Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 9 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.pradeeka - Content
-
... ... @@ -21,7 +21,6 @@ 21 21 22 22 == 1.1 What is the LT-22222-L I/O Controller? == 23 23 24 - 25 25 ((( 26 26 ((( 27 27 {{info}} ... ... @@ -28,7 +28,7 @@ 28 28 **This manual is also applicable to the LT-33222-L.** 29 29 {{/info}} 30 30 31 -The Dragino (% style="color:blue" %)**LT-22222-L I/O Controller**(%%) is an advanced LoRaWAN enddevice designed to provide seamless wireless long-range connectivity with various I/O options, including analog current and voltage inputs, digital inputs and outputs, and relay outputs.30 +The Dragino (% style="color:blue" %)**LT-22222-L I/O Controller**(%%) is an advanced LoRaWAN device designed to provide seamless wireless long-range connectivity with various I/O options, including analog current and voltage inputs, digital inputs and outputs, and relay outputs. 32 32 33 33 The LT-22222-L I/O Controller simplifies and enhances I/O monitoring and controlling. It is ideal for professional applications in wireless sensor networks, including irrigation systems, smart metering, smart cities, building automation, and more. These controllers are designed for easy, cost-effective deployment using LoRa wireless technology. 34 34 ))) ... ... @@ -41,24 +41,23 @@ 41 41 ((( 42 42 You can connect the LT-22222-L I/O Controller to a LoRaWAN network service provider in several ways: 43 43 44 -* If there is public LoRaWAN network coverage in the area where you plan to install the device (e.g., The Things Stack CommunityNetwork), you can select a network and register the LT-22222-L I/O controller with it.43 +* If there is public LoRaWAN network coverage in the area where you plan to install the device (e.g., The Things Network), you can select a network and register the LT-22222-L I/O controller with it. 45 45 * If there is no public LoRaWAN coverage in your area, you can set up a LoRaWAN gateway, or multiple gateways, and connect them to a LoRaWAN network server to create adequate coverage. Then, register the LT-22222-L I/O controller with this network. 46 46 * Setup your own private LoRaWAN network. 46 + 47 +{{info}} 48 + You can use a LoRaWAN gateway, such as the [[Dragino LG308>>https://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], to expand or create LoRaWAN coverage in your area. 49 +{{/info}} 47 47 ))) 48 48 49 49 ((( 50 - 53 +[[image:1653295757274-912.png]] 51 51 52 - Thenetwork diagram below illustrates how the LT-22222-L communicates with a typical LoRaWAN network.55 + 53 53 ))) 54 54 55 -(% class="wikigeneratedid" %) 56 -[[image:lorawan-nw.jpg||height="354" width="900"]] 57 - 58 - 59 59 == 1.2 Specifications == 60 60 61 - 62 62 (% style="color:#037691" %)**Hardware System:** 63 63 64 64 * STM32L072xxxx MCU ... ... @@ -100,7 +100,6 @@ 100 100 101 101 == 1.3 Features == 102 102 103 - 104 104 * LoRaWAN Class A & Class C modes 105 105 * Optional Customized LoRa Protocol 106 106 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 ... ... @@ -111,7 +111,6 @@ 111 111 112 112 == 1.4 Applications == 113 113 114 - 115 115 * Smart buildings & home automation 116 116 * Logistics and supply chain management 117 117 * Smart metering ... ... @@ -119,74 +119,54 @@ 119 119 * Smart cities 120 120 * Smart factory 121 121 122 -== 1.5HardwareVariants==118 +== 2. Assembling the device == 123 123 124 - 125 -(% border="1" cellspacing="3" style="width:510px" %) 126 -|(% style="background-color:#4f81bd; color:white; width:94px" %)**Model**|(% style="background-color:#4f81bd; color:white; width:172px" %)**Photo**|(% style="background-color:#4f81bd; color:white; width:244px" %)**Description** 127 -|(% style="width:94px" %)**LT-22222-L**|(% style="width:172px" %)((( 128 -(% style="text-align:center" %) 129 -[[image:lt33222-l.jpg||height="110" width="95"]] 130 -)))|(% style="width:256px" %)((( 131 -* 2 x Digital Input (Bi-direction) 132 -* 2 x Digital Output 133 -* 2 x Relay Output (5A@250VAC / 30VDC) 134 -* 2 x 0~~20mA Analog Input (res:0.01mA) 135 -* 2 x 0~~30V Analog Input (res:0.01v) 136 -* 1 x Counting Port 137 -))) 138 - 139 -= 2. Assembling the device = 140 - 141 141 == 2.1 Connecting the antenna == 142 142 143 - 144 144 Connect the LoRa antenna to the antenna connector, **ANT**,** **located on the top right side of the device, next to the upper screw terminal block. Secure the antenna by tightening it clockwise. 145 145 146 146 {{warning}} 147 - **Warning! Do not power on the device without connecting the antenna.**125 +Warning! Do not power on the device without connecting the antenna. 148 148 {{/warning}} 149 149 150 - 151 151 == 2.2 Terminals == 152 152 130 +The LT-22222-L has two screw terminal blocks. The upper screw treminal block has 6 terminals and the lower screw terminal block has 10 terminals. 153 153 154 - TheLT-22222-L hastwo screw terminal blocks.The upperscrew treminalblock has 6 screwterminalsandthe lowerscrew terminal blockhas 10 screwterminals.132 +Upper screw terminal block (from left to right): 155 155 156 -**Upper screw terminal block (from left to right):** 134 +(% style="width:634px" %) 135 +|=(% style="width: 295px;" %)Terminal|=(% style="width: 338px;" %)Function 136 +|(% style="width:295px" %)GND|(% style="width:338px" %)Ground 137 +|(% style="width:295px" %)VIN|(% style="width:338px" %)Input Voltage 138 +|(% style="width:295px" %)AVI2|(% style="width:338px" %)Analog Voltage Input Terminal 2 139 +|(% style="width:295px" %)AVI1|(% style="width:338px" %)Analog Voltage Input Terminal 1 140 +|(% style="width:295px" %)ACI2|(% style="width:338px" %)Analog Current Input Terminal 2 141 +|(% style="width:295px" %)ACI1|(% style="width:338px" %)Analog Current Input Terminal 1 157 157 158 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:381px" %) 159 -|=(% style="width: 139px;background-color:#4f81bd;color:white" %)Screw Terminal|=(% style="width: 242px;background-color:#4f81bd;color:white" %)Function 160 -|(% style="width:139px" %)GND|(% style="width:242px" %)Ground 161 -|(% style="width:139px" %)VIN|(% style="width:242px" %)Input Voltage 162 -|(% style="width:139px" %)AVI2|(% style="width:242px" %)Analog Voltage Input Terminal 2 163 -|(% style="width:139px" %)AVI1|(% style="width:242px" %)Analog Voltage Input Terminal 1 164 -|(% style="width:139px" %)ACI2|(% style="width:242px" %)Analog Current Input Terminal 2 165 -|(% style="width:139px" %)ACI1|(% style="width:242px" %)Analog Current Input Terminal 1 143 +Lower screw terminal block (from left to right): 166 166 167 -**Lower screw terminal block (from left to right):** 145 +(% style="width:633px" %) 146 +|=(% style="width: 296px;" %)Terminal|=(% style="width: 334px;" %)Function 147 +|(% style="width:296px" %)RO1-2|(% style="width:334px" %)Relay Output 1 148 +|(% style="width:296px" %)RO1-1|(% style="width:334px" %)Relay Output 1 149 +|(% style="width:296px" %)RO2-2|(% style="width:334px" %)Relay Output 2 150 +|(% style="width:296px" %)RO2-1|(% style="width:334px" %)Relay Output 2 151 +|(% style="width:296px" %)DI2+|(% style="width:334px" %)Digital Input 2 152 +|(% style="width:296px" %)DI2-|(% style="width:334px" %)Digital Input 2 153 +|(% style="width:296px" %)DI1+|(% style="width:334px" %)Digital Input 1 154 +|(% style="width:296px" %)DI1-|(% style="width:334px" %)Digital Input 1 155 +|(% style="width:296px" %)DO2|(% style="width:334px" %)Digital Output 2 156 +|(% style="width:296px" %)DO1|(% style="width:334px" %)Digital Output 1 168 168 169 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:253px" %) 170 -|=(% style="width: 125px;background-color:#4f81bd;color:white" %)Screw Terminal|=(% style="width: 128px;background-color:#4f81bd;color:white" %)Function 171 -|(% style="width:125px" %)RO1-2|(% style="width:128px" %)Relay Output 1 172 -|(% style="width:125px" %)RO1-1|(% style="width:128px" %)Relay Output 1 173 -|(% style="width:125px" %)RO2-2|(% style="width:128px" %)Relay Output 2 174 -|(% style="width:125px" %)RO2-1|(% style="width:128px" %)Relay Output 2 175 -|(% style="width:125px" %)DI2+|(% style="width:128px" %)Digital Input 2 176 -|(% style="width:125px" %)DI2-|(% style="width:128px" %)Digital Input 2 177 -|(% style="width:125px" %)DI1+|(% style="width:128px" %)Digital Input 1 178 -|(% style="width:125px" %)DI1-|(% style="width:128px" %)Digital Input 1 179 -|(% style="width:125px" %)DO2|(% style="width:128px" %)Digital Output 2 180 -|(% style="width:125px" %)DO1|(% style="width:128px" %)Digital Output 1 158 +== 2.3 Powering the device == 181 181 160 +The LT-22222-L I/O Controller can be powered by a **7–24V DC** power source. Connect your power supply’s positive wire to the VIN and the negative wire to the GND screw terminals. The power indicator **(PWR) LED** will turn on when the device is properly powered. 182 182 183 - ==2.3 ConnectingLT-22222-L to aPowerSource==162 +Once powered, the **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** The Things Stack. The **TX LED** will be on for **5 seconds** after joining the network. When there is a **downlink** message from the server, the **RX LED** will be on for **1 second**. When the device is sending an uplink message to the server, the **TX LED** will be on for **1 second**. See also LED status. 184 184 185 - 186 -The LT-22222-L I/O Controller can be powered by a **7–24V DC** power source. Connect your power supply’s **positive wire** to the **VIN** and the **negative wire** to the **GND** screw terminals. The power indicator **(PWR) LED** will turn on when the device is properly powered. 187 - 188 188 {{warning}} 189 - **We recommend that you power on the LT-22222-L afteradding its registration information to theLoRaWAN network server. Otherwise, the device will continuously send join-request messages to attempt to join a LoRaWAN network but will fail.**165 +We recommend that you power on the LT-22222-L after configuring its registration information with a LoRaWAN network server. Otherwise, the device will continuously send join-request messages to attempt to join a LoRaWAN network but will fail. 190 190 {{/warning}} 191 191 192 192 ... ... @@ -193,59 +193,37 @@ 193 193 [[image:1653297104069-180.png]] 194 194 195 195 196 -= 3. Registering LT-22222-Lwith a LoRaWAN Network Server =172 += 3. Registering with a LoRaWAN Network Server = 197 197 174 +By default, the LT-22222-L is configured to operate in LoRaWAN Class C mode. It supports OTAA (Over-the-Air Activation), the most secure method for activating a device with a LoRaWAN network server. The LT-22222-L comes with device registration information that allows you to register it with a LoRaWAN network, enabling the device to perform OTAA activation with the network server upon initial power-up and after any subsequent reboots. 198 198 199 - TheLT-22222-L supportsbothOTAA(Over-the-AirActivation)andABP (ActivationBy Personalization)methodsto activatewithaLoRaWANNetworkServer.However,OTAAisthemostsecuremethod foractivatinga device witha LoRaWAN NetworkServer.OTAA regeneratessessionysuponinitialregistrationandregeneratesnewsessionkeysafteranysubsequentreboots. Bydefault, theLT-22222-L isconfiguredtooperatein LoRaWAN ClassCmode.176 +After powering on, the **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** the LoRaWAN network. The **TX LED** will be on for **5 seconds** after joining the network. When there is a **downlink** message from the server, the **RX LED** will be on for **1 second**. When the device is sending an uplink message to the server, the **TX LED** will be on for **1 second**. See also LED status. 