Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,7 +21,6 @@ 21 21 22 22 == 1.1 What is the LT-22222-L I/O Controller? == 23 23 24 - 25 25 ((( 26 26 ((( 27 27 {{info}} ... ... @@ -100,7 +100,6 @@ 100 100 101 101 == 1.3 Features == 102 102 103 - 104 104 * LoRaWAN Class A & Class C modes 105 105 * Optional Customized LoRa Protocol 106 106 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 ... ... @@ -111,7 +111,6 @@ 111 111 112 112 == 1.4 Applications == 113 113 114 - 115 115 * Smart buildings & home automation 116 116 * Logistics and supply chain management 117 117 * Smart metering ... ... @@ -122,14 +122,14 @@ 122 122 == 1.5 Hardware Variants == 123 123 124 124 125 -(% border="1" cellspacing="3" style="width:510px" %) 122 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 126 126 |(% style="background-color:#4f81bd; color:white; width:94px" %)**Model**|(% style="background-color:#4f81bd; color:white; width:172px" %)**Photo**|(% style="background-color:#4f81bd; color:white; width:244px" %)**Description** 127 -|(% style="width:94px" %)**LT- 33222-L**|(% style="width:172px" %)(((124 +|(% style="width:94px" %)**LT-22222-L**|(% style="width:172px" %)((( 128 128 (% style="text-align:center" %) 129 -[[image:lt33222-l.jpg||height="11 0" width="95"]]126 +[[image:lt33222-l.jpg||height="116" width="100"]] 130 130 )))|(% style="width:256px" %)((( 131 -* 3x Digital Input (Bi-direction)132 -* 3x Digital Output128 +* 2 x Digital Input (Bi-direction) 129 +* 2 x Digital Output 133 133 * 2 x Relay Output (5A@250VAC / 30VDC) 134 134 * 2 x 0~~20mA Analog Input (res:0.01mA) 135 135 * 2 x 0~~30V Analog Input (res:0.01v) ... ... @@ -140,7 +140,6 @@ 140 140 141 141 == 2.1 Connecting the antenna == 142 142 143 - 144 144 Connect the LoRa antenna to the antenna connector, **ANT**,** **located on the top right side of the device, next to the upper screw terminal block. Secure the antenna by tightening it clockwise. 145 145 146 146 {{warning}} ... ... @@ -147,41 +147,38 @@ 147 147 **Warning! Do not power on the device without connecting the antenna.** 148 148 {{/warning}} 149 149 150 - 151 151 == 2.2 Terminals == 152 152 148 +The LT-22222-L has two screw terminal blocks. The upper screw treminal block has 6 screw terminals and the lower screw terminal block has 10 screw terminals. 153 153 154 -The LT-22222-L has two screw terminal blocks. The upper screw terminal block has 6 screw terminals and the lower screw terminal block has 10 screw terminals. 155 - 156 156 **Upper screw terminal block (from left to right):** 157 157 158 -(% border="1" cellspacing="3" style="background-color:#f2f2f2;width:381px" %)159 -|=(% style="width: 139px;background-color:#4f81bd;color:white" %)Screw Terminal|=(% style="width:242px;background-color:#4f81bd;color:white" %)Function160 -|(% style="width: 139px" %)GND|(% style="width:242px" %)Ground161 -|(% style="width: 139px" %)VIN|(% style="width:242px" %)Input Voltage162 -|(% style="width: 139px" %)AVI2|(% style="width:242px" %)Analog Voltage Input Terminal 2163 -|(% style="width: 139px" %)AVI1|(% style="width:242px" %)Analog Voltage Input Terminal 1164 -|(% style="width: 139px" %)ACI2|(% style="width:242px" %)Analog Current Input Terminal 2165 -|(% style="width: 139px" %)ACI1|(% style="width:242px" %)Analog Current Input Terminal 1152 +(% style="width:634px" %) 153 +|=(% style="width: 295px;" %)Screw Terminal|=(% style="width: 338px;" %)Function 154 +|(% style="width:295px" %)GND|(% style="width:338px" %)Ground 155 +|(% style="width:295px" %)VIN|(% style="width:338px" %)Input Voltage 156 +|(% style="width:295px" %)AVI2|(% style="width:338px" %)Analog Voltage Input Terminal 2 157 +|(% style="width:295px" %)AVI1|(% style="width:338px" %)Analog Voltage Input Terminal 1 158 +|(% style="width:295px" %)ACI2|(% style="width:338px" %)Analog Current Input Terminal 2 159 +|(% style="width:295px" %)ACI1|(% style="width:338px" %)Analog Current Input Terminal 1 166 166 167 167 **Lower screw terminal block (from left to right):** 168 168 169 -(% border="1" cellspacing="3" style="background-color:#f2f2f2;width:253px" %)170 -|=(% style="width: 125px;background-color:#4f81bd;color:white" %)Screw Terminal|=(% style="width:128px;background-color:#4f81bd;color:white" %)Function171 -|(% style="width: 125px" %)RO1-2|(% style="width:128px" %)Relay Output 1172 -|(% style="width: 125px" %)RO1-1|(% style="width:128px" %)Relay Output 1173 -|(% style="width: 125px" %)RO2-2|(% style="width:128px" %)Relay Output 2174 -|(% style="width: 125px" %)RO2-1|(% style="width:128px" %)Relay Output 2175 -|(% style="width: 125px" %)DI2+|(% style="width:128px" %)Digital Input 2176 -|(% style="width: 125px" %)DI2-|(% style="width:128px" %)Digital Input 2177 -|(% style="width: 125px" %)DI1+|(% style="width:128px" %)Digital Input 1178 -|(% style="width: 125px" %)DI1-|(% style="width:128px" %)Digital Input 1179 -|(% style="width: 125px" %)DO2|(% style="width:128px" %)Digital Output 2180 -|(% style="width: 125px" %)DO1|(% style="width:128px" %)Digital Output 1163 +(% style="width:633px" %) 164 +|=(% style="width: 296px;" %)Screw Terminal|=(% style="width: 334px;" %)Function 165 +|(% style="width:296px" %)RO1-2|(% style="width:334px" %)Relay Output 1 166 +|(% style="width:296px" %)RO1-1|(% style="width:334px" %)Relay Output 1 167 +|(% style="width:296px" %)RO2-2|(% style="width:334px" %)Relay Output 2 168 +|(% style="width:296px" %)RO2-1|(% style="width:334px" %)Relay Output 2 169 +|(% style="width:296px" %)DI2+|(% style="width:334px" %)Digital Input 2 170 +|(% style="width:296px" %)DI2-|(% style="width:334px" %)Digital Input 2 171 +|(% style="width:296px" %)DI1+|(% style="width:334px" %)Digital Input 1 172 +|(% style="width:296px" %)DI1-|(% style="width:334px" %)Digital Input 1 173 +|(% style="width:296px" %)DO2|(% style="width:334px" %)Digital Output 2 174 +|(% style="width:296px" %)DO1|(% style="width:334px" %)Digital Output 1 181 181 182 182 == 2.3 Connecting LT-22222-L to a Power Source == 183 183 184 - 185 185 The LT-22222-L I/O Controller can be powered by a **7–24V DC** power source. Connect your power supply’s **positive wire** to the **VIN** and the **negative wire** to the **GND** screw terminals. The power indicator **(PWR) LED** will turn on when the device is properly powered. 186 186 187 187 {{warning}} ... ... @@ -194,27 +194,23 @@ 194 194 195 195 = 3. Registering LT-22222-L with a LoRaWAN Network Server = 196 196 197 - 198 198 The LT-22222-L supports both OTAA (Over-the-Air Activation) and ABP (Activation By Personalization) methods to activate with a LoRaWAN Network Server. However, OTAA is the most secure method for activating a device with a LoRaWAN Network Server. OTAA regenerates session keys upon initial registration and regenerates new session keys after any subsequent reboots. By default, the LT-22222-L is configured to operate in LoRaWAN Class C mode. 199 199 200 200 201 -== 3.1 Prerequisites == 193 +=== 3.2.1 Prerequisites === 202 202 195 +The LT-22222-L comes with device registration information such as DevEUI, AppEUI, and AppKey that allows you to register it with a LoRaWAN network. These registration information can be found on a sticker that can be found inside the package. Please keep the **registration information** sticker in a safe place for future reference. 203 203 204 -The LT-22222-L comes with device registration information such as DevEUI, AppEUI, and AppKey which allows you to register it with a LoRaWAN network. This registration information can be found on a sticker that can be found inside the package. Please keep the **registration information** sticker in a safe place for future reference. 205 - 206 206 [[image:image-20230425173427-2.png||height="246" width="530"]] 207 207 208 208 {{info}} 209 -I fyou are unabletoset theprovided root key and other identifiers in the network server,youmustgeneratenew keysandidentifierswith the networkserverand configure thedevicewiththemusing ATcommands.200 +In case you can't set the root key and other identifiers in the network server and must use them from the server, you can use [[AT Commands>>||anchor="H4.UseATCommand"]] to configure them on the device. 210 210 {{/info}} 211 211 212 212 The following subsections explain how to register the LT-22222-L with different LoRaWAN network server providers. 213 213 205 +=== 3.2.2 The Things Stack === 214 214 215 -== 3.2 The Things Stack == 216 - 217 - 218 218 This section guides you through how to register your LT-22222-L with The Things Stack Sandbox. 219 219 220 220 {{info}} ... ... @@ -225,7 +225,7 @@ 225 225 The network diagram below illustrates the connection between the LT-22222-L and The Things Stack, as well as how the data can be integrated with the ThingsEye IoT platform. 226 226 227 227 228 -[[image:dragino-lorawan-nw-lt-22222-n.jpg ||height="374" width="1400"]]217 +[[image:dragino-lorawan-nw-lt-22222-n.jpg]] 229 229 230 230 {{info}} 231 231 You can use a LoRaWAN gateway, such as the [[Dragino LPS8N>>https://www.dragino.com/products/lora-lorawan-gateway/item/200-lps8n.html]], to expand or create LoRaWAN coverage in your area. ... ... @@ -232,9 +232,8 @@ 232 232 {{/info}} 233 233 234 234 235 -=== 3.2.1 Setting up === 224 +==== 3.2.2.1 Setting up ==== 236 236 237 - 238 238 * Sign up for a free account with [[The Things Stack Sandbox>>https://eu1.cloud.thethings.network]] if you do not have one yet. 239 239 * Log in to your The Things Stack Sandbox account. 240 240 * Create an **application** with The Things Stack if you do not have one yet (E.g., dragino-docs). ... ... @@ -241,9 +241,8 @@ 241 241 * Go to your application's page and click on the **End devices** in the left menu. 242 242 * On the End devices page, click on **+ Register end device**. Two registration options are available: 243 243 244 -==== 3.2. 1.1Using the LoRaWAN Device Repository ====232 +==== 3.2.2.2 Using the LoRaWAN Device Repository ==== 245 245 246 - 247 247 * On the **Register end device** page: 248 248 ** Select the option **Select the end device in the LoRaWAN Device Repository **under **Input method**. 249 249 ** Select the **End device brand**, **Model**, **Hardware version**, **Firmware version**, and **Profile (Region)** from the respective dropdown lists. ... ... @@ -261,21 +261,14 @@ 261 261 ** Enter the **AppEUI** in the **JoinEUI** field and click the **Confirm** button. If The Things Stack accepts the JoinEUI you provided, it will display the message 'This end device can be registered on the network'. 262 262 ** In the **DevEUI** field, enter the **DevEUI**. 263 263 ** In the **AppKey** field, enter the **AppKey.** 264 -** In the **End device ID** field, enter a unique name for your LT-22222- Lwithin this application.251 +** In the **End device ID** field, enter a unique name for your LT-22222-N within this application. 265 265 ** Under **After registration**, select the **View registered end device** option. 266 -** Click **Register end device** button. 267 267 268 268 [[image:lt-22222-l-dev-repo-reg-p2.png]] 269 269 270 270 271 - *Youwill benavigatedto the**Deviceoverview** page.257 +==== 3.2.2.3 Adding device manually ==== 272 272 273 -[[image:lt-22222-device-overview.png]] 274 - 275 - 276 -==== 3.2.1.2 Adding device manually ==== 277 - 278 - 279 279 * On the **Register end device** page: 280 280 ** Select the option **Enter end device specifies manually** under **Input method**. 281 281 ** Select the **Frequency plan** that matches your device from the **Frequency plan** dropdown list. ... ... @@ -305,11 +305,10 @@ 305 305 [[image:lt-22222-device-overview.png]] 306 306 307 307 308 -=== 3.2.2 Joining === 288 +==== 3.2.2.4 Joining ==== 309 309 290 +On the Device's page, click on **Live data** tab. The Live data panel for your device will display. 310 310 311 -On the end device's page (in this case, lt-22222-l), click on **Live data** tab. The Live data panel for your device will display. Initially, it is blank. 312 - 313 313 Now power on your LT-22222-L. The **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** The Things Stack network server. The **TX LED** will be on for **5 seconds** after joining the network. In the **Live data** panel, you can see the **join-request** and **join-accept** messages exchanged between the device and the network server. 314 314 315 315 ... ... @@ -316,17 +316,18 @@ 316 316 [[image:lt-22222-l-joining.png]] 317 317 318 318 319 -=== 3.2.3 Uplinks === 320 320 299 +==== 3.2.2.5 Uplinks ==== 321 321 322 -After successfully joining, the device will send its first **uplink data message** to The Things Stack application it belongs to (in this example, it is **dragino-docs**). When the LT-22222-L sends an uplink message to the server, the **TX LED** turns on for **1 second**. By default, you will receive an uplink data message from the device every 10 minutes. 323 323 324 - Clickononeofthe**Forward uplink data messages**toseeits payloadcontent.Thepayloadcontentisencapsulatedwithinthedecode_payload{}** JSONobject.302 +After successfully joining, the device will send its first **uplink data message** to the application it belongs to (in this example, **dragino-docs**). When the LT-22222-L sends an uplink message to the server, the **TX LED** turns on for **1 second**. By default, you will receive an uplink data message from the device every 10 minutes. 325 325 304 +Click on one of a **Forward uplink data messages **to see its payload content. The payload content is encapsulated within the decode_payload {} JSON object. 