Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -124,7 +124,7 @@ 124 124 125 125 (% border="1" cellspacing="3" style="width:510px" %) 126 126 |(% style="background-color:#4f81bd; color:white; width:94px" %)**Model**|(% style="background-color:#4f81bd; color:white; width:172px" %)**Photo**|(% style="background-color:#4f81bd; color:white; width:244px" %)**Description** 127 -|(% style="width:94px" %)**LT-222 22-L**|(% style="width:172px" %)(((127 +|(% style="width:94px" %)**LT-33222-L**|(% style="width:172px" %)((( 128 128 (% style="text-align:center" %) 129 129 [[image:lt33222-l.jpg||height="110" width="95"]] 130 130 )))|(% style="width:256px" %)((( ... ... @@ -151,7 +151,7 @@ 151 151 == 2.2 Terminals == 152 152 153 153 154 -The LT-22222-L has two screw terminal blocks. The upper screw t reminal block has 6 screw terminals and the lower screw terminal block has 10 screw terminals.154 +The LT-22222-L has two screw terminal blocks. The upper screw terminal block has 6 screw terminals and the lower screw terminal block has 10 screw terminals. 155 155 156 156 **Upper screw terminal block (from left to right):** 157 157 ... ... @@ -201,7 +201,7 @@ 201 201 == 3.1 Prerequisites == 202 202 203 203 204 -The LT-22222-L comes with device registration information such as DevEUI, AppEUI, and AppKey thatallows you to register it with a LoRaWAN network. Theseregistration information can be found on a sticker that can be found inside the package. Please keep the **registration information** sticker in a safe place for future reference.204 +The LT-22222-L comes with device registration information such as DevEUI, AppEUI, and AppKey which allows you to register it with a LoRaWAN network. This registration information can be found on a sticker that can be found inside the package. Please keep the **registration information** sticker in a safe place for future reference. 205 205 206 206 [[image:image-20230425173427-2.png||height="246" width="530"]] 207 207 ... ... @@ -302,7 +302,7 @@ 302 302 === 3.2.2 Joining === 303 303 304 304 305 -On the Device's page, click on **Live data** tab. The Live data panel for your device will display.305 +On the end device's page (in this case, lt-22222-l), click on **Live data** tab. The Live data panel for your device will display. Initially, it is blank. 306 306 307 307 Now power on your LT-22222-L. The **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** The Things Stack network server. The **TX LED** will be on for **5 seconds** after joining the network. In the **Live data** panel, you can see the **join-request** and **join-accept** messages exchanged between the device and the network server. 308 308 ... ... @@ -313,14 +313,14 @@ 313 313 === 3.2.3 Uplinks === 314 314 315 315 316 -After successfully joining, the device will send its first **uplink data message** to the application it belongs to (in this example, **dragino-docs**). When the LT-22222-L sends an uplink message to the server, the **TX LED** turns on for **1 second**. By default, you will receive an uplink data message from the device every 10 minutes.316 +After successfully joining, the device will send its first **uplink data message** to The Things Stack application it belongs to (in this example, it is **dragino-docs**). When the LT-22222-L sends an uplink message to the server, the **TX LED** turns on for **1 second**. By default, you will receive an uplink data message from the device every 10 minutes. 317 317 318 -Click on one of a**Forward uplink data messages **to see its payload content. The payload content is encapsulated within the decode_payload {} JSON object.318 +Click on one of the **Forward uplink data messages **to see its payload content. The payload content is encapsulated within the **decode_payload {}** JSON object. 319 319 320 320 [[image:lt-22222-ul-payload-decoded.png]] 321 321 322 322 323 -If you can't see the decoded payload, it is because you haven't added the uplink formatter code. To add the uplink formatter code, select **Applications > your application > End devices** > **your end device** > **Payload formatters** > **Uplink**. Then 323 +If you can't see the decoded payload, it is because you haven't added the uplink formatter code. To add the uplink formatter code, select **Applications > [your application] > End devices** > [**your end device]** > **Payload formatters** > **Uplink**. Then select **Use Device repository formatters** for the **Formatter type** dropdown. Click the **Save changes** button to apply the changes. 324 324 325 325 {{info}} 326 326 The Things Stack provides two levels of payload formatters: application level and device level. The device-level payload formatters **override **the application-level payload formatters. ... ... @@ -329,7 +329,7 @@ 329 329 [[image:lt-22222-ul-payload-fmt.png]] 330 330 331 331 332 -We alsohave a payload formatter that resolves some decoding issues present inthe Device Repository formatter. You can add it under the Custom JavaScript formatter. It can be found [[here>>https://github.com/dragino/dragino-end-node-decoder/blob/main/LT22222-L/v1.6_decoder_ttn%20.txt]]:332 +We have written a payload formatter that resolves some decoding issues present in The Things Stack Device Repository payload formatter. You can add it under the **Custom JavaScript formatter**. It can be found [[here>>https://github.com/dragino/dragino-end-node-decoder/blob/main/LT22222-L/v1.6_decoder_ttn%20.txt]]: 333 333 334 334 (% class="wikigeneratedid" %) 335 335 [[image:lt-22222-l-js-custom-payload-formatter.png]] ... ... @@ -338,7 +338,7 @@ 338 338 === 3.2.4 Downlinks === 339 339 340 340 341 -When the LT-22222-L receives a downlink message from the server, the **RX LED** turns on for **1 second**.341 +When the LT-22222-L receives a downlink message from the LoRaWAN Network Server, the **RX LED** turns on for **1 second**. 342 342 343 343 344 344 == 3.3 Working Modes and Uplink Payload formats == ... ... @@ -726,7 +726,7 @@ 726 726 727 727 AT+AVLIM=3000,6000,0,2000 (triggers an uplink if AVI1 voltage is lower than 3V or higher than 6V, or if AV2 voltage is higher than 2V) 728 728 729 -AT+AVLIM=5000,0,0,0 (triggers an uplink if AVI1 voltage lower than 5V. Use 0 for parameters that are not in use) 729 +AT+AVLIM=5000,0,0,0 (triggers an uplink if AVI1 voltage is lower than 5V. Use 0 for parameters that are not in use) 730 730 731 731 732 732 (% style="color:#4f81bd" %)**Trigger based on current**: ... ... @@ -782,7 +782,7 @@ 782 782 783 783 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 784 784 785 -MOD6 Payload: total of 11 bytes 785 +MOD6 Payload: a total of 11 bytes 786 786 787 787 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:515px" %) 788 788 |(% style="background-color:#4f81bd; color:white; width:60px" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white; width:69px" %)**1**|(% style="background-color:#4f81bd; color:white; width:69px" %)**1**|(% style="background-color:#4f81bd; color:white; width:109px" %)**1**|(% style="background-color:#4f81bd; color:white; width:49px" %)**6**|(% style="background-color:#4f81bd; color:white; width:109px" %)**1**|(% style="background-color:#4f81bd; color:white; width:50px" %)**1** ... ... @@ -796,7 +796,7 @@ 796 796 MOD(6) 797 797 ))) 798 798 799 -(% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if the trigger is set for this part. Total ly1 byte as below799 +(% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if the trigger is set for this part. Total 1 byte as below. 800 800 801 801 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:515px" %) 802 802 |**bit 7**|**bit 6**|**bit 5**|**bit 4**|**bit 3**|**bit 2**|**bit 1**|**bit 0** ... ... @@ -825,7 +825,7 @@ 825 825 10100000: This means the system is configured to use the triggers AV1_LOW and AV2_LOW. 826 826 827 827 828 -(% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Total ly1 byte as below828 +(% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is triggered. Total 1 byte as below. 