Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 8 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -558,76 +558,87 @@ 558 558 559 559 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>http://8.211.40.43:8080/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 560 560 561 -=== Sensor related commands === 561 +=== 3.4.2 Sensor related commands === 562 562 563 +==== 3.4.2.1 Set Transmit Interval ==== 563 563 564 -==== Set Transmit Interval ==== 565 - 566 566 Set device uplink interval. 567 567 568 568 * AT Command: 569 569 570 -AT+TDC=N 569 +(% class="box infomessage" %) 570 +((( 571 +**AT+TDC=N ** 572 +))) 571 571 572 -Example: AT+TDC=30000. Means set interval to 30 seconds 574 +**Example: **AT+TDC=30000. Means set interval to 30 seconds 573 573 574 - 575 575 * Downlink Payload (prefix 0x01): 576 576 577 -0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc) 578 +(% class="box infomessage" %) 579 +((( 580 +**0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 581 +))) 578 578 583 +==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 579 579 580 -==== Set Work Mode (AT+MOD) ==== 581 - 582 582 Set work mode. 583 583 584 584 * AT Command: 585 585 586 -AT+MOD=N 589 +(% class="box infomessage" %) 590 +((( 591 +**AT+MOD=N ** 592 +))) 587 587 588 -Example: AT+MOD=2. Set work mode to Double DI counting mode 594 +**Example**: AT+MOD=2. Set work mode to Double DI counting mode 589 589 590 - 591 591 * Downlink Payload (prefix 0x0A): 592 592 593 -0x0A aa ~/~/ Same as AT+MOD=aa 598 +(% class="box infomessage" %) 599 +((( 600 +**0x0A aa ~/~/ Same as AT+MOD=aa** 601 +))) 594 594 603 +==== 3.4.2.3 Poll an uplink ==== 595 595 596 - 597 -==== Poll an uplink ==== 598 - 599 599 * AT Command: 600 600 601 601 There is no AT Command to poll uplink 602 602 603 - 604 604 * Downlink Payload (prefix 0x08): 605 605 606 -0x08 FF ~/~/ Poll an uplink, 611 +(% class="box infomessage" %) 612 +((( 613 +**0x08 FF ~/~/ Poll an uplink,** 614 +))) 607 607 608 -Example: 0x08FF, ask device to send an Uplink 616 +**Example**: 0x08FF, ask device to send an Uplink 609 609 618 +==== 3.4.2.4 Enable Trigger Mode ==== 610 610 611 - ====Enable====620 +Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] 612 612 613 -Use of trigger mode, please check [[ADDMOD6>>path:#MOD6]] 614 - 615 615 * AT Command: 616 616 617 -AT+ADDMOD6=1 or 0 624 +(% class="box infomessage" %) 625 +((( 626 +**AT+ADDMOD6=1 or 0** 627 +))) 618 618 619 619 1: Enable Trigger Mode 620 620 621 621 0: Disable Trigger Mode 622 622 623 - 624 624 * Downlink Payload (prefix 0x0A 06): 625 625 626 -0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa, 635 +(% class="box infomessage" %) 636 +((( 637 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 638 +))) 627 627 640 +==== 3.4.2.5 Poll trigger settings ==== 628 628 629 -==== Poll trigger settings ==== 630 - 631 631 Poll trigger settings, 632 632 633 633 * AT Command: ... ... @@ -634,339 +634,337 @@ 634 634 635 635 There is no AT Command for this feature. 636 636 637 - 638 638 * Downlink Payload (prefix 0x AB 06): 639 639 640 -0xAB 06 ~/~/ Poll trigger settings, device will uplink [[trigger settings>>path:#Trigger_Settings]] once receive this command 650 +(% class="box infomessage" %) 651 +((( 652 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 653 +))) 641 641 655 +==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 642 642 643 -==== Enable / Disable DI1/DI2/DI3 as trigger ==== 644 - 645 645 Enable Disable DI1/DI2/DI2 as trigger, 646 646 647 647 * AT Command: 648 648 649 -Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 661 +(% class="box infomessage" %) 662 +((( 663 +**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 664 +))) 650 650 651 -Example: 666 +**Example:** 652 652 653 653 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 654 654 655 - 656 - 657 657 * Downlink Payload (prefix 0xAA 02): 658 658 659 -0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb 672 +(% class="box infomessage" %) 673 +((( 674 +**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 675 +))) 660 660 677 +==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 661 661 662 - 663 -==== Trigger1 – Set DI1 or DI3 as trigger ==== 664 - 665 665 Set DI1 or DI3(for LT-33222-L) trigger. 