Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.pradeeka - Content
-
... ... @@ -128,8 +128,8 @@ 128 128 (% style="text-align:center" %) 129 129 [[image:lt33222-l.jpg||height="110" width="95"]] 130 130 )))|(% style="width:256px" %)((( 131 -* 3x Digital Input (Bi-direction)132 -* 3x Digital Output131 +* 2 x Digital Input (Bi-direction) 132 +* 2 x Digital Output 133 133 * 2 x Relay Output (5A@250VAC / 30VDC) 134 134 * 2 x 0~~20mA Analog Input (res:0.01mA) 135 135 * 2 x 0~~30V Analog Input (res:0.01v) ... ... @@ -261,18 +261,12 @@ 261 261 ** Enter the **AppEUI** in the **JoinEUI** field and click the **Confirm** button. If The Things Stack accepts the JoinEUI you provided, it will display the message 'This end device can be registered on the network'. 262 262 ** In the **DevEUI** field, enter the **DevEUI**. 263 263 ** In the **AppKey** field, enter the **AppKey.** 264 -** In the **End device ID** field, enter a unique name for your LT-22222- Lwithin this application.264 +** In the **End device ID** field, enter a unique name for your LT-22222-N within this application. 265 265 ** Under **After registration**, select the **View registered end device** option. 266 -** Click **Register end device** button. 267 267 268 268 [[image:lt-22222-l-dev-repo-reg-p2.png]] 269 269 270 270 271 -* You will be navigated to the **Device overview** page. 272 - 273 -[[image:lt-22222-device-overview.png]] 274 - 275 - 276 276 ==== 3.2.1.2 Adding device manually ==== 277 277 278 278 ... ... @@ -374,8 +374,11 @@ 374 374 This is the default mode. 375 375 376 376 The uplink payload is 11 bytes long. 377 -(% style="display:none" wfd-invisible="true" %) 378 378 372 +(% style="color:red" %)**Note:The maximum count depends on the bytes number of bytes. 373 +The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 374 +It starts counting again when it reaches the maximum value.**(% style="display:none" wfd-invisible="true" %) 375 + 379 379 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 380 380 |(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** 381 381 |Value|((( ... ... @@ -644,7 +644,7 @@ 644 644 645 645 646 646 (% style="color:red" %)**Note:The maximum count depends on the bytes it is. 647 -The maximum count for four bytes is FFFF (hex) = 65 535(dec).644 +The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 648 648 It starts counting again when it reaches the maximum value.** 649 649 650 650 ... ... @@ -1160,7 +1160,7 @@ 1160 1160 Enable DI1 trigger, disable DI2 trigger 1161 1161 ))) 1162 1162 1163 -==== 3.4.2.7 Trigger1 – Set DI 1or DI3 as a trigger ====1160 +==== 3.4.2.7 Trigger1 – Set DI or DI3 as a trigger ==== 1164 1164 1165 1165 1166 1166 Sets DI1 or DI3 (for LT-33222-L) as a trigger. ... ... @@ -1534,7 +1534,7 @@ 1534 1534 |03 00 11|Open|No action 1535 1535 |03 01 11|Close|No action 1536 1536 |03 11 00|No action|Open 1537 -|03 11 01|No action|Close1534 +|03 11 10|No action|Close 1538 1538 |03 00 00|Open|Open 1539 1539 |03 01 01|Close|Close 1540 1540 |03 01 00|Close|Open ... ... @@ -2143,7 +2143,7 @@ 2143 2143 ==== 3.5.2.4 Viewing sensor data on a dashboard ==== 2144 2144 2145 2145 2146 -You can create a dashboard with ThingsEye to visualize the sensor data coming from the LT- 22222-L. The following image shows a dashboard created for the LT-22222-L. See **Creating a dashboard** in ThingsEye documentation for more information.2143 +You can create a dashboard with ThingsEye to visualize the sensor data coming from the LHT65N-VIB. The following image shows a dashboard created for the LT-22222-L. See **Creating a dashboard** in ThingsEye documentation for more information. 2147 2147 2148 2148 2149 2149 ... ... @@ -2595,7 +2595,8 @@ 2595 2595 2596 2596 **2. Verify that the LG01/02 gateway RX frequency matches the AT+CHS setting exactly.** 2597 2597 2598 -**3. Make sure the SF/bandwidth settings in the LG01/LG02 match the settings of AT+DR. Refer to [[this link>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 2595 +**3. Make sure the SF/bandwidth settings in the LG01/LG02 match the settings of AT+DR. Refer to [[this link>>url:http://www.dragino.com/downloads/index.php? 2596 +dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 2599 2599 2600 2600 **4. The commands AT+RX2FQ and AT+RX2DR enable downlink functionality. To set the correct parameters, you can check the actual downlink parameters to be used as shown below. Here, RX2FQ should be set to 868400000 and RX2DR should be set to 5.** 2601 2601 ))) ... ... @@ -2692,7 +2692,7 @@ 2692 2692 ))) 2693 2693 2694 2694 ((( 2695 -You can follow the introductions on [[how to upgrade the image>>||anchor="H 6.1Howtoupdatethefirmware3F"]]. When downloading, select the required image file.2693 +You can follow the introductions on [[how to upgrade the image>>||anchor="H5.1Howtoupgradetheimage3F"]]. When downloading, select the required image file. 2696 2696 ))) 2697 2697 2698 2698 ((( ... ... @@ -2872,7 +2872,7 @@ 2872 2872 2873 2873 2874 2874 The FCD count of the gateway is inconsistent with the FCD count of the node, causing the downlink to remain in the queue. 2875 -Use this command to synchronize their counts: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resett ingthedownlinkpacketcount"]]2873 +Use this command to synchronize their counts: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resetsthedownlinkpacketcount"]] 2876 2876 2877 2877 2878 2878 = 8. Ordering information =