... ... @@ -558,87 +558,76 @@
558 558  
559 559  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>http://8.211.40.43:8080/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
560 560  
561 -=== 3.4.2 Sensor related commands ===
561 +=== Sensor related commands ===
562 562  
563 -==== 3.4.2.1 Set Transmit Interval ====
564 564  
564 +==== Set Transmit Interval ====
565 +
565 565  Set device uplink interval.
566 566  
567 567  * AT Command:
568 568  
569 -(% class="box infomessage" %)
570 -(((
571 -**AT+TDC=N **
572 -)))
570 +AT+TDC=N
573 573  
574 -**Example: **AT+TDC=30000. Means set interval to 30 seconds
572 +Example: AT+TDC=30000. Means set interval to 30 seconds
575 575  
574 +
576 576  * Downlink Payload (prefix 0x01):
577 577  
578 -(% class="box infomessage" %)
579 -(((
580 -**0x01 aa bb cc     ~/~/ Same as AT+TDC=0x(aa bb cc)**
581 -)))
577 +0x01 aa bb cc     ~/~/ Same as AT+TDC=0x(aa bb cc)
582 582  
583 -==== 3.4.2.2 Set Work Mode (AT+MOD) ====
584 584  
580 +==== Set Work Mode (AT+MOD) ====
581 +
585 585  Set work mode.
586 586  
587 587  * AT Command:
588 588  
589 -(% class="box infomessage" %)
590 -(((
591 -**AT+MOD=N  **
592 -)))
586 +AT+MOD=N 
593 593  
594 -**Example**: AT+MOD=2. Set work mode to Double DI counting mode
588 +Example: AT+MOD=2. Set work mode to Double DI counting mode
595 595  
590 +
596 596  * Downlink Payload (prefix 0x0A):
597 597  
598 -(% class="box infomessage" %)
599 -(((
600 -**0x0A aa     ~/~/ Same as AT+MOD=aa**
601 -)))
593 +0x0A aa     ~/~/ Same as AT+MOD=aa
602 602  
603 -==== 3.4.2.3 Poll an uplink ====
604 604  
596 +
597 +==== Poll an uplink ====
598 +
605 605  * AT Command:
606 606  
607 607  There is no AT Command to poll uplink
608 608  
603 +
609 609  * Downlink Payload (prefix 0x08):
610 610  
611 -(% class="box infomessage" %)
612 -(((
613 -**0x08 FF     ~/~/ Poll an uplink,**
614 -)))
606 +0x08 FF     ~/~/ Poll an uplink,
615 615  
616 -**Example**: 0x08FF, ask device to send an Uplink
608 +Example: 0x08FF, ask device to send an Uplink
617 617  
618 -==== 3.4.2.4 Enable Trigger Mode ====
619 619  
620 -Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
611 +==== Enable Trigger Mode ====
621 621  
613 +Use of trigger mode, please check [[ADDMOD6>>path:#MOD6]]
614 +
622 622  * AT Command:
623 623  
624 -(% class="box infomessage" %)
625 -(((
626 -**AT+ADDMOD6=1 or 0**
627 -)))
617 +AT+ADDMOD6=1 or 0
628 628  
629 629  1: Enable Trigger Mode
630 630  
631 631  0: Disable Trigger Mode
632 632  
623 +
633 633  * Downlink Payload (prefix 0x0A 06):
634 634  
635 -(% class="box infomessage" %)
636 -(((
637 -**0x0A 06 aa     ~/~/ Same as AT+ADDMOD6=aa,**
638 -)))
626 +0x0A 06 aa     ~/~/ Same as AT+ADDMOD6=aa,
639 639  
640 -==== 3.4.2.5 Poll trigger settings ====
641 641  
629 +==== Poll trigger settings ====
630 +
642 642  Poll trigger settings,
643 643  
644 644  * AT Command:
... ... @@ -645,337 +645,339 @@
645 645  
646 646  There is no AT Command for this feature.
647 647  
637 +
648 648  * Downlink Payload (prefix 0x AB 06):
649 649  
650 -(% class="box infomessage" %)
651 -(((
652 -**0xAB 06  ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command**
653 -)))
640 +0xAB 06  ~/~/ Poll trigger settings, device will uplink [[trigger settings>>path:#Trigger_Settings]] once receive this command
654 654  
655 -==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
656 656  
643 +==== Enable / Disable DI1/DI2/DI3 as trigger ====
644 +
657 657  Enable Disable DI1/DI2/DI2 as trigger,
658 658  
659 659  * AT Command:
660 660  
661 -(% class="box infomessage" %)
662 -(((
663 -**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
664 -)))
649 +Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
665 665  
666 -**Example:**
651 +Example:
667 667  
668 668  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
669 669  
655 +
656 +
670 670  * Downlink Payload (prefix 0xAA 02):
671 671  
672 -(% class="box infomessage" %)
673 -(((
674 -**0xAA 02 aa bb  ~/~/ Same as AT+DTRI=aa,bb**
675 -)))
659 +0xAA 02 aa bb  ~/~/ Same as AT+DTRI=aa,bb
676 676  
677 -==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
678 678  
662 +
663 +==== Trigger1 – Set DI1 or DI3 as trigger ====
664 +
679 679  Set DI1 or DI3(for LT-33222-L) trigger.
680 680  
681 681  * AT Command:
682 682  
683 -(% class="box infomessage" %)
684 -(((
685 -**AT+TRIG1=a,b**
686 -)))
669 +AT+TRIG1=a,b
687 687  
688 688  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
689 689  
690 690  b : delay timing.
691 691  
692 -**Example:**
675 +Example:
693 693  
694 694  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
695 695  
679 +
696 696  * Downlink Payload (prefix 0x09 01 ):
697 697  
698 -(% class="box infomessage" %)
699 -(((
700 -**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
701 -)))
682 +0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)
702 702  
703 -==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
704 704  
685 +==== Trigger2 – Set DI2 as trigger ====
686 +
705 705  Set DI2 trigger.
706 706  
707 707  * AT Command:
708 708  
709 -(% class="box infomessage" %)
710 -(((
711 -**AT+TRIG2=a,b**
712 -)))
691 +AT+TRIG2=a,b
713 713  
714 714  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
715 715  
716 716  b : delay timing.
717 717  
718 -**Example:**
697 +Example:
719 719  
720 720  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
721 721  
701 +
722 722  * Downlink Payload (prefix 0x09 02 ):
723 723  
724 -(% class="box infomessage" %)
725 -(((
726 -**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
727 -)))
704 +0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)
728 728  
729 -==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
730 730  
731 -Set current trigger , base on AC port. See [[trigger mode>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
707 +==== Trigger Set AC (current) as trigger ====
732 732  
709 +Set current trigger , base on AC port. See [[trigger mode>>path:#MOD6]]
710 +
733 733  * AT Command:
734 734  
735 -(% class="box infomessage" %)
736 -(((
737 -**AT+ACLIM. **
738 -)))
713 +AT+ACLIM. See [[trigger mode>>path:#MOD6]]
739 739  
715 +
740 740  * Downlink Payload (prefix 0xAA 01 ):
741 741  
742 -(% class="box infomessage" %)
743 -(((
744 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
745 -)))
718 +0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>path:#MOD6]]
746 746  
747 -==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
748 748  
749 -Set current trigger , base on AV port. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
721 +==== Trigger Set AV (voltage) as trigger ====
750 750  
723 +Set current trigger , base on AV port. See [[trigger mode>>path:#MOD6]]
724 +
751 751  * AT Command:
752 752  
753 -(% class="box infomessage" %)
754 -(((
755 -**AT+AVLIM. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
756 -)))
727 +AT+AVLIM. See [[trigger mode>>path:#MOD6]]
757 757  
729 +
758 758  * Downlink Payload (prefix 0xAA 00 ):
759 759  
760 -(% class="box infomessage" %)
761 -(((
762 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] **
763 -)))
732 +0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>path:#MOD6]]
764 764  
765 -==== 3.4.2.11 Trigger – Set minimum interval ====
734 +==== Trigger – Set minimum interval ====
766 766  
767 767  Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger.
768 768  
769 769  * AT Command:
770 770  
771 -(% class="box infomessage" %)
772 -(((
773 -**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
774 -)))
740 +AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.
