... ... @@ -313,7 +313,9 @@
313 313  
314 314  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
315 315  
316 +(((
316 316  Total : 11 bytes payload
318 +)))
317 317  
318 318  [[image:image-20220523180452-3.png]]
319 319  
... ... @@ -327,53 +327,77 @@
327 327  * FIRST: Indicate this is the first packet after join network.
328 328  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
329 329  
332 +(((
330 330  (% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L.
334 +)))
331 331  
336 +(((
332 332  **To use counting mode, please run:**
338 +)))
333 333  
334 334  (% class="box infomessage" %)
335 335  (((
342 +(((
336 336  **AT+MOD=2**
337 337  )))
345 +)))
338 338  
339 339  (% class="box infomessage" %)
340 340  (((
349 +(((
341 341  **ATZ**
342 342  )))
352 +)))
343 343  
354 +(((
344 344  (% style="color:#4f81bd" %)**AT Commands for counting:**
356 +)))
345 345  
358 +(((
346 346  **For LT22222-L:**
360 +)))
347 347  
348 348  (% class="box infomessage" %)
349 349  (((
364 +(((
350 350  **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) **
351 351  )))
367 +)))
352 352  
353 353  (% class="box infomessage" %)
354 354  (((
371 +(((
355 355  **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) **
356 356  )))
374 +)))
357 357  
358 358  (% class="box infomessage" %)
359 359  (((
378 +(((
360 360  **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) **
361 361  )))
381 +)))
362 362  
363 363  (% class="box infomessage" %)
364 364  (((
385 +(((
365 365  **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) **
366 366  )))
388 +)))
367 367  
368 368  (% class="box infomessage" %)
369 369  (((
392 +(((
370 370  **AT+SETCNT=1,60   (Set COUNT1 value to 60)**
371 371  )))
395 +)))
372 372  
373 373  (% class="box infomessage" %)
374 374  (((
399 +(((
375 375  **AT+SETCNT=2,60   (Set COUNT2 value to 60)**
376 376  )))
402 +)))
377 377  
378 378  === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI ===
379 379  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved