Last modified by Mengting Qiu on 2025/06/04 18:42

From version 243.4
edited by Xiaoling
on 2025/03/20 15:31
Change comment: There is no comment for this version
To version 243.8
edited by Xiaoling
on 2025/03/20 15:49
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1286,7 +1286,7 @@
1286 1286  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
1287 1287  
1288 1288  
1289 -Sets the current trigger based on the AV port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1289 +Sets the current trigger based on the AV port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D628TriggerMode2COptional29"]]
1290 1290  
1291 1291  (% style="color:#037691" %)**AT Command**
1292 1292  
... ... @@ -1329,7 +1329,7 @@
1329 1329  
1330 1330  Triggers an uplink if AVI1 voltage is lower than 3V or higher than 6V, or if AV2 voltage is higher than 2V.
1331 1331  )))
1332 -|(% style="width:104px" %)**Note**|(% style="width:394px" %)See also, [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1332 +|(% style="width:104px" %)**Note**|(% style="width:394px" %)See also, [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D628TriggerMode2COptional29"]]
1333 1333  
1334 1334  ==== 3.4.2.11 Trigger – Set the minimum interval ====
1335 1335  
... ... @@ -1349,7 +1349,7 @@
1349 1349  
1350 1350  The device won't respond to the second trigger within 5 minutes after the first trigger.
1351 1351  )))
1352 -|(% style="width:113px" %)Note|(% style="width:385px" %)(% style="color:red" %)**The time must be greater than 5 minutes.**
1352 +|(% style="width:113px" %)**Note**|(% style="width:385px" %)(% style="color:red" %)**The time must be greater than 5 minutes.**
1353 1353  
1354 1354  (% style="color:#037691" %)**Downlink Payload**
1355 1355  
... ... @@ -1365,7 +1365,7 @@
1365 1365  
1366 1366  The device won't respond to the second trigger within 5 minutes after the first trigger.
1367 1367  )))
1368 -|(% style="width:112px" %)Note|(% style="width:386px" %)(% style="color:red" %)**The time must be greater than 5 minutes.**
1368 +|(% style="width:112px" %)**Note**|(% style="width:386px" %)(% style="color:red" %)**The time must be greater than 5 minutes.**
1369 1369  
1370 1370  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
1371 1371  
... ... @@ -1428,7 +1428,6 @@
1428 1428  
1429 1429  (% style="color:#037691" %)**Downlink payload**
1430 1430  
1431 -
1432 1432  (% border="2" style="width:500px" %)
1433 1433  |(% style="width:116px" %)**Prefix**|(% style="width:382px" %)0xA9
1434 1434  |(% style="width:116px" %)**Parameters**|(% style="width:382px" %)(((
... ... @@ -1543,6 +1543,7 @@
1543 1543  (% style="color:red" %)**The device will transmit an uplink packet if the downlink payload is executed successfully.**
1544 1544  )))
1545 1545  
1545 +
1546 1546  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1547 1547  
1548 1548  
... ... @@ -1674,8 +1674,10 @@
1674 1674  If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1
1675 1675  )))
1676 1676  
1677 +
1677 1677  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1678 1678  
1680 +
1679 1679  This command allows users to pre-configure specific count numbers for various counting parameters such as Count1, Count2, or AVI1 Count. Use the AT command to set the desired count number for each configuration.
1680 1680  
1681 1681  (% style="color:#037691" %)**AT Command**
... ... @@ -1723,8 +1723,10 @@
1723 1723  Sets the COUNT1 to 10.
1724 1724  )))
1725 1725  
1728 +
1726 1726  ==== 3.4.2.18 Counting ~-~- Clear Counting ====
1727 1727  
1731 +
1728 1728  This command clears the counting in counting mode.
1729 1729  
1730 1730  (% style="color:#037691" %)**AT Command**
... ... @@ -2001,7 +2001,6 @@
2001 2001  
2002 2002  (% style="color:blue" %)**26 01  ** (%%) ~/~/  The downlink payload 26 01 is used to query the device's firmware version, frequency band, subband, and TDC time.
2003 2003  
2004 -
2005 2005  
2006 2006  )))
2007 2007  
... ... @@ -2099,7 +2099,6 @@
2099 2099  
2100 2100  Your integration has been added to the** Integrations** list and will be displayed on the **Integrations** page. Check whether the status is shown as **Active**. If not, review your configuration settings and correct any errors.
2101 2101  
2102 -
2103 2103  [[image:thingseye.io_integrationsCenter_integrations.png]]
2104 2104  
2105 2105  
... ... @@ -2145,8 +2145,6 @@
2145 2145  
2146 2146  You can create a dashboard with ThingsEye to visualize the sensor data coming from the LT-22222-L. The following image shows a dashboard created for the LT-22222-L. See **Creating a dashboard** in ThingsEye documentation for more information.
2147 2147  
2148 -
2149 -
2150 2150  [[image:lt-22222-l-dashboard.png]]
2151 2151  
2152 2152  
... ... @@ -2352,7 +2352,7 @@
2352 2352  (((
2353 2353  The LT-22222-L has two relay interfaces, RO1 and RO2, each using two pins of the screw terminal (ROx-1 and ROx-2 where x is the port number, 1 or 2). You can connect a device's power line in series with one of the relay interfaces (e.g., RO1-1 and RO1-2 screw terminals). See the example below:
2354 2354  
2355 -**Note**: The ROx pins will be in the Open (NO) state when the LT-22222-L is powered off.
2355 +(% style="color:red" %)**Note:**(%%) The ROx pins will be in the Open (NO) state when the LT-22222-L is powered off.
2356 2356  )))
2357 2357  
2358 2358  [[image:image-20220524100215-9.png]]
... ... @@ -2411,7 +2411,6 @@
2411 2411  
2412 2412  )))
2413 2413  
2414 -
2415 2415  (((
2416 2416  On the PC, you need to set the (% style="color:#4f81bd" %)**serial tool **(%%)(such as [[PuTTY>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]] or [[SecureCRT>>https://www.vandyke.com/cgi-bin/releases.php?product=securecrt]]) to a baud rate of (% style="color:green" %)**9600**(%%) to access the serial console of LT-22222-L. Access to AT commands is disabled by default, and a password (default: (% style="color:green" %)**123456**)(%%) must be entered to enable AT command access, as shown below:
2417 2417  )))
... ... @@ -2420,9 +2420,6 @@
2420 2420  
2421 2421  
2422 2422  (((
2423 -You can find more details in the [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
2424 -
2425 -
2426 2426  == 4.2 LT-22222-L related AT commands ==
2427 2427  
2428 2428