Last modified by Mengting Qiu on 2025/06/04 18:42

From version 75.11
edited by Xiaoling
on 2022/06/01 17:29
Change comment: There is no comment for this version
To version 75.14
edited by Xiaoling
on 2022/06/01 17:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -614,6 +614,7 @@
614 614  
615 615  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
616 616  
617 +
617 617  (% style="color:#4f81bd" %)**Trigger base on current**:
618 618  
619 619  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -622,6 +622,7 @@
622 622  
623 623  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
624 624  
626 +
625 625  (% style="color:#4f81bd" %)**Trigger base on DI status**:
626 626  
627 627  DI status trigger Flag.
... ... @@ -725,7 +725,7 @@
725 725  There are two kinds of Commands:
726 726  )))
727 727  
728 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
730 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
729 729  
730 730  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
731 731  
... ... @@ -796,7 +796,7 @@
796 796  
797 797  ==== 3.4.2.4 Enable Trigger Mode ====
798 798  
799 -Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
801 +Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
800 800  
801 801  * AT Command:
802 802  
... ... @@ -912,7 +912,7 @@
912 912  
913 913  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
914 914  
915 -Set current trigger , base on AC port. See [[trigger mode>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
917 +Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
916 916  
917 917  * AT Command:
918 918