Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 8 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,13 +4,8 @@ 4 4 **LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 -**Table of Contents:** 8 8 9 -{{toc/}} 10 10 11 - 12 - 13 - 14 14 = 1.Introduction = 15 15 16 16 == 1.1 What is LT Series I/O Controller == ... ... @@ -187,9 +187,7 @@ 187 187 188 188 [[image:image-20220523174024-3.png]] 189 189 190 -((( 191 191 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 192 -))) 193 193 194 194 [[image:image-20220523174254-4.png]] 195 195 ... ... @@ -237,230 +237,277 @@ 237 237 238 238 Total : 11 bytes payload 239 239 240 -[[image:image-20220523180452-3.png]] 233 +(% border="1" style="background-color:#f7faff; height:10px; width:500px" %) 234 +|Size(bytes)|4|4|1|1|1 235 +|Value|COUNT1|COUNT2 |DIDORO*|((( 236 +Reserve 241 241 242 -((( 243 -(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 244 -))) 238 + 239 +)))|MOD 245 245 246 - [[image:image-20220523180506-4.png]]241 +**DIDORO** is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 247 247 243 +(% border="1" style="background-color:#f7faff; width:500px" %) 244 +|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 245 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 246 + 248 248 * RO is for relay. ROx=1 : close,ROx=0 always open. 249 249 * FIRST: Indicate this is the first packet after join network. 250 250 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 251 251 252 - (% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L.251 +Note: DO3 bit is not valid for LT-22222-L. 253 253 254 -**To use counting mode, please run:** 255 255 256 -(% class="box infomessage" %) 257 -((( 258 -**AT+MOD=2** 259 -))) 254 +To use counting mode, please run: 260 260 261 -(% class="box infomessage" %) 262 -((( 263 -**ATZ** 264 -))) 256 +AT+MOD=2 265 265 266 - (% style="color:#4f81bd" %)**ATCommands for counting:**258 +ATZ 267 267 260 + 261 +AT Commands for counting: 262 + 263 +**For LT33222-L:** 264 + 265 +AT+TRIG1=0,100 (set DI3 port to trigger on low level, valid signal is 100ms) 266 + 267 +AT+TRIG1=1,100 (set DI3 port to trigger on high level, valid signal is 100ms ) 268 + 269 +AT+SETCNT=1,60 (Set COUNT1 value to 60) 270 + 271 + 268 268 **For LT22222-L:** 269 269 270 -(% class="box infomessage" %) 271 -((( 272 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 273 -))) 274 +AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) 274 274 275 -(% class="box infomessage" %) 276 -((( 277 -**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 278 -))) 276 +AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 279 279 280 -(% class="box infomessage" %) 281 -((( 282 -**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 283 -))) 278 +AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) 284 284 285 -(% class="box infomessage" %) 286 -((( 287 -**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 288 -))) 280 +AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) 289 289 290 -(% class="box infomessage" %) 291 -((( 292 -**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 293 -))) 294 294 295 -(% class="box infomessage" %) 296 -((( 297 -**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 298 -))) 283 +AT+SETCNT=1,60 (Set COUNT1 value to 60) 299 299 300 - === 3.3.3AT+MOD~=3, SingleDI Counting+2xACI===285 +AT+SETCNT=2,60 (Set COUNT2 value to 60) 301 301 287 + 288 +**For both LT22222-L & LT33222-L**: 289 + 290 +AT+CLRCOUNT clear all countings 291 + 292 +AT+COUTIME=60 Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 293 + 294 + 295 + 296 +1. 297 +11. 298 +111. AT+MOD=3, Single DI Counting + 2 x ACI 299 + 300 +**LT33222-L**: This mode the DI3 is used as a counting pin. 301 + 302 302 **LT22222-L**: This mode the DI1 is used as a counting pin. 303 303 304 -[[image:image-20220523181246-5.png]] 305 305 306 -((( 307 -(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 308 -))) 305 +(% border="1" style="background-color:#f7faff" %) 306 +|Size(bytes)|4|2|2|1|1|1 307 +|Value|COUNT1|((( 308 +ACI1 309 309 310 -[[image:image-20220523181301-6.png]] 310 +Current 311 +)))|((( 312 +ACI2 311 311 314 +Current 315 +)))|DIDORO*|Reserve|MOD 316 + 317 +**DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 318 + 319 +(% border="1" style="background-color:#f7faff" %) 320 +|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 321 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 322 + 312 312 * RO is for relay. ROx=1 : close,ROx=0 always open. 313 313 * FIRST: Indicate this is the first packet after join network. 