305 + 326 326 [[image:lt-22222-ul-payload-decoded.png]] 327 327 328 328 329 -If you can't see the decoded payload, it is because you haven't added the uplink formatter code. To add the uplink formatter code, select **Applications > [your application]> End devices** >[**your end device]** > **Payload formatters** > **Uplink**. Then select **Use Device repository formatters** for the **Formatter type** dropdown. Click the **Save changes** button to apply the changes.309 +If you can't see the decoded payload, it is because you haven't added the uplink formatter code. To add the uplink formatter code, select **Applications > your application > End devices** > **your end device** > **Payload formatters** > **Uplink**. Then select **Use Device repository formatters** for the **Formatter type** dropdown. Click the **Save changes** button to apply the changes. 330 330 331 331 {{info}} 332 332 The Things Stack provides two levels of payload formatters: application level and device level. The device-level payload formatters **override **the application-level payload formatters. ... ... @@ -335,18 +335,17 @@ 335 335 [[image:lt-22222-ul-payload-fmt.png]] 336 336 337 337 338 -We have writtena payload formatter that resolves some decoding issues present inTheThings StackDevice Repositorypayloadformatter. You can add it under the**Custom JavaScript formatter**. It can be found [[here>>https://github.com/dragino/dragino-end-node-decoder/blob/main/LT22222-L/v1.6_decoder_ttn%20.txt]]:318 +We also have a payload formatter that resolves some decoding issues present in the Device Repository formatter. You can add it under the Custom JavaScript formatter. It can be found [[here>>https://github.com/dragino/dragino-end-node-decoder/blob/main/LT22222-L/v1.6_decoder_ttn%20.txt]]: 339 339 340 340 (% class="wikigeneratedid" %) 341 341 [[image:lt-22222-l-js-custom-payload-formatter.png]] 342 342 343 343 344 -=== 3.2. 4Downlinks ===324 +==== 3.2.2.6 Downlinks ==== 345 345 326 +When the LT-22222-L receives a downlink message from the server, the **RX LED** turns on for **1 second**. 346 346 347 -When the LT-22222-L receives a downlink message from the LoRaWAN Network Server, the **RX LED** turns on for **1 second**. 348 348 349 - 350 350 == 3.3 Working Modes and Uplink Payload formats == 351 351 352 352 ... ... @@ -366,16 +366,17 @@ 366 366 367 367 The uplink messages are sent over LoRaWAN FPort=2. By default, an uplink message is sent every 10 minutes. 368 368 369 - 370 370 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 371 371 372 - 373 373 ((( 374 374 This is the default mode. 375 375 376 376 The uplink payload is 11 bytes long. 377 -(% style="display:none" wfd-invisible="true" %) 378 378 355 +(% style="color:red" %)**Note:The maximum count depends on the bytes number of bytes. 356 +The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 357 +It starts counting again when it reaches the maximum value.**(% style="display:none" wfd-invisible="true" %) 358 + 379 379 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 380 380 |(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** 381 381 |Value|((( ... ... @@ -439,7 +439,6 @@ 439 439 440 440 MOD = 1 441 441 442 - 443 443 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 444 444 445 445 ... ... @@ -518,7 +518,6 @@ 518 518 519 519 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 520 520 521 - 522 522 (% style="color:red" %)**Note: The maximum count depends on the bytes it is. 523 523 The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 524 524 It starts counting again when it reaches the maximum value.** ... ... @@ -572,7 +572,6 @@ 572 572 573 573 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 574 574 575 - 576 576 (% style="color:red" %)**Note:The maximum count depends on the bytes it is. 577 577 The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 578 578 It starts counting again when it reaches the maximum value.** ... ... @@ -642,9 +642,8 @@ 642 642 643 643 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 644 644 645 - 646 646 (% style="color:red" %)**Note:The maximum count depends on the bytes it is. 647 -The maximum count for four bytes is FFFF (hex) = 65 535(dec).623 +The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 648 648 It starts counting again when it reaches the maximum value.** 649 649 650 650 ... ... @@ -729,7 +729,7 @@ 729 729 730 730 AT+AVLIM=3000,6000,0,2000 (triggers an uplink if AVI1 voltage is lower than 3V or higher than 6V, or if AV2 voltage is higher than 2V) 731 731 732 -AT+AVLIM=5000,0,0,0 (triggers an uplink if AVI1 voltage islower than 5V. Use 0 for parameters that are not in use)708 +AT+AVLIM=5000,0,0,0 (triggers an uplink if AVI1 voltage lower than 5V. Use 0 for parameters that are not in use) 733 733 734 734 735 735 (% style="color:#4f81bd" %)**Trigger based on current**: ... ... @@ -785,7 +785,7 @@ 785 785 786 786 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 787 787 788 -MOD6 Payload: atotal of 11 bytes764 +MOD6 Payload: total of 11 bytes 789 789 790 790 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:515px" %) 791 791 |(% style="background-color:#4f81bd; color:white; width:60px" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white; width:69px" %)**1**|(% style="background-color:#4f81bd; color:white; width:69px" %)**1**|(% style="background-color:#4f81bd; color:white; width:109px" %)**1**|(% style="background-color:#4f81bd; color:white; width:49px" %)**6**|(% style="background-color:#4f81bd; color:white; width:109px" %)**1**|(% style="background-color:#4f81bd; color:white; width:50px" %)**1** ... ... @@ -799,7 +799,7 @@ 799 799 MOD(6) 800 800 ))) 801 801 802 -(% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if the trigger is set for this part. Total 1 byte as below .778 +(% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if the trigger is set for this part. Totally 1 byte as below 803 803 804 804 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:515px" %) 805 805 |**bit 7**|**bit 6**|**bit 5**|**bit 4**|**bit 3**|**bit 2**|**bit 1**|**bit 0** ... ... @@ -828,7 +828,7 @@ 828 828 10100000: This means the system is configured to use the triggers AV1_LOW and AV2_LOW. 829 829 830 830 831 -(% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger ed. Total 1 byte as below.807 +(% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1 byte as below 832 832 833 833 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:515px" %) 834 834 |**bit 7**|**bit 6**|**bit 5**|**bit 4**|**bit 3**|**bit 2**|**bit 1**|**bit 0** ... ... @@ -857,7 +857,7 @@ 857 857 10000000: The uplink is triggered by AV1_LOW, indicating that the voltage is too low. 858 858 859 859 860 -(% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger ed. Total 1.836 +(% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 861 861 862 862 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:515px" %) 863 863 |(% style="width:50px" %)**bit 7**|(% style="width:50px" %)**bit 6**|(% style="width:50px" %)**bit 5**|(% style="width:50px" %)**bit 4**|(% style="width:90px" %)**bit 3**|(% style="width:80px" %)**bit 2**|(% style="width:90px" %)**bit 1**|(% style="width:95px" %)**bit 0** ... ... @@ -867,7 +867,7 @@ 867 867 868 868 **Example:** 869 869 870 -00000111: This means both DI1 and DI2 triggers are enabled, and this packet is trigger edby DI1.846 +00000111: This means both DI1 and DI2 triggers are enabled, and this packet is trigger by DI1. 871 871 872 872 00000101: This means both DI1 and DI2 triggers are enabled. 873 873 ... ... @@ -878,7 +878,7 @@ 878 878 879 879 **AB 06** 880 880 881 -When thedevice receives this command, it will send the MOD6 payload.857 +When device receives this command, it will send the MOD6 payload. 882 882 883 883 884 884 === 3.3.7 Payload Decoder === ... ... @@ -892,7 +892,6 @@ 892 892 893 893 == 3.4 Configure LT-22222-L via AT Commands or Downlinks == 894 894 895 - 896 896 ((( 897 897 You can configure LT-22222-L I/O Controller via AT Commands or LoRaWAN Downlinks. 898 898 ))) ... ... @@ -899,7 +899,7 @@ 899 899 900 900 ((( 901 901 ((( 902 -There are two ty pes of commands:877 +There are two tytes of commands: 903 903 ))) 904 904 ))) 905 905 ... ... @@ -909,22 +909,17 @@ 909 909 910 910 === 3.4.1 Common commands === 911 911 912 - 913 913 ((( 914 -These are available for each sensor and include actions such as changing the uplink interval or resetting the device. For firmware v1.5.4, you can find the supported common commands under: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]s. 915 - 916 - 888 +These are available for each sensors and include actions such as changing the uplink interval or resetting the device. For firmware v1.5.4, you can find the supported common commands under: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]s. 917 917 ))) 918 918 919 919 === 3.4.2 Sensor-related commands === 920 920 921 - 922 922 These commands are specially designed for the LT-22222-L. Commands can be sent to the device using options such as an AT command or a LoRaWAN downlink payload. 923 923 924 924 925 925 ==== 3.4.2.1 Set Transmit/Uplink Interval ==== 926 926 927 - 928 928 Sets the uplink interval of the device. The default uplink transmission interval is 10 minutes. 929 929 930 930 (% style="color:#037691" %)**AT command** ... ... @@ -971,7 +971,6 @@ 971 971 972 972 ==== 3.4.2.2 Set the Working Mode (AT+MOD) ==== 973 973 974 - 975 975 Sets the working mode. 976 976 977 977 (% style="color:#037691" %)**AT command** ... ... @@ -1029,7 +1029,6 @@ 1029 1029 1030 1030 ==== 3.4.2.3 Request an uplink from the device ==== 1031 1031 1032 - 1033 1033 Requests an uplink from LT-22222-L. The content of the uplink payload varies based on the device's current working mode. 1034 1034 1035 1035 (% style="color:#037691" %)**AT command** ... ... @@ -1049,7 +1049,6 @@ 1049 1049 1050 1050 ==== 3.4.2.4 Enable/Disable Trigger Mode ==== 1051 1051 1052 - 1053 1053 Enable or disable the trigger mode for the current working mode (see also [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]). 1054 1054 1055 1055 (% style="color:#037691" %)**AT Command** ... ... @@ -1087,7 +1087,6 @@ 1087 1087 1088 1088 ==== 3.4.2.5 Request trigger settings ==== 1089 1089 1090 - 1091 1091 Requests the trigger settings. 1092 1092 1093 1093 (% style="color:#037691" %)**AT Command:** ... ... @@ -1102,12 +1102,11 @@ 1102 1102 |(% style="width:95px" %)**Example**|(% style="width:403px" %)((( 1103 1103 AB 06 1104 1104 1105 -Uplink the trigger settings. 1071 +Uplinks the trigger settings. 1106 1106 ))) 1107 1107 1108 1108 ==== 3.4.2.6 Enable/Disable DI1/DI2/DI3 as a trigger ==== 1109 1109 1110 - 1111 1111 Enable or disable DI1/DI2/DI3 as a trigger. 1112 1112 1113 1113 (% style="color:#037691" %)**AT Command** ... ... @@ -1160,11 +1160,11 @@ 1160 1160 Enable DI1 trigger, disable DI2 trigger 1161 1161 ))) 1162 1162 1163 -==== 3.4.2.7 Trigger1 – Set DI 1or DI3 as a trigger ====1128 +==== 3.4.2.7 Trigger1 – Set DI or DI3 as a trigger ==== 1164 1164 1165 - 1166 1166 Sets DI1 or DI3 (for LT-33222-L) as a trigger. 1167 1167 1132 + 1168 1168 (% style="color:#037691" %)**AT Command** 1169 1169 1170 1170 (% border="2" style="width:500px" %) ... ... @@ -1201,9 +1201,9 @@ 1201 1201 1202 1202 ==== 3.4.2.8 Trigger2 – Set DI2 as a trigger ==== 1203 1203 1204 - 1205 1205 Sets DI2 as a trigger. 1206 1206 1171 + 1207 1207 (% style="color:#037691" %)**AT Command** 1208 1208 1209 1209 (% border="2" style="width:500px" %) ... ... @@ -1235,7 +1235,6 @@ 1235 1235 1236 1236 ==== 3.4.2.9 Trigger – Set AC (current) as a trigger ==== 1237 1237 1238 - 1239 1239 Sets the current trigger based on the AC port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1240 1240 1241 1241 (% style="color:#037691" %)**AT Command** ... ... @@ -1285,7 +1285,6 @@ 1285 1285 1286 1286 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 1287 1287 1288 - 1289 1289 Sets the current trigger based on the AV port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1290 1290 1291 1291 (% style="color:#037691" %)**AT Command** ... ... @@ -1331,9 +1331,8 @@ 1331 1331 ))) 1332 1332 |(% style="width:104px" %)**Note**|(% style="width:394px" %)See also, [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1333 1333 1334 -==== 3.4.2.11 Trigger – Set theminimum interval ====1297 +==== 3.4.2.11 Trigger – Set minimum interval ==== 1335 1335 1336 - 1337 1337 Sets the AV and AC trigger minimum interval. The device won't respond to a second trigger within this set time after the first trigger. 1338 1338 1339 1339 (% style="color:#037691" %)**AT Command** ... ... @@ -1369,7 +1369,6 @@ 1369 1369 1370 1370 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1371 1371 1372 - 1373 1373 Controls the digital outputs DO1, DO2, and DO3 1374 1374 1375 1375 (% style="color:#037691" %)**AT Command** ... ... @@ -1421,140 +1421,125 @@ 1421 1421 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1422 1422 1423 1423 1424 -(% style="color:#037691" %)**AT command**1385 +* (% style="color:#037691" %)**AT Command** 1425 1425 1426 1426 There is no AT command to control the digital output. 1427 1427 1428 1428 1429 -(% style="color:#037691" %)**Downlink payload**1390 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)** 1430 1430 1392 +(% style="color:blue" %)**0xA9 aa bb cc **(%%) ~/~/ Sets DO1/DO2/DO3 outputs with time control 1431 1431 1432 -(% border="2" style="width:500px" %) 1433 -|(% style="width:116px" %)**Prefix**|(% style="width:382px" %)0xA9 1434 -|(% style="width:116px" %)**Parameters**|(% style="width:382px" %)((( 1435 -**inverter_mode**: 1 byte in hex. 1394 +This is to control the digital output time of DO pin. Include four bytes: 1436 1436 1396 +(% style="color:#4f81bd" %)**First byte**(%%)**:** Type code (0xA9) 1397 + 1398 +(% style="color:#4f81bd" %)**Second byte**(%%): Inverter Mode 1399 + 1437 1437 **01:** DO pins revert to their original state after the timeout. 1438 1438 **00:** DO pins switch to an inverted state after the timeout. 1439 1439 1440 1440 1441 -** DO1_control_method_and_port_status**- 1 byte in hex1404 +(% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Port status: 1442 1442 1443 -0x01 : DO1 set to low 1406 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1407 +|(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status** 1408 +|0x01|DO1 set to low 1409 +|0x00|DO1 set to high 1410 +|0x11|DO1 NO Action 1444 1444 1445 - 0x00:DO1set to high1412 +(% style="color:#4f81bd" %)**Fourth byte**(%%): Control Method and Port status: 1446 1446 1447 -0x11 : DO1 NO action 1414 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1415 +|(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status** 1416 +|0x01|DO2 set to low 1417 +|0x00|DO2 set to high 1418 +|0x11|DO2 NO Action 1448 1448 1420 +(% style="color:#4f81bd" %)**Fifth byte**(%%): Control Method and Port status: 1449 1449 1450 -**DO2_control_method_and_port_status** - 1 byte in hex 1422 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1423 +|(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status** 1424 +|0x01|DO3 set to low 1425 +|0x00|DO3 set to high 1426 +|0x11|DO3 NO Action 1451 1451 1452 - 0x01:DO2set tolow1428 +(% style="color:#4f81bd" %)**Sixth, Seventh, Eighth, and Ninth bytes**:(%%) Latching time (Unit: ms) 1453 1453 1454 -0x00 : DO2 set to high 1455 1455 1456 -0x11 : DO2 NO action 1457 - 1458 - 1459 -**DO3_control_method_and_port_status **- 1 byte in hex 1460 - 1461 -0x01 : DO3 set to low 1462 - 1463 -0x00 : DO3 set to high 1464 - 1465 -0x11 : DO3 NO action 1466 - 1467 - 1468 -**latching_time** : 4 bytes in hex 1469 - 1470 1470 (% style="color:red" %)**Note: ** 1471 1471 1472 - Since firmware v1.6.0, the latch time support s4 bytesor2 bytes1433 + Since firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1473 1473 1474 1474 Before firmware v1.6.0, the latch time only supported 2 bytes. 1475 1475 1476 1476 (% style="color:red" %)**The device will uplink a packet if the downlink code executes successfully.** 1477 -))) 1478 -|(% style="width:116px" %)**Payload format**|(% style="width:382px" %)<prefix><inverter_mode><DO1_control_method_and_port_status><DO2_control_method_and_port_status><DO2_control_method_and_port_status><latching_time> 1479 -|(% style="width:116px" %)**Example**|(% style="width:382px" %)((( 1480 -**A9 01 01 01 01 07 D0** 1481 1481 1482 -DO1 pin, DO2 pin, and DO3 pin will be set to low, last for 2 seconds, and then revert to their original state. 1483 1483 1440 +**Example payload:** 1484 1484 1485 -**A9 01 0 001 1107 D0**1442 +**~1. A9 01 01 01 01 07 D0** 1486 1486 1487 -DO1 pin is set to high, DO2 pinis set to low, and DO3 pintakesnoaction.Thislastsfor 2 seconds and then revertsto the original state.1444 +DO1 pin, DO2 pin, and DO3 pin will be set to low, last for 2 seconds, and then revert to their original state. 1488 1488 1446 +**2. A9 01 00 01 11 07 D0** 1489 1489 1490 - **A90000000007D0**1448 +DO1 pin is set to high, DO2 pin is set to low, and DO3 pin takes no action. This lasts for 2 seconds and then reverts to the original state. 1491 1491 1450 +**3. A9 00 00 00 00 07 D0** 1451 + 1492 1492 DO1 pin, DO2 pin, and DO3 pin will be set to high, last for 2 seconds, and then all change to low. 1493 1493 1454 +**4. A9 00 11 01 00 07 D0** 1494 1494 1495 - **A90011010007D0**1456 +DO1 pin takes no action, DO2 pin is set to low, and DO3 pin is set to high. This lasts for 2 seconds, after which DO1 pin takes no action, DO2 pin is set to high, and DO3 pin is set to low. 1496 1496 1497 -DO1 pin takes no action, DO2 pin is set to low, and DO3 pin is set to high. This lasts for 2 seconds, after which the DO1 pin takes no action, the DO2 pin is set to high, and the DO3 pin is set to low. 1498 -))) 1499 1499 1500 1500 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1501 1501 1502 1502 1503 -(% style="color:#037691" %)**AT Command:** 1462 +* (% style="color:#037691" %)**AT Command:** 1504 1504 1505 -There is no AT Command to control the Relay Output .1464 +There is no AT Command to control the Relay Output 1506 1506 1507 1507 1508 -(% style="color:#037691" %)**Downlink Payload** 1467 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):** 1509 1509 1510 -(% border="2" style="width:500px" %) 1511 -|(% style="width:113px" %)**Prefix**|(% style="width:384px" %)0x03 1512 -|(% style="width:113px" %)**Parameters**|(% style="width:384px" %)((( 1513 -**RO1_status** : 1 byte in hex 1469 +(% style="color:blue" %)**0x03 aa bb ** (%%)~/~/ Sets RO1/RO2 output 1514 1514 1515 -00: Close 1516 1516 1517 -01: Open 1472 +((( 1473 +If the payload is 0x030100, it means setting RO1 to close and RO2 to open. 1474 +))) 1518 1518 1519 -11: No action 1476 +((( 1477 +00: Close , 01: Open , 11: No action 1520 1520 1521 - 1522 -**RO2_status** : 1 byte in hex 1523 - 1524 -00: Close 1525 - 1526 -01: Open 1527 - 1528 -11: No action 1479 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:320px" %) 1480 +|(% style="background-color:#4f81bd; color:white" %)**Downlink Code**|(% style="background-color:#4f81bd; color:white" %)**RO1**|(% style="background-color:#4f81bd; color:white" %)**RO2** 1481 +|03 00 11|Open|No Action 1482 +|03 01 11|Close|No Action 1483 +|03 11 00|No Action|Open 1484 +|03 11 01|No Action|Close 1485 +|03 00 00|Open|Open 1486 +|03 01 01|Close|Close 1487 +|03 01 00|Close|Open 1488 +|03 00 01|Open|Close 1529 1529 ))) 1530 -|(% style="width:113px" %)**Payload format**|(% style="width:384px" %)<prefix><RO1_status><RO2_status> 1531 -|(% style="width:113px" %)**Example**|(% style="width:384px" %)((( 1532 -(% border="2" %) 1533 -|=Payload|=RO1|=RO2 1534 -|03 00 11|Open|No action 1535 -|03 01 11|Close|No action 1536 -|03 11 00|No action|Open 1537 -|03 11 01|No action|Close 1538 -|03 00 00|Open|Open 1539 -|03 01 01|Close|Close 1540 -|03 01 00|Close|Open 1541 -|03 00 01|Open|Close 1542 1542 1543 -(% style="color:red" %)**The device will transmit an uplink packet if the downlink payload is executed successfully.** 1544 -))) 1491 +(% style="color:red" %)**The device will uplink a packet if the downlink code executes successfully.** 1545 1545 1493 + 1546 1546 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1547 1547 1548 - 1549 1549 Controls the relay output time. 1550 1550 1498 +* (% style="color:#037691" %)**AT Command:** 1551 1551 1552 -(% style="color:#037691" %)**AT Command:** 1553 - 1554 1554 There is no AT Command to control the Relay Output 1555 1555 1556 1556 1557 -(% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1503 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1558 1558 1559 1559 (% style="color:blue" %)**0x05 aa bb cc dd ** (%%)~/~/ Sets RO1/RO2 relays with time control 1560 1560 ... ... @@ -1565,9 +1565,9 @@ 1565 1565 1566 1566 (% style="color:#4f81bd" %)**Second byte (aa)**(%%): Inverter Mode 1567 1567 1568 -01: Relays will change back to their original state after atimeout.1514 +01: Relays will change back to their original state after timeout. 1569 1569 1570 -00: Relays will change to the inverter state after atimeout.1516 +00: Relays will change to the inverter state after timeout. 1571 1571 1572 1572 1573 1573 (% style="color:#4f81bd" %)**Third byte (bb)**(%%): Control Method and Ports status: ... ... @@ -1596,7 +1596,7 @@ 1596 1596 1597 1597 **2. 