... ... @@ -1278,50 +1278,103 @@ 1278 1278 [[image:1653357170703-587.png]] 1279 1279 1280 1280 ((( 1281 +((( 1281 1281 When use need to connect a device to the DI port, both DI1+ and DI1- must be connected. 1282 1282 ))) 1284 +))) 1283 1283 1286 +((( 1287 + 1288 +))) 1284 1284 1290 +((( 1285 1285 **Example1**: Connect to a Low active sensor. 1292 +))) 1286 1286 1294 +((( 1287 1287 This type of sensor will output a low signal GND when active. 1296 +))) 1288 1288 1289 -* Connect sensor’s output to DI1- 1290 -* Connect sensor’s VCC to DI1+. 1298 +* ((( 1299 +Connect sensor’s output to DI1- 1300 +))) 1301 +* ((( 1302 +Connect sensor’s VCC to DI1+. 1303 +))) 1291 1291 1305 +((( 1292 1292 So when sensor active, the current between NEC2501 pin1 and pin2 is: 1307 +))) 1293 1293 1309 +((( 1294 1294 [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]** [[image:image-20220524095628-8.png]] = DI1+ / 1K.** 1311 +))) 1295 1295 1313 +((( 1296 1296 If DI1+ = 12v, the //IF// = 12mA , So the LT-22222-L will be able to detect this active signal. 1315 +))) 1297 1297 1317 +((( 1318 + 1319 +))) 1298 1298 1321 +((( 1299 1299 **Example2**: Connect to a High active sensor. 1323 +))) 1300 1300 1325 +((( 1301 1301 This type of sensor will output a high signal (example 24v) when active. 1327 +))) 1302 1302 1303 -* Connect sensor’s output to DI1+ 1304 -* Connect sensor’s GND DI1-. 1329 +* ((( 1330 +Connect sensor’s output to DI1+ 1331 +))) 1332 +* ((( 1333 +Connect sensor’s GND DI1-. 1334 +))) 1305 1305 1336 +((( 1306 1306 So when sensor active, the current between NEC2501 pin1 and pin2 is: 1338 +))) 1307 1307 1340 +((( 1308 1308 [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]** [[image:image-20220524095628-8.png]]= DI1+ / 1K.** 1342 +))) 1309 1309 1344 +((( 1310 1310 If **DI1+ = 24v**, the [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]]** = 24mA , So the LT-22222-L will be able to detect this high active signal. 1346 +))) 1311 1311 1348 +((( 1349 + 1350 +))) 1312 1312 1352 +((( 1313 1313 **Example3**: Connect to a 220v high active sensor. 1354 +))) 1314 1314 1356 +((( 1315 1315 Assume user want to monitor an active signal higher than 220v, to make sure not burn the photocoupler 1358 +))) 1316 1316 1317 -* Connect sensor’s output to DI1+ with a serial 50K resistor 1318 -* Connect sensor’s GND DI1-. 1360 +* ((( 1361 +Connect sensor’s output to DI1+ with a serial 50K resistor 1362 +))) 1363 +* ((( 1364 +Connect sensor’s GND DI1-. 1365 +))) 1319 1319 1367 +((( 1320 1320 So when sensor active, the current between NEC2501 pin1 and pin2 is: 1369 +))) 1321 1321 1322 - [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]][[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]][[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]] = DI1+ / 51K.** 1371 +((( 1372 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]] = DI1+ / 51K.** 1373 +))) 1323 1323 1375 +((( 1324 1324 If sensor output is 220v, the (% id="cke_bm_243359S" style="display:none" %)[[image:image-20220524095628-8.png]](%%) = DI1+ / 51K. = 4.3mA , So the LT-22222-L will be able to detect this high active signal safely. 1377 +))) 1325 1325 1326 1326 1327 1327 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===