Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -167,7 +167,6 @@ 167 167 * Firmware upgradable via program port 168 168 * Counting 169 169 170 - 171 171 == 1.4 Applications == 172 172 173 173 * Smart Buildings & Home Automation ... ... @@ -177,7 +177,6 @@ 177 177 * Smart Cities 178 178 * Smart Factory 179 179 180 - 181 181 == 1.5 Hardware Variants == 182 182 183 183 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -191,8 +191,6 @@ 191 191 * 1 x Counting Port 192 192 ))) 193 193 194 - 195 - 196 196 = 2. Power ON Device = 197 197 198 198 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -270,7 +270,6 @@ 270 270 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 271 271 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 272 272 273 - 274 274 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 275 275 276 276 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -306,7 +306,6 @@ 306 306 * [1] RO1 relay channel is close and the RO1 LED is ON. 307 307 * [0] RO2 relay channel is open and RO2 LED is OFF; 308 308 309 - 310 310 **LT22222-L:** 311 311 312 312 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -322,7 +322,6 @@ 322 322 ** DO1 is high in case there is load between DO1 and V+. 323 323 ** DO1 LED is off in both case 324 324 325 - 326 326 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 327 327 328 328 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. ... ... @@ -726,7 +726,6 @@ 726 726 727 727 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 728 728 729 - 730 730 === 3.4.1 Common Commands === 731 731 732 732 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1286,50 +1286,103 @@ 1286 1286 [[image:1653357170703-587.png]] 1287 1287 1288 1288 ((( 1281 +((( 1289 1289 When use need to connect a device to the DI port, both DI1+ and DI1- must be connected. 1290 1290 ))) 1284 +))) 1291 1291 1286 +((( 1287 + 1288 +))) 1292 1292 1290 +((( 1293 1293 **Example1**: Connect to a Low active sensor. 1292 +))) 1294 1294 1294 +((( 1295 1295 This type of sensor will output a low signal GND when active. 1296 +))) 1296 1296 1297 -* Connect sensor’s output to DI1- 1298 -* Connect sensor’s VCC to DI1+. 1298 +* ((( 1299 +Connect sensor’s output to DI1- 1300 +))) 1301 +* ((( 1302 +Connect sensor’s VCC to DI1+. 1303 +))) 1299 1299 1300 -So when sensor active, the current between NEC2501 pin1 and pin2 is: 1305 +((( 1306 +So when sensor active, the current between NEC2501 pin1 and pin2 is: 1307 +))) 1301 1301 1302 -[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]** [[image:image-20220524095628-8.png]] = DI1+ / 1K.** 1309 +((( 1310 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]]= DI1+ / 1K.** 1311 +))) 1303 1303 1313 +((( 1304 1304 If DI1+ = 12v, the //IF// = 12mA , So the LT-22222-L will be able to detect this active signal. 1315 +))) 1305 1305 1317 +((( 1318 + 1319 +))) 1306 1306 1321 +((( 1307 1307 **Example2**: Connect to a High active sensor. 1323 +))) 1308 1308 1325 +((( 1309 1309 This type of sensor will output a high signal (example 24v) when active. 1327 +))) 1310 1310 1311 -* Connect sensor’s output to DI1+ 1312 -* Connect sensor’s GND DI1-. 1329 +* ((( 1330 +Connect sensor’s output to DI1+ 1331 +))) 1332 +* ((( 1333 +Connect sensor’s GND DI1-. 1334 +))) 1313 1313 1336 +((( 1314 1314 So when sensor active, the current between NEC2501 pin1 and pin2 is: 1338 +))) 1315 1315 1316 -[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]** [[image:image-20220524095628-8.png]]= DI1+ / 1K.** 1340 +((( 1341 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]]= DI1+ / 1K.** 1342 +))) 1317 1317 1318 -If **DI1+ = 24v**, the [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]]** = 24mA , So the LT-22222-L will be able to detect this high active signal. 1344 +((( 1345 +If **DI1+ = 24v**, the[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]]**= 24mA , So the LT-22222-L will be able to detect this high active signal. 1346 +))) 1319 1319 1348 +((( 1349 + 1350 +))) 1320 1320 1352 +((( 1321 1321 **Example3**: Connect to a 220v high active sensor. 1354 +))) 1322 1322 1356 +((( 1323 1323 Assume user want to monitor an active signal higher than 220v, to make sure not burn the photocoupler 1358 +))) 1324 1324 1325 -* Connect sensor’s output to DI1+ with a serial 50K resistor 1326 -* Connect sensor’s GND DI1-. 1360 +* ((( 1361 +Connect sensor’s output to DI1+ with a serial 50K resistor 1362 +))) 1363 +* ((( 1364 +Connect sensor’s GND DI1-. 1365 +))) 1327 1327 1367 +((( 1328 1328 So when sensor active, the current between NEC2501 pin1 and pin2 is: 1369 +))) 1329 1329 1330 - [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]] = DI1+ / 51K.** 1371 +((( 1372 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]][[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]]= DI1+ / 51K.** 1373 +))) 1331 1331 1375 +((( 1332 1332 If sensor output is 220v, the (% id="cke_bm_243359S" style="display:none" %)[[image:image-20220524095628-8.png]](%%) = DI1+ / 51K. = 4.3mA , So the LT-22222-L will be able to detect this high active signal safely. 1377 +))) 1333 1333 1334 1334 1335 1335 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === ... ... @@ -1824,10 +1824,8 @@ 1824 1824 ))) 1825 1825 1826 1826 ((( 1827 -Please see this link for how to debug: 1872 +Please see this link for how to debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H5.1Howitwork"]] 1828 1828 1829 -[[http:~~/~~/wiki1.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H5.1Howitwork>>http://wiki1.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H5.1Howitwork]] 1830 - 1831 1831 1832 1832 ))) 1833 1833 ... ... @@ -1836,9 +1836,7 @@ 1836 1836 ))) 1837 1837 1838 1838 ((( 1839 -See this link for trouble shooting: 1840 - 1841 -[[http:~~/~~/wiki1.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/>>http://wiki1.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]] 1882 +See this link for trouble shooting: [[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]] 1842 1842 ))) 1843 1843 1844 1844 ((( ... ... @@ -1850,9 +1850,7 @@ 1850 1850 ))) 1851 1851 1852 1852 ((( 1853 -It might be about the channels mapping. Please see this link for detail: 1854 - 1855 -[[http:~~/~~/wiki1.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband>>http://wiki1.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]] 1894 +It might be about the channels mapping. [[Please see this link for detail>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1856 1856 ))) 1857 1857 1858 1858 (((