... ... @@ -241,6 +241,7 @@
241 241  * Go to your application's page and click on the **End devices** in the left menu.
242 242  * On the End devices page, click on **+ Register end device**. Two registration options are available:
243 243  
244 +
244 244  ==== 3.2.1.1 Using the LoRaWAN Device Repository ====
245 245  
246 246  
... ... @@ -1494,51 +1494,40 @@
1494 1494  DO1 pin takes no action, DO2 pin is set to low, and DO3 pin is set to high. This lasts for 2 seconds, after which DO1 pin takes no action, DO2 pin is set to high, and DO3 pin is set to low.
1495 1495  )))
1496 1496  
1498 +
1497 1497  ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1498 1498  
1499 1499  
1500 -(% style="color:#037691" %)**AT Command:**
1502 +* (% style="color:#037691" %)**AT Command:**
1501 1501  
1502 -There is no AT Command to control the Relay Output.
1504 +There is no AT Command to control the Relay Output
1503 1503  
1504 1504  
1505 -(% style="color:#037691" %)**Downlink Payload**
1507 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):**
1506 1506  
1507 -(% border="2" style="width:500px" %)
1508 -|(% style="width:113px" %)**Prefix**|(% style="width:384px" %)0x03
1509 -|(% style="width:113px" %)**Parameters**|(% style="width:384px" %)(((
1510 -**RO1_status** : 1 byte in hex
1509 +(% style="color:blue" %)**0x03 aa bb     ** (%%)~/~/ Sets RO1/RO2 output
1511 1511  
1512 -00: Close
1513 1513  
1514 -01: Open
1512 +(((
1513 +If the payload is 0x030100, it means setting RO1 to close and RO2 to open.
1514 +)))
1515 1515  
1516 -11: No action
1516 +(((
1517 +00: Close ,  01: Open , 11: No action
1517 1517  
1518 -
1519 -**RO2_status** : 1 byte in hex
1520 -
1521 -00: Close
1522 -
1523 -01: Open
1524 -
1525 -11: No action
1519 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:320px" %)
1520 +|(% style="background-color:#4f81bd; color:white" %)**Downlink Code**|(% style="background-color:#4f81bd; color:white" %)**RO1**|(% style="background-color:#4f81bd; color:white" %)**RO2**
1521 +|03  00  11|Open|No Action
1522 +|03  01  11|Close|No Action
1523 +|03  11  00|No Action|Open
1524 +|03  11  01|No Action|Close
1525 +|03  00  00|Open|Open
1526 +|03  01  01|Close|Close
1527 +|03  01  00|Close|Open
1528 +|03  00  01|Open|Close
1526 1526  )))
1527 -|(% style="width:113px" %)**Payload format**|(% style="width:384px" %)<prefix><RO1_status><RO2_status>
1528 -|(% style="width:113px" %)**Example**|(% style="width:384px" %)(((
1529 -(% border="2" %)
1530 -|=Payload|=RO1|=RO2
1531 -|03  00  11|Open|No action
1532 -|03  01  11|Close|No action
1533 -|03 11  00|No action|Open
1534 -|03 11 10|No action|Close
1535 -|03 00 00|Open|Open
1536 -|03 01 01|Close|Close
1537 -|03 01 00|Close|Open
1538 -|03 00 01|Open|Close
1539 1539  
1540 -(% style="color:red" %)**The device will transmit an uplink packet if the downlink payload is executed successfully.**
1541 -)))
1531 +(% style="color:red" %)**The device will uplink a packet if the downlink code executes successfully.**
1542 1542  
1543 1543  
1544 1544  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
... ... @@ -1546,13 +1546,12 @@
1546 1546  
1547 1547  Controls the relay output time.
1548 1548  
1539 +* (% style="color:#037691" %)**AT Command:**
1549 1549  
1550 -(% style="color:#037691" %)**AT Command:**
1551 -
1552 1552  There is no AT Command to control the Relay Output
1553 1553  
1554 1554  
1555 -(% style="color:#037691" %)**Downlink Payload (prefix 0x05):**
1544 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):**
1556 1556  
1557 1557  (% style="color:blue" %)**0x05 aa bb cc dd     ** (%%)~/~/ Sets RO1/RO2 relays with time control
1558 1558  
... ... @@ -2127,7 +2127,7 @@
2127 2127  [[image:thingseye-events.png]]
2128 2128  
2129 2129  
2130 -* To view the **JSON payload** of a message, click on the **three dots (...)** in the **Message** column of the desired message.
2119 +* To view the **JSON payload** of a message, click on the **three dots (...)** in the Message column of the desired message.
2131 2131  
2132 2132  [[image:thingseye-json.png]]
2133 2133  
... ... @@ -2138,16 +2138,12 @@
2138 2138  If you want to delete an integration, click the **Delete integratio**n button on the Integrations page.
2139 2139  
2140 2140  
2141 -==== 3.5.2.4 Viewing sensor data on a dashboard ====
2130 +==== 3.5.2.4 Creating a Dashboard to Display and Analyze LT-22222-L Data ====
2142 2142  
2143 2143  
2144 -You can create a dashboard with ThingsEye to visualize the sensor data coming from the LHT65N-VIB. The following image shows a dashboard created for the LT-22222-L. See **Creating a dashboard** in ThingsEye documentation for more information.
2133 +This will be added soon.
2145 2145  
2146 2146  
2147 -
2148 -[[image:lt-22222-l-dashboard.png]]
2149 -
2150 -
2151 2151  == 3.6 Interface Details ==
2152 2152  
2153 2153  === 3.6.1 Digital Input Ports: DI1/DI2/DI3 (For LT-33222-L, Low Active) ===
lt-22222-l-dashboard.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.pradeeka
Size
... ... @@ -1,1 +1,0 @@
1 -352.8 KB
Content