... ... @@ -580,7 +580,6 @@
580 580  **0x01 aa bb cc     ~/~/ Same as AT+TDC=0x(aa bb cc)**
581 581  )))
582 582  
583 -
584 584  ==== 3.4.2.2 Set Work Mode (AT+MOD) ====
585 585  
586 586  Set work mode.
... ... @@ -616,7 +616,6 @@
616 616  
617 617  **Example**: 0x08FF, ask device to send an Uplink
618 618  
619 -
620 620  ==== 3.4.2.4 Enable Trigger Mode ====
621 621  
622 622  Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
... ... @@ -632,14 +632,15 @@
632 632  
633 633  0: Disable Trigger Mode
634 634  
635 -
636 636  * Downlink Payload (prefix 0x0A 06):
637 637  
638 -0x0A 06 aa     ~/~/ Same as AT+ADDMOD6=aa,
635 +(% class="box infomessage" %)
636 +(((
637 +**0x0A 06 aa     ~/~/ Same as AT+ADDMOD6=aa,**
638 +)))
639 639  
640 +==== 3.4.2.5 Poll trigger settings ====
640 640  
641 -==== Poll trigger settings ====
642 -
643 643  Poll trigger settings,
644 644  
645 645  * AT Command:
... ... @@ -646,339 +646,337 @@
646 646  
647 647  There is no AT Command for this feature.
648 648  
649 -
650 650  * Downlink Payload (prefix 0x AB 06):
651 651  
652 -0xAB 06  ~/~/ Poll trigger settings, device will uplink [[trigger settings>>path:#Trigger_Settings]] once receive this command
650 +(% class="box infomessage" %)
651 +(((
652 +**0xAB 06  ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command**
653 +)))
653 653  
655 +==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
654 654  
655 -==== Enable / Disable DI1/DI2/DI3 as trigger ====
656 -
657 657  Enable Disable DI1/DI2/DI2 as trigger,
658 658  
659 659  * AT Command:
660 660  
661 -Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
661 +(% class="box infomessage" %)
662 +(((
663 +**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
664 +)))
662 662  
663 -Example:
666 +**Example:**
664 664  
665 665  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
666 666  
667 -
668 -
669 669  * Downlink Payload (prefix 0xAA 02):
670 670  
671 -0xAA 02 aa bb  ~/~/ Same as AT+DTRI=aa,bb
672 +(% class="box infomessage" %)
673 +(((
674 +**0xAA 02 aa bb  ~/~/ Same as AT+DTRI=aa,bb**
675 +)))
672 672  
677 +==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
673 673  
674 -
675 -==== Trigger1 – Set DI1 or DI3 as trigger ====
676 -
677 677  Set DI1 or DI3(for LT-33222-L) trigger.
678 678  
679 679  * AT Command:
680 680  
681 -AT+TRIG1=a,b
683 +(% class="box infomessage" %)
684 +(((
685 +**AT+TRIG1=a,b**
686 +)))
682 682  
683 683  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
684 684  
685 685  b : delay timing.
686 686  
687 -Example:
692 +**Example:**
688 688  
689 689  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
690 690  
691 -
692 692  * Downlink Payload (prefix 0x09 01 ):
693 693  
694 -0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)
698 +(% class="box infomessage" %)
699 +(((
700 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
701 +)))
695 695  
703 +==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
696 696  
697 -==== Trigger2 – Set DI2 as trigger ====
698 -
699 699  Set DI2 trigger.
700 700  
701 701  * AT Command:
702 702  
703 -AT+TRIG2=a,b
709 +(% class="box infomessage" %)
710 +(((
711 +**AT+TRIG2=a,b**
712 +)))
704 704  
705 705  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
706 706  
707 707  b : delay timing.
708 708  
709 -Example:
718 +**Example:**
710 710  
711 711  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
712 712  
713 -
714 714  * Downlink Payload (prefix 0x09 02 ):
715 715  
716 -0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)
724 +(% class="box infomessage" %)
725 +(((
726 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
727 +)))
717 717  
729 +==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
718 718  
719 -==== Trigger Set AC (current) as trigger ====
731 +Set current trigger , base on AC port. See [[trigger mode>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
720 720  
721 -Set current trigger , base on AC port. See [[trigger mode>>path:#MOD6]]
722 -
723 723  * AT Command:
724 724  
725 -AT+ACLIM. See [[trigger mode>>path:#MOD6]]
735 +(% class="box infomessage" %)
736 +(((
737 +**AT+ACLIM. **
738 +)))
726 726  
727 -
728 728  * Downlink Payload (prefix 0xAA 01 ):
729 729  
730 -0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>path:#MOD6]]
742 +(% class="box infomessage" %)
743 +(((
744 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
745 +)))
731 731  
747 +==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
732 732  
733 -==== Trigger Set AV (voltage) as trigger ====
749 +Set current trigger , base on AV port. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
734 734  
735 -Set current trigger , base on AV port. See [[trigger mode>>path:#MOD6]]
736 -
737 737  * AT Command:
738 738  
739 -AT+AVLIM. See [[trigger mode>>path:#MOD6]]
753 +(% class="box infomessage" %)
754 +(((
755 +**AT+AVLIM. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
756 +)))
740 740  
741 -
742 742  * Downlink Payload (prefix 0xAA 00 ):
743 743  
744 -0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>path:#MOD6]]
760 +(% class="box infomessage" %)
761 +(((
762 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] **
763 +)))
745 745  
746 -==== Trigger – Set minimum interval ====
765 +==== 3.4.2.11 Trigger – Set minimum interval ====
747 747  
748 748  Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger.
749 749  
750 750  * AT Command:
751 751  
752 -AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.
771 +(% class="box infomessage" %)
772 +(((
773 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
774 +)))
753 753  
754 -
755 755  * Downlink Payload (prefix 0xAC ):
756 756  
757 -0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
778 +(% class="box infomessage" %)
779 +(((
780 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)**
781 +)))
758 758  
783 +==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
759 759  
760 -==== DO ~-~- Control Digital Output DO1/DO2/DO3 ====
761 -
762 762  * AT Command:
763 763  
764 764  There is no AT Command to control Digital Output
765 765  
766 -
767 767  * Downlink Payload (prefix 0x02):
768 768  
769 -0x02 aa bb cc     ~/~/ Set DO1/DO2/DO3 output
791 +(% class="box infomessage" %)
792 +(((
793 +**0x02 aa bb cc     ~/~/ Set DO1/DO2/DO3 output**
794 +)))
770 770  
796 +(((
771 771  If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low.
798 +)))
772 772  
800 +(((
773 773  01: Low,  00: High ,  11: No action
802 +)))
774 774  
775 -(% border="1" style="background-color:#f7faff" %)
776 -|Downlink Code|DO1|DO2|DO3
777 -|02  01  00  11|Low|High|No Action
778 -|02  00  11  01|High|No Action|Low
779 -|02  11  01  00|No Action|Low|High
804 +[[image:image-20220524092754-5.png]]
780 780  
781 -Note: For LT-22222-L, there is no DO3, the last byte can use any value.
806 +(((
807 +(% style="color:red" %)Note: For LT-22222-L, there is no DO3, the last byte can use any value.
808 +)))
782 782  
783 -Device will upload a packet if downlink code executes successfully.
810 +(((
811 +(% style="color:red" %)Device will upload a packet if downlink code executes successfully.
812 +)))
784 784  
785 785  
815 +==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
786 786  
787 -
788 -
789 -==== DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
790 -
791 791  * AT Command:
792 792  
793 793  There is no AT Command to control Digital Output
794 794  
795 -
796 796  * Downlink Payload (prefix 0xA9):
797 797  
798 -0xA9 aa bb cc     ~/~/ Set DO1/DO2/DO3 output with time control
823 +(% class="box infomessage" %)
824 +(((
825 +**0xA9 aa bb cc     ~/~/ Set DO1/DO2/DO3 output with time control**
826 +)))
799 799  
800 800  This is to control the digital output time of DO pin. Include four bytes:
801 801  
802 -**First Byte:** Type code (0xA9)
830 +(% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9)
803 803  
804 -**Second Byte**: Inverter Mode
832 +(% style="color:#4f81bd" %)**Second Byte**(%%): Inverter Mode
805 805  
806 806  01: DO pins will change back to original state after timeout.
807 807  
808 808  00: DO pins will change to an inverter state after timeout 
809 809  
838 +(% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
810 810  
811 -**Third Byte**: Control Method and Ports status:
840 +[[image:image-20220524093238-6.png]]
812 812  
813 -(% border="1" style="background-color:#f7faff" %)
814 -|Second Byte|Status
815 -|0x01|DO1 set to low
816 -|0x00|DO1 set to high
817 -|0x11|DO1 NO Action
842 +(% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
818 818  
819 -**Fourth Byte**: Control Method and Ports status:
844 +[[image:image-20220524093328-7.png]]
820 820  
821 -(% border="1" style="background-color:#f7faff" %)
822 -|Second Byte|Status
823 -|0x01|DO2 set to low
824 -|0x00|DO2 set to high
825 -|0x11|DO2 NO Action
846 +(% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
826 826  
827 -**Fifth Byte**: Control Method and Ports status:
848 +[[image:image-20220524093351-8.png]]
828 828  
829 -(% border="1" style="background-color:#f7faff" %)
830 -|Second Byte|Status
831 -|0x01|DO3 set to low
832 -|0x00|DO3 set to high
833 -|0x11|DO3 NO Action
850 +(% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
834 834  
835 -**Sixth and Seventh Byte**:
836 -
837 837   Latching time. Unit: ms
838 838  
839 839  Device will upload a packet if downlink code executes successfully.
840 840  
856 +**Example payload:**
841 841  
858 +**~1. A9 01 01 01 01 07 D0**
842 842  
843 -Example payload:
844 -
845 -1. A9 01 01 01 01 07 D0
846 -
847 847  DO1 pin & DO2 pin & DO3 pin will be set to Low, last 2 seconds, then change back to original state.
848 848  
862 +**2. A9 01 00 01 11 07 D0**
849 849  
850 -1. A9 01 00 01 11 07 D0
851 -
852 852  DO1 pin set high, DO2 pin set low, DO3 pin no action, last 2 seconds, then change back to original state.
853 853  
866 +**3. A9 00 00 00 00 07 D0**
854 854  
855 -1. A9 00 00 00 00 07 D0
856 -
857 857  DO1 pin & DO2 pin & DO3 pin will be set to high, last 2 seconds, then both change to low.
858 858  
870 +**4. A9 00 11 01 00 07 D0**
859 859  
860 -1. A9 00 11 01 00 07 D0
861 -
862 862  DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low
863 863  
864 864  
875 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
865 865  
866 -
867 -==== Relay ~-~- Control Relay Output RO1/RO2 ====
868 -
869 869  * AT Command:
870 870  
871 871  There is no AT Command to control Relay Output
872 872  
873 -
874 874  * Downlink Payload (prefix 0x03):
875 875  
876 -0x03 aa bb     ~/~/ Set RO1/RO2 output
883 +(% class="box infomessage" %)
884 +(((
885 +**0x03 aa bb     ~/~/ Set RO1/RO2 output**
886 +)))
877 877  
888 +(((
878 878  If payload = 0x030100, it means set RO1 to close and RO2 to open.
890 +)))
879 879  
892 +(((
880 880  01: Close ,  00: Open , 11: No action
894 +)))
881 881  
882 -(% border="1" style="background-color:#f7faff" %)
883 -|Downlink Code|RO1|RO2
884 -|03  00  11|Open|No Action
885 -|03  01  11|Close|No Action
886 -|03  11  00|No Action|Open
887 -|03  11  01|No Action|Close
888 -|03  00  00|Open|Open
889 -|03  01  01|Close|Close
890 -|03  01  00|Close|Open
891 -|03  00  01|Open|Close
896 +(((
897 +[[image:image-20220524093724-9.png]]
898 +)))
892 892  
893 893  Device will upload a packet if downlink code executes successfully.
