Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
From version 243.11
edited by Xiaoling
on 2025/03/20 15:55
on 2025/03/20 15:55
Change comment:
There is no comment for this version
To version 247.1
edited by Mengting Qiu
on 2025/05/23 16:24
on 2025/05/23 16:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.ting - Content
-
... ... @@ -1511,9 +1511,9 @@ 1511 1511 |(% style="width:113px" %)**Parameters**|(% style="width:384px" %)((( 1512 1512 **RO1_status** : 1 byte in hex 1513 1513 1514 -00: Close1514 +00: Open 1515 1515 1516 -01: Open1516 +01: Close 1517 1517 1518 1518 11: No action 1519 1519 ... ... @@ -1520,9 +1520,9 @@ 1520 1520 1521 1521 **RO2_status** : 1 byte in hex 1522 1522 1523 -00: Close1523 +00: Open 1524 1524 1525 -01: Open1525 +01: Close 1526 1526 1527 1527 11: No action 1528 1528 ))) ... ... @@ -1542,7 +1542,6 @@ 1542 1542 (% style="color:red" %)**The device will transmit an uplink packet if the downlink payload is executed successfully.** 1543 1543 ))) 1544 1544 1545 - 1546 1546 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1547 1547 1548 1548 ... ... @@ -1674,7 +1674,6 @@ 1674 1674 If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1 1675 1675 ))) 1676 1676 1677 - 1678 1678 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1679 1679 1680 1680 ... ... @@ -1725,7 +1725,6 @@ 1725 1725 Sets the COUNT1 to 10. 1726 1726 ))) 1727 1727 1728 - 1729 1729 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1730 1730 1731 1731 ... ... @@ -1751,7 +1751,8 @@ 1751 1751 ==== 3.4.2.19 Counting ~-~- Set Saving Interval for 'Counting Result' ==== 1752 1752 1753 1753 1754 -This command allows you to configure the device to save its counting result to internal flash memory at specified intervals. By setting a save time, the device will periodically store the counting data to prevent loss in case of power failure. The save interval can be adjusted to suit your requirements, with a minimum value of 30 seconds. 1751 +This command configures the device to periodically save the counting results, RO (Relay Output), and DO (Digital Output) states to internal flash memory at a user-defined interval. By setting a save interval, the device ensures that critical data (counting values and output states) is preserved in case of power loss. 1752 +The saved RO/DO states can be restored after a device reset by combining this function with the (% style="color:blue" %)**AT+RODORESET**(%%) command. 1755 1755 1756 1756 (% style="color:#037691" %)**AT Command** 1757 1757