775 775  
742 +
776 776  * Downlink Payload (prefix 0xAC ):
777 777  
778 -(% class="box infomessage" %)
779 -(((
780 -**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)**
781 -)))
745 +0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
782 782  
783 -==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
784 784  
748 +==== DO ~-~- Control Digital Output DO1/DO2/DO3 ====
749 +
785 785  * AT Command:
786 786  
787 787  There is no AT Command to control Digital Output
788 788  
754 +
789 789  * Downlink Payload (prefix 0x02):
790 790  
791 -(% class="box infomessage" %)
792 -(((
793 -**0x02 aa bb cc     ~/~/ Set DO1/DO2/DO3 output**
794 -)))
757 +0x02 aa bb cc     ~/~/ Set DO1/DO2/DO3 output
795 795  
796 -(((
797 797  If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low.
798 -)))
799 799  
800 -(((
801 801  01: Low,  00: High ,  11: No action
802 -)))
803 803  
804 -[[image:image-20220524092754-5.png]]
763 +(% border="1" style="background-color:#f7faff" %)
764 +|Downlink Code|DO1|DO2|DO3
765 +|02  01  00  11|Low|High|No Action
766 +|02  00  11  01|High|No Action|Low
767 +|02  11  01  00|No Action|Low|High
805 805  
806 -(((
807 -(% style="color:red" %)Note: For LT-22222-L, there is no DO3, the last byte can use any value.
808 -)))
769 +Note: For LT-22222-L, there is no DO3, the last byte can use any value.
809 809  
810 -(((
811 -(% style="color:red" %)Device will upload a packet if downlink code executes successfully.
812 -)))
771 +Device will upload a packet if downlink code executes successfully.
813 813  
814 814  
815 -==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
816 816  
775 +
776 +
777 +==== DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
778 +
817 817  * AT Command:
818 818  
819 819  There is no AT Command to control Digital Output
820 820  
783 +
821 821  * Downlink Payload (prefix 0xA9):
822 822  
823 -(% class="box infomessage" %)
824 -(((
825 -**0xA9 aa bb cc     ~/~/ Set DO1/DO2/DO3 output with time control**
826 -)))
786 +0xA9 aa bb cc     ~/~/ Set DO1/DO2/DO3 output with time control
827 827  
828 828  This is to control the digital output time of DO pin. Include four bytes:
829 829  
830 -(% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9)
790 +**First Byte:** Type code (0xA9)
831 831  
832 -(% style="color:#4f81bd" %)**Second Byte**(%%): Inverter Mode
792 +**Second Byte**: Inverter Mode
833 833  
834 834  01: DO pins will change back to original state after timeout.
835 835  
836 836  00: DO pins will change to an inverter state after timeout 
837 837  
838 -(% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
839 839  
840 -[[image:image-20220524093238-6.png]]
799 +**Third Byte**: Control Method and Ports status:
841 841  
842 -(% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
801 +(% border="1" style="background-color:#f7faff" %)
802 +|Second Byte|Status
803 +|0x01|DO1 set to low
804 +|0x00|DO1 set to high
805 +|0x11|DO1 NO Action
843 843  
844 -[[image:image-20220524093328-7.png]]
807 +**Fourth Byte**: Control Method and Ports status:
845 845  
846 -(% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
809 +(% border="1" style="background-color:#f7faff" %)
810 +|Second Byte|Status
811 +|0x01|DO2 set to low
812 +|0x00|DO2 set to high
813 +|0x11|DO2 NO Action
847 847  
848 -[[image:image-20220524093351-8.png]]
815 +**Fifth Byte**: Control Method and Ports status:
849 849  
850 -(% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
817 +(% border="1" style="background-color:#f7faff" %)
818 +|Second Byte|Status
819 +|0x01|DO3 set to low
820 +|0x00|DO3 set to high
821 +|0x11|DO3 NO Action
851 851  
823 +**Sixth and Seventh Byte**:
824 +
852 852   Latching time. Unit: ms
853 853  
854 854  Device will upload a packet if downlink code executes successfully.
855 855  
856 -**Example payload:**
857 857  
858 -**~1. A9 01 01 01 01 07 D0**
859 859  
831 +Example payload:
832 +
833 +1. A9 01 01 01 01 07 D0
834 +
860 860  DO1 pin & DO2 pin & DO3 pin will be set to Low, last 2 seconds, then change back to original state.
861 861  
862 -**2. A9 01 00 01 11 07 D0**
863 863  
838 +1. A9 01 00 01 11 07 D0
839 +
864 864  DO1 pin set high, DO2 pin set low, DO3 pin no action, last 2 seconds, then change back to original state.
865 865  
866 -**3. A9 00 00 00 00 07 D0**
867 867  
843 +1. A9 00 00 00 00 07 D0
844 +
868 868  DO1 pin & DO2 pin & DO3 pin will be set to high, last 2 seconds, then both change to low.
869 869  
870 -**4. A9 00 11 01 00 07 D0**
871 871  
848 +1. A9 00 11 01 00 07 D0
849 +
872 872  DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low
873 873  
874 874  
875 -=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
876 876  
854 +
855 +==== Relay ~-~- Control Relay Output RO1/RO2 ====
856 +
877 877  * AT Command:
878 878  
879 879  There is no AT Command to control Relay Output
880 880  
861 +
881 881  * Downlink Payload (prefix 0x03):
882 882  
883 -(% class="box infomessage" %)
884 -(((
885 -**0x03 aa bb     ~/~/ Set RO1/RO2 output**
886 -)))
864 +0x03 aa bb     ~/~/ Set RO1/RO2 output
887 887  
888 -(((
889 889  If payload = 0x030100, it means set RO1 to close and RO2 to open.
890 -)))
891 891  
892 -(((
893 893  01: Close ,  00: Open , 11: No action
894 -)))
895 895  
896 -(((
897 -[[image:image-20220524093724-9.png]]
898 -)))
870 +(% border="1" style="background-color:#f7faff" %)
871 +|Downlink Code|RO1|RO2
872 +|03  00  11|Open|No Action
873 +|03  01  11|Close|No Action
874 +|03  11  00|No Action|Open
875 +|03  11  01|No Action|Close
876 +|03  00  00|Open|Open
877 +|03  01  01|Close|Close
878 +|03  01  00|Close|Open
879 +|03  00  01|Open|Close
899 899  
900 900  Device will upload a packet if downlink code executes successfully.
901 901  
902 902  
903 -==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
884 +==== Relay ~-~- Control Relay Output RO1/RO2 with time control ====
904 904  
905 905  * AT Command:
906 906  
907 907  There is no AT Command to control Relay Output
908 908  
890 +
909 909  * Downlink Payload (prefix 0x05):
910 910  
911 -(% class="box infomessage" %)
912 -(((
913 -**0x05 aa bb cc dd     ~/~/ Set RO1/RO2 relay with time control:**
914 -)))
893 +0x05 aa bb cc dd     ~/~/ Set RO1/RO2 relay with time control:
915 915  
916 916  This is to control the relay output time of relay. Include four bytes:
917 917  
918 -(% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05)
897 +**First Byte:** Type code (0x05)
919 919  
920 -(% style="color:#4f81bd" %)**Second Byte(aa)**(%%): Inverter Mode
899 +**Second Byte(aa)**: Inverter Mode
921 921  
922 922  01: Relays will change back to original state after timeout.
923 923  
924 924  00: Relays will change to an inverter state after timeout
925 925  
926 -(% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
927 927  
928 -[[image:image-20220524093831-10.png]]
906 +**Third Byte(bb)**: Control Method and Ports status:
929 929  
930 -(% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
908 +(% border="1" style="background-color:#f7faff" %)
909 +|Value|Status
910 +|0x11|RO1 and RO2 to NO
911 +|0x10|RO2 to NO, RO1 to NC
912 +|0x01|RO2 to NC, RO1 to NO
913 +|0x00|RO1 and RO2 to NC.
914 +|0x20|RO1 No Action, RO2 to NC
915 +|0x21|RO1 No Action, RO2 to NO
916 +|0x02|RO1 to NC, RO2 No Action
917 +|0x12|RO1 to NO, RO2 No Action
931 931  
919 +**Fourth / Fifth Bytes (cc)**: Latching time. Unit: ms
920 +
932 932  Device will upload a packet if downlink code executes successfully.
933 933  
923 +
924 +
934 934  **Example payload:**
935 935  
936 -**~1. 05 01 11 07 D0**
927 +1. 05 01 11 07 D0
937 937  
938 938  Relay1 and Relay 2 will be set to NO , last 2 seconds, then change back to original state.
939 939  
940 -**2. 05 01 10 07 D0**
941 941  
932 +1. 05 01 10 07 D0
933 +
942 942  Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then both change back to original state.
