... ... @@ -845,7 +845,11 @@
845 845  
846 846  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
847 847  
848 -[[image:image-20220524093351-8.png]]
848 +(% border="1" style="background-color:#f7faff" %)
849 +|Second Byte|Status
850 +|0x01|DO3 set to low
851 +|0x00|DO3 set to high
852 +|0x11|DO3 NO Action
849 849  
850 850  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
851 851  
... ... @@ -853,129 +853,147 @@
853 853  
854 854  Device will upload a packet if downlink code executes successfully.
855 855  
856 -**Example payload:**
857 857  
858 -**~1. A9 01 01 01 01 07 D0**
859 859  
862 +Example payload:
863 +
864 +1. A9 01 01 01 01 07 D0
865 +
860 860  DO1 pin & DO2 pin & DO3 pin will be set to Low, last 2 seconds, then change back to original state.
861 861  
862 -**2. A9 01 00 01 11 07 D0**
863 863  
869 +1. A9 01 00 01 11 07 D0
870 +
864 864  DO1 pin set high, DO2 pin set low, DO3 pin no action, last 2 seconds, then change back to original state.
865 865  
866 -**3. A9 00 00 00 00 07 D0**
867 867  
874 +1. A9 00 00 00 00 07 D0
875 +
868 868  DO1 pin & DO2 pin & DO3 pin will be set to high, last 2 seconds, then both change to low.
869 869  
870 -**4. A9 00 11 01 00 07 D0**
871 871  
879 +1. A9 00 11 01 00 07 D0
880 +
872 872  DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low
873 873  
874 874  
875 -=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
876 876  
885 +
886 +==== Relay ~-~- Control Relay Output RO1/RO2 ====
887 +
877 877  * AT Command:
878 878  
879 879  There is no AT Command to control Relay Output
880 880  
892 +
881 881  * Downlink Payload (prefix 0x03):
882 882  
883 -(% class="box infomessage" %)
884 -(((
885 -**0x03 aa bb     ~/~/ Set RO1/RO2 output**
886 -)))
895 +0x03 aa bb     ~/~/ Set RO1/RO2 output
887 887  
888 -(((
889 889  If payload = 0x030100, it means set RO1 to close and RO2 to open.
890 -)))
891 891  
892 -(((
893 893  01: Close ,  00: Open , 11: No action
894 -)))
895 895  
896 -(((
897 -[[image:image-20220524093724-9.png]]
898 -)))
901 +(% border="1" style="background-color:#f7faff" %)
902 +|Downlink Code|RO1|RO2
903 +|03  00  11|Open|No Action
904 +|03  01  11|Close|No Action
905 +|03  11  00|No Action|Open
906 +|03  11  01|No Action|Close
907 +|03  00  00|Open|Open
908 +|03  01  01|Close|Close
909 +|03  01  00|Close|Open
910 +|03  00  01|Open|Close
899 899  
900 900  Device will upload a packet if downlink code executes successfully.
901 901  
902 902  
903 -==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
915 +==== Relay ~-~- Control Relay Output RO1/RO2 with time control ====
904 904  
905 905  * AT Command:
906 906  
907 907  There is no AT Command to control Relay Output
908 908  
921 +
909 909  * Downlink Payload (prefix 0x05):
910 910  
911 -(% class="box infomessage" %)
912 -(((
913 -**0x05 aa bb cc dd     ~/~/ Set RO1/RO2 relay with time control:**
914 -)))
924 +0x05 aa bb cc dd     ~/~/ Set RO1/RO2 relay with time control:
915 915  
916 916  This is to control the relay output time of relay. Include four bytes:
917 917  
918 -(% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05)
928 +**First Byte:** Type code (0x05)
919 919  
920 -(% style="color:#4f81bd" %)**Second Byte(aa)**(%%): Inverter Mode
930 +**Second Byte(aa)**: Inverter Mode
921 921  
922 922  01: Relays will change back to original state after timeout.
923 923  
924 924  00: Relays will change to an inverter state after timeout
925 925  
926 -(% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
927 927  
928 -[[image:image-20220524093831-10.png]]
937 +**Third Byte(bb)**: Control Method and Ports status:
929 929  
930 -(% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
939 +(% border="1" style="background-color:#f7faff" %)
940 +|Value|Status
941 +|0x11|RO1 and RO2 to NO
942 +|0x10|RO2 to NO, RO1 to NC
943 +|0x01|RO2 to NC, RO1 to NO
944 +|0x00|RO1 and RO2 to NC.
945 +|0x20|RO1 No Action, RO2 to NC
946 +|0x21|RO1 No Action, RO2 to NO
947 +|0x02|RO1 to NC, RO2 No Action
948 +|0x12|RO1 to NO, RO2 No Action
931 931  
950 +**Fourth / Fifth Bytes (cc)**: Latching time. Unit: ms
951 +
932 932  Device will upload a packet if downlink code executes successfully.
933 933  
954 +
955 +
934 934  **Example payload:**
935 935  
936 -**~1. 05 01 11 07 D0**
958 +1. 05 01 11 07 D0
937 937  
938 938  Relay1 and Relay 2 will be set to NO , last 2 seconds, then change back to original state.
939 939  
940 -**2. 05 01 10 07 D0**
941 941  
963 +1. 05 01 10 07 D0
964 +
942 942  Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then both change back to original state.
943 943  
944 -**3. 05 00 01 07 D0**
945 945  
968 +1. 05 00 01 07 D0
969 +
946 946  Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then relay change to NO, Relay2 change to NC.
947 947  
948 -**4. 05 00 00 07 D0**
949 949  
973 +1. 05 00 00 07 D0
974 +
950 950  Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO.
951 951  
952 952  
953 -==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
954 954  
955 -When voltage exceed the threshold, count. Feature see [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]
956 956  
980 +
981 +
982 +==== Counting ~-~- Voltage threshold counting ====
983 +
984 +When voltage exceed the threshold, count. Feature see [[MOD4>>path:#MOD4]]
985 +
957 957  * AT Command:
958 958  
959 -(% class="box infomessage" %)
960 -(((
961 -**AT+VOLMAX    ~/~/ See [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]**
962 -)))
988 +AT+VOLMAX    ~/~/ See [[MOD4>>path:#MOD4]]
963 963  
990 +
964 964  * Downlink Payload (prefix 0xA5):
965 965  
966 -(% class="box infomessage" %)
967 -(((
968 -**0xA5 aa bb cc   ~/~/ Same as AT+VOLMAX=(aa bb),cc**
969 -)))
993 +0xA5 aa bb cc   ~/~/ Same as AT+VOLMAX=(aa bb),cc
970 970  
971 -==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
972 972  
996 +==== Counting ~-~- Pre-configure the Count Number ====
997 +
973 973  * AT Command:
974 974  
975 -(% class="box infomessage" %)
976 -(((
977 -**AT+SETCNT=aa,(bb cc dd ee) **
978 -)))
1000 +AT+SETCNT=aa,(bb cc dd ee)
979 979  
980 980  aa: 1: Set count1,
981 981  
... ... @@ -985,46 +985,41 @@
985 985  
986 986  Bb cc dd ee: number to be set
987 987  
1010 +
988 988  * Downlink Payload (prefix 0xA8):
989 989  
990 -(% class="box infomessage" %)
991 -(((
992 -**0x A8 aa bb cc dd ee     ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)**
993 -)))
1013 +0x A8 aa bb cc dd ee     ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)
994 994  
995 -==== 3.4.2.18 Counting ~-~- Clear Counting ====
996 996  
1016 +
1017 +
1018 +
1019 +==== Counting ~-~- Clear Counting ====
1020 +
997 997  Clear counting for counting mode
998 998  
999 999  * AT Command:
1000 1000  
1001 -(% class="box infomessage" %)
1002 -(((
1003 -**AT+CLRCOUNT ~/~/ clear all counting**
1004 -)))
1025 +AT+CLRCOUNT ~/~/ clear all counting
1005 1005  
1027 +
1006 1006  * Downlink Payload (prefix 0xA6):
1007 1007  
1008 -(% class="box infomessage" %)
1009 -(((
1010 -**0x A6 01     ~/~/ clear all counting,**
1011 -)))
1030 +0x A6 01     ~/~/ clear all counting,
1012 1012  
1013 -==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1014 1014  
1033 +
1034 +
1035 +==== Counting ~-~- Change counting mode save time ====
1036 +
1015 1015  * AT Command:
1016 1016  
1017 -(% class="box infomessage" %)
1018 -(((
1019 -**AT+COUTIME=60  ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)**
1020 -)))
1039 +AT+COUTIME=60  ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)
1021 1021  
1041 +
1022 1022  * Downlink Payload (prefix 0xA7):
1023 1023  
1024 -(% class="box infomessage" %)
1025 -(((
1026 -**0x A7 aa bb cc     ~/~/ same as AT+COUTIME =aa bb cc,**
1027 -)))
1044 +0x A7 aa bb cc     ~/~/ same as AT+COUTIME =aa bb cc,
1028 1028  
1029 1029  range: aa bb cc:0 to 16777215,  (unit:second)
1030 1030  