Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. pradeeka1 +XWiki.Xiaoling - Content
-
... ... @@ -128,8 +128,8 @@ 128 128 (% style="text-align:center" %) 129 129 [[image:lt33222-l.jpg||height="110" width="95"]] 130 130 )))|(% style="width:256px" %)((( 131 -* 2x Digital Input (Bi-direction)132 -* 2x Digital Output131 +* 3 x Digital Input (Bi-direction) 132 +* 3 x Digital Output 133 133 * 2 x Relay Output (5A@250VAC / 30VDC) 134 134 * 2 x 0~~20mA Analog Input (res:0.01mA) 135 135 * 2 x 0~~30V Analog Input (res:0.01v) ... ... @@ -261,12 +261,18 @@ 261 261 ** Enter the **AppEUI** in the **JoinEUI** field and click the **Confirm** button. If The Things Stack accepts the JoinEUI you provided, it will display the message 'This end device can be registered on the network'. 262 262 ** In the **DevEUI** field, enter the **DevEUI**. 263 263 ** In the **AppKey** field, enter the **AppKey.** 264 -** In the **End device ID** field, enter a unique name for your LT-22222- Nwithin this application.264 +** In the **End device ID** field, enter a unique name for your LT-22222-L within this application. 265 265 ** Under **After registration**, select the **View registered end device** option. 266 +** Click **Register end device** button. 266 266 267 267 [[image:lt-22222-l-dev-repo-reg-p2.png]] 268 268 269 269 271 +* You will be navigated to the **Device overview** page. 272 + 273 +[[image:lt-22222-device-overview.png]] 274 + 275 + 270 270 ==== 3.2.1.2 Adding device manually ==== 271 271 272 272 ... ... @@ -368,11 +368,8 @@ 368 368 This is the default mode. 369 369 370 370 The uplink payload is 11 bytes long. 377 +(% style="display:none" wfd-invisible="true" %) 371 371 372 -(% style="color:red" %)**Note:The maximum count depends on the bytes number of bytes. 373 -The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 374 -It starts counting again when it reaches the maximum value.**(% style="display:none" wfd-invisible="true" %) 375 - 376 376 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 377 377 |(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** 378 378 |Value|((( ... ... @@ -641,7 +641,7 @@ 641 641 642 642 643 643 (% style="color:red" %)**Note:The maximum count depends on the bytes it is. 644 -The maximum count for four bytes is FFFF FFFF(hex) =4294967295 (dec).647 +The maximum count for four bytes is FFFF (hex) = 65535 (dec). 645 645 It starts counting again when it reaches the maximum value.** 646 646 647 647 ... ... @@ -1157,7 +1157,7 @@ 1157 1157 Enable DI1 trigger, disable DI2 trigger 1158 1158 ))) 1159 1159 1160 -==== 3.4.2.7 Trigger1 – Set DI or DI3 as a trigger ==== 1163 +==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as a trigger ==== 1161 1161 1162 1162 1163 1163 Sets DI1 or DI3 (for LT-33222-L) as a trigger. ... ... @@ -1531,7 +1531,7 @@ 1531 1531 |03 00 11|Open|No action 1532 1532 |03 01 11|Close|No action 1533 1533 |03 11 00|No action|Open 1534 -|03 11 10|No action|Close1537 +|03 11 01|No action|Close 1535 1535 |03 00 00|Open|Open 1536 1536 |03 01 01|Close|Close 1537 1537 |03 01 00|Close|Open ... ... @@ -2140,7 +2140,7 @@ 2140 2140 ==== 3.5.2.4 Viewing sensor data on a dashboard ==== 2141 2141 2142 2142 2143 -You can create a dashboard with ThingsEye to visualize the sensor data coming from the L HT65N-VIB. The following image shows a dashboard created for the LT-22222-L. See **Creating a dashboard** in ThingsEye documentation for more information.2146 +You can create a dashboard with ThingsEye to visualize the sensor data coming from the LT-22222-L. The following image shows a dashboard created for the LT-22222-L. See **Creating a dashboard** in ThingsEye documentation for more information. 2144 2144 2145 2145 2146 2146 ... ... @@ -2592,8 +2592,7 @@ 2592 2592 2593 2593 **2. Verify that the LG01/02 gateway RX frequency matches the AT+CHS setting exactly.** 2594 2594 2595 -**3. Make sure the SF/bandwidth settings in the LG01/LG02 match the settings of AT+DR. Refer to [[this link>>url:http://www.dragino.com/downloads/index.php? 2596 -dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 2598 +**3. Make sure the SF/bandwidth settings in the LG01/LG02 match the settings of AT+DR. Refer to [[this link>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 2597 2597 2598 2598 **4. The commands AT+RX2FQ and AT+RX2DR enable downlink functionality. To set the correct parameters, you can check the actual downlink parameters to be used as shown below. Here, RX2FQ should be set to 868400000 and RX2DR should be set to 5.** 2599 2599 ))) ... ... @@ -2690,7 +2690,7 @@ 2690 2690 ))) 2691 2691 2692 2692 ((( 2693 -You can follow the introductions on [[how to upgrade the image>>||anchor="H 5.1Howtoupgradetheimage3F"]]. When downloading, select the required image file.2695 +You can follow the introductions on [[how to upgrade the image>>||anchor="H6.1Howtoupdatethefirmware3F"]]. When downloading, select the required image file. 2694 2694 ))) 2695 2695 2696 2696 ((( ... ... @@ -2870,7 +2870,7 @@ 2870 2870 2871 2871 2872 2872 The FCD count of the gateway is inconsistent with the FCD count of the node, causing the downlink to remain in the queue. 2873 -Use this command to synchronize their counts: [[Resets the downlink packet count>>||anchor="H3.4.2.23Reset sthedownlinkpacketcount"]]2875 +Use this command to synchronize their counts: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resettingthedownlinkpacketcount"]] 2874 2874 2875 2875 2876 2876 = 8. Ordering information =