666 666 667 667 * AT Command: 668 668 669 -AT+TRIG1=a,b 683 +(% class="box infomessage" %) 684 +((( 685 +**AT+TRIG1=a,b** 686 +))) 670 670 671 671 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 672 672 673 673 b : delay timing. 674 674 675 -Example: 692 +**Example:** 676 676 677 677 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 678 678 679 - 680 680 * Downlink Payload (prefix 0x09 01 ): 681 681 682 -0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc) 698 +(% class="box infomessage" %) 699 +((( 700 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 701 +))) 683 683 703 +==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 684 684 685 -==== Trigger2 – Set DI2 as trigger ==== 686 - 687 687 Set DI2 trigger. 688 688 689 689 * AT Command: 690 690 691 -AT+TRIG2=a,b 709 +(% class="box infomessage" %) 710 +((( 711 +**AT+TRIG2=a,b** 712 +))) 692 692 693 693 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 694 694 695 695 b : delay timing. 696 696 697 -Example: 718 +**Example:** 698 698 699 699 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 700 700 701 - 702 702 * Downlink Payload (prefix 0x09 02 ): 703 703 704 -0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc) 724 +(% class="box infomessage" %) 725 +((( 726 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 727 +))) 705 705 729 +==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 706 706 707 - ====Trigger–SetAC(current)astrigger====731 +Set current trigger , base on AC port. See [[trigger mode>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] 708 708 709 -Set current trigger , base on AC port. See [[trigger mode>>path:#MOD6]] 710 - 711 711 * AT Command: 712 712 713 -AT+ACLIM. See [[trigger mode>>path:#MOD6]] 735 +(% class="box infomessage" %) 736 +((( 737 +**AT+ACLIM. ** 738 +))) 714 714 715 - 716 716 * Downlink Payload (prefix 0xAA 01 ): 717 717 718 -0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>path:#MOD6]] 742 +(% class="box infomessage" %) 743 +((( 744 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]** 745 +))) 719 719 747 +==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 720 720 721 - ====Trigger–SetAV(voltage)astrigger====749 +Set current trigger , base on AV port. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] 722 722 723 -Set current trigger , base on AV port. See [[trigger mode>>path:#MOD6]] 724 - 725 725 * AT Command: 726 726 727 -AT+AVLIM. See [[trigger mode>>path:#MOD6]] 753 +(% class="box infomessage" %) 754 +((( 755 +**AT+AVLIM. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]** 756 +))) 728 728 729 - 730 730 * Downlink Payload (prefix 0xAA 00 ): 731 731 732 -0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>path:#MOD6]] 760 +(% class="box infomessage" %) 761 +((( 762 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] ** 763 +))) 733 733 734 -==== Trigger – Set minimum interval ==== 765 +==== 3.4.2.11 Trigger – Set minimum interval ==== 735 735 736 736 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 737 737 738 738 * AT Command: 739 739 740 -AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger. 771 +(% class="box infomessage" %) 772 +((( 773 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 774 +))) 741 741 742 - 743 743 * Downlink Payload (prefix 0xAC ): 744 744 745 -0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 778 +(% class="box infomessage" %) 779 +((( 780 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 781 +))) 746 746 783 +==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 747 747 748 -==== DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 749 - 750 750 * AT Command: 751 751 752 752 There is no AT Command to control Digital Output 753 753 754 - 755 755 * Downlink Payload (prefix 0x02): 756 756 757 -0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output 791 +(% class="box infomessage" %) 792 +((( 793 +**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 794 +))) 758 758 796 +((( 759 759 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 798 +))) 760 760 800 +((( 761 761 01: Low, 00: High , 11: No action 802 +))) 762 762 763 -(% border="1" style="background-color:#f7faff" %) 764 -|Downlink Code|DO1|DO2|DO3 765 -|02 01 00 11|Low|High|No Action 766 -|02 00 11 01|High|No Action|Low 767 -|02 11 01 00|No Action|Low|High 804 +[[image:image-20220524092754-5.png]] 768 768 769 -Note: For LT-22222-L, there is no DO3, the last byte can use any value. 806 +((( 807 +(% style="color:red" %)Note: For LT-22222-L, there is no DO3, the last byte can use any value. 808 +))) 770 770 771 -Device will upload a packet if downlink code executes successfully. 810 +((( 811 +(% style="color:red" %)Device will upload a packet if downlink code executes successfully. 812 +))) 772 772 773 773 815 +==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 774 774 775 - 776 - 777 -==== DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 778 - 779 779 * AT Command: 780 780 781 781 There is no AT Command to control Digital Output 782 782 783 - 784 784 * Downlink Payload (prefix 0xA9): 785 785 786 -0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control 823 +(% class="box infomessage" %) 824 +((( 825 +**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 826 +))) 787 787 788 788 This is to control the digital output time of DO pin. Include four bytes: 789 789 790 -**First Byte:** Type code (0xA9) 830 +(% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) 791 791 792 -**Second Byte**: Inverter Mode 832 +(% style="color:#4f81bd" %)**Second Byte**(%%): Inverter Mode 793 793 794 794 01: DO pins will change back to original state after timeout. 795 795 796 796 00: DO pins will change to an inverter state after timeout 797 797 838 +(% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status: 798 798 799 - **Third Byte**:Control Methodand Ports status:840 +[[image:image-20220524093238-6.png]] 800 800 801 -(% border="1" style="background-color:#f7faff" %) 802 -|Second Byte|Status 803 -|0x01|DO1 set to low 804 -|0x00|DO1 set to high 805 -|0x11|DO1 NO Action 842 +(% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status: 806 806 807 - **Fourth Byte**:Control Methodand Ports status:844 +[[image:image-20220524093328-7.png]] 808 808 809 -(% border="1" style="background-color:#f7faff" %) 810 -|Second Byte|Status 811 -|0x01|DO2 set to low 812 -|0x00|DO2 set to high 813 -|0x11|DO2 NO Action 846 +(% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status: 814 814 815 - **Fifth Byte**:Control Methodand Ports status:848 +[[image:image-20220524093351-8.png]] 816 816 817 -(% border="1" style="background-color:#f7faff" %) 818 -|Second Byte|Status 819 -|0x01|DO3 set to low 820 -|0x00|DO3 set to high 821 -|0x11|DO3 NO Action 850 +(% style="color:#4f81bd" %)**Sixth and Seventh Byte**: 822 822 823 -**Sixth and Seventh Byte**: 824 - 825 825 Latching time. Unit: ms 826 826 827 827 Device will upload a packet if downlink code executes successfully. 828 828 856 +**Example payload:** 829 829 858 +**~1. A9 01 01 01 01 07 D0** 830 830 831 -Example payload: 832 - 833 -1. A9 01 01 01 01 07 D0 834 - 835 835 DO1 pin & DO2 pin & DO3 pin will be set to Low, last 2 seconds, then change back to original state. 836 836 862 +**2. A9 01 00 01 11 07 D0** 837 837 838 -1. A9 01 00 01 11 07 D0 839 - 840 840 DO1 pin set high, DO2 pin set low, DO3 pin no action, last 2 seconds, then change back to original state. 841 841 866 +**3. A9 00 00 00 00 07 D0** 842 842 843 -1. A9 00 00 00 00 07 D0 844 - 845 845 DO1 pin & DO2 pin & DO3 pin will be set to high, last 2 seconds, then both change to low. 846 846 870 +**4. A9 00 11 01 00 07 D0** 847 847 848 -1. A9 00 11 01 00 07 D0 849 - 850 850 DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low 851 851 852 852 875 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 853 853 854 - 855 -==== Relay ~-~- Control Relay Output RO1/RO2 ==== 856 - 857 857 * AT Command: 858 858 859 859 There is no AT Command to control Relay Output 860 860 861 - 862 862 * Downlink Payload (prefix 0x03): 863 863 864 -0x03 aa bb ~/~/ Set RO1/RO2 output 883 +(% class="box infomessage" %) 884 +((( 885 +**0x03 aa bb ~/~/ Set RO1/RO2 output** 886 +))) 865 865 888 +((( 866 866 If payload = 0x030100, it means set RO1 to close and RO2 to open. 890 +))) 867 867 892 +((( 868 868 01: Close , 00: Open , 11: No action 894 +))) 869 869 870 -(% border="1" style="background-color:#f7faff" %) 871 -|Downlink Code|RO1|RO2 872 -|03 00 11|Open|No Action 873 -|03 01 11|Close|No Action 874 -|03 11 00|No Action|Open 875 -|03 11 01|No Action|Close 876 -|03 00 00|Open|Open 877 -|03 01 01|Close|Close 878 -|03 01 00|Close|Open 879 -|03 00 01|Open|Close 896 +((( 897 +[[image:image-20220524093724-9.png]] 898 +))) 880 880 881 881 Device will upload a packet if downlink code executes successfully. 882 882 883 883 884 -==== Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 903 +==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 885 885 886 886 * AT Command: 887 887 888 888 There is no AT Command to control Relay Output 889 889 890 - 891 891 * Downlink Payload (prefix 0x05): 892 892 893 -0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control: 911 +(% class="box infomessage" %) 912 +((( 913 +**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 914 +))) 894 894 895 895 This is to control the relay output time of relay. Include four bytes: 896 896 897 -**First Byte:** Type code (0x05) 918 +(% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) 898 898 899 -**Second Byte(aa)**: Inverter Mode 920 +(% style="color:#4f81bd" %)**Second Byte(aa)**(%%): Inverter Mode 900 900 901 901 01: Relays will change back to original state after timeout. 902 902 903 903 00: Relays will change to an inverter state after timeout 904 904 926 +(% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 905 905 906 - **Third Byte(bb)**:Control Methodand Ports status:928 +[[image:image-20220524093831-10.png]] 907 907 908 -(% border="1" style="background-color:#f7faff" %) 909 -|Value|Status 910 -|0x11|RO1 and RO2 to NO 911 -|0x10|RO2 to NO, RO1 to NC 912 -|0x01|RO2 to NC, RO1 to NO 913 -|0x00|RO1 and RO2 to NC. 914 -|0x20|RO1 No Action, RO2 to NC 915 -|0x21|RO1 No Action, RO2 to NO 916 -|0x02|RO1 to NC, RO2 No Action 917 -|0x12|RO1 to NO, RO2 No Action 930 +(% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms 918 918 919 -**Fourth / Fifth Bytes (cc)**: Latching time. Unit: ms 920 - 921 921 Device will upload a packet if downlink code executes successfully. 922 922 923 - 924 - 925 925 **Example payload:** 926 926 927 -1. 05 01 11 07 D0 936 +**~1. 05 01 11 07 D0** 928 928 929 929 Relay1 and Relay 2 will be set to NO , last 2 seconds, then change back to original state. 930 930 940 +**2. 05 01 10 07 D0** 931 931 932 -1. 05 01 10 07 D0 933 - 934 934 Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then both change back to original state. 935 935 944 +**3. 05 00 01 07 D0** 936 936 937 -1. 05 00 01 07 D0 938 - 939 939 Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then relay change to NO, Relay2 change to NC. 940 940 948 +**4. 05 00 00 07 D0** 941 941 942 -1. 05 00 00 07 D0 943 - 944 944 Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO. 945 945 946 946 953 +==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 947 947 955 +When voltage exceed the threshold, count. Feature see [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]] 948 948 949 - 950 - 951 -==== Counting ~-~- Voltage threshold counting ==== 952 - 953 -When voltage exceed the threshold, count. Feature see [[MOD4>>path:#MOD4]] 954 - 955 955 * AT Command: 956 956 957 -AT+VOLMAX ~/~/ See [[MOD4>>path:#MOD4]] 959 +(% class="box infomessage" %) 960 +((( 961 +**AT+VOLMAX ~/~/ See [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]** 962 +))) 958 958 959 - 960 960 * Downlink Payload (prefix 0xA5): 961 961 962 -0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc 966 +(% class="box infomessage" %) 967 +((( 968 +**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 969 +))) 963 963 971 +==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 964 964 965 -==== Counting ~-~- Pre-configure the Count Number ==== 966 - 967 967 * AT Command: 968 968 969 -AT+SETCNT=aa,(bb cc dd ee) 975 +(% class="box infomessage" %) 976 +((( 977 +**AT+SETCNT=aa,(bb cc dd ee) ** 978 +))) 970 970 971 971 aa: 1: Set count1, 972 972 ... ... @@ -976,41 +976,46 @@ 976 976 977 977 Bb cc dd ee: number to be set 978 978 979 - 980 980 * Downlink Payload (prefix 0xA8): 981 981 982 -0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 990 +(% class="box infomessage" %) 991 +((( 992 +**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 993 +))) 983 983 995 +==== 3.4.2.18 Counting ~-~- Clear Counting ==== 984 984 985 - 986 - 987 - 988 -==== Counting ~-~- Clear Counting ==== 989 - 990 990 Clear counting for counting mode 991 991 992 992 * AT Command: 993 993 994 -AT+CLRCOUNT ~/~/ clear all counting 1001 +(% class="box infomessage" %) 1002 +((( 1003 +**AT+CLRCOUNT ~/~/ clear all counting** 1004 +))) 995 995 996 - 997 997 * Downlink Payload (prefix 0xA6): 998 998 999 -0x A6 01 ~/~/ clear all counting, 1008 +(% class="box infomessage" %) 1009 +((( 1010 +**0x A6 01 ~/~/ clear all counting,** 1011 +))) 1000 1000 1013 +==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1001 1001 1002 - 1003 - 1004 -==== Counting ~-~- Change counting mode save time ==== 1005 - 1006 1006 * AT Command: 1007 1007 1008 -AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1017 +(% class="box infomessage" %) 1018 +((( 1019 +**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1020 +))) 1009 1009 1010 - 1011 1011 * Downlink Payload (prefix 0xA7): 1012 1012 1013 -0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc, 1024 +(% class="box infomessage" %) 1025 +((( 1026 +**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1027 +))) 1014 1014 1015 1015 range: aa bb cc:0 to 16777215, (unit:second) 1016 1016
- 1653356737703-362.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.1 KB - Content
- image-20220524092754-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.8 KB - Content
- image-20220524093238-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +6.0 KB - Content
- image-20220524093328-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +6.1 KB - Content
- image-20220524093351-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +6.2 KB - Content
- image-20220524093724-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.3 KB - Content
- image-20220524093831-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.2 KB - Content
- image-20220524094641-11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +136.2 KB - Content