From version < 75.10 >
edited by Xiaoling
on 2022/06/01 17:29
To version < 77.1 >
edited by Edwin Chen
on 2022/06/02 15:25
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -167,8 +167,6 @@
167 167  * Firmware upgradable via program port
168 168  * Counting
169 169  
170 -
171 -
172 172  == 1.4  Applications ==
173 173  
174 174  * Smart Buildings & Home Automation
... ... @@ -178,8 +178,6 @@
178 178  * Smart Cities
179 179  * Smart Factory
180 180  
181 -
182 -
183 183  == 1.5 Hardware Variants ==
184 184  
185 185  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -193,8 +193,6 @@
193 193  * 1 x Counting Port
194 194  )))
195 195  
196 -
197 -
198 198  = 2. Power ON Device =
199 199  
200 200  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -272,8 +272,6 @@
272 272  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
273 273  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
274 274  
275 -
276 -
277 277  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
278 278  
279 279  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -612,6 +612,7 @@
612 612  
613 613  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
614 614  
607 +
615 615  (% style="color:#4f81bd" %)**Trigger base on current**:
616 616  
617 617  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -620,6 +620,7 @@
620 620  
621 621  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
622 622  
616 +
623 623  (% style="color:#4f81bd" %)**Trigger base on DI status**:
624 624  
625 625  DI status trigger Flag.
... ... @@ -723,7 +723,7 @@
723 723  There are two kinds of Commands:
724 724  )))
725 725  
726 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
720 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
727 727  
728 728  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
729 729  
... ... @@ -794,7 +794,7 @@
794 794  
795 795  ==== 3.4.2.4 Enable Trigger Mode ====
796 796  
797 -Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
791 +Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
798 798  
799 799  * AT Command:
800 800  
... ... @@ -910,7 +910,7 @@
910 910  
911 911  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
912 912  
913 -Set current trigger , base on AC port. See [[trigger mode>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
907 +Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
914 914  
915 915  * AT Command:
916 916  
... ... @@ -923,19 +923,19 @@
923 923  
924 924  (% class="box infomessage" %)
925 925  (((
926 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
920 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
927 927  )))
928 928  
929 929  
930 930  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
931 931  
932 -Set current trigger , base on AV port. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
926 +Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
933 933  
934 934  * AT Command:
935 935  
936 936  (% class="box infomessage" %)
937 937  (((
938 -**AT+AVLIM. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
932 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
939 939  )))
940 940  
941 941  * Downlink Payload (prefix 0xAA 00 ):
... ... @@ -942,7 +942,7 @@
942 942  
943 943  (% class="box infomessage" %)
944 944  (((
945 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] **
939 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] **
946 946  )))
947 947  
948 948  
... ... @@ -1139,13 +1139,13 @@
1139 1139  
1140 1140  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1141 1141  
1142 -When voltage exceed the threshold, count. Feature see [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]
1136 +When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1143 1143  
1144 1144  * AT Command:
1145 1145  
1146 1146  (% class="box infomessage" %)
1147 1147  (((
1148 -**AT+VOLMAX    ~/~/ See [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]**
1142 +**AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1149 1149  )))
1150 1150  
1151 1151  * Downlink Payload (prefix 0xA5):
... ... @@ -1240,6 +1240,7 @@
1240 1240  
1241 1241  [[image:image-20220524094641-12.png||height="402" width="718"]]
1242 1242  
1237 +
1243 1243  **Step 3**: Create an account or log in Mydevices.
1244 1244  
1245 1245  **Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
... ... @@ -1863,6 +1863,11 @@
1863 1863  (((
1864 1864  User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn’t support AT+DEBUG. User can update to latest firmware first.
1865 1865  
1861 +
1862 +== 5.5 Can i use point to point communication for LT-22222-L? ==
1863 +
1864 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
1865 +
1866 1866  
1867 1867  )))
1868 1868  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved