Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,12 +11,15 @@ 11 11 12 12 13 13 14 + 15 + 16 + 14 14 = 1.Introduction = 15 15 16 16 == 1.1 What is LT Series I/O Controller == 17 17 18 18 ((( 19 -The Dragino LT series I/O Modules are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as: analog current Input, analog voltage input, relay output, digital input and digital output etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 22 +The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 20 20 ))) 21 21 22 22 ((( ... ... @@ -24,7 +24,7 @@ 24 24 ))) 25 25 26 26 ((( 27 -The LT I/O Controllers is aiming to provide a s impleplugandplay, low cost installation by using LoRaWANwireless technology.30 +The LT I/O Controllers is aiming to provide an (% style="color:blue" %)**easy and low cost installation** (%%)by using LoRa wireless technology. 28 28 ))) 29 29 30 30 ((( ... ... @@ -41,11 +41,15 @@ 41 41 42 42 ((( 43 43 [[image:1653295757274-912.png]] 47 + 48 + 44 44 ))) 45 45 46 46 == 1.2 Specifications == 47 47 48 48 ((( 54 + 55 + 49 49 **Hardware System:** 50 50 ))) 51 51 ... ... @@ -151,6 +151,8 @@ 151 151 ))) 152 152 * ((( 153 153 Packet engine up to 256 bytes with CRC. 161 + 162 + 154 154 ))) 155 155 156 156 == 1.3 Features == ... ... @@ -195,6 +195,8 @@ 195 195 196 196 [[image:1653297104069-180.png]] 197 197 207 + 208 + 198 198 = 3. Operation Mode = 199 199 200 200 == 3.1 How it works? == ... ... @@ -204,13 +204,15 @@ 204 204 ))) 205 205 206 206 ((( 207 -In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H4.UseATCommand]] to set the keys in the devices. 208 -))) 218 +In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 209 209 210 -((( 211 -3.2 Example to join LoRaWAN network 220 + 212 212 ))) 213 213 223 + 224 + 225 +== 3.2 Example to join LoRaWAN network == 226 + 214 214 ((( 215 215 This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 216 216 ))) ... ... @@ -217,7 +217,6 @@ 217 217 218 218 [[image:image-20220523172350-1.png||height="266" width="864"]] 219 219 220 - 221 221 ((( 222 222 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 223 223 ))) ... ... @@ -238,10 +238,12 @@ 238 238 239 239 [[image:1653297955910-247.png||height="321" width="716"]] 240 240 253 + 241 241 Add APP KEY and DEV EUI 242 242 243 243 [[image:1653298023685-319.png]] 244 244 258 + 245 245 ((( 246 246 **Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 247 247 ))) ... ... @@ -248,6 +248,8 @@ 248 248 249 249 [[image:1653298044601-602.png||height="405" width="709"]] 250 250 265 + 266 + 251 251 == 3.3 Uplink Payload == 252 252 253 253 There are five working modes + one interrupt mode on LT for different type application: ... ... @@ -401,6 +401,8 @@ 401 401 ))) 402 402 ))) 403 403 420 + 421 + 404 404 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 405 405 406 406 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -440,9 +440,13 @@ 440 440 ))) 441 441 442 442 ((( 443 -Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.2AT2BMOD3D22C28DoubleDICounting29]]. 461 +Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 462 + 463 + 444 444 ))) 445 445 466 + 467 + 446 446 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 447 447 448 448 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -488,7 +488,7 @@ 488 488 ))) 489 489 490 490 ((( 491 -Other AT Commands for counting are similar to [[MOD2 Counting Command>> path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.2AT2BMOD3D22C28DoubleDICounting29]].513 +Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 492 492 ))) 493 493 494 494 ((( ... ... @@ -523,6 +523,8 @@ 523 523 ))) 524 524 ))) 525 525 548 + 549 + 526 526 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 527 527 528 528 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -562,9 +562,13 @@ 562 562 ))) 563 563 564 564 ((( 565 -Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.2AT2BMOD3D22C28DoubleDICounting29]]. 589 +Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 590 + 591 + 566 566 ))) 567 567 594 + 595 + 568 568 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 569 569 570 570 (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** ... ... @@ -591,6 +591,7 @@ 591 591 592 592 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 593 593 622 + 594 594 (% style="color:#4f81bd" %)**Trigger base on current**: 595 595 596 596 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -599,6 +599,7 @@ 599 599 600 600 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 601 601 631 + 602 602 (% style="color:#4f81bd" %)**Trigger base on DI status**: 603 603 604 604 DI status trigger Flag. ... ... @@ -685,12 +685,18 @@ 685 685 686 686 When device got this command, it will send the MOD6 payload. 687 687 718 + 719 + 688 688 === 3.3.7 Payload Decoder === 689 689 690 690 ((( 691 691 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 724 + 725 + 692 692 ))) 693 693 728 + 729 + 694 694 == 3.4 Configure LT via AT or Downlink == 695 695 696 696 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -699,14 +699,16 @@ 699 699 There are two kinds of Commands: 700 700 ))) 701 701 702 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands738 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 703 703 704 704 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 705 705 706 706 === 3.4.1 Common Commands === 707 707 708 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>> http://8.211.40.43:8080/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]744 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 709 709 746 + 747 + 710 710 === 3.4.2 Sensor related commands === 711 711 712 712 ==== 3.4.2.1 Set Transmit Interval ==== ... ... @@ -722,6 +722,7 @@ 722 722 723 723 **Example: **AT+TDC=30000. Means set interval to 30 seconds 724 724 763 + 725 725 * Downlink Payload (prefix 0x01): 726 726 727 727 (% class="box infomessage" %) ... ... @@ -729,6 +729,8 @@ 729 729 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 730 730 ))) 731 731 771 + 772 + 732 732 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 733 733 734 734 Set work mode. ... ... @@ -742,6 +742,7 @@ 742 742 743 743 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 744 744 786 + 745 745 * Downlink Payload (prefix 0x0A): 746 746 747 747 (% class="box infomessage" %) ... ... @@ -749,6 +749,8 @@ 749 749 **0x0A aa ~/~/ Same as AT+MOD=aa** 750 750 ))) 751 751 794 + 795 + 752 752 ==== 3.4.2.3 Poll an uplink ==== 753 753 754 754 * AT Command: ... ... @@ -755,6 +755,7 @@ 755 755 756 756 There is no AT Command to poll uplink 757 757 802 + 758 758 * Downlink Payload (prefix 0x08): 759 759 760 760 (% class="box infomessage" %) ... ... @@ -764,9 +764,11 @@ 764 764 765 765 **Example**: 0x08FF, ask device to send an Uplink 766 766 812 + 813 + 767 767 ==== 3.4.2.4 Enable Trigger Mode ==== 768 768 769 -Use of trigger mode, please check [[ADDMOD6>> path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]816 +Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 770 770 771 771 * AT Command: 772 772 ... ... @@ -779,6 +779,7 @@ 779 779 780 780 0: Disable Trigger Mode 781 781 829 + 782 782 * Downlink Payload (prefix 0x0A 06): 783 783 784 784 (% class="box infomessage" %) ... ... @@ -786,6 +786,8 @@ 786 786 **0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 787 787 ))) 788 788 837 + 838 + 789 789 ==== 3.4.2.5 Poll trigger settings ==== 790 790 791 791 Poll trigger settings, ... ... @@ -794,6 +794,7 @@ 794 794 795 795 There is no AT Command for this feature. 796 796 847 + 797 797 * Downlink Payload (prefix 0x AB 06): 798 798 799 799 (% class="box infomessage" %) ... ... @@ -801,6 +801,8 @@ 801 801 **0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 802 802 ))) 803 803 855 + 856 + 804 804 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 805 805 806 806 Enable Disable DI1/DI2/DI2 as trigger, ... ... @@ -812,6 +812,7 @@ 812 812 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 813 813 ))) 814 814 868 + 815 815 **Example:** 816 816 817 817 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) ... ... @@ -823,6 +823,8 @@ 823 823 **0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 824 824 ))) 825 825 880 + 881 + 826 826 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 827 827 828 828 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -838,10 +838,12 @@ 838 838 839 839 b : delay timing. 840 840 897 + 841 841 **Example:** 842 842 843 843 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 844 844 902 + 845 845 * Downlink Payload (prefix 0x09 01 ): 846 846 847 847 (% class="box infomessage" %) ... ... @@ -849,6 +849,8 @@ 849 849 **0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 850 850 ))) 851 851 910 + 911 + 852 852 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 853 853 854 854 Set DI2 trigger. ... ... @@ -864,10 +864,12 @@ 864 864 865 865 b : delay timing. 866 866 927 + 867 867 **Example:** 868 868 869 869 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 870 870 932 + 871 871 * Downlink Payload (prefix 0x09 02 ): 872 872 873 873 (% class="box infomessage" %) ... ... @@ -875,9 +875,11 @@ 875 875 **0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 876 876 ))) 877 877 940 + 941 + 878 878 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 879 879 880 -Set current trigger , base on AC port. See [[trigger mode>> path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]944 +Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 881 881 882 882 * AT Command: 883 883 ... ... @@ -886,31 +886,37 @@ 886 886 **AT+ACLIM. ** 887 887 ))) 888 888 953 + 889 889 * Downlink Payload (prefix 0xAA 01 ): 890 890 891 891 (% class="box infomessage" %) 892 892 ((( 893 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>> url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**958 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 894 894 ))) 895 895 961 + 962 + 896 896 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 897 897 898 -Set current trigger , base on AV port. See [[trigger mode>> url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]965 +Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 899 899 900 900 * AT Command: 901 901 902 902 (% class="box infomessage" %) 903 903 ((( 904 -**AT+AVLIM. See [[trigger mode>> url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**971 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 905 905 ))) 906 906 974 + 907 907 * Downlink Payload (prefix 0xAA 00 ): 908 908 909 909 (% class="box infomessage" %) 910 910 ((( 911 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>> url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] **979 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 912 912 ))) 913 913 982 + 983 + 914 914 ==== 3.4.2.11 Trigger – Set minimum interval ==== 915 915 916 916 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. ... ... @@ -922,6 +922,7 @@ 922 922 **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 923 923 ))) 924 924 995 + 925 925 * Downlink Payload (prefix 0xAC ): 926 926 927 927 (% class="box infomessage" %) ... ... @@ -929,6 +929,8 @@ 929 929 **0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 930 930 ))) 931 931 1003 + 1004 + 932 932 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 933 933 934 934 * AT Command: ... ... @@ -935,6 +935,7 @@ 935 935 936 936 There is no AT Command to control Digital Output 937 937 1011 + 938 938 * Downlink Payload (prefix 0x02): 939 939 940 940 (% class="box infomessage" %) ... ... @@ -961,6 +961,7 @@ 961 961 ))) 962 962 963 963 1038 + 964 964 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 965 965 966 966 * AT Command: ... ... @@ -967,6 +967,7 @@ 967 967 968 968 There is no AT Command to control Digital Output 969 969 1045 + 970 970 * Downlink Payload (prefix 0xA9): 971 971 972 972 (% class="box infomessage" %) ... ... @@ -986,18 +986,22 @@ 986 986 987 987 00: DO pins will change to an inverter state after timeout 988 988 1065 + 989 989 (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status: 990 990 991 991 [[image:image-20220524093238-6.png]] 992 992 1070 + 993 993 (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status: 994 994 995 995 [[image:image-20220524093328-7.png]] 996 996 1075 + 997 997 (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status: 998 998 999 999 [[image:image-20220524093351-8.png]] 1000 1000 1080 + 1001 1001 (% style="color:#4f81bd" %)**Sixth and Seventh Byte**: 1002 1002 1003 1003 Latching time. Unit: ms ... ... @@ -1004,6 +1004,7 @@ 1004 1004 1005 1005 Device will upload a packet if downlink code executes successfully. 1006 1006 1087 + 1007 1007 **Example payload:** 1008 1008 1009 1009 **~1. A9 01 01 01 01 07 D0** ... ... @@ -1023,6 +1023,7 @@ 1023 1023 DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low 1024 1024 1025 1025 1107 + 1026 1026 === 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 1027 1027 1028 1028 * AT Command: ... ... @@ -1029,6 +1029,7 @@ 1029 1029 1030 1030 There is no AT Command to control Relay Output 1031 1031 1114 + 1032 1032 * Downlink Payload (prefix 0x03): 1033 1033 1034 1034 (% class="box infomessage" %) ... ... @@ -1051,6 +1051,7 @@ 1051 1051 Device will upload a packet if downlink code executes successfully. 1052 1052 1053 1053 1137 + 1054 1054 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1055 1055 1056 1056 * AT Command: ... ... @@ -1057,6 +1057,7 @@ 1057 1057 1058 1058 There is no AT Command to control Relay Output 1059 1059 1144 + 1060 1060 * Downlink Payload (prefix 0x05): 1061 1061 1062 1062 (% class="box infomessage" %) ... ... @@ -1074,14 +1074,17 @@ 1074 1074 1075 1075 00: Relays will change to an inverter state after timeout 1076 1076 1162 + 1077 1077 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1078 1078 1079 1079 [[image:image-20220524093831-10.png]] 1080 1080 1167 + 1081 1081 (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms 1082 1082 1083 1083 Device will upload a packet if downlink code executes successfully. 1084 1084 1172 + 1085 1085 **Example payload:** 1086 1086 1087 1087 **~1. 05 01 11 07 D0** ... ... @@ -1101,17 +1101,19 @@ 1101 1101 Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO. 1102 1102 1103 1103 1192 + 1104 1104 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1105 1105 1106 -When voltage exceed the threshold, count. Feature see [[MOD4>> path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]1195 +When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1107 1107 1108 1108 * AT Command: 1109 1109 1110 1110 (% class="box infomessage" %) 1111 1111 ((( 1112 -**AT+VOLMAX ~/~/ See [[MOD4>> path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]**1201 +**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1113 1113 ))) 1114 1114 1204 + 1115 1115 * Downlink Payload (prefix 0xA5): 1116 1116 1117 1117 (% class="box infomessage" %) ... ... @@ -1119,6 +1119,8 @@ 1119 1119 **0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1120 1120 ))) 1121 1121 1212 + 1213 + 1122 1122 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1123 1123 1124 1124 * AT Command: ... ... @@ -1136,6 +1136,7 @@ 1136 1136 1137 1137 Bb cc dd ee: number to be set 1138 1138 1231 + 1139 1139 * Downlink Payload (prefix 0xA8): 1140 1140 1141 1141 (% class="box infomessage" %) ... ... @@ -1143,6 +1143,8 @@ 1143 1143 **0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1144 1144 ))) 1145 1145 1239 + 1240 + 1146 1146 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1147 1147 1148 1148 Clear counting for counting mode ... ... @@ -1161,6 +1161,8 @@ 1161 1161 **0x A6 01 ~/~/ clear all counting,** 1162 1162 ))) 1163 1163 1259 + 1260 + 1164 1164 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1165 1165 1166 1166 * AT Command: ... ... @@ -1177,42 +1177,61 @@ 1177 1177 **0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1178 1178 ))) 1179 1179 1277 +((( 1180 1180 range: aa bb cc:0 to 16777215, (unit:second) 1181 1181 1280 + 1281 +))) 1282 + 1283 + 1182 1182 == 3.5 Integrate with Mydevice == 1183 1183 1184 1184 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: 1185 1185 1186 -**Step 1**: Be sure that your device is programmed and properly connected to the network at this time. 1288 +((( 1289 +(% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the network at this time. 1290 +))) 1187 1187 1188 -**Step 2**: To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps: 1292 +((( 1293 +(% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps: 1294 +))) 1189 1189 1190 1190 [[image:1653356737703-362.png||height="232" width="732"]] 1191 1191 1192 1192 [[image:image-20220524094641-11.png||height="390" width="723"]] 1193 1193 1300 + 1194 1194 [[image:image-20220524094641-12.png||height="402" width="718"]] 1195 1195 1196 -**Step 3**: Create an account or log in Mydevices. 1197 1197 1198 -**Step 4**:SearchLT-22222-L(forbothLT-22222-L / LT-33222-L) andadd DevEUI.(% style="display:none" %)1304 +(% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. 1199 1199 1306 +(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %) 1307 + 1200 1200 Search under The things network 1201 1201 1202 1202 [[image:1653356838789-523.png||height="337" width="740"]] 1203 1203 1312 + 1313 + 1204 1204 After added, the sensor data arrive TTN, it will also arrive and show in Mydevices. 1205 1205 1206 1206 [[image:image-20220524094909-1.png||height="335" width="729"]] 1207 1207 1318 + 1208 1208 [[image:image-20220524094909-2.png||height="337" width="729"]] 1209 1209 1321 + 1210 1210 [[image:image-20220524094909-3.png||height="338" width="727"]] 1211 1211 1324 + 1212 1212 [[image:image-20220524094909-4.png||height="339" width="728"]](% style="display:none" %) 1213 1213 1327 + 1214 1214 [[image:image-20220524094909-5.png||height="341" width="734"]] 1215 1215 1330 + 1331 + 1216 1216 == 3.6 Interface Detail == 1217 1217 1218 1218 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === ... ... @@ -1221,6 +1221,8 @@ 1221 1221 1222 1222 [[image:1653356991268-289.png]] 1223 1223 1340 + 1341 + 1224 1224 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1225 1225 1226 1226 ((( ... ... @@ -1236,51 +1236,106 @@ 1236 1236 [[image:1653357170703-587.png]] 1237 1237 1238 1238 ((( 1357 +((( 1239 1239 When use need to connect a device to the DI port, both DI1+ and DI1- must be connected. 1240 1240 ))) 1360 +))) 1241 1241 1362 +((( 1363 + 1364 +))) 1242 1242 1243 -**Example1**: Connect to a Low active sensor. 1366 +((( 1367 +(% style="color:blue" %)**Example1**(%%): Connect to a Low active sensor. 1368 +))) 1244 1244 1370 +((( 1245 1245 This type of sensor will output a low signal GND when active. 1372 +))) 1246 1246 1247 -* Connect sensor’s output to DI1- 1248 -* Connect sensor’s VCC to DI1+. 1374 +* ((( 1375 +Connect sensor’s output to DI1- 1376 +))) 1377 +* ((( 1378 +Connect sensor’s VCC to DI1+. 1379 +))) 1249 1249 1250 -So when sensor active, the current between NEC2501 pin1 and pin2 is: 1381 +((( 1382 +So when sensor active, the current between NEC2501 pin1 and pin2 is: 1383 +))) 1251 1251 1252 -[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]** [[image:image-20220524095628-8.png]] = DI1+ / 1K.** 1385 +((( 1386 +[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 1K.** 1387 +))) 1253 1253 1254 -If DI1+ = 12v, the //IF// = 12mA , So the LT-22222-L will be able to detect this active signal. 1389 +((( 1390 +If DI1+ = 12v, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal. 1391 +))) 1255 1255 1393 +((( 1394 + 1395 +))) 1256 1256 1257 -**Example2**: Connect to a High active sensor. 1397 +((( 1398 +(% style="color:blue" %)**Example2**(%%): Connect to a High active sensor. 1399 +))) 1258 1258 1401 +((( 1259 1259 This type of sensor will output a high signal (example 24v) when active. 1403 +))) 1260 1260 1261 -* Connect sensor’s output to DI1+ 1262 -* Connect sensor’s GND DI1-. 1405 +* ((( 1406 +Connect sensor’s output to DI1+ 1407 +))) 1408 +* ((( 1409 +Connect sensor’s GND DI1-. 1410 +))) 1263 1263 1412 +((( 1264 1264 So when sensor active, the current between NEC2501 pin1 and pin2 is: 1414 +))) 1265 1265 1266 -[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]** [[image:image-20220524095628-8.png]]= DI1+ / 1K.** 1416 +((( 1417 +[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 1K.** 1418 +))) 1267 1267 1268 -If **DI1+ = 24v**, the [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]]** = 24mA , So the LT-22222-L will be able to detect this high active signal. 1420 +((( 1421 +If **DI1+ = 24v**, the[[image:1653968155772-850.png||height="23" width="19"]] 24mA , So the LT-22222-L will be able to detect this high active signal. 1422 +))) 1269 1269 1424 +((( 1425 + 1426 +))) 1270 1270 1271 -**Example3**: Connect to a 220v high active sensor. 1428 +((( 1429 +(% style="color:blue" %)**Example3**(%%): Connect to a 220v high active sensor. 1430 +))) 1272 1272 1432 +((( 1273 1273 Assume user want to monitor an active signal higher than 220v, to make sure not burn the photocoupler 1434 +))) 1274 1274 1275 -* Connect sensor’s output to DI1+ with a serial 50K resistor 1276 -* Connect sensor’s GND DI1-. 1436 +* ((( 1437 +Connect sensor’s output to DI1+ with a serial 50K resistor 1438 +))) 1439 +* ((( 1440 +Connect sensor’s GND DI1-. 1441 +))) 1277 1277 1443 +((( 1278 1278 So when sensor active, the current between NEC2501 pin1 and pin2 is: 1445 +))) 1279 1279 1280 - [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]] = DI1+ / 51K.** 1447 +((( 1448 + [[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 51K.** 1449 +))) 1281 1281 1282 -If sensor output is 220v, the (% id="cke_bm_243359S" style="display:none" %)[[image:image-20220524095628-8.png]](%%) = DI1+ / 51K. = 4.3mA , So the LT-22222-L will be able to detect this high active signal safely. 1451 +((( 1452 +If sensor output is 220v, the [[image:1653968155772-850.png||height="23" width="19"]](% id="cke_bm_243359S" style="display:none" %)[[image:image-20220524095628-8.png]](%%) = DI1+ / 51K. = 4.3mA , So the LT-22222-L will be able to detect this high active signal safely. 1453 +))) 1283 1283 1455 + 1456 + 1284 1284 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1285 1285 1286 1286 NPN output: GND or Float. Max voltage can apply to output pin is 36v. ... ... @@ -1287,12 +1287,15 @@ 1287 1287 1288 1288 [[image:1653357531600-905.png]] 1289 1289 1463 + 1464 + 1290 1290 === 3.6.4 Analog Input Interface === 1291 1291 1292 1292 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: 1293 1293 1294 -**AC2 = (IN2 voltage )/12** 1295 1295 1470 +(% style="color:blue" %)**AC2 = (IN2 voltage )/12** 1471 + 1296 1296 [[image:1653357592296-182.png]] 1297 1297 1298 1298 Example to connect a 4~~20mA sensor ... ... @@ -1299,21 +1299,24 @@ 1299 1299 1300 1300 We take the wind speed sensor as an example for reference only. 1301 1301 1302 -Specifications of the wind speed sensor: 1303 1303 1304 - Red:12~~24v1479 +**Specifications of the wind speed sensor:** 1305 1305 1306 - Yellow:4~~20mA1481 +Red: 12~~24v 1307 1307 1308 - Black:GND1483 +Yellow: 4~~20mA 1309 1309 1485 +Black: GND 1310 1310 1311 -Connection diagram: 1312 1312 1488 +**Connection diagram:** 1489 + 1313 1313 [[image:1653357640609-758.png]] 1314 1314 1315 1315 [[image:1653357648330-671.png||height="155" width="733"]] 1316 1316 1494 + 1495 + 1317 1317 === 3.6.5 Relay Output === 1318 1318 1319 1319 ((( ... ... @@ -1324,10 +1324,13 @@ 1324 1324 1325 1325 [[image:image-20220524100215-10.png||height="382" width="723"]] 1326 1326 1506 + 1507 + 1327 1327 == 3.7 LEDs Indicators == 1328 1328 1329 1329 [[image:image-20220524100748-11.png]] 1330 1330 1512 + 1331 1331 = 4. Use AT Command = 1332 1332 1333 1333 == 4.1 Access AT Command == ... ... @@ -1336,6 +1336,7 @@ 1336 1336 1337 1337 [[image:1653358238933-385.png]] 1338 1338 1521 + 1339 1339 ((( 1340 1340 In PC, User needs to set (% style="color:#4f81bd" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LT. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**)(%%) to active it. As shown below: 1341 1341 ))) ... ... @@ -1342,7 +1342,10 @@ 1342 1342 1343 1343 [[image:1653358355238-883.png]] 1344 1344 1528 + 1529 +((( 1345 1345 More detail AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1531 +))) 1346 1346 1347 1347 ((( 1348 1348 AT+<CMD>? : Help on <CMD> ... ... @@ -1526,14 +1526,20 @@ 1526 1526 1527 1527 ((( 1528 1528 AT+CFG: Print all settings 1715 + 1716 + 1529 1529 ))) 1530 1530 1719 + 1720 + 1531 1531 == 4.2 Common AT Command Sequence == 1532 1532 1533 1533 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1534 1534 1535 1535 ((( 1536 -If device has not joined network yet: 1726 + 1727 + 1728 +**If device has not joined network yet:** 1537 1537 ))) 1538 1538 1539 1539 ((( ... ... @@ -1558,7 +1558,7 @@ 1558 1558 1559 1559 1560 1560 ((( 1561 -If device already joined network: 1753 +**If device already joined network:** 1562 1562 ))) 1563 1563 1564 1564 ((( ... ... @@ -1567,12 +1567,18 @@ 1567 1567 1568 1568 ((( 1569 1569 (% style="background-color:#dcdcdc" %)ATZ 1762 + 1763 + 1570 1570 ))) 1571 1571 1766 + 1767 + 1572 1572 === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) === 1573 1573 1574 1574 ((( 1575 -(% style="background-color:#dcdcdc" %) 123456(%%) Enter Password to have AT access. 1771 + 1772 + 1773 +(% style="background-color:#dcdcdc" %)123456(%%) Enter Password to have AT access. 1576 1576 ))) 1577 1577 1578 1578 ((( ... ... @@ -1580,7 +1580,7 @@ 1580 1580 ))) 1581 1581 1582 1582 ((( 1583 -(% style="background-color:#dcdcdc" %) 123456(%%) 1781 +(% style="background-color:#dcdcdc" %) 123456(%%) Enter Password to have AT access. 1584 1584 ))) 1585 1585 1586 1586 ((( ... ... @@ -1588,39 +1588,41 @@ 1588 1588 ))) 1589 1589 1590 1590 ((( 1591 -(% style="background-color:#dcdcdc" %) AT+NJM=0(%%) Set to ABP mode 1789 +(% style="background-color:#dcdcdc" %) AT+NJM=0(%%) Set to ABP mode 1592 1592 ))) 1593 1593 1594 1594 ((( 1595 -(% style="background-color:#dcdcdc" %) AT+ADR=0(%%) Set the Adaptive Data Rate Off 1793 +(% style="background-color:#dcdcdc" %) AT+ADR=0(%%) Set the Adaptive Data Rate Off 1596 1596 ))) 1597 1597 1598 1598 ((( 1599 -(% style="background-color:#dcdcdc" %) AT+DR=5(%%) Set Data Rate 1797 +(% style="background-color:#dcdcdc" %) AT+DR=5(%%) Set Data Rate 1600 1600 ))) 1601 1601 1602 1602 ((( 1603 -(% style="background-color:#dcdcdc" %) AT+TDC=60000(%%) Set transmit interval to 60 seconds 1801 +(% style="background-color:#dcdcdc" %) AT+TDC=60000(%%) Set transmit interval to 60 seconds 1604 1604 ))) 1605 1605 1606 1606 ((( 1607 -(% style="background-color:#dcdcdc" %) AT+CHS=868400000(%%) Set transmit frequency to 868.4Mhz 1805 +(% style="background-color:#dcdcdc" %) AT+CHS=868400000(%%) Set transmit frequency to 868.4Mhz 1608 1608 ))) 1609 1609 1610 1610 ((( 1611 -(% style="background-color:#dcdcdc" %) AT+RX2FQ=868400000(%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1809 +(% style="background-color:#dcdcdc" %) AT+RX2FQ=868400000(%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1612 1612 ))) 1613 1613 1614 1614 ((( 1615 -(% style="background-color:#dcdcdc" %) AT+RX2DR=5(%%) Set RX2DR to match the downlink DR from server. see below 1813 +(% style="background-color:#dcdcdc" %) AT+RX2DR=5(%%) Set RX2DR to match the downlink DR from server. see below 1616 1616 ))) 1617 1617 1618 1618 ((( 1619 -(% style="background-color:#dcdcdc" %) AT+DADDR=26 01 1A F1 (%%)Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1817 +(% style="background-color:#dcdcdc" %) AT+DADDR=26 01 1A F1 (%%) Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1620 1620 ))) 1621 1621 1622 1622 ((( 1623 -(% style="background-color:#dcdcdc" %) ATZ (%%) Reset MCU 1821 +(% style="background-color:#dcdcdc" %) ATZ (%%) Reset MCU 1822 + 1823 + 1624 1624 ))) 1625 1625 1626 1626 ((( ... ... @@ -1642,6 +1642,7 @@ 1642 1642 1643 1643 ))) 1644 1644 1845 + 1645 1645 === 4.2.3 Change to Class A === 1646 1646 1647 1647 If sensor JOINED ... ... @@ -1648,23 +1648,30 @@ 1648 1648 (% style="background-color:#dcdcdc" %)AT+CLASS=A 1649 1649 ATZ 1650 1650 1852 + 1651 1651 = 5. FAQ = 1652 1652 1653 1653 == 5.1 How to upgrade the image? == 1654 1654 1857 + 1655 1655 The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to: 1656 1656 1657 1657 * Support new features 1658 1658 * For bug fix 1659 1659 * Change LoRaWAN bands. 1863 + 1660 1660 Below shows the hardware connection for how to upload an image to the LT: 1661 -* [[image:1653359603330-121.png]] 1662 1662 1866 +[[image:1653359603330-121.png]] 1867 + 1868 + 1663 1663 ((( 1664 -**Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1665 -**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1666 -**Step3: **Open flashloader; choose the correct COM port to update. 1667 -**For LT-22222-L**: 1870 +(% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1871 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1872 +(% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update. 1873 + 1874 + 1875 +(% style="color:blue" %)**For LT-22222-L**(%%): 1668 1668 Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1669 1669 ))) 1670 1670 ... ... @@ -1674,21 +1674,27 @@ 1674 1674 1675 1675 [[image:image-20220524104033-15.png]] 1676 1676 1885 + 1677 1677 (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1678 1678 1679 1679 [[image:1653360054704-518.png||height="186" width="745"]] 1680 1680 1890 + 1681 1681 ((( 1682 1682 ((( 1893 + 1894 + 1683 1683 == 5.2 How to change the LoRa Frequency Bands/Region? == 1684 1684 ))) 1685 1685 ))) 1686 1686 1687 1687 ((( 1688 -User can follow the introduction for [[how to upgrade image>> path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H5.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download.1900 +User can follow the introduction for [[how to upgrade image>>||anchor="H5.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. 1689 1689 ))) 1690 1690 1691 1691 ((( 1904 + 1905 + 1692 1692 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 1693 1693 ))) 1694 1694 ... ... @@ -1701,6 +1701,8 @@ 1701 1701 ((( 1702 1702 ((( 1703 1703 Assume we have a LG02 working in the frequency 868400000 now , below is the step. 1918 + 1919 + 1704 1704 ))) 1705 1705 ))) 1706 1706 ... ... @@ -1716,23 +1716,25 @@ 1716 1716 (% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN. 1717 1717 ))) 1718 1718 1935 + 1719 1719 ((( 1720 1720 (% style="color:#4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 1721 1721 ))) 1722 1722 1723 1723 ((( 1724 -(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access. 1725 -(% style="background-color:#dcdcdc" %)AT+FDR 1726 -(% style="background-color:#dcdcdc" %)123456 1727 -(% style="background-color:#dcdcdc" %)AT+NJM=0 (%%)Set to ABP mode 1728 -(% style="background-color:#dcdcdc" %)AT+ADR=0 (%%)Set the Adaptive Data Rate Off 1729 -(% style="background-color:#dcdcdc" %)AT+DR=5 (%%) Set Data Rate (Set AT+DR=3 for 915 band) 1730 -(% style="background-color:#dcdcdc" %)AT+TDC=60000 1731 -(% style="background-color:#dcdcdc" %)AT+CHS=868400000 1732 -(% style="background-color:#dcdcdc" %)AT+DADDR=26 01 1A F1(%%) Set Device Address to 26 01 1A F1 1733 -(% style="background-color:#dcdcdc" %)ATZ 1941 +(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access. 1942 +(% style="background-color:#dcdcdc" %)AT+FDR(%%) Reset Parameters to Factory Default, Keys Reserve 1943 +(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access. 1944 +(% style="background-color:#dcdcdc" %)AT+NJM=0 (%%) Set to ABP mode 1945 +(% style="background-color:#dcdcdc" %)AT+ADR=0 (%%) Set the Adaptive Data Rate Off 1946 +(% style="background-color:#dcdcdc" %)AT+DR=5 (%%) Set Data Rate (Set AT+DR=3 for 915 band) 1947 +(% style="background-color:#dcdcdc" %)AT+TDC=60000 (%%) Set transmit interval to 60 seconds 1948 +(% style="background-color:#dcdcdc" %)AT+CHS=868400000(%%) Set transmit frequency to 868.4Mhz 1949 +(% style="background-color:#dcdcdc" %)AT+DADDR=26 01 1A F1(%%) Set Device Address to 26 01 1A F1 1950 +(% style="background-color:#dcdcdc" %)ATZ (%%) Reset MCU 1734 1734 ))) 1735 1735 1953 + 1736 1736 ((( 1737 1737 As shown in below: 1738 1738 ))) ... ... @@ -1739,187 +1739,103 @@ 1739 1739 1740 1740 [[image:1653360498588-932.png||height="485" width="726"]] 1741 1741 1960 + 1742 1742 == 5.4 Can I see counting event in Serial? == 1743 1743 1744 1744 ((( 1745 1745 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn’t support AT+DEBUG. User can update to latest firmware first. 1746 -))) 1747 1747 1748 -((( 1749 -= 6. Trouble Shooting = 1750 -))) 1751 1751 1752 -((( 1753 -((( 1754 -== 6.1 Downlink doesn’t work, how to solve it? == 1755 -))) 1756 -))) 1967 +== 5.5 Can i use point to point communication for LT-22222-L? == 1757 1757 1758 -((( 1759 -Please see this link for how to debug: 1760 - 1761 -[[http:~~/~~/8.211.40.43:8080/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/>>http://8.211.40.43:8080/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]] 1969 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1762 1762 ))) 1763 1763 1764 1764 ((( 1765 -[[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#How_it_work>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#How_it_work]] 1766 -))) 1973 + 1767 1767 1768 -((( 1769 -== 6.2 Have trouble to upload image. == 1975 += 6. Trouble Shooting = 1770 1770 ))) 1771 1771 1772 1772 ((( 1773 -See this link for trouble shooting: 1774 -))) 1775 - 1776 1776 ((( 1777 - [[http:~~/~~/wiki.dragino.com/index.php?title=Firmware_Upgrade_Trouble_Shooting#UART_upgrade_trouble_shooting>>url:http://wiki.dragino.com/index.php?title=Firmware_Upgrade_Trouble_Shooting#UART_upgrade_trouble_shooting]]1980 +== 6.1 Downlink doesn’t work, how to solve it? == 1778 1778 ))) 1779 - 1780 -((( 1781 -== 6.3 Why I can’t join TTN in US915 /AU915 bands? == 1782 1782 ))) 1783 