Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -306,6 +306,7 @@ 306 306 * [1] RO1 relay channel is close and the RO1 LED is ON. 307 307 * [0] RO2 relay channel is open and RO2 LED is OFF; 308 308 309 + 309 309 **LT22222-L:** 310 310 311 311 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -321,6 +321,7 @@ 321 321 ** DO1 is high in case there is load between DO1 and V+. 322 322 ** DO1 LED is off in both case 323 323 325 + 324 324 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 325 325 326 326 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. ... ... @@ -413,6 +413,7 @@ 413 413 ))) 414 414 ))) 415 415 418 + 416 416 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 417 417 418 418 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -453,6 +453,8 @@ 453 453 454 454 ((( 455 455 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 459 + 460 + 456 456 ))) 457 457 458 458 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === ... ... @@ -535,6 +535,7 @@ 535 535 ))) 536 536 ))) 537 537 543 + 538 538 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 539 539 540 540 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -575,6 +575,8 @@ 575 575 576 576 ((( 577 577 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 584 + 585 + 578 578 ))) 579 579 580 580 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === ... ... @@ -697,10 +697,13 @@ 697 697 698 698 When device got this command, it will send the MOD6 payload. 699 699 708 + 700 700 === 3.3.7 Payload Decoder === 701 701 702 702 ((( 703 703 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 713 + 714 + 704 704 ))) 705 705 706 706 == 3.4 Configure LT via AT or Downlink == ... ... @@ -715,10 +715,12 @@ 715 715 716 716 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 717 717 729 + 718 718 === 3.4.1 Common Commands === 719 719 720 720 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 721 721 734 + 722 722 === 3.4.2 Sensor related commands === 723 723 724 724 ==== 3.4.2.1 Set Transmit Interval ==== ... ... @@ -741,6 +741,7 @@ 741 741 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 742 742 ))) 743 743 757 + 744 744 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 745 745 746 746 Set work mode. ... ... @@ -761,6 +761,7 @@ 761 761 **0x0A aa ~/~/ Same as AT+MOD=aa** 762 762 ))) 763 763 778 + 764 764 ==== 3.4.2.3 Poll an uplink ==== 765 765 766 766 * AT Command: ... ... @@ -776,6 +776,7 @@ 776 776 777 777 **Example**: 0x08FF, ask device to send an Uplink 778 778 794 + 779 779 ==== 3.4.2.4 Enable Trigger Mode ==== 780 780 781 781 Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] ... ... @@ -798,6 +798,7 @@ 798 798 **0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 799 799 ))) 800 800 817 + 801 801 ==== 3.4.2.5 Poll trigger settings ==== 802 802 803 803 Poll trigger settings, ... ... @@ -813,6 +813,7 @@ 813 813 **0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 814 814 ))) 815 815 833 + 816 816 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 817 817 818 818 Enable Disable DI1/DI2/DI2 as trigger, ... ... @@ -835,6 +835,7 @@ 835 835 **0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 836 836 ))) 837 837 856 + 838 838 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 839 839 840 840 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -861,6 +861,7 @@ 861 861 **0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 862 862 ))) 863 863 883 + 864 864 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 865 865 866 866 Set DI2 trigger. ... ... @@ -887,6 +887,7 @@ 887 887 **0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 888 888 ))) 889 889 910 + 890 890 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 891 891 892 892 Set current trigger , base on AC port. See [[trigger mode>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] ... ... @@ -905,6 +905,7 @@ 905 905 **0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]** 906 906 ))) 907 907 929 + 908 908 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 909 909 910 910 Set current trigger , base on AV port. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] ... ... @@ -923,6 +923,7 @@ 923 923 **0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] ** 924 924 ))) 925 925 948 + 926 926 ==== 3.4.2.11 Trigger – Set minimum interval ==== 927 927 928 928 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. ... ... @@ -941,6 +941,7 @@ 941 941 **0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 942 942 ))) 943 943 967 + 944 944 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 945 945 946 946 * AT Command: ... ... @@ -1131,6 +1131,7 @@ 1131 1131 **0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1132 1132 ))) 1133 1133 1158 + 1134 1134 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1135 1135 1136 1136 * AT Command: ... ... @@ -1155,6 +1155,7 @@ 1155 1155 **0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1156 1156 ))) 1157 1157 1183 + 1158 1158 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1159 1159 1160 1160 Clear counting for counting mode ... ... @@ -1173,6 +1173,7 @@ 1173 1173 **0x A6 01 ~/~/ clear all counting,** 1174 1174 ))) 1175 1175 1202 + 1176 1176 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1177 1177 1178 1178 * AT Command: ... ... @@ -1191,6 +1191,8 @@ 1191 1191 1192 1192 ((( 1193 1193 range: aa bb cc:0 to 16777215, (unit:second) 1221 + 1222 + 1194 1194 ))) 1195 1195 1196 1196 == 3.5 Integrate with Mydevice == ... ... @@ -1219,6 +1219,7 @@ 1219 1219 1220 1220 [[image:1653356838789-523.png||height="337" width="740"]] 1221 1221 1251 + 1222 1222 After added, the sensor data arrive TTN, it will also arrive and show in Mydevices. 1223 1223 1224 1224 [[image:image-20220524094909-1.png||height="335" width="729"]] ... ... @@ -1231,6 +1231,7 @@ 1231 1231 1232 1232 [[image:image-20220524094909-5.png||height="341" width="734"]] 1233 1233 1264 + 1234 1234 == 3.6 Interface Detail == 1235 1235 1236 1236 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === ... ... @@ -1239,6 +1239,7 @@ 1239 1239 1240 1240 [[image:1653356991268-289.png]] 1241 1241 1273 + 1242 1242 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1243 1243 1244 1244 ((( ... ... @@ -1299,6 +1299,7 @@ 1299 1299 1300 1300 If sensor output is 220v, the (% id="cke_bm_243359S" style="display:none" %)[[image:image-20220524095628-8.png]](%%) = DI1+ / 51K. = 4.3mA , So the LT-22222-L will be able to detect this high active signal safely. 1301 1301 1334 + 1302 1302 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1303 1303 1304 1304 NPN output: GND or Float. Max voltage can apply to output pin is 36v. ... ... @@ -1305,6 +1305,7 @@ 1305 1305 1306 1306 [[image:1653357531600-905.png]] 1307 1307 1341 + 1308 1308 === 3.6.4 Analog Input Interface === 1309 1309 1310 1310 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: ... ... @@ -1332,6 +1332,7 @@ 1332 1332 1333 1333 [[image:1653357648330-671.png||height="155" width="733"]] 1334 1334 1369 + 1335 1335 === 3.6.5 Relay Output === 1336 1336 1337 1337 ((( ... ... @@ -1342,10 +1342,12 @@ 1342 1342 1343 1343 [[image:image-20220524100215-10.png||height="382" width="723"]] 1344 1344 1380 + 1345 1345 == 3.7 LEDs Indicators == 1346 1346 1347 1347 [[image:image-20220524100748-11.png]] 1348 1348 1385 + 1349 1349 = 4. Use AT Command = 1350 1350 1351 1351 == 4.1 Access AT Command == ... ... @@ -1546,6 +1546,8 @@ 1546 1546 1547 1547 ((( 1548 1548 AT+CFG: Print all settings 1586 + 1587 + 1549 1549 ))) 1550 1550 1551 1551 == 4.2 Common AT Command Sequence == ... ... @@ -1587,6 +1587,8 @@ 1587 1587 1588 1588 ((( 1589 1589 (% style="background-color:#dcdcdc" %)ATZ 1629 + 1630 + 1590 1590 ))) 1591 1591 1592 1592 === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) === ... ... @@ -1668,6 +1668,7 @@ 1668 1668 (% style="background-color:#dcdcdc" %)AT+CLASS=A 1669 1669 ATZ 1670 1670 1712 + 1671 1671 = 5. FAQ = 1672 1672 1673 1673 == 5.1 How to upgrade the image? == ... ... @@ -1698,6 +1698,7 @@ 1698 1698 1699 1699 [[image:1653360054704-518.png||height="186" width="745"]] 1700 1700 1743 + 1701 1701 ((( 1702 1702 ((( 1703 1703 == 5.2 How to change the LoRa Frequency Bands/Region? == ... ... @@ -1706,6 +1706,8 @@ 1706 1706 1707 1707 ((( 1708 1708 User can follow the introduction for [[how to upgrade image>>||anchor="H5.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. 1752 + 1753 + 1709 1709 ))) 1710 1710 1711 1711 ((( ... ... @@ -1759,10 +1759,13 @@ 1759 1759 1760 1760 [[image:1653360498588-932.png||height="485" width="726"]] 1761 1761 1807 + 1762 1762 == 5.4 Can I see counting event in Serial? == 1763 1763 1764 1764 ((( 1765 1765 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn’t support AT+DEBUG. User can update to latest firmware first. 1812 + 1813 + 1766 1766 ))) 1767 1767 1768 1768 ((( ... ... @@ -1878,6 +1878,8 @@ 1878 1878 ((( 1879 1879 * ((( 1880 1880 (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 1929 + 1930 + 1881 1881 ))) 1882 1882 1883 1883 = 8. Packing Info = ... ... @@ -1910,6 +1910,8 @@ 1910 1910 * Device Weight: 105g 1911 1911 * Package Size / pcs : 14.5 x 8 x 5 cm 1912 1912 * Weight / pcs : 170g 1963 + 1964 + 1913 1913 ))) 1914 1914 ))) 1915 1915 ... ... @@ -1931,6 +1931,8 @@ 1931 1931 ((( 1932 1932 ((( 1933 1933 [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1986 + 1987 + 1934 1934 ))) 1935 1935 1936 1936 (((