Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,13 +4,8 @@ 4 4 **LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 -**Table of Contents:** 8 8 9 -{{toc/}} 10 10 11 - 12 - 13 - 14 14 = 1.Introduction = 15 15 16 16 == 1.1 What is LT Series I/O Controller == ... ... @@ -251,7 +251,7 @@ 251 251 252 252 (% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L. 253 253 254 - **To use counting mode, please run:**249 +To use counting mode, please run: 255 255 256 256 (% class="box infomessage" %) 257 257 ((( ... ... @@ -315,152 +315,181 @@ 315 315 316 316 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 317 317 318 -**To use counting mode, please run:** 319 319 320 -(% class="box infomessage" %) 321 -((( 322 -**AT+MOD=3** 323 -))) 314 +To use counting mode, please run: 324 324 325 -(% class="box infomessage" %) 326 -((( 327 -**ATZ** 328 -))) 316 +AT+MOD=3 329 329 318 +ATZ 319 + 320 + 330 330 Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:#COUNT_COMMAND]]. 331 331 332 -=== 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 333 333 324 + 325 + 326 +1. 327 +11. 328 +111. AT+MOD=4, Single DI Counting + 1 x Voltage Counting 329 + 330 +**LT33222-L**: This mode the DI3 is used as a counting pin. 331 + 334 334 **LT22222-L**: This mode the DI1 is used as a counting pin. 335 335 334 + 336 336 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. 337 337 338 -[[image:image-20220523181903-8.png]] 339 339 340 -((( 341 -(% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 342 -))) 338 +(% border="1" style="background-color:#f7faff" %) 339 +|Size(bytes)|4|4|1|1|1 340 +|Value|COUNT1|AVI1 Counting|DIDORO*|((( 341 +Reserve 343 343 344 -[[image:image-20220523181727-7.png]] 343 + 344 +)))|MOD 345 345 346 +**DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 347 + 348 +(% border="1" style="background-color:#f7faff" %) 349 +|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 350 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 351 + 346 346 * RO is for relay. ROx=1 : close,ROx=0 always open. 347 347 * FIRST: Indicate this is the first packet after join network. 348 348 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 349 349 350 - (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.356 +Note: DO3 is not valid for LT-22222-L. 351 351 352 -**To use this mode, please run:** 353 353 354 -(% class="box infomessage" %) 355 -((( 356 -**AT+MOD=4** 357 -))) 359 +To use this mode, please run: 358 358 359 -(% class="box infomessage" %) 360 -((( 361 -**ATZ** 362 -))) 361 +AT+MOD=4 363 363 363 +ATZ 364 364 365 + 366 + 365 365 Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:#COUNT_COMMAND]]. 366 366 367 - **Plus below command for AVI1 Counting:**369 +Plus below command for AVI1 Counting: 368 368 369 -(% class="box infomessage" %) 370 -((( 371 -**AT+SETCNT=3,60 (set AVI Count to 60)** 372 -))) 371 +AT+SETCNT=3,60 (set AVI Count to 60) 373 373 374 -(% class="box infomessage" %) 375 -((( 376 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 377 -))) 373 +AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1) 378 378 379 -(% class="box infomessage" %) 380 -((( 381 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 382 -))) 375 +AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1) 383 383 384 -(% class="box infomessage" %) 385 -((( 386 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 387 -))) 377 +AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1) 388 388 389 -=== 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 390 390 380 + 381 +1. 382 +11. 383 +111. AT+MOD=5, Single DI Counting + 2 x AVI + 1 x ACI 384 + 385 +**LT33222-L**: This mode the DI3 is used as a counting pin. 386 + 391 391 **LT22222-L**: This mode the DI1 is used as a counting pin. 392 392 393 -[[image:image-20220523182334-9.png]] 394 394 395 -((( 396 -(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 397 -))) 390 +(% border="1" style="background-color:#f7faff" %) 391 +|Size(bytes)|2|2|2|2|1|1|1 392 +|Value|((( 393 +AVI1 398 398 395 +voltage 396 +)))|((( 397 +AVI2 398 + 399 +voltage 400 +)))|((( 401 +ACI1 402 + 403 +Current 404 +)))|COUNT1|DIDORO*|((( 405 +Reserve 406 + 407 + 408 +)))|MOD 409 + 410 +**DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 411 + 412 +(% border="1" style="background-color:#f7faff" %) 413 +|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 414 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 415 + 399 399 * RO is for relay. ROx=1 : close,ROx=0 always open. 400 400 * FIRST: Indicate this is the first packet after join network. 401 401 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 402 402 403 - (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.420 +Note: DO3 is not valid for LT-22222-L. 404 404 405 -**To use this mode, please run:** 406 406 407 -(% class="box infomessage" %) 408 -((( 409 -**AT+MOD=5** 410 -))) 423 +To use this mode, please run: 411 411 412 -(% class="box infomessage" %) 413 -((( 414 -**ATZ** 415 -))) 425 +AT+MOD=5 416 416 427 +ATZ 428 + 429 + 417 417 Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:#COUNT_COMMAND]]. 418 418 419 -=== 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 420 420 421 -(% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** 422 422 434 + 435 + 436 +1. 437 +11. 438 +111. AT+ADDMOD=6. (Trigger Mode, Optional) 439 + 440 +**This mode is an optional mode for trigger purpose. It can run together with other mode.** 441 + 423 423 For example, if user has configured below commands: 424 424 425 -* **AT+MOD=1****~-~->**The normal working mode426 -* **AT+ADDMOD6=1****~-~->**Enable trigger444 +* AT+MOD=1 à The normal working mode 445 +* AT+ADDMOD6=1 à Enable trigger 427 427 428 428 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 429 429 430 -1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%)data type431 -1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**449 +1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN **unconfirmed** data type 450 +1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN **CONFIRMED data type.** 432 432 433 433 **AT Command to set Trigger Condition**: 434 434 435 - (% style="color:#4f81bd" %)**Trigger base on voltage**:454 +**Trigger base on voltage**: 436 436 437 437 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> 438 438 439 - **Example:**458 +Example: 440 440 441 441 AT+AVLIM=3000,6000,0,2000 (If AVI1 voltage lower than 3v or higher than 6v. or AV2 voltage is higher than 2v, LT will trigger Uplink) 442 442 443 443 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 444 444 445 -(% style="color:#4f81bd" %)**Trigger base on current**: 446 446 465 +**Trigger base on current**: 466 + 447 447 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> 448 448 449 - **Example:**469 +Example: 450 450 451 451 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 452 452 453 -(% style="color:#4f81bd" %)**Trigger base on DI status**: 454 454 474 +**Trigger base on DI status**: 475 + 455 455 DI status trigger Flag. 456 456 457 457 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 458 458 459 - **Example:**480 +Example: 460 460 461 461 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 462 462 463 463 485 + 486 + 487 + 464 464 **Downlink Command to set Trigger Condition** 465 465 466 466 Type Code: 0xAA. Downlink command same as AT Command [[AT+AVLIM, AT+ACLIM>>path:#AT_Trigger]] ... ... @@ -479,8 +479,9 @@ 479 479 480 480 Yy4 yy4: AC2 or AV2 high limit. 481 481 482 -**Example1**: AA 00 13 88 00 00 00 00 00 00 483 483 507 +Example1: AA 00 13 88 00 00 00 00 00 00 508 + 484 484 Same as AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 485 485 486 486 Example2: AA 02 01 00 ... ... @@ -487,14 +487,35 @@ 487 487 488 488 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 489 489 490 -(% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 491 491 516 + 517 + 518 +**Trigger Settings Payload Explanation:** 519 + 492 492 MOD6 Payload : total 11 bytes payload 493 493 494 -[[image:image-20220524085923-1.png]] 522 +(% border="1" style="background-color:#f7faff" %) 523 +|Size(bytes)|1|1|1|6|1|1 524 +|Value|((( 525 +TRI_A 495 495 496 -(% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 527 +FLAG 528 +)))|((( 529 +TRI_A 497 497 531 +Status 532 +)))|((( 533 +TRI_DI 534 + 535 +FLAG+STA 536 +)))|Reserve|Enable/Disable MOD6|((( 537 +MOD 538 + 539 +(6) 540 +))) 541 + 542 +**TRI FLAG1** is a combination to show if trigger is set for this part. Totally 1byte as below 543 + 498 498 (% border="1" style="background-color:#f7faff" %) 499 499 |bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 500 500 |((( ... ... @@ -538,7 +538,7 @@ 538 538 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW 539 539 540 540 541 - (% style="color:#4f81bd" %)**TRI Status1**(%%)is a combination to show which condition is trigger. Totally 1byte as below587 +**TRI Status1** is a combination to show which condition is trigger. Totally 1byte as below 542 542 543 543 (% border="1" style="background-color:#f7faff" %) 544 544 |bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 ... ... @@ -585,7 +585,7 @@ 585 585 586 586 587 587 588 - (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below634 +**TRI_DI FLAG+STA **is a combination to show which condition is trigger. Totally 1byte as below 589 589 590 590 (% border="1" style="background-color:#f7faff" %) 591 591 |bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 ... ... @@ -600,7 +600,7 @@ 600 600 00000101: Means both DI1 and DI2 trigger are enabled. 601 601 602 602 603 - (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable.649 +**Enable/Disable MOD6 **: 0x01: MOD6 is enable. 0x00: MOD6 is disable. 604 604 605 605 606 606 Downlink command to poll MOD6 status:
- image-20220523182334-9.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.4 KB - Content
- image-20220524085923-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.4 KB - Content
- image-20220524090106-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -5.2 KB - Content