Summary

Details

Page properties
Content
... ... @@ -1745,10 +1745,10 @@
1745 1745  )))
1746 1746  |(% style="width:141px" %)**Example**|(% style="width:357px" %)A6 **01**
1747 1747  
1748 -==== 3.4.2.19 Set the save intervals of the counting results, RO (Relay Output), and DO (Digital Output) states ====
1748 +==== 3.4.2.19 Counting ~-~- Set Saving Interval for 'Counting Result' ====
1749 1749  
1750 +
1750 1750  This command configures the device to periodically save the counting results, RO (Relay Output), and DO (Digital Output) states to internal flash memory at a user-defined interval. By setting a save interval, the device ensures that critical data (counting values and output states) is preserved in case of power loss.
1751 -The save interval can be adjusted to the user's needs, with a minimum value of (% style="color:blue" %)**30**(%%) seconds.
1752 1752  The saved RO/DO states can be restored after a device reset by combining this function with the (% style="color:blue" %)**AT+RODORESET**(%%) command.
1753 1753  
1754 1754  (% style="color:#037691" %)**AT Command**
... ... @@ -1760,7 +1760,7 @@
1760 1760  |(% style="width:124px" %)**Example**|(% style="width:374px" %)(((
1761 1761  AT+COUTIME=60
1762 1762  
1763 -Sets the device to save its counting results, RO and DO states to the memory every 60 seconds.
1763 +Sets the device to save its counting results to the memory every 60 seconds.
1764 1764  )))
1765 1765  
1766 1766  (% style="color:#037691" %)**Downlink Payload**
... ... @@ -1775,7 +1775,7 @@
1775 1775  |(% style="width:123px" %)**Example**|(% style="width:375px" %)(((
1776 1776  A7 **00 00 3C**
1777 1777  
1778 -SSets the device to save its counting results, RO and DO states to the memory every 60 seconds.
1778 +Sets the device to save its counting results to the memory every 60 seconds.
1779 1779  )))
1780 1780  
1781 1781  ==== 3.4.2.20 Reset saved RO and DO states ====
... ... @@ -2889,7 +2889,7 @@
2889 2889  = 9. Package information =
2890 2890  
2891 2891  
2892 -(% style="color:#037691" %)**Package Includes**:
2892 +**Package includes**:
2893 2893  
2894 2894  * 1 x LT-22222-L I/O Controller
2895 2895  * 1 x LoRa antenna matched to the frequency of the LT-22222-L
... ... @@ -2896,10 +2896,12 @@
2896 2896  * 1 x bracket for DIN rail mounting
2897 2897  * 1 x 3.5 mm programming cable
2898 2898  
2899 -(% style="color:#037691" %)**Dimension and weight**:
2899 +**Dimension and weight**:
2900 2900  
2901 -* Package Size / pcs : 145×80×50 mm
2902 -* Weight / pcs : 180 g
2901 +* Device Size: 13.5 x 7 x 3 cm
2902 +* Device Weight: 105 g
2903 +* Package Size / pcs : 14.5 x 8 x 5 cm
2904 +* Weight / pcs : 170 g
2903 2903  
2904 2904  = 10. Support =
2905 2905