829 829 830 830 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:515px" %) 831 831 |**bit 7**|**bit 6**|**bit 5**|**bit 4**|**bit 3**|**bit 2**|**bit 1**|**bit 0** ... ... @@ -854,7 +854,7 @@ 854 854 10000000: The uplink is triggered by AV1_LOW, indicating that the voltage is too low. 855 855 856 856 857 -(% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Total ly1byte as below857 +(% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is triggered. Total 1 byte as below. 858 858 859 859 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:515px" %) 860 860 |(% style="width:50px" %)**bit 7**|(% style="width:50px" %)**bit 6**|(% style="width:50px" %)**bit 5**|(% style="width:50px" %)**bit 4**|(% style="width:90px" %)**bit 3**|(% style="width:80px" %)**bit 2**|(% style="width:90px" %)**bit 1**|(% style="width:95px" %)**bit 0** ... ... @@ -864,7 +864,7 @@ 864 864 865 865 **Example:** 866 866 867 -00000111: This means both DI1 and DI2 triggers are enabled, and this packet is trigger by DI1. 867 +00000111: This means both DI1 and DI2 triggers are enabled, and this packet is triggered by DI1. 868 868 869 869 00000101: This means both DI1 and DI2 triggers are enabled. 870 870 ... ... @@ -875,7 +875,7 @@ 875 875 876 876 **AB 06** 877 877 878 -When device receives this command, it will send the MOD6 payload. 878 +When the device receives this command, it will send the MOD6 payload. 879 879 880 880 881 881 === 3.3.7 Payload Decoder === ... ... @@ -896,7 +896,7 @@ 896 896 897 897 ((( 898 898 ((( 899 -There are two ty tes of commands:899 +There are two types of commands: 900 900 ))) 901 901 ))) 902 902 ... ... @@ -908,7 +908,7 @@ 908 908 909 909 910 910 ((( 911 -These are available for each sensor sand include actions such as changing the uplink interval or resetting the device. For firmware v1.5.4, you can find the supported common commands under: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]s.911 +These are available for each sensor and include actions such as changing the uplink interval or resetting the device. For firmware v1.5.4, you can find the supported common commands under: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]s. 912 912 913 913 914 914 ))) ... ... @@ -1099,7 +1099,7 @@ 1099 1099 |(% style="width:95px" %)**Example**|(% style="width:403px" %)((( 1100 1100 AB 06 1101 1101 1102 -Uplink sthe trigger settings.1102 +Uplink the trigger settings. 1103 1103 ))) 1104 1104 1105 1105 ==== 3.4.2.6 Enable/Disable DI1/DI2/DI3 as a trigger ==== ... ... @@ -1328,7 +1328,7 @@ 1328 1328 ))) 1329 1329 |(% style="width:104px" %)**Note**|(% style="width:394px" %)See also, [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1330 1330 1331 -==== 3.4.2.11 Trigger – Set minimum interval ==== 1331 +==== 3.4.2.11 Trigger – Set the minimum interval ==== 1332 1332 1333 1333 1334 1334 Sets the AV and AC trigger minimum interval. The device won't respond to a second trigger within this set time after the first trigger. ... ... @@ -1466,7 +1466,7 @@ 1466 1466 1467 1467 (% style="color:red" %)**Note: ** 1468 1468 1469 - Since firmware v1.6.0, the latch time support 4 bytes or 2 bytes 1469 + Since firmware v1.6.0, the latch time supports 4 bytes or 2 bytes 1470 1470 1471 1471 Before firmware v1.6.0, the latch time only supported 2 bytes. 1472 1472 ... ... @@ -1491,55 +1491,67 @@ 1491 1491 1492 1492 **A9 00 11 01 00 07 D0** 1493 1493 1494 -DO1 pin takes no action, DO2 pin is set to low, and DO3 pin is set to high. This lasts for 2 seconds, after which DO1 pin takes no action, DO2 pin is set to high, and DO3 pin is set to low. 1494 +DO1 pin takes no action, DO2 pin is set to low, and DO3 pin is set to high. This lasts for 2 seconds, after which the DO1 pin takes no action, the DO2 pin is set to high, and the DO3 pin is set to low. 1495 1495 ))) 1496 1496 1497 1497 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1498 1498 1499 1499 1500 - *(% style="color:#037691" %)**AT Command:**1500 +(% style="color:#037691" %)**AT Command:** 1501 1501 1502 -There is no AT Command to control the Relay Output 1502 +There is no AT Command to control the Relay Output. 1503 1503 1504 1504 1505 - *(% style="color:#037691" %)**Downlink Payload(prefix 0x03):**1505 +(% style="color:#037691" %)**Downlink Payload** 1506 1506 1507 -(% style="color:blue" %)**0x03 aa bb ** (%%)~/~/ Sets RO1/RO2 output 1507 +(% border="2" style="width:500px" %) 1508 +|(% style="width:113px" %)**Prefix**|(% style="width:384px" %)0x03 1509 +|(% style="width:113px" %)**Parameters**|(% style="width:384px" %)((( 1510 +**RO1_status** : 1 byte in hex 1508 1508 1512 +00: Close 1509 1509 1510 -((( 1511 -If the payload is 0x030100, it means setting RO1 to close and RO2 to open. 1512 -))) 1514 +01: Open 1513 1513 1514 -((( 1515 -00: Close , 01: Open , 11: No action 1516 +11: No action 1516 1516 1517 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:320px" %) 1518 -|(% style="background-color:#4f81bd; color:white" %)**Downlink Code**|(% style="background-color:#4f81bd; color:white" %)**RO1**|(% style="background-color:#4f81bd; color:white" %)**RO2** 1519 -|03 00 11|Open|No Action 1520 -|03 01 11|Close|No Action 1521 -|03 11 00|No Action|Open 1522 -|03 11 01|No Action|Close 1523 -|03 00 00|Open|Open 1524 -|03 01 01|Close|Close 1525 -|03 01 00|Close|Open 1526 -|03 00 01|Open|Close 1527 -))) 1528 1528 1529 - (%style="color:red" %)**Thedevicewilluplink a packetif thedownlinkcodeexecutes successfully.**1519 +**RO2_status** : 1 byte in hex 1530 1530 1521 +00: Close 1531 1531 1523 +01: Open 1524 + 1525 +11: No action 1526 +))) 1527 +|(% style="width:113px" %)**Payload format**|(% style="width:384px" %)<prefix><RO1_status><RO2_status> 1528 +|(% style="width:113px" %)**Example**|(% style="width:384px" %)((( 1529 +(% border="2" %) 1530 +|=Payload|=RO1|=RO2 1531 +|03 00 11|Open|No action 1532 +|03 01 11|Close|No action 1533 +|03 11 00|No action|Open 1534 +|03 11 10|No action|Close 1535 +|03 00 00|Open|Open 1536 +|03 01 01|Close|Close 1537 +|03 01 00|Close|Open 1538 +|03 00 01|Open|Close 1539 + 1540 +(% style="color:red" %)**The device will transmit an uplink packet if the downlink payload is executed successfully.** 1541 +))) 1542 + 1532 1532 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1533 1533 1534 1534 1535 1535 Controls the relay output time. 1536 1536 1537 -* (% style="color:#037691" %)**AT Command:** 1538 1538 1549 +(% style="color:#037691" %)**AT Command:** 1550 + 1539 1539 There is no AT Command to control the Relay Output 1540 1540 1541 1541 1542 - *(% style="color:#037691" %)**Downlink Payload (prefix 0x05):**1554 +(% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1543 1543 1544 1544 (% style="color:blue" %)**0x05 aa bb cc dd ** (%%)~/~/ Sets RO1/RO2 relays with time control 1545 1545 ... ... @@ -1550,9 +1550,9 @@ 1550 1550 1551 1551 (% style="color:#4f81bd" %)**Second byte (aa)**(%%): Inverter Mode 1552 1552 1553 -01: Relays will change back to their original state after timeout. 1565 +01: Relays will change back to their original state after a timeout. 1554 1554 1555 -00: Relays will change to the inverter state after timeout. 1567 +00: Relays will change to the inverter state after a timeout. 1556 1556 1557 1557 1558 1558 (% style="color:#4f81bd" %)**Third byte (bb)**(%%): Control Method and Ports status: ... ... @@ -1581,7 +1581,7 @@ 1581 1581 1582 1582 **2. 05 01 10 07 D0** 1583 1583 1584 -Relay1 will change to NC, Relay2 will change to NO, lasting 2 seconds, then both will revert to their original state. 1596 +Relay1 will change to NC, Relay2 will change to NO, lasting 2 seconds, and then both will revert to their original state. 1585 1585 1586 1586 **3. 05 00 01 07 D0** 1587 1587 ... ... @@ -1612,7 +1612,7 @@ 1612 1612 1613 1613 **1**: higher than 1614 1614 1615 -if you leave logic parameter blank, it is considered 0 1627 +if you leave the logic parameter blank, it is considered 0 1616 1616 ))) 1617 1617 |(% style="width:137px" %)**Examples**|(% style="width:361px" %)((( 1618 1618 AT+VOLMAX=20000 ... ... @@ -1643,7 +1643,7 @@ 1643 1643 1644 1644 **1**: higher than 1645 1645 1646 -if you leave logic parameter blank, it is considered 1 (higher than) 1658 +if you leave the logic parameter blank, it is considered 1 (higher than) 1647 1647 ))) 1648 1648 |(% style="width:140px" %)**Example**|(% style="width:358px" %)((( 1649 1649 A5 **4E 20** ... ... @@ -1907,7 +1907,7 @@ 1907 1907 ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1908 1908 1909 1909 1910 -This command controls the behavior of the node when the combined size of the MAC commands (MACANS) from the server and the payload exceed sthe allowed byte limit for the current data rate (DR). The command provides two modes: one enables splitting the data into batches to ensure compliance with the byte limit, while the other prioritizes the payload and ignores the MACANS in cases of overflow.1922 +This command controls the behavior of the node when the combined size of the MAC commands (MACANS) from the server and the payload exceed the allowed byte limit for the current data rate (DR). The command provides two modes: one enables splitting the data into batches to ensure compliance with the byte limit, while the other prioritizes the payload and ignores the MACANS in cases of overflow. 1911 1911 1912 1912 (% style="color:#037691" %)**AT Command** 1913 1913 ... ... @@ -1976,15 +1976,15 @@ 1976 1976 There is no downlink option available for this feature. 1977 1977 1978 1978 1979 -==== 3.4.2.26 Query firmware version, frequency band, sub 1991 +==== 3.4.2.26 Query firmware version, frequency band, subband, and TDC time ==== 1980 1980 1981 1981 1982 -This command is used to query key information about the device, including its firmware version, frequency band, sub 1994 +This command is used to query key information about the device, including its firmware version, frequency band, subband, and TDC time. By sending the specified payload as a downlink, the server can retrieve this essential data from the device. 1983 1983 1984 1984 * ((( 1985 1985 (% style="color:#037691" %)**Downlink Payload**(%%)**:** 1986 1986 1987 -(% style="color:blue" %)**26 01 ** (%%) ~/~/ The downlink payload 26 01 is used to query the device's firmware version, frequency band, sub 1999 +(% style="color:blue" %)**26 01 ** (%%) ~/~/ The downlink payload 26 01 is used to query the device's firmware version, frequency band, subband, and TDC time. 1988 1988 1989 1989 1990 1990 ... ... @@ -2039,7 +2039,7 @@ 2039 2039 * Ensure the following options are turned on. 2040 2040 ** Enable integration 2041 2041 ** Debug mode 2042 -** Allow creat edevices or assets2054 +** Allow creating devices or assets 2043 2043 * Click the **Next** button. you will be navigated to the **Uplink data converter** tab. 2044 2044 2045 2045 [[image:thingseye-io-step-2.png]] ... ... @@ -2349,7 +2349,7 @@ 2349 2349 == 3.7 LED Indicators == 2350 2350 2351 2351 2352 -The table below lists the behavior of LED indicators for each port function. 2364 +The table below lists the behaviour of LED indicators for each port function. 2353 2353 2354 2354 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 2355 2355 |(% style="background-color:#4f81bd; color:white; width:50px" %)**LEDs**|(% style="background-color:#4f81bd; color:white; width:460px" %)**Feature** ... ... @@ -2356,11 +2356,11 @@ 2356 2356 |**PWR**|Always on when there is power 2357 2357 |**TX**|((( 2358 2358 ((( 2359 -Device boot: TX blinks 5 times. 2371 +Device booting: TX blinks 5 times. 2360 2360 ))) 2361 2361 2362 2362 ((( 2363 -Successful network join: TX remains ON for 5 seconds. 2375 +Successful network joins: TX remains ON for 5 seconds. 2364 2364 ))) 2365 2365 2366 2366 ((( ... ... @@ -2444,13 +2444,13 @@ 2444 2444 * ##**AT+FCU**##: Get or set the Frame Counter Uplink (FCntUp) 2445 2445 * ##**AT+FCD**##: Get or set the Frame Counter Downlink (FCntDown) 2446 2446 * ##**AT+CLASS**##: Get or set the Device Class 2447 -* ##**AT+JOIN**##: Join network2459 +* ##**AT+JOIN**##: Join Network 2448 2448 * ##**AT+NJS**##: Get OTAA Join Status 2449 2449 * ##**AT+SENDB**##: Send hexadecimal data along with the application port 2450 2450 * ##**AT+SEND**##: Send text data along with the application port 2451 -* ##**AT+RECVB**##: Print last received data in binary format (with hexadecimal values) 2452 -* ##**AT+RECV**##: Print last received data in raw format 2453 -* ##**AT+VER**##: Get current image version and Frequency Band 2463 +* ##**AT+RECVB**##: Print the last received data in binary format (with hexadecimal values) 2464 +* ##**AT+RECV**##: Print the last received data in raw format 2465 +* ##**AT+VER**##: Get the current image version and Frequency Band 2454 2454 * ##**AT+CFM**##: Get or Set the confirmation mode (0-1) 2455 2455 * ##**AT+CFS**##: Get confirmation status of the last AT+SEND (0-1) 2456 2456 * ##**AT+SNR**##: Get the SNR of the last received packet ... ... @@ -2478,7 +2478,7 @@ 2478 2478 ))) 2479 2479 2480 2480 ((( 2481 -(% style="background-color:#dcdcdc" %)##**123456 ~/~/Enter the password to enable AT command saccess**##2493 +(% style="background-color:#dcdcdc" %)##**123456 ~/~/Enter the password to enable AT command access**## 2482 2482 ))) 2483 2483 2484 2484 ((( ... ... @@ -2486,7 +2486,7 @@ 2486 2486 ))) 2487 2487 2488 2488 ((( 2489 -(% style="background-color:#dcdcdc" %)##**123456 ~/~/Enter the password to enable AT command saccess**##2501 +(% style="background-color:#dcdcdc" %)##**123456 ~/~/Enter the password to enable AT command access**## 2490 2490 ))) 2491 2491 2492 2492 ((( ... ... @@ -2517,7 +2517,7 @@ 2517 2517 2518 2518 2519 2519 ((( 2520 -(% style="background-color:#dcdcdc" %)**123456**(%%) ~/~/ Enter password to enable AT commands access 2532 +(% style="background-color:#dcdcdc" %)**123456**(%%) ~/~/ Enter the password to enable AT commands access 2521 2521 ))) 2522 2522 ))) 2523 2523 ... ... @@ -2526,7 +2526,7 @@ 2526 2526 ))) 2527 2527 2528 2528 ((( 2529 -(% style="background-color:#dcdcdc" %)** 123456**(%%) ~/~/ Enter password to enable AT command saccess2541 +(% style="background-color:#dcdcdc" %)** 123456**(%%) ~/~/ Enter the password to enable AT command access 2530 2530 ))) 2531 2531 2532 2532 ((( ... ... @@ -2608,7 +2608,7 @@ 2608 2608 == 5.1 Counting how many objects pass through the flow line == 2609 2609 2610 2610 2611 -See [[How to set up to setup counting for objects passing through the flow line>>How to set up to count objects pass in flow line]] ?2623 +See [[How to set up to setup counting for objects passing through the flow line>>How to set up to count objects pass in flow line]]. 2612 2612 2613 2613 2614 2614 = 6. FAQ = ... ... @@ -2678,13 +2678,13 @@ 2678 2678 ))) 2679 2679 2680 2680 ((( 2681 -You can follow the introductions on [[how to upgrade image>>||anchor="H5.1Howtoupgradetheimage3F"]]. When downloading, select the required image file. 2693 +You can follow the introductions on [[how to upgrade the image>>||anchor="H5.1Howtoupgradetheimage3F"]]. When downloading, select the required image file. 2682 2682 ))) 2683 2683 2684 2684 ((( 2685 2685 2686 2686 2687 -== 6.3 How to setup LT-22222-L to work with a Single Channel Gateway, such as LG01/LG02? == 2699 +== 6.3 How to set up LT-22222-L to work with a Single Channel Gateway, such as LG01/LG02? == 2688 2688 2689 2689 2690 2690 ))) ... ... @@ -2786,9 +2786,9 @@ 2786 2786 * If the device is not properly shut down and is directly powered off. 2787 2787 * It will default to a power-off state. 2788 2788 * In modes 2 to 5, the DO/RO status and pulse count are saved to flash memory. 2789 -* After a restart, the status before the power failure will be read from flash.2801 +* After a restart, the status before the power failure will be read from Flash. 2790 2790 2791 -== 6.8 Can I setup LT-22222-L as a NC (Normally Closed) relay? == 2803 +== 6.8 Can I set up LT-22222-L as an NC (Normally Closed) relay? == 2792 2792 2793 2793 2794 2794 The LT-22222-L's built-in relay is Normally Open (NO). You can use an external relay to achieve a Normally Closed (NC) configuration. The circuit diagram is shown below: