From version < 75.10 >
edited by Xiaoling
on 2022/06/01 17:29
To version < 77.10 >
edited by Xiaoling
on 2022/06/10 08:38
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,6 +11,9 @@
11 11  
12 12  
13 13  
14 +
15 +
16 +
14 14  = 1.Introduction =
15 15  
16 16  == 1.1 What is LT Series I/O Controller ==
... ... @@ -48,6 +48,8 @@
48 48  == 1.2  Specifications ==
49 49  
50 50  (((
54 +
55 +
51 51  **Hardware System:**
52 52  )))
53 53  
... ... @@ -70,6 +70,7 @@
70 70  )))
71 71  )))
72 72  
78 +
73 73  (((
74 74  **Interface for Model: LT22222-L:**
75 75  )))
... ... @@ -93,6 +93,7 @@
93 93  Power Input 7~~ 24V DC. 
94 94  )))
95 95  
102 +
96 96  (((
97 97  **LoRa Spec:**
98 98  )))
... ... @@ -157,6 +157,8 @@
157 157  
158 158  )))
159 159  
167 +
168 +
160 160  == 1.3 Features ==
161 161  
162 162  * LoRaWAN Class A & Class C protocol
... ... @@ -206,6 +206,7 @@
206 206  [[image:1653297104069-180.png]]
207 207  
208 208  
218 +
209 209  = 3. Operation Mode =
210 210  
211 211  == 3.1 How it works? ==
... ... @@ -220,6 +220,8 @@
220 220  
221 221  )))
222 222  
233 +
234 +
223 223  == 3.2 Example to join LoRaWAN network ==
224 224  
225 225  (((
... ... @@ -261,6 +261,7 @@
261 261  [[image:1653298044601-602.png||height="405" width="709"]]
262 262  
263 263  
276 +
264 264  == 3.3 Uplink Payload ==
265 265  
266 266  There are five working modes + one interrupt mode on LT for different type application:
... ... @@ -612,6 +612,7 @@
612 612  
613 613  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
614 614  
628 +
615 615  (% style="color:#4f81bd" %)**Trigger base on current**:
616 616  
617 617  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -620,6 +620,7 @@
620 620  
621 621  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
622 622  
637 +
623 623  (% style="color:#4f81bd" %)**Trigger base on DI status**:
624 624  
625 625  DI status trigger Flag.
... ... @@ -723,7 +723,7 @@
723 723  There are two kinds of Commands:
724 724  )))
725 725  
726 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
741 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
727 727  
728 728  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
729 729  
... ... @@ -794,7 +794,7 @@
794 794  
795 795  ==== 3.4.2.4 Enable Trigger Mode ====
796 796  
797 -Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
812 +Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
798 798  
799 799  * AT Command:
800 800  
... ... @@ -910,7 +910,7 @@
910 910  
911 911  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
912 912  
913 -Set current trigger , base on AC port. See [[trigger mode>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
928 +Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
914 914  
915 915  * AT Command:
916 916  
... ... @@ -923,19 +923,19 @@
923 923  
924 924  (% class="box infomessage" %)
925 925  (((
926 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
941 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
927 927  )))
928 928  
929 929  
930 930  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
931 931  
932 -Set current trigger , base on AV port. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
947 +Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
933 933  
934 934  * AT Command:
935 935  
936 936  (% class="box infomessage" %)
937 937  (((
938 -**AT+AVLIM. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
953 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
939 939  )))
940 940  
941 941  * Downlink Payload (prefix 0xAA 00 ):
... ... @@ -942,7 +942,7 @@
942 942  
943 943  (% class="box infomessage" %)
944 944  (((
945 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] **
960 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] **
946 946  )))
947 947  
948 948  
... ... @@ -1139,13 +1139,13 @@
1139 1139  
1140 1140  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1141 1141  
1142 -When voltage exceed the threshold, count. Feature see [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]
1157 +When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1143 1143  
1144 1144  * AT Command:
1145 1145  
1146 1146  (% class="box infomessage" %)
1147 1147  (((
1148 -**AT+VOLMAX    ~/~/ See [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]**
1163 +**AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1149 1149  )))
1150 1150  
1151 1151  * Downlink Payload (prefix 0xA5):
... ... @@ -1240,6 +1240,7 @@
1240 1240  
1241 1241  [[image:image-20220524094641-12.png||height="402" width="718"]]
1242 1242  
1258 +
1243 1243  **Step 3**: Create an account or log in Mydevices.
1244 1244  
1245 1245  **Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
... ... @@ -1863,6 +1863,11 @@
1863 1863  (((
1864 1864  User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn’t support AT+DEBUG. User can update to latest firmware first.
1865 1865  
1882 +
1883 +== 5.5 Can i use point to point communication for LT-22222-L? ==
1884 +
1885 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
1886 +
1866 1866  
1867 1867  )))
1868 1868  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0