314 314 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 315 315 316 - (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.327 +Note: DO3 is not valid for LT-22222-L. 317 317 318 -**To use counting mode, please run:** 319 319 320 -(% class="box infomessage" %) 321 -((( 322 -**AT+MOD=3** 323 -))) 330 +To use counting mode, please run: 324 324 325 -(% class="box infomessage" %) 326 -((( 327 -**ATZ** 328 -))) 332 +AT+MOD=3 329 329 334 +ATZ 335 + 336 + 330 330 Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:#COUNT_COMMAND]]. 331 331 332 -=== 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 333 333 340 + 341 + 342 +1. 343 +11. 344 +111. AT+MOD=4, Single DI Counting + 1 x Voltage Counting 345 + 346 +**LT33222-L**: This mode the DI3 is used as a counting pin. 347 + 334 334 **LT22222-L**: This mode the DI1 is used as a counting pin. 335 335 350 + 336 336 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. 337 337 338 -[[image:image-20220523181903-8.png]] 339 339 340 -((( 341 -(% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 342 -))) 354 +(% border="1" style="background-color:#f7faff" %) 355 +|Size(bytes)|4|4|1|1|1 356 +|Value|COUNT1|AVI1 Counting|DIDORO*|((( 357 +Reserve 343 343 344 -[[image:image-20220523181727-7.png]] 359 + 360 +)))|MOD 345 345 362 +**DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 363 + 364 +(% border="1" style="background-color:#f7faff" %) 365 +|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 366 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 367 + 346 346 * RO is for relay. ROx=1 : close,ROx=0 always open. 347 347 * FIRST: Indicate this is the first packet after join network. 348 348 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 349 349 350 - (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.372 +Note: DO3 is not valid for LT-22222-L. 351 351 352 -**To use this mode, please run:** 353 353 354 -(% class="box infomessage" %) 355 -((( 356 -**AT+MOD=4** 357 -))) 375 +To use this mode, please run: 358 358 359 -(% class="box infomessage" %) 360 -((( 361 -**ATZ** 362 -))) 377 +AT+MOD=4 363 363 379 +ATZ 364 364 381 + 382 + 365 365 Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:#COUNT_COMMAND]]. 366 366 367 - **Plus below command for AVI1 Counting:**385 +Plus below command for AVI1 Counting: 368 368 369 -(% class="box infomessage" %) 370 -((( 371 -**AT+SETCNT=3,60 (set AVI Count to 60)** 372 -))) 387 +AT+SETCNT=3,60 (set AVI Count to 60) 373 373 374 -(% class="box infomessage" %) 375 -((( 376 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 377 -))) 389 +AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1) 378 378 379 -(% class="box infomessage" %) 380 -((( 381 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 382 -))) 391 +AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1) 383 383 384 -(% class="box infomessage" %) 385 -((( 386 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 387 -))) 393 +AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1) 388 388 389 -=== 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 390 390 396 + 397 +1. 398 +11. 399 +111. AT+MOD=5, Single DI Counting + 2 x AVI + 1 x ACI 400 + 401 +**LT33222-L**: This mode the DI3 is used as a counting pin. 402 + 391 391 **LT22222-L**: This mode the DI1 is used as a counting pin. 392 392 393 -[[image:image-20220523182334-9.png]] 394 394 395 -((( 396 -(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 397 -))) 406 +(% border="1" style="background-color:#f7faff" %) 407 +|Size(bytes)|2|2|2|2|1|1|1 408 +|Value|((( 409 +AVI1 398 398 411 +voltage 412 +)))|((( 413 +AVI2 414 + 415 +voltage 416 +)))|((( 417 +ACI1 418 + 419 +Current 420 +)))|COUNT1|DIDORO*|((( 421 +Reserve 422 + 423 + 424 +)))|MOD 425 + 426 +**DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 427 + 428 +(% border="1" style="background-color:#f7faff" %) 429 +|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 430 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 431 + 399 399 * RO is for relay. ROx=1 : close,ROx=0 always open. 400 400 * FIRST: Indicate this is the first packet after join network. 401 401 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 402 402 403 - (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.436 +Note: DO3 is not valid for LT-22222-L. 404 404 405 -**To use this mode, please run:** 406 406 407 -(% class="box infomessage" %) 408 -((( 409 -**AT+MOD=5** 410 -))) 439 +To use this mode, please run: 411 411 412 -(% class="box infomessage" %) 413 -((( 414 -**ATZ** 415 -))) 441 +AT+MOD=5 416 416 443 +ATZ 444 + 445 + 417 417 Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:#COUNT_COMMAND]]. 418 418 419 -=== 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 420 420 421 -(% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** 422 422 450 + 451 + 452 +1. 453 +11. 