Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
From version 249.1
edited by Mengting Qiu
on 2025/05/23 16:52
on 2025/05/23 16:52
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Xiaoling - Content
-
... ... @@ -1511,9 +1511,9 @@ 1511 1511 |(% style="width:113px" %)**Parameters**|(% style="width:384px" %)((( 1512 1512 **RO1_status** : 1 byte in hex 1513 1513 1514 -00: Open1514 +00: Close 1515 1515 1516 -01: Close1516 +01: Open 1517 1517 1518 1518 11: No action 1519 1519 ... ... @@ -1520,9 +1520,9 @@ 1520 1520 1521 1521 **RO2_status** : 1 byte in hex 1522 1522 1523 -00: Open1523 +00: Close 1524 1524 1525 -01: Close1525 +01: Open 1526 1526 1527 1527 11: No action 1528 1528 ))) ... ... @@ -1542,6 +1542,7 @@ 1542 1542 (% style="color:red" %)**The device will transmit an uplink packet if the downlink payload is executed successfully.** 1543 1543 ))) 1544 1544 1545 + 1545 1545 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1546 1546 1547 1547 ... ... @@ -1673,6 +1673,7 @@ 1673 1673 If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1 1674 1674 ))) 1675 1675 1677 + 1676 1676 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1677 1677 1678 1678 ... ... @@ -1723,6 +1723,7 @@ 1723 1723 Sets the COUNT1 to 10. 1724 1724 ))) 1725 1725 1728 + 1726 1726 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1727 1727 1728 1728 ... ... @@ -1745,12 +1745,11 @@ 1745 1745 ))) 1746 1746 |(% style="width:141px" %)**Example**|(% style="width:357px" %)A6 **01** 1747 1747 1748 -==== 3.4.2.19 Set the saveintervalsofthe countingresults,RO (Relay Output), and DO (Digital Output) states====1751 +==== 3.4.2.19 Counting ~-~- Set Saving Interval for 'Counting Result' ==== 1749 1749 1750 -This command configures the device to periodically save the counting results, RO (Relay Output), and DO (Digital Output) states to internal flash memory at a user-defined interval. By setting a save interval, the device ensures that critical data (counting values and output states) is preserved in case of power loss. 1751 -The save interval can be adjusted to the user's needs, with a minimum value of (% style="color:blue" %)**30**(%%) seconds. 1752 -The saved RO/DO states can be restored after a device reset by combining this function with the (% style="color:blue" %)**AT+RODORESET**(%%) command. 1753 1753 1754 +This command allows you to configure the device to save its counting result to internal flash memory at specified intervals. By setting a save time, the device will periodically store the counting data to prevent loss in case of power failure. The save interval can be adjusted to suit your requirements, with a minimum value of 30 seconds. 1755 + 1754 1754 (% style="color:#037691" %)**AT Command** 1755 1755 1756 1756 (% border="2" style="width:500px" %) ... ... @@ -1760,7 +1760,7 @@ 1760 1760 |(% style="width:124px" %)**Example**|(% style="width:374px" %)((( 1761 1761 AT+COUTIME=60 1762 1762 1763 -Sets the device to save its counting results ,RO and DO states to the memory every 60 seconds.1765 +Sets the device to save its counting results to the memory every 60 seconds. 1764 1764 ))) 1765 1765 1766 1766 (% style="color:#037691" %)**Downlink Payload** ... ... @@ -1775,7 +1775,7 @@ 1775 1775 |(% style="width:123px" %)**Example**|(% style="width:375px" %)((( 1776 1776 A7 **00 00 3C** 1777 1777 1778 -S Sets the device to save its counting results,RO and DO states to the memory every 60 seconds.1780 +Sets the device to save its counting results to the memory every 60 seconds. 1779 1779 ))) 1780 1780 1781 1781 ==== 3.4.2.20 Reset saved RO and DO states ====