894 894  
895 895  
896 -==== Relay ~-~- Control Relay Output RO1/RO2 with time control ====
903 +==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
897 897  
898 898  * AT Command:
899 899  
900 900  There is no AT Command to control Relay Output
901 901  
902 -
903 903  * Downlink Payload (prefix 0x05):
904 904  
905 -0x05 aa bb cc dd     ~/~/ Set RO1/RO2 relay with time control:
911 +(% class="box infomessage" %)
912 +(((
913 +**0x05 aa bb cc dd     ~/~/ Set RO1/RO2 relay with time control:**
914 +)))
906 906  
907 907  This is to control the relay output time of relay. Include four bytes:
908 908  
909 -**First Byte:** Type code (0x05)
918 +(% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05)
910 910  
911 -**Second Byte(aa)**: Inverter Mode
920 +(% style="color:#4f81bd" %)**Second Byte(aa)**(%%): Inverter Mode
912 912  
913 913  01: Relays will change back to original state after timeout.
914 914  
915 915  00: Relays will change to an inverter state after timeout
916 916  
926 +(% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
917 917  
918 -**Third Byte(bb)**: Control Method and Ports status:
928 +[[image:image-20220524093831-10.png]]
919 919  
920 -(% border="1" style="background-color:#f7faff" %)
921 -|Value|Status
922 -|0x11|RO1 and RO2 to NO
923 -|0x10|RO2 to NO, RO1 to NC
924 -|0x01|RO2 to NC, RO1 to NO
925 -|0x00|RO1 and RO2 to NC.
926 -|0x20|RO1 No Action, RO2 to NC
927 -|0x21|RO1 No Action, RO2 to NO
928 -|0x02|RO1 to NC, RO2 No Action
929 -|0x12|RO1 to NO, RO2 No Action
930 +(% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
930 930  
931 -**Fourth / Fifth Bytes (cc)**: Latching time. Unit: ms
932 -
933 933  Device will upload a packet if downlink code executes successfully.
934 934  
935 -
936 -
937 937  **Example payload:**
938 938  
939 -1. 05 01 11 07 D0
936 +**~1. 05 01 11 07 D0**
940 940  
941 941  Relay1 and Relay 2 will be set to NO , last 2 seconds, then change back to original state.
942 942  
940 +**2. 05 01 10 07 D0**
943 943  
944 -1. 05 01 10 07 D0
945 -
946 946  Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then both change back to original state.
947 947  
944 +**3. 05 00 01 07 D0**
948 948  
949 -1. 05 00 01 07 D0
950 -
951 951  Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then relay change to NO, Relay2 change to NC.
952 952  
948 +**4. 05 00 00 07 D0**
953 953  
954 -1. 05 00 00 07 D0
955 -
956 956  Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO.
957 957  
958 958  
953 +==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
959 959  
955 +When voltage exceed the threshold, count. Feature see [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]
960 960  
961 -
962 -
963 -==== Counting ~-~- Voltage threshold counting ====
964 -
965 -When voltage exceed the threshold, count. Feature see [[MOD4>>path:#MOD4]]
966 -
967 967  * AT Command:
968 968  
969 -AT+VOLMAX    ~/~/ See [[MOD4>>path:#MOD4]]
959 +(% class="box infomessage" %)
960 +(((
961 +**AT+VOLMAX    ~/~/ See [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]**
962 +)))
970 970  
971 -
972 972  * Downlink Payload (prefix 0xA5):
973 973  
974 -0xA5 aa bb cc   ~/~/ Same as AT+VOLMAX=(aa bb),cc
966 +(% class="box infomessage" %)
967 +(((
968 +**0xA5 aa bb cc   ~/~/ Same as AT+VOLMAX=(aa bb),cc**
969 +)))
975 975  
971 +==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
976 976  
977 -==== Counting ~-~- Pre-configure the Count Number ====
978 -
979 979  * AT Command:
980 980  
981 -AT+SETCNT=aa,(bb cc dd ee)
975 +(% class="box infomessage" %)
976 +(((
977 +**AT+SETCNT=aa,(bb cc dd ee) **
978 +)))
982 982  
983 983  aa: 1: Set count1,
984 984  
... ... @@ -988,75 +988,73 @@
988 988  
989 989  Bb cc dd ee: number to be set
990 990  
991 -
992 992  * Downlink Payload (prefix 0xA8):
993 993  
994 -0x A8 aa bb cc dd ee     ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)
990 +(% class="box infomessage" %)
991 +(((
992 +**0x A8 aa bb cc dd ee     ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)**
993 +)))
995 995  
995 +==== 3.4.2.18 Counting ~-~- Clear Counting ====
996 996  
997 -
998 -
999 -
1000 -==== Counting ~-~- Clear Counting ====
1001 -
1002 1002  Clear counting for counting mode
1003 1003  
1004 1004  * AT Command:
1005 1005  
1006 -AT+CLRCOUNT ~/~/ clear all counting
1001 +(% class="box infomessage" %)
1002 +(((
1003 +**AT+CLRCOUNT ~/~/ clear all counting**
1004 +)))
1007 1007  
1008 -
1009 1009  * Downlink Payload (prefix 0xA6):
1010 1010  
1011 -0x A6 01     ~/~/ clear all counting,
1008 +(% class="box infomessage" %)
1009 +(((
1010 +**0x A6 01     ~/~/ clear all counting,**
1011 +)))
1012 1012  
1013 +==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1013 1013  
1014 -
1015 -
1016 -==== Counting ~-~- Change counting mode save time ====
1017 -
1018 1018  * AT Command:
1019 1019  
1020 -AT+COUTIME=60  ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)
1017 +(% class="box infomessage" %)
1018 +(((
1019 +**AT+COUTIME=60  ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)**
1020 +)))
1021 1021  
1022 -
1023 1023  * Downlink Payload (prefix 0xA7):
1024 1024  
1025 -0x A7 aa bb cc     ~/~/ same as AT+COUTIME =aa bb cc,
1024 +(% class="box infomessage" %)
1025 +(((
1026 +**0x A7 aa bb cc     ~/~/ same as AT+COUTIME =aa bb cc,**
1027 +)))
1026 1026  
1027 1027  range: aa bb cc:0 to 16777215,  (unit:second)
1028 1028  
1031 +== 3.5 Integrate with Mydevice ==
1029 1029  
1030 -
1031 -
1032 -1.
1033 -11. Integrate with Mydevice
1034 -
1035 1035  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
1036 1036  
1035 +**Step 1**: Be sure that your device is programmed and properly connected to the network at this time.
1037 1037  
1038 -Step 1: Be sure that your device is programmed and properly connected to the network at this time.
1037 +**Step 2**: To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1039 1039  
1040 -Step 2: To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1039 +[[image:1653356737703-362.png||height="232" width="732"]]
1041 1041  
1041 +[[image:image-20220524094641-11.png||height="390" width="723"]]
1042 1042  
1043 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image010.png]]
1044 1044  
1044 +[[image:image-20220524094641-12.png||height="402" width="718"]]
1045 1045  
1046 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image011.png]]
1047 1047  
1048 1048  
1049 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image012.png]]
1048 +**Step **3: Create an account or log in Mydevices.
1050 1050  
1050 +**Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
1051 1051  
1052 -
1053 -Step 3: Create an account or log in Mydevices.
1054 -
1055 -Step 4: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.
1056 -
1057 1057  Search under The things network
1058 1058  
1059 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image013.png]]
1054 +[[image:1653356838789-523.png]]
1060 1060  
1061 1061  
1062 1062  After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
1653356737703-362.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +42.1 KB
Content
1653356838789-523.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +131.7 KB
Content
image-20220524092754-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +7.8 KB
Content
image-20220524093238-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +6.0 KB
Content
image-20220524093328-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +6.1 KB
Content
image-20220524093351-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +6.2 KB
Content
image-20220524093724-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +14.3 KB
Content
image-20220524093831-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +15.2 KB
Content
image-20220524094641-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +136.2 KB
Content
image-20220524094641-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +69.1 KB
Content
image-20220524094909-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +297.8 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0