454 +111. AT+ADDMOD=6. (Trigger Mode, Optional) 455 + 456 +**This mode is an optional mode for trigger purpose. It can run together with other mode.** 457 + 423 423 For example, if user has configured below commands: 424 424 425 -* **AT+MOD=1****~-~->**The normal working mode426 -* **AT+ADDMOD6=1****~-~->**Enable trigger460 +* AT+MOD=1 à The normal working mode 461 +* AT+ADDMOD6=1 à Enable trigger 427 427 428 428 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 429 429 430 -1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%)data type431 -1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**465 +1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN **unconfirmed** data type 466 +1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN **CONFIRMED data type.** 432 432 433 433 **AT Command to set Trigger Condition**: 434 434 435 - (% style="color:#4f81bd" %)**Trigger base on voltage**:470 +**Trigger base on voltage**: 436 436 437 437 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> 438 438 439 - **Example:**474 +Example: 440 440 441 441 AT+AVLIM=3000,6000,0,2000 (If AVI1 voltage lower than 3v or higher than 6v. or AV2 voltage is higher than 2v, LT will trigger Uplink) 442 442 443 443 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 444 444 445 -(% style="color:#4f81bd" %)**Trigger base on current**: 446 446 481 +**Trigger base on current**: 482 + 447 447 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> 448 448 449 - **Example:**485 +Example: 450 450 451 451 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 452 452 453 -(% style="color:#4f81bd" %)**Trigger base on DI status**: 454 454 490 +**Trigger base on DI status**: 491 + 455 455 DI status trigger Flag. 456 456 457 457 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 458 458 459 - **Example:**496 +Example: 460 460 461 461 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 462 462 463 463 501 + 502 + 503 + 464 464 **Downlink Command to set Trigger Condition** 465 465 466 466 Type Code: 0xAA. Downlink command same as AT Command [[AT+AVLIM, AT+ACLIM>>path:#AT_Trigger]] ... ... @@ -479,8 +479,9 @@ 479 479 480 480 Yy4 yy4: AC2 or AV2 high limit. 481 481 482 -**Example1**: AA 00 13 88 00 00 00 00 00 00 483 483 523 +Example1: AA 00 13 88 00 00 00 00 00 00 524 + 484 484 Same as AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 485 485 486 486 Example2: AA 02 01 00 ... ... @@ -487,14 +487,35 @@ 487 487 488 488 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 489 489 490 -(% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 491 491 532 + 533 + 534 +**Trigger Settings Payload Explanation:** 535 + 492 492 MOD6 Payload : total 11 bytes payload 493 493 494 -[[image:image-20220524085923-1.png]] 538 +(% border="1" style="background-color:#f7faff" %) 539 +|Size(bytes)|1|1|1|6|1|1 540 +|Value|((( 541 +TRI_A 495 495 496 -(% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 543 +FLAG 544 +)))|((( 545 +TRI_A 497 497 547 +Status 548 +)))|((( 549 +TRI_DI 550 + 551 +FLAG+STA 552 +)))|Reserve|Enable/Disable MOD6|((( 553 +MOD 554 + 555 +(6) 556 +))) 557 + 558 +**TRI FLAG1** is a combination to show if trigger is set for this part. Totally 1byte as below 559 + 498 498 (% border="1" style="background-color:#f7faff" %) 499 499 |bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 500 500 |((( ... ... @@ -538,7 +538,7 @@ 538 538 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW 539 539 540 540 541 - (% style="color:#4f81bd" %)**TRI Status1**(%%)is a combination to show which condition is trigger. Totally 1byte as below603 +**TRI Status1** is a combination to show which condition is trigger. Totally 1byte as below 542 542 543 543 (% border="1" style="background-color:#f7faff" %) 544 544 |bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 ... ... @@ -585,7 +585,7 @@ 585 585 586 586 587 587 588 - (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below650 +**TRI_DI FLAG+STA **is a combination to show which condition is trigger. Totally 1byte as below 589 589 590 590 (% border="1" style="background-color:#f7faff" %) 591 591 |bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 ... ... @@ -600,7 +600,7 @@ 600 600 00000101: Means both DI1 and DI2 trigger are enabled. 601 601 602 602 603 - (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable.665 +**Enable/Disable MOD6 **: 0x01: MOD6 is enable. 0x00: MOD6 is disable. 604 604 605 605 606 606 Downlink command to poll MOD6 status: ... ... @@ -610,8 +610,8 @@ 610 610 When device got this command, it will send the MOD6 payload. 611 611 612 612 613 -1. 614 -11. 675 +1. 676 +11. 615 615 111. Payload Decoder 616 616 617 617 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] ... ... @@ -622,7 +622,7 @@ 622 622 623 623 624 624 625 -1. 687 +1. 626 626 11. Configure LT via AT or Downlink 627 627 628 628 User can configure LT I/O Controller via [[AT Commands >>path:#_Using_the_AT]]or LoRaWAN Downlink Commands ... ... @@ -633,15 +633,15 @@ 633 633 634 634 * **Sensor Related Commands**: These commands are special designed for LT-22222-L. User can see these commands below: 635 635 636 -1. 637 -11. 698 +1. 699 +11. 638 638 111. Common Commands: 639 639 640 640 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands 641 641 642 642 643 -1. 644 -11. 705 +1. 706 +11. 645 645 111. Sensor related commands: 646 646 647 647 ==== Set Transmit Interval ==== ... ... @@ -1100,7 +1100,7 @@ 1100 1100 1101 1101 1102 1102 1103 -1. 1165 +1. 1104 1104 11. Integrate with Mydevice 1105 1105 1106 1106 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1158,7 +1158,7 @@ 1158 1158 1159 1159 1160 1160 1. 1161 -11. 1223 +11. 1162 1162 111. Digital Input Port: DI1/DI2 ( For LT-22222-L) 1163 1163 1164 1164 The DI port of LT-22222-L can support NPN or PNP output sensor. ... ... @@ -1212,8 +1212,8 @@ 1212 1212 If sensor output is 220v, the //IF//[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]] = 4.3mA , So the LT-22222-L will be able to detect this high active signal safely. 1213 1213 1214 1214 1215 -1. 1216 -11. 1277 +1. 1278 +11. 1217 1217 111. Digital Output Port: DO1/DO2 /DO3 1218 1218 1219 1219 NPN output: GND or Float. Max voltage can apply to output pin is 36v. ... ... @@ -1224,7 +1224,7 @@ 1224 1224 1225 1225 1226 1226 1. 1227 -11. 1289 +11. 1228 1228 111. Analog Input Interface 1229 1229 1230 1230 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: ... ... @@ -1257,7 +1257,7 @@ 1257 1257 1258 1258 1259 1259 1. 1260 -11. 1322 +11. 1261 1261 111. Relay Output 1262 1262 1263 1263 The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below: ... ... @@ -1308,6 +1308,7 @@ 1308 1308 |**RO1**| 1309 1309 |**RO2**| 1310 1310 1373 + 1311 1311 1. Use AT Command 1312 1312 11. Access AT Command 1313 1313 ... ... @@ -1417,7 +1417,7 @@ 1417 1417 1418 1418 1419 1419 1420 -1. 1483 +1. 1421 1421 11. Common AT Command Sequence 1422 1422 111. Multi-channel ABP mode (Use with SX1301/LG308) 1423 1423 ... ... @@ -1440,8 +1440,8 @@ 1440 1440 1441 1441 ATZ 1442 1442 1443 -1. 1444 -11. 1506 +1. 1507 +11. 1445 1445 111. Single-channel ABP mode (Use with LG01/LG02) 1446 1446 1447 1447 123456 Enter Password to have AT access. ... ... @@ -1481,7 +1481,7 @@ 1481 1481 1482 1482 1483 1483 1. 1484 -11. 1547 +11. 1485 1485 111. Change to Class A 1486 1486 1487 1487 If sensor JOINED ... ... @@ -1496,7 +1496,7 @@ 1496 1496 1497 1497 1. FAQ 1498 1498 1499 -1. 1562 +1. 1500 1500 11. How to upgrade the image? 1501 1501 1502 1502 The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to: ... ... @@ -1555,7 +1555,7 @@ 1555 1555 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. 1556 1556 1557 1557 1558 -1. 1621 +1. 1559 1559 11. How to set up LT to work with Single Channel Gateway such as LG01/LG02? 1560 1560 1561 1561 In this case, users need to set LT-33222-L to work in ABP mode & transmit in only one frequency. ... ... @@ -1614,7 +1614,7 @@ 1614 1614 [[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#How_it_work>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#How_it_work]] 1615 1615 1616 1616 1617 -1. 1680 +1. 1618 1618 11. Have trouble to upload image. 1619 1619 1620 1620 See this link for trouble shooting: ... ... @@ -1622,7 +1622,7 @@ 1622 1622 [[http:~~/~~/wiki.dragino.com/index.php?title=Firmware_Upgrade_Trouble_Shooting#UART_upgrade_trouble_shooting>>url:http://wiki.dragino.com/index.php?title=Firmware_Upgrade_Trouble_Shooting#UART_upgrade_trouble_shooting]] 1623 1623 1624 1624 1625 -1. 1688 +1. 1626 1626 11. Why I can’t join TTN in US915 /AU915 bands? 1627 1627 1628 1628 It might be about the channels mapping. Please see this link for detail:
- image-20220523180452-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -4.5 KB - Content
- image-20220523180506-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -4.5 KB - Content
- image-20220523181246-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -5.5 KB - Content
- image-20220523181301-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -4.6 KB - Content
- image-20220523181727-7.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -4.8 KB - Content
- image-20220523181903-8.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -4.9 KB - Content
- image-20220523182334-9.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.4 KB - Content
- image-20220524085923-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.4 KB - Content