Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -558,75 +558,89 @@ 558 558 559 559 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>http://8.211.40.43:8080/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 560 560 561 -=== Sensor related commands === 561 +=== 3.4.2 Sensor related commands === 562 562 563 +==== 3.4.2.1 Set Transmit Interval ==== 563 563 564 -==== Set Transmit Interval ==== 565 - 566 566 Set device uplink interval. 567 567 568 568 * AT Command: 569 569 570 -AT+TDC=N 569 +(% class="box infomessage" %) 570 +((( 571 +**AT+TDC=N ** 572 +))) 571 571 572 -Example: AT+TDC=30000. Means set interval to 30 seconds 574 +**Example: **AT+TDC=30000. Means set interval to 30 seconds 573 573 574 - 575 575 * Downlink Payload (prefix 0x01): 576 576 577 -0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc) 578 +(% class="box infomessage" %) 579 +((( 580 +**0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 581 +))) 578 578 579 579 580 -==== Set Work Mode (AT+MOD) ==== 584 +==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 581 581 582 582 Set work mode. 583 583 584 584 * AT Command: 585 585 586 -AT+MOD=N 590 +(% class="box infomessage" %) 591 +((( 592 +**AT+MOD=N ** 593 +))) 587 587 588 -Example: AT+MOD=2. Set work mode to Double DI counting mode 595 +**Example**: AT+MOD=2. Set work mode to Double DI counting mode 589 589 590 - 591 591 * Downlink Payload (prefix 0x0A): 592 592 593 -0x0A aa ~/~/ Same as AT+MOD=aa 599 +(% class="box infomessage" %) 600 +((( 601 +**0x0A aa ~/~/ Same as AT+MOD=aa** 602 +))) 594 594 604 +==== 3.4.2.3 Poll an uplink ==== 595 595 596 - 597 -==== Poll an uplink ==== 598 - 599 599 * AT Command: 600 600 601 601 There is no AT Command to poll uplink 602 602 603 - 604 604 * Downlink Payload (prefix 0x08): 605 605 606 -0x08 FF ~/~/ Poll an uplink, 612 +(% class="box infomessage" %) 613 +((( 614 +**0x08 FF ~/~/ Poll an uplink,** 615 +))) 607 607 608 -Example: 0x08FF, ask device to send an Uplink 617 +**Example**: 0x08FF, ask device to send an Uplink 609 609 610 610 611 -==== Enable Trigger Mode ==== 620 +==== 3.4.2.4 Enable Trigger Mode ==== 612 612 613 -Use of trigger mode, please check [[ADDMOD6>>path:#MOD6]] 622 +Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] 614 614 615 615 * AT Command: 616 616 617 -AT+ADDMOD6=1 or 0 626 +(% class="box infomessage" %) 627 +((( 628 +**AT+ADDMOD6=1 or 0** 629 +))) 618 618 619 619 1: Enable Trigger Mode 620 620 621 621 0: Disable Trigger Mode 622 622 623 - 624 624 * Downlink Payload (prefix 0x0A 06): 625 625 626 -0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa, 637 +(% class="box infomessage" %) 638 +((( 639 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 640 +))) 627 627 628 628 629 -==== Poll trigger settings ==== 643 +==== 3.4.2.5 Poll trigger settings ==== 630 630 631 631 Poll trigger settings, 632 632 ... ... @@ -634,10 +634,12 @@ 634 634 635 635 There is no AT Command for this feature. 636 636 637 - 638 638 * Downlink Payload (prefix 0x AB 06): 639 639 640 -0xAB 06 ~/~/ Poll trigger settings, device will uplink [[trigger settings>>path:#Trigger_Settings]] once receive this command 653 +(% class="box infomessage" %) 654 +((( 655 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 656 +))) 641 641 642 642 643 643 ==== Enable / Disable DI1/DI2/DI3 as trigger ====