... ... @@ -845,11 +845,7 @@
845 845  
846 846  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
847 847  
848 -(% border="1" style="background-color:#f7faff" %)
849 -|Second Byte|Status
850 -|0x01|DO3 set to low
851 -|0x00|DO3 set to high
852 -|0x11|DO3 NO Action
848 +[[image:image-20220524093351-8.png]]
853 853  
854 854  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
855 855  
... ... @@ -857,147 +857,129 @@
857 857  
858 858  Device will upload a packet if downlink code executes successfully.
859 859  
856 +**Example payload:**
860 860  
858 +**~1. A9 01 01 01 01 07 D0**
861 861  
862 -Example payload:
863 -
864 -1. A9 01 01 01 01 07 D0
865 -
866 866  DO1 pin & DO2 pin & DO3 pin will be set to Low, last 2 seconds, then change back to original state.
867 867  
862 +**2. A9 01 00 01 11 07 D0**
868 868  
869 -1. A9 01 00 01 11 07 D0
870 -
871 871  DO1 pin set high, DO2 pin set low, DO3 pin no action, last 2 seconds, then change back to original state.
872 872  
866 +**3. A9 00 00 00 00 07 D0**
873 873  
874 -1. A9 00 00 00 00 07 D0
875 -
876 876  DO1 pin & DO2 pin & DO3 pin will be set to high, last 2 seconds, then both change to low.
877 877  
870 +**4. A9 00 11 01 00 07 D0**
878 878  
879 -1. A9 00 11 01 00 07 D0
880 -
881 881  DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low
882 882  
883 883  
875 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
884 884  
885 -
886 -==== Relay ~-~- Control Relay Output RO1/RO2 ====
887 -
888 888  * AT Command:
889 889  
890 890  There is no AT Command to control Relay Output
891 891  
892 -
893 893  * Downlink Payload (prefix 0x03):
894 894  
895 -0x03 aa bb     ~/~/ Set RO1/RO2 output
883 +(% class="box infomessage" %)
884 +(((
885 +**0x03 aa bb     ~/~/ Set RO1/RO2 output**
886 +)))
896 896  
888 +(((
897 897  If payload = 0x030100, it means set RO1 to close and RO2 to open.
890 +)))
898 898  
892 +(((
899 899  01: Close ,  00: Open , 11: No action
894 +)))
900 900  
901 -(% border="1" style="background-color:#f7faff" %)
902 -|Downlink Code|RO1|RO2
903 -|03  00  11|Open|No Action
904 -|03  01  11|Close|No Action
905 -|03  11  00|No Action|Open
906 -|03  11  01|No Action|Close
907 -|03  00  00|Open|Open
908 -|03  01  01|Close|Close
909 -|03  01  00|Close|Open
910 -|03  00  01|Open|Close
896 +(((
897 +[[image:image-20220524093724-9.png]]
898 +)))
911 911  
912 912  Device will upload a packet if downlink code executes successfully.
913 913  
914 914  
915 -==== Relay ~-~- Control Relay Output RO1/RO2 with time control ====
903 +==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
916 916  
917 917  * AT Command:
918 918  
919 919  There is no AT Command to control Relay Output
920 920  
921 -
922 922  * Downlink Payload (prefix 0x05):
923 923  
924 -0x05 aa bb cc dd     ~/~/ Set RO1/RO2 relay with time control:
911 +(% class="box infomessage" %)
912 +(((
913 +**0x05 aa bb cc dd     ~/~/ Set RO1/RO2 relay with time control:**
914 +)))
925 925  
926 926  This is to control the relay output time of relay. Include four bytes:
927 927  
928 -**First Byte:** Type code (0x05)
918 +(% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05)
929 929  
930 -**Second Byte(aa)**: Inverter Mode
920 +(% style="color:#4f81bd" %)**Second Byte(aa)**(%%): Inverter Mode
931 931  
932 932  01: Relays will change back to original state after timeout.
933 933  
934 934  00: Relays will change to an inverter state after timeout
935 935  
926 +(% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
936 936  
937 -**Third Byte(bb)**: Control Method and Ports status:
928 +[[image:image-20220524093831-10.png]]
938 938  
939 -(% border="1" style="background-color:#f7faff" %)
940 -|Value|Status
941 -|0x11|RO1 and RO2 to NO
942 -|0x10|RO2 to NO, RO1 to NC
943 -|0x01|RO2 to NC, RO1 to NO
944 -|0x00|RO1 and RO2 to NC.
945 -|0x20|RO1 No Action, RO2 to NC
946 -|0x21|RO1 No Action, RO2 to NO
947 -|0x02|RO1 to NC, RO2 No Action
948 -|0x12|RO1 to NO, RO2 No Action
930 +(% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
949 949  
950 -**Fourth / Fifth Bytes (cc)**: Latching time. Unit: ms
951 -
952 952  Device will upload a packet if downlink code executes successfully.
953 953  
954 -
955 -
956 956  **Example payload:**
957 957  
958 -1. 05 01 11 07 D0
936 +**~1. 05 01 11 07 D0**
959 959  
960 960  Relay1 and Relay 2 will be set to NO , last 2 seconds, then change back to original state.
961 961  
940 +**2. 05 01 10 07 D0**
962 962  
963 -1. 05 01 10 07 D0
964 -
965 965  Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then both change back to original state.
966 966  
944 +**3. 05 00 01 07 D0**
967 967  
968 -1. 05 00 01 07 D0
969 -
970 970  Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then relay change to NO, Relay2 change to NC.
971 971  
948 +**4. 05 00 00 07 D0**
972 972  
973 -1. 05 00 00 07 D0
974 -
975 975  Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO.
976 976  
977 977  
953 +==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
978 978  
955 +When voltage exceed the threshold, count. Feature see [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]
979 979  
980 -
981 -
982 -==== Counting ~-~- Voltage threshold counting ====
983 -
984 -When voltage exceed the threshold, count. Feature see [[MOD4>>path:#MOD4]]
985 -
986 986  * AT Command:
987 987  
988 -AT+VOLMAX    ~/~/ See [[MOD4>>path:#MOD4]]
959 +(% class="box infomessage" %)
960 +(((
961 +**AT+VOLMAX    ~/~/ See [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]**
962 +)))
989 989  
990 -
991 991  * Downlink Payload (prefix 0xA5):
992 992  
993 -0xA5 aa bb cc   ~/~/ Same as AT+VOLMAX=(aa bb),cc
966 +(% class="box infomessage" %)
967 +(((
968 +**0xA5 aa bb cc   ~/~/ Same as AT+VOLMAX=(aa bb),cc**
969 +)))
994 994  
971 +==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
995 995  
996 -==== Counting ~-~- Pre-configure the Count Number ====
997 -
998 998  * AT Command:
999 999  
1000 -AT+SETCNT=aa,(bb cc dd ee)
975 +(% class="box infomessage" %)
976 +(((
977 +**AT+SETCNT=aa,(bb cc dd ee) **
978 +)))
1001 1001  
1002 1002  aa: 1: Set count1,
1003 1003  
... ... @@ -1007,41 +1007,46 @@
1007 1007  
1008 1008  Bb cc dd ee: number to be set
1009 1009  
1010 -
1011 1011  * Downlink Payload (prefix 0xA8):
1012 1012  
1013 -0x A8 aa bb cc dd ee     ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)
990 +(% class="box infomessage" %)
991 +(((
992 +**0x A8 aa bb cc dd ee     ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)**
993 +)))
1014 1014  
995 +==== 3.4.2.18 Counting ~-~- Clear Counting ====
1015 1015  
1016 -
1017 -
1018 -
1019 -==== Counting ~-~- Clear Counting ====
1020 -
1021 1021  Clear counting for counting mode
1022 1022  
1023 1023  * AT Command:
1024 1024  
1025 -AT+CLRCOUNT ~/~/ clear all counting
1001 +(% class="box infomessage" %)
1002 +(((
1003 +**AT+CLRCOUNT ~/~/ clear all counting**
1004 +)))
1026 1026  
1027 -
1028 1028  * Downlink Payload (prefix 0xA6):
1029 1029  
1030 -0x A6 01     ~/~/ clear all counting,
1008 +(% class="box infomessage" %)
1009 +(((
1010 +**0x A6 01     ~/~/ clear all counting,**
1011 +)))
1031 1031  
1013 +==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1032 1032  
1033 -
1034 -
1035 -==== Counting ~-~- Change counting mode save time ====
1036 -
1037 1037  * AT Command:
1038 1038  
1039 -AT+COUTIME=60  ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)
1017 +(% class="box infomessage" %)
1018 +(((
1019 +**AT+COUTIME=60  ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)**
1020 +)))
1040 1040  
1041 -
1042 1042  * Downlink Payload (prefix 0xA7):
1043 1043  
1044 -0x A7 aa bb cc     ~/~/ same as AT+COUTIME =aa bb cc,
1024 +(% class="box infomessage" %)
1025 +(((
1026 +**0x A7 aa bb cc     ~/~/ same as AT+COUTIME =aa bb cc,**
1027 +)))
1045 1045  
1046 1046  range: aa bb cc:0 to 16777215,  (unit:second)
1047 1047  
1653356737703-362.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +42.1 KB
Content
image-20220524093351-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +6.2 KB
Content
image-20220524093724-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +14.3 KB
Content
image-20220524093831-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +15.2 KB
Content
image-20220524094641-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +136.2 KB
Content
image-20220524094641-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +69.1 KB
Content