 @@
193 193  * 1 x Counting Port
194 194  )))
195 195  
196 -
197 -
198 198  = 2. Power ON Device =
199 199  
200 200  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -272,8 +272,6 @@
272 272  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
273 273  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
274 274  
275 -
276 -
277 277  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
278 278  
279 279  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -324,8 +324,6 @@
324 324  ** DO1 is high in case there is load between DO1 and V+.
325 325  ** DO1 LED is off in both case
326 326  
327 -
328 -
329 329  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
330 330  
331 331  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
... ... @@ -614,7 +614,6 @@
614 614  
615 615  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
616 616  
617 -
618 618  (% style="color:#4f81bd" %)**Trigger base on current**:
619 619  
620 620  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -623,7 +623,6 @@
623 623  
624 624  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
625 625  
626 -
627 627  (% style="color:#4f81bd" %)**Trigger base on DI status**:
628 628  
629 629  DI status trigger Flag.
... ... @@ -727,7 +727,7 @@
727 727  There are two kinds of Commands:
728 728  )))
729 729  
730 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
718 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
731 731  
732 732  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
733 733  
... ... @@ -798,7 +798,7 @@
798 798  
799 799  ==== 3.4.2.4 Enable Trigger Mode ====
800 800  
801 -Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
789 +Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
802 802  
803 803  * AT Command:
804 804  
... ... @@ -914,7 +914,7 @@
914 914  
915 915  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
916 916  
917 -Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
905 +Set current trigger , base on AC port. See [[trigger mode>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
918 918  
919 919  * AT Command:
920 920  
... ... @@ -927,19 +927,19 @@
927 927  
928 928  (% class="box infomessage" %)
929 929  (((
930 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
918 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
931 931  )))
932 932  
933 933  
934 934  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
935 935  
936 -Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
924 +Set current trigger , base on AV port. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
937 937  
938 938  * AT Command:
939 939  
940 940  (% class="box infomessage" %)
941 941  (((
942 -**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
930 +**AT+AVLIM. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
943 943  )))
944 944  
945 945  * Downlink Payload (prefix 0xAA 00 ):
... ... @@ -946,7 +946,7 @@
946 946  
947 947  (% class="box infomessage" %)
948 948  (((
949 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] **
937 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] **
950 950  )))
951 951  
952 952  
... ... @@ -1143,7 +1143,7 @@
1143 1143  
1144 1144  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1145 1145  
1146 -When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1134 +When voltage exceed the threshold, count. Feature see [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]
1147 1147  
1148 1148  * AT Command:
1149 1149  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0