... ... @@ -558,63 +558,75 @@
558 558  
559 559  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>http://8.211.40.43:8080/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
560 560  
561 -=== Sensor related commands ===
561 +=== 3.4.2 Sensor related commands ===
562 562  
563 +==== 3.4.2.1 Set Transmit Interval ====
563 563  
564 -==== Set Transmit Interval ====
565 -
566 566  Set device uplink interval.
567 567  
568 568  * AT Command:
569 569  
570 -AT+TDC=N
569 +(% class="box infomessage" %)
570 +(((
571 +**AT+TDC=N **
572 +)))
571 571  
572 -Example: AT+TDC=30000. Means set interval to 30 seconds
574 +**Example: **AT+TDC=30000. Means set interval to 30 seconds
573 573  
574 -
575 575  * Downlink Payload (prefix 0x01):
576 576  
577 -0x01 aa bb cc     ~/~/ Same as AT+TDC=0x(aa bb cc)
578 +(% class="box infomessage" %)
579 +(((
580 +**0x01 aa bb cc     ~/~/ Same as AT+TDC=0x(aa bb cc)**
581 +)))
578 578  
579 579  
580 -==== Set Work Mode (AT+MOD) ====
584 +==== 3.4.2.2 Set Work Mode (AT+MOD) ====
581 581  
582 582  Set work mode.
583 583  
584 584  * AT Command:
585 585  
586 -AT+MOD=N 
590 +(% class="box infomessage" %)
591 +(((
592 +**AT+MOD=N  **
593 +)))
587 587  
588 -Example: AT+MOD=2. Set work mode to Double DI counting mode
595 +**Example**: AT+MOD=2. Set work mode to Double DI counting mode
589 589  
590 -
591 591  * Downlink Payload (prefix 0x0A):
592 592  
593 -0x0A aa     ~/~/ Same as AT+MOD=aa
599 +(% class="box infomessage" %)
600 +(((
601 +**0x0A aa     ~/~/ Same as AT+MOD=aa**
602 +)))
594 594  
604 +==== 3.4.2.3 Poll an uplink ====
595 595  
596 -
597 -==== Poll an uplink ====
598 -
599 599  * AT Command:
600 600  
601 601  There is no AT Command to poll uplink
602 602  
603 -
604 604  * Downlink Payload (prefix 0x08):
605 605  
606 -0x08 FF     ~/~/ Poll an uplink,
612 +(% class="box infomessage" %)
613 +(((
614 +**0x08 FF     ~/~/ Poll an uplink,**
615 +)))
607 607  
608 -Example: 0x08FF, ask device to send an Uplink
617 +**Example**: 0x08FF, ask device to send an Uplink
609 609  
610 610  
611 -==== Enable Trigger Mode ====
620 +==== 3.4.2.4 Enable Trigger Mode ====
612 612  
613 -Use of trigger mode, please check [[ADDMOD6>>path:#MOD6]]
622 +Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
614 614  
615 615  * AT Command:
616 616  
617 -AT+ADDMOD6=1 or 0
626 +(% class="box infomessage" %)
627 +(((
628 +**AT+ADDMOD6=1 or 0**
629 +)))
618 618  
619 619  1: Enable Trigger Mode
620 620  