1783 1784 1784 ((( 1785 - It might be about the channels mapping.Please see this link for detail:1985 +Please see this link for how to debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H5.1Howitwork"]] 1786 1786 ))) 1787 1787 1788 1788 ((( 1789 -[[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band]] 1790 -))) 1989 + 1791 1791 1792 -((( 1793 -= 7. Order Info = 1991 +== 6.2 Have trouble to upload image. == 1794 1794 ))) 1795 1795 1796 1796 ((( 1797 -((( 1798 -(% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1995 +See this link for trouble shooting: [[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]] 1799 1799 ))) 1800 -))) 1801 1801 1802 1802 ((( 1803 -((( 1804 -(% style="color:#4f81bd" %)**XXX:** 1805 -))) 1806 -))) 1999 + 1807 1807 1808 -((( 1809 -* ((( 1810 -(% style="color:#4f81bd" %)**EU433**(%%): LT with frequency bands EU433 2001 +== 6.3 Why I can’t join TTN in US915 /AU915 bands? == 1811 1811 ))) 1812 -))) 1813 1813 1814 1814 ((( 1815 -* ((( 1816 -(% style="color:#4f81bd" %)**EU868**(%%): LT with frequency bands EU868 2005 +It might be about the channels mapping. [[Please see this link for detail>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1817 1817 ))) 1818 -))) 1819 1819 1820 -((( 1821 -* ((( 1822 -(% style="color:#4f81bd" %)**KR920**(%%): LT with frequency bands KR920 1823 -))) 1824 -))) 1825 1825 1826 -((( 1827 -* ((( 1828 -(% style="color:#4f81bd" %)**CN470**(%%): LT with frequency bands CN470 1829 -))) 1830 -))) 1831 1831 1832 -((( 1833 -* ((( 1834 -(% style="color:#4f81bd" %)**AS923**(%%): LT with frequency bands AS923 1835 -))) 1836 -))) 2010 += 7. Order Info = 1837 1837 1838 -((( 1839 -* ((( 1840 -(% style="color:#4f81bd" %)**AU915**(%%): LT with frequency bands AU915 1841 -))) 1842 -))) 1843 1843 1844 -((( 1845 -* ((( 1846 -(% style="color:#4f81bd" %)**US915**(%%): LT with frequency bands US915 1847 -))) 1848 -))) 2013 +(% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1849 1849 1850 -((( 1851 -* ((( 1852 -(% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865 1853 -))) 1854 -))) 1855 1855 1856 -((( 1857 -* ((( 1858 -(% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 1859 -))) 2016 +(% style="color:#4f81bd" %)**XXX:** 1860 1860 2018 +* (% style="color:#4f81bd" %)**EU433**(%%): LT with frequency bands EU433 2019 +* (% style="color:#4f81bd" %)**EU868**(%%): LT with frequency bands EU868 2020 +* (% style="color:#4f81bd" %)**KR920**(%%): LT with frequency bands KR920 2021 +* (% style="color:#4f81bd" %)**CN470**(%%): LT with frequency bands CN470 2022 +* (% style="color:#4f81bd" %)**AS923**(%%): LT with frequency bands AS923 2023 +* (% style="color:#4f81bd" %)**AU915**(%%): LT with frequency bands AU915 2024 +* (% style="color:#4f81bd" %)**US915**(%%): LT with frequency bands US915 2025 +* (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865 2026 +* (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 2027 + 1861 1861 = 8. Packing Info = 1862 -))) 1863 1863 1864 -((( 1865 -((( 2030 + 1866 1866 **Package Includes**: 1867 -))) 1868 -))) 1869 1869 1870 -((( 1871 -((( 1872 1872 * LT-22222-L I/O Controller x 1 1873 1873 * Stick Antenna for LoRa RF part x 1 1874 1874 * Bracket for controller x1 1875 1875 * Program cable x 1 1876 -))) 1877 -))) 1878 1878 1879 -((( 1880 -((( 1881 1881 **Dimension and weight**: 1882 -))) 1883 -))) 1884 1884 1885 -((( 1886 -((( 1887 1887 * Device Size: 13.5 x 7 x 3 cm 1888 1888 * Device Weight: 105g 1889 1889 * Package Size / pcs : 14.5 x 8 x 5 cm 1890 1890 * Weight / pcs : 170g 1891 -))) 1892 -))) 1893 1893 1894 -((( 1895 1895 = 9. Support = 1896 -))) 1897 1897 1898 1898 * ((( 1899 -((( 1900 1900 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1901 1901 ))) 1902 -))) 1903 1903 * ((( 1904 -((( 1905 -Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to 2051 +Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1906 1906 ))) 1907 -))) 1908 1908 1909 -((( 1910 -((( 1911 - [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1912 -))) 1913 - 1914 -((( 1915 1915 = 10. Reference = 1916 1916 1917 -* Product Page: 1918 - 1919 -LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 1920 - 2056 +* LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 1921 1921 * [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]] 1922 1922 * [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1923 1923 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 1924 -))) 1925 -)))
- 1653968155772-850.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +886 bytes - Content
- 1653968164738-884.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +886 bytes - Content
- 1653968172068-832.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +886 bytes - Content
- image-20220531113415-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +172 bytes - Content