943 943  
944 -**3. 05 00 01 07 D0**
945 945  
937 +1. 05 00 01 07 D0
938 +
946 946  Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then relay change to NO, Relay2 change to NC.
947 947  
948 -**4. 05 00 00 07 D0**
949 949  
942 +1. 05 00 00 07 D0
943 +
950 950  Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO.
951 951  
952 952  
953 -==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
954 954  
955 -When voltage exceed the threshold, count. Feature see [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]
956 956  
949 +
950 +
951 +==== Counting ~-~- Voltage threshold counting ====
952 +
953 +When voltage exceed the threshold, count. Feature see [[MOD4>>path:#MOD4]]
954 +
957 957  * AT Command:
958 958  
959 -(% class="box infomessage" %)
960 -(((
961 -**AT+VOLMAX    ~/~/ See [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]**
962 -)))
957 +AT+VOLMAX    ~/~/ See [[MOD4>>path:#MOD4]]
963 963  
959 +
964 964  * Downlink Payload (prefix 0xA5):
965 965  
966 -(% class="box infomessage" %)
967 -(((
968 -**0xA5 aa bb cc   ~/~/ Same as AT+VOLMAX=(aa bb),cc**
969 -)))
962 +0xA5 aa bb cc   ~/~/ Same as AT+VOLMAX=(aa bb),cc
970 970  
971 -==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
972 972  
965 +==== Counting ~-~- Pre-configure the Count Number ====
966 +
973 973  * AT Command:
974 974  
975 -(% class="box infomessage" %)
976 -(((
977 -**AT+SETCNT=aa,(bb cc dd ee) **
978 -)))
969 +AT+SETCNT=aa,(bb cc dd ee)
979 979  
980 980  aa: 1: Set count1,
981 981  
... ... @@ -985,46 +985,41 @@
985 985  
986 986  Bb cc dd ee: number to be set
987 987  
979 +
988 988  * Downlink Payload (prefix 0xA8):
989 989  
990 -(% class="box infomessage" %)
991 -(((
992 -**0x A8 aa bb cc dd ee     ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)**
993 -)))
982 +0x A8 aa bb cc dd ee     ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)
994 994  
995 -==== 3.4.2.18 Counting ~-~- Clear Counting ====
996 996  
985 +
986 +
987 +
988 +==== Counting ~-~- Clear Counting ====
989 +
997 997  Clear counting for counting mode
998 998  
999 999  * AT Command:
1000 1000  
1001 -(% class="box infomessage" %)
1002 -(((
1003 -**AT+CLRCOUNT ~/~/ clear all counting**
1004 -)))
994 +AT+CLRCOUNT ~/~/ clear all counting
1005 1005  
996 +
1006 1006  * Downlink Payload (prefix 0xA6):
1007 1007  
1008 -(% class="box infomessage" %)
1009 -(((
1010 -**0x A6 01     ~/~/ clear all counting,**
1011 -)))
999 +0x A6 01     ~/~/ clear all counting,
1012 1012  
1013 -==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1014 1014  
1002 +
1003 +
1004 +==== Counting ~-~- Change counting mode save time ====
1005 +
1015 1015  * AT Command:
1016 1016  
1017 -(% class="box infomessage" %)
1018 -(((
1019 -**AT+COUTIME=60  ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)**
1020 -)))
1008 +AT+COUTIME=60  ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)
1021 1021  
1010 +
1022 1022  * Downlink Payload (prefix 0xA7):
1023 1023  
1024 -(% class="box infomessage" %)
1025 -(((
1026 -**0x A7 aa bb cc     ~/~/ same as AT+COUTIME =aa bb cc,**
1027 -)))
1013 +0x A7 aa bb cc     ~/~/ same as AT+COUTIME =aa bb cc,
1028 1028  
1029 1029  range: aa bb cc:0 to 16777215,  (unit:second)
1030 1030  
1653356737703-362.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -42.1 KB
Content
image-20220524092754-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -7.8 KB
Content
image-20220524093238-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -6.0 KB
Content
image-20220524093328-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -6.1 KB
Content
image-20220524093351-8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -6.2 KB
Content
image-20220524093724-9.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -14.3 KB
Content
image-20220524093831-10.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -15.2 KB
Content