05 01 10 07 D0** 1598 1598 1599 -Relay1 will change to NC, Relay2 will change to NO, lasting 2 seconds, andthen both will revert to their original state.1545 +Relay1 will change to NC, Relay2 will change to NO, lasting 2 seconds, then both will revert to their original state. 1600 1600 1601 1601 **3. 05 00 01 07 D0** 1602 1602 ... ... @@ -1627,7 +1627,7 @@ 1627 1627 1628 1628 **1**: higher than 1629 1629 1630 -if you leave thelogic parameter blank, it is considered 01576 +if you leave logic parameter blank, it is considered 0 1631 1631 ))) 1632 1632 |(% style="width:137px" %)**Examples**|(% style="width:361px" %)((( 1633 1633 AT+VOLMAX=20000 ... ... @@ -1658,7 +1658,7 @@ 1658 1658 1659 1659 **1**: higher than 1660 1660 1661 -if you leave thelogic parameter blank, it is considered 1 (higher than)1607 +if you leave logic parameter blank, it is considered 1 (higher than) 1662 1662 ))) 1663 1663 |(% style="width:140px" %)**Example**|(% style="width:358px" %)((( 1664 1664 A5 **4E 20** ... ... @@ -1746,7 +1746,6 @@ 1746 1746 1747 1747 ==== 3.4.2.19 Counting ~-~- Set Saving Interval for 'Counting Result' ==== 1748 1748 1749 - 1750 1750 This command allows you to configure the device to save its counting result to internal flash memory at specified intervals. By setting a save time, the device will periodically store the counting data to prevent loss in case of power failure. The save interval can be adjusted to suit your requirements, with a minimum value of 30 seconds. 1751 1751 1752 1752 (% style="color:#037691" %)**AT Command** ... ... @@ -1778,7 +1778,6 @@ 1778 1778 1779 1779 ==== 3.4.2.20 Reset saved RO and DO states ==== 1780 1780 1781 - 1782 1782 This command allows you to reset the saved relay output (RO) and digital output (DO) states when the device joins the network. By configuring this setting, you can control whether the device should retain or reset the relay states after a reset and rejoin to the network. 1783 1783 1784 1784 (% style="color:#037691" %)**AT Command** ... ... @@ -1828,7 +1828,6 @@ 1828 1828 1829 1829 ==== 3.4.2.21 Encrypted payload ==== 1830 1830 1831 - 1832 1832 This command allows you to configure whether the device should upload data in an encrypted format or in plaintext. By default, the device encrypts the payload before uploading. You can toggle this setting to either upload encrypted data or transmit it without encryption. 1833 1833 1834 1834 (% style="color:#037691" %)**AT Command:** ... ... @@ -1858,7 +1858,6 @@ 1858 1858 1859 1859 ==== 3.4.2.22 Get sensor value ==== 1860 1860 1861 - 1862 1862 This command allows you to retrieve and optionally uplink sensor readings through the serial port. 1863 1863 1864 1864 (% style="color:#037691" %)**AT Command** ... ... @@ -1888,7 +1888,6 @@ 1888 1888 1889 1889 ==== 3.4.2.23 Resetting the downlink packet count ==== 1890 1890 1891 - 1892 1892 This command manages how the node handles mismatched downlink packet counts. It offers two modes: one disables the reception of further downlink packets if discrepancies occur, while the other resets the downlink packet count to align with the server, ensuring continued communication. 1893 1893 1894 1894 (% style="color:#037691" %)**AT Command** ... ... @@ -1922,7 +1922,7 @@ 1922 1922 ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1923 1923 1924 1924 1925 -This command controls the behavior of the node when the combined size of the MAC commands (MACANS) from the server and the payload exceed the allowed byte limit for the current data rate (DR). The command provides two modes: one enables splitting the data into batches to ensure compliance with the byte limit, while the other prioritizes the payload and ignores the MACANS in cases of overflow. 1866 +This command controls the behavior of the node when the combined size of the MAC commands (MACANS) from the server and the payload exceeds the allowed byte limit for the current data rate (DR). The command provides two modes: one enables splitting the data into batches to ensure compliance with the byte limit, while the other prioritizes the payload and ignores the MACANS in cases of overflow. 1926 1926 1927 1927 (% style="color:#037691" %)**AT Command** 1928 1928 ... ... @@ -1967,7 +1967,6 @@ 1967 1967 1968 1968 ==== 3.4.2.25 Copy downlink to uplink ==== 1969 1969 1970 - 1971 1971 This command enables the device to immediately uplink the payload of a received downlink packet back to the server. The command allows for quick data replication from downlink to uplink, with a fixed port number of 100. 1972 1972 1973 1973 (% style="color:#037691" %)**AT Command**(%%)**:** ... ... @@ -1991,15 +1991,14 @@ 1991 1991 There is no downlink option available for this feature. 1992 1992 1993 1993 1994 -==== 3.4.2.26 Query firmware version, frequency band, subband, and TDC time ==== 1934 +==== 3.4.2.26 Query firmware version, frequency band, sub band, and TDC time ==== 1995 1995 1936 +This command is used to query key information about the device, including its firmware version, frequency band, sub band, and TDC time. By sending the specified payload as a downlink, the server can retrieve this essential data from the device. 1996 1996 1997 -This command is used to query key information about the device, including its firmware version, frequency band, subband, and TDC time. By sending the specified payload as a downlink, the server can retrieve this essential data from the device. 1998 - 1999 1999 * ((( 2000 2000 (% style="color:#037691" %)**Downlink Payload**(%%)**:** 2001 2001 2002 -(% style="color:blue" %)**26 01 ** (%%) ~/~/ The downlink payload 26 01 is used to query the device's firmware version, frequency band, subband, and TDC time. 1941 +(% style="color:blue" %)**26 01 ** (%%) ~/~/ The downlink payload 26 01 is used to query the device's firmware version, frequency band, sub band, and TDC time. 2003 2003 2004 2004 2005 2005 ... ... @@ -2012,13 +2012,10 @@ 2012 2012 2013 2013 == 3.5 Integrating with ThingsEye.io == 2014 2014 2015 - 2016 2016 The Things Stack application supports integration with ThingsEye.io. Once integrated, ThingsEye.io acts as an MQTT client for The Things Stack MQTT broker, allowing it to subscribe to upstream traffic and publish downlink traffic. 2017 2017 2018 - 2019 2019 === 3.5.1 Configuring The Things Stack === 2020 2020 2021 - 2022 2022 We use The Things Stack Sandbox in this example: 2023 2023 2024 2024 * In **The Things Stack Sandbox**, go to the **Application **for the LT-22222-L you added. ... ... @@ -2032,10 +2032,8 @@ 2032 2032 2033 2033 [[image:tts-mqtt-integration.png]] 2034 2034 2035 - 2036 2036 === 3.5.2 Configuring ThingsEye.io === 2037 2037 2038 - 2039 2039 The ThingsEye.io IoT platform is not open for self-registration at the moment. If you are interested in testing the platform, please send your project information to admin@thingseye.io, and we will create an account for you. 2040 2040 2041 2041 * Login to your [[ThingsEye.io >>https://thingseye.io]]account. ... ... @@ -2054,7 +2054,7 @@ 2054 2054 * Ensure the following options are turned on. 2055 2055 ** Enable integration 2056 2056 ** Debug mode 2057 -** Allow creat ingdevices or assets1991 +** Allow create devices or assets 2058 2058 * Click the **Next** button. you will be navigated to the **Uplink data converter** tab. 2059 2059 2060 2060 [[image:thingseye-io-step-2.png]] ... ... @@ -2105,7 +2105,6 @@ 2105 2105 2106 2106 ==== 3.5.2.1 Viewing integration details ==== 2107 2107 2108 - 2109 2109 Click on your integration from the list. The **Integration details** window will appear with the **Details **tab selected. The **Details **tab shows all the settings you have provided for this integration. 2110 2110 2111 2111 [[image:integration-details.png]] ... ... @@ -2117,10 +2117,8 @@ 2117 2117 See also [[ThingsEye documentation>>https://wiki.thingseye.io/xwiki/bin/view/Main/]]. 2118 2118 {{/info}} 2119 2119 2053 +==== **3.5.2.2 Viewing events** ==== 2120 2120 2121 -==== 3.5.2.2 Viewing events ==== 2122 - 2123 - 2124 2124 The **Events **tab displays all the uplink messages from the LT-22222-L. 2125 2125 2126 2126 * Select **Debug **from the **Event type** dropdown. ... ... @@ -2129,27 +2129,21 @@ 2129 2129 [[image:thingseye-events.png]] 2130 2130 2131 2131 2132 -* To view the **JSON payload** of a message, click on the **three dots (...)** in the **Message**column of the desired message.2063 +* To view the **JSON payload** of a message, click on the **three dots (...)** in the Message column of the desired message. 2133 2133 2134 2134 [[image:thingseye-json.png]] 2135 2135 2136 2136 2137 -==== 3.5.2.3 Deleting an integration ==== 2068 +==== **3.5.2.3 Deleting an integration** ==== 2138 2138 2139 - 2140 2140 If you want to delete an integration, click the **Delete integratio**n button on the Integrations page. 2141 2141 2142 2142 2143 -==== 3.5.2.4 Viewing sensorataon adashboard====2073 +==== 3.5.2.4 Creating a Dashboard to Display and Analyze LT-22222-L Data ==== 2144 2144 2075 +This will be added soon. 2145 2145 2146 -You can create a dashboard with ThingsEye to visualize the sensor data coming from the LT-22222-L. The following image shows a dashboard created for the LT-22222-L. See **Creating a dashboard** in ThingsEye documentation for more information. 2147 2147 2148 - 2149 - 2150 -[[image:lt-22222-l-dashboard.png]] 2151 - 2152 - 2153 2153 == 3.6 Interface Details == 2154 2154 2155 2155 === 3.6.1 Digital Input Ports: DI1/DI2/DI3 (For LT-33222-L, Low Active) === ... ... @@ -2363,19 +2363,18 @@ 2363 2363 2364 2364 == 3.7 LED Indicators == 2365 2365 2291 +The table below lists the behavior of LED indicators for each port function. 2366 2366 2367 -The table below lists the behaviour of LED indicators for each port function. 2368 - 2369 2369 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 2370 2370 |(% style="background-color:#4f81bd; color:white; width:50px" %)**LEDs**|(% style="background-color:#4f81bd; color:white; width:460px" %)**Feature** 2371 2371 |**PWR**|Always on when there is power 2372 2372 |**TX**|((( 2373 2373 ((( 2374 -Device boot ing: TX blinks 5 times.2298 +Device boot: TX blinks 5 times. 2375 2375 ))) 2376 2376 2377 2377 ((( 2378 -Successful network join s: TX remains ON for 5 seconds.2302 +Successful network join: TX remains ON for 5 seconds. 2379 2379 ))) 2380 2380 2381 2381 ((( ... ... @@ -2396,13 +2396,10 @@ 2396 2396 2397 2397 = 4. Using AT Commands = 2398 2398 2399 - 2400 2400 The LT-22222-L supports programming using AT Commands. 2401 2401 2402 - 2403 2403 == 4.1 Connecting the LT-22222-L to a PC == 2404 2404 2405 - 2406 2406 ((( 2407 2407 You can use a USB-to-TTL adapter/converter along with a 3.5mm Program Cable to connect the LT-22222-L to a PC, as shown below. 2408 2408 ... ... @@ -2422,10 +2422,7 @@ 2422 2422 ((( 2423 2423 You can find more details in the [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 2424 2424 2425 - 2426 2426 == 4.2 LT-22222-L related AT commands == 2427 - 2428 - 2429 2429 ))) 2430 2430 2431 2431 ((( ... ... @@ -2459,13 +2459,13 @@ 2459 2459 * ##**AT+FCU**##: Get or set the Frame Counter Uplink (FCntUp) 2460 2460 * ##**AT+FCD**##: Get or set the Frame Counter Downlink (FCntDown) 2461 2461 * ##**AT+CLASS**##: Get or set the Device Class 2462 -* ##**AT+JOIN**##: Join Network2380 +* ##**AT+JOIN**##: Join network 2463 2463 * ##**AT+NJS**##: Get OTAA Join Status 2464 2464 * ##**AT+SENDB**##: Send hexadecimal data along with the application port 2465 2465 * ##**AT+SEND**##: Send text data along with the application port 2466 -* ##**AT+RECVB**##: Print thelast received data in binary format (with hexadecimal values)2467 -* ##**AT+RECV**##: Print thelast received data in raw format2468 -* ##**AT+VER**##: Get thecurrent image version and Frequency Band2384 +* ##**AT+RECVB**##: Print last received data in binary format (with hexadecimal values) 2385 +* ##**AT+RECV**##: Print last received data in raw format 2386 +* ##**AT+VER**##: Get current image version and Frequency Band 2469 2469 * ##**AT+CFM**##: Get or Set the confirmation mode (0-1) 2470 2470 * ##**AT+CFS**##: Get confirmation status of the last AT+SEND (0-1) 2471 2471 * ##**AT+SNR**##: Get the SNR of the last received packet ... ... @@ -2493,7 +2493,7 @@ 2493 2493 ))) 2494 2494 2495 2495 ((( 2496 -(% style="background-color:#dcdcdc" %)##**123456 ~/~/Enter the password to enable AT command access**## 2414 +(% style="background-color:#dcdcdc" %)##**123456 ~/~/Enter the password to enable AT commands access**## 2497 2497 ))) 2498 2498 2499 2499 ((( ... ... @@ -2501,7 +2501,7 @@ 2501 2501 ))) 2502 2502 2503 2503 ((( 2504 -(% style="background-color:#dcdcdc" %)##**123456 ~/~/Enter the password to enable AT command access**## 2422 +(% style="background-color:#dcdcdc" %)##**123456 ~/~/Enter the password to enable AT commands access**## 2505 2505 ))) 2506 2506 2507 2507 ((( ... ... @@ -2532,7 +2532,7 @@ 2532 2532 2533 2533 2534 2534 ((( 2535 -(% style="background-color:#dcdcdc" %)**123456**(%%) ~/~/ Enter thepassword to enable AT commands access2453 +(% style="background-color:#dcdcdc" %)**123456**(%%) ~/~/ Enter password to enable AT commands access 2536 2536 ))) 2537 2537 ))) 2538 2538 ... ... @@ -2541,7 +2541,7 @@ 2541 2541 ))) 2542 2542 2543 2543 ((( 2544 -(% style="background-color:#dcdcdc" %)** 123456**(%%) ~/~/ Enter thepassword to enable AT command access2462 +(% style="background-color:#dcdcdc" %)** 123456**(%%) ~/~/ Enter password to enable AT commands access 2545 2545 ))) 2546 2546 2547 2547 ((( ... ... @@ -2595,7 +2595,8 @@ 2595 2595 2596 2596 **2. Verify that the LG01/02 gateway RX frequency matches the AT+CHS setting exactly.** 2597 2597 2598 -**3. Make sure the SF/bandwidth settings in the LG01/LG02 match the settings of AT+DR. Refer to [[this link>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 2516 +**3. Make sure the SF/bandwidth settings in the LG01/LG02 match the settings of AT+DR. Refer to [[this link>>url:http://www.dragino.com/downloads/index.php? 2517 +dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 2599 2599 2600 2600 **4. The commands AT+RX2FQ and AT+RX2DR enable downlink functionality. To set the correct parameters, you can check the actual downlink parameters to be used as shown below. Here, RX2FQ should be set to 868400000 and RX2DR should be set to 5.** 2601 2601 ))) ... ... @@ -2621,19 +2621,16 @@ 2621 2621 2622 2622 == 5.1 Counting how many objects pass through the flow line == 2623 2623 2543 +See [[How to set up to setup counting for objects passing through the flow line>>How to set up to count objects pass in flow line]]? 2624 2624 2625 -See [[How to set up to setup counting for objects passing through the flow line>>How to set up to count objects pass in flow line]]. 2626 2626 2627 - 2628 2628 = 6. FAQ = 2629 2629 2630 - 2631 2631 This section contains some frequently asked questions, which can help you resolve common issues and find solutions quickly. 2632 2632 2633 2633 2634 2634 == 6.1 How to update the firmware? == 2635 2635 2636 - 2637 2637 Dragino frequently releases firmware updates for the LT-22222-L. Updating your LT-22222-L with the latest firmware version helps to: 2638 2638 2639 2639 * Support new features ... ... @@ -2686,21 +2686,17 @@ 2686 2686 ((( 2687 2687 ((( 2688 2688 == 6.2 How to change the LoRaWAN frequency band/region? == 2689 - 2690 - 2691 2691 ))) 2692 2692 ))) 2693 2693 2694 2694 ((( 2695 -You can follow the introductions on [[how to upgrade theimage>>||anchor="H6.1Howtoupdatethefirmware3F"]]. When downloading, select the required image file.2609 +You can follow the introductions on [[how to upgrade image>>||anchor="H5.1Howtoupgradetheimage3F"]]. When downloading, select the required image file. 2696 2696 ))) 2697 2697 2698 2698 ((( 2699 2699 2700 2700 2701 -== 6.3 How to set up LT-22222-L to work with a Single Channel Gateway, such as LG01/LG02? == 2702 - 2703 - 2615 +== 6.3 How to setup LT-22222-L to work with a Single Channel Gateway, such as LG01/LG02? == 2704 2704 ))) 2705 2705 2706 2706 ((( ... ... @@ -2774,13 +2774,11 @@ 2774 2774 2775 2775 == 6.4 How to change the uplink interval? == 2776 2776 2777 - 2778 2778 Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]] 2779 2779 2780 2780 2781 2781 == 6.5 Can I see the counting event in the serial output? == 2782 2782 2783 - 2784 2784 ((( 2785 2785 You can run the AT command **AT+DEBUG** to view the counting event in the serial output. If the firmware is too old and doesn’t support AT+DEBUG, update to the latest firmware first. 2786 2786 ... ... @@ -2787,7 +2787,6 @@ 2787 2787 2788 2788 == 6.6 Can I use point-to-point communication with LT-22222-L? == 2789 2789 2790 - 2791 2791 Yes, you can. Please refer to the [[Point-to-Point Communication of LT-22222-L>>https://wiki.dragino.com/xwiki/bin/view/Main/%20Point%20to%20Point%20Communication%20of%20LT-22222-L/]] page. The firmware that supports point-to-point communication can be found [[here>>https://github.com/dragino/LT-22222-L/releases]]. 2792 2792 2793 2793 ... ... @@ -2796,15 +2796,13 @@ 2796 2796 ((( 2797 2797 == 6.7 Why does the relay output default to an open relay after the LT-22222-L is powered off? == 2798 2798 2799 - 2800 2800 * If the device is not properly shut down and is directly powered off. 2801 2801 * It will default to a power-off state. 2802 2802 * In modes 2 to 5, the DO/RO status and pulse count are saved to flash memory. 2803 -* After a restart, the status before the power failure will be read from Flash.2711 +* After a restart, the status before the power failure will be read from flash. 2804 2804 2805 -== 6.8 Can I set nNC (Normally Closed) relay? ==2713 +== 6.8 Can I setup LT-22222-L as a NC (Normally Closed) relay? == 2806 2806 2807 - 2808 2808 The LT-22222-L's built-in relay is Normally Open (NO). You can use an external relay to achieve a Normally Closed (NC) configuration. The circuit diagram is shown below: 2809 2809 2810 2810 ... ... @@ -2813,19 +2813,16 @@ 2813 2813 2814 2814 == 6.9 Can the LT-22222-L save the RO state? == 2815 2815 2816 - 2817 2817 To enable this feature, the firmware version must be 1.6.0 or higher. 2818 2818 2819 2819 2820 2820 == 6.10 Why does the LT-22222-L always report 15.585V when measuring the AVI? == 2821 2821 2822 - 2823 2823 It is likely that the GND is not connected during the measurement, or that the wire connected to the GND is loose. 2824 2824 2825 2825 2826 2826 = 7. Troubleshooting = 2827 2827 2828 - 2829 2829 This section provides some known troubleshooting tips. 2830 2830 2831 2831 ... ... @@ -2834,8 +2834,6 @@ 2834 2834 ((( 2835 2835 ((( 2836 2836 == 7.1 Downlink isn't working. How can I solve this? == 2837 - 2838 - 2839 2839 ))) 2840 2840 ))) 2841 2841 ... ... @@ -2847,8 +2847,6 @@ 2847 2847 2848 2848 2849 2849 == 7.2 Having trouble uploading an image? == 2850 - 2851 - 2852 2852 ))) 2853 2853 2854 2854 ((( ... ... @@ -2859,8 +2859,6 @@ 2859 2859 2860 2860 2861 2861 == 7.3 Why can't I join TTN in the US915 /AU915 bands? == 2862 - 2863 - 2864 2864 ))) 2865 2865 2866 2866 ((( ... ... @@ -2870,14 +2870,12 @@ 2870 2870 2871 2871 == 7.4 Why can the LT-22222-L perform uplink normally, but cannot receive downlink? == 2872 2872 2873 - 2874 2874 The FCD count of the gateway is inconsistent with the FCD count of the node, causing the downlink to remain in the queue. 2875 -Use this command to synchronize their counts: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resett ingthedownlinkpacketcount"]]2772 +Use this command to synchronize their counts: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resetsthedownlinkpacketcount"]] 2876 2876 2877 2877 2878 2878 = 8. Ordering information = 2879 2879 2880 - 2881 2881 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 2882 2882 2883 2883 (% style="color:#4f81bd" %)**XXX:** ... ... @@ -2894,7 +2894,6 @@ 2894 2894 2895 2895 = 9. Package information = 2896 2896 2897 - 2898 2898 **Package includes**: 2899 2899 2900 2900 * 1 x LT-22222-L I/O Controller ... ... @@ -2911,7 +2911,6 @@ 2911 2911 2912 2912 = 10. Support = 2913 2913 2914 - 2915 2915 * ((( 2916 2916 Support is available Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different time zones, we cannot offer live support. However, your questions will be answered as soon as possible within the aforementioned schedule. 2917 2917 ))) ... ... @@ -2923,7 +2923,6 @@ 2923 2923 2924 2924 = 11. Reference = 2925 2925 2926 - 2927 2927 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2928 2928 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2929 2929 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
- lt-22222-l-dashboard.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.pradeeka - Size
-
... ... @@ -1,1 +1,0 @@ 1 -352.8 KB - Content