200 200 178 +In case you can't set the root key and other identifiers in the network server and must use them from the server, you can use [[AT Commands>>||anchor="H4.UseATCommand"]] to configure them on the device. 201 201 202 - ===3.2.1Prerequisites===180 +The network diagram below shows how the LT-22222-L is connected to a typical LoRaWAN network. 203 203 182 +[[image:image-20220523172350-1.png||height="266" width="864"]] 204 204 205 - TheLT-22222-L comes with device registration information such as DevEUI, AppEUI, and AppKey that allows you to register it with a LoRaWAN network.Theseregistration information can befound on a sticker that can be found insidethepackage. Pleasekeep the **registration information** sticker in a safe place for future reference.184 +=== 3.2.1 Prerequisites === 206 206 186 +Make sure you have the device registration information such as DevEUI, AppEUI, and AppKey with you. The registration information can be found on a sticker that can be found inside the package. Please keep the **registration information** sticker in a safe place for future reference. 187 + 207 207 [[image:image-20230425173427-2.png||height="246" width="530"]] 208 208 209 -{{info}} 210 -In case you can't set the root key and other identifiers in the network server and must use them from the server, you can use [[AT Commands>>||anchor="H4.UseATCommand"]] to configure them on the device. 211 -{{/info}} 212 - 213 213 The following subsections explain how to register the LT-22222-L with different LoRaWAN network server providers. 214 214 192 +=== 3.2.2 The Things Stack Sandbox (TTSS) === 215 215 216 -=== 3.2.2 The Things Stack === 217 - 218 - 219 -This section guides you through how to register your LT-22222-L with The Things Stack Sandbox. 220 - 221 -{{info}} 222 222 The Things Stack Sandbox was formally called The Things Stack Community Edition. 223 -{{/info}} 224 224 225 - 226 -The network diagram below illustrates the connection between the LT-22222-L and The Things Stack, as well as how the data can be integrated with the ThingsEye IoT platform. 227 - 228 - 229 -[[image:dragino-lorawan-nw-lt-22222-n.jpg||height="374" width="1400"]] 230 - 231 -{{info}} 232 - You can use a LoRaWAN gateway, such as the [[Dragino LPS8N>>https://www.dragino.com/products/lora-lorawan-gateway/item/200-lps8n.html]], to expand or create LoRaWAN coverage in your area. 233 -{{/info}} 234 - 235 - 236 -==== 3.2.2.1 Setting up ==== 237 - 238 - 239 -* Sign up for a free account with [[The Things Stack Sandbox>>https://eu1.cloud.thethings.network]] if you do not have one yet. 240 -* Log in to your The Things Stack Sandbox account. 241 -* Create an **application** with The Things Stack if you do not have one yet (E.g., dragino-docs). 242 -* Go to your application's page and click on the **End devices** in the left menu. 196 +* Log in to your [[The Things Stack Sandbox>>https://eu1.cloud.thethings.network]] account. 197 +* Create an application with The Things Stack if you do not have one yet. 198 +* Go to your application page and click on the **End devices** in the left menu. 243 243 * On the End devices page, click on **+ Register end device**. Two registration options are available: 244 244 201 +==== 3.2.2.1 Using the LoRaWAN Device Repository ==== 245 245 246 -==== 3.2.2.2 Using the LoRaWAN Device Repository ==== 247 - 248 - 249 249 * On the **Register end device** page: 250 250 ** Select the option **Select the end device in the LoRaWAN Device Repository **under **Input method**. 251 251 ** Select the **End device brand**, **Model**, **Hardware version**, **Firmware version**, and **Profile (Region)** from the respective dropdown lists. ... ... @@ -256,7 +256,7 @@ 256 256 *** **Profile (Region)**: Select the region that matches your device. 257 257 ** Select the **Frequency plan** that matches your device from the **Frequency plan** dropdown list. 258 258 259 -[[image:lt-22222-l-dev-repo-reg-p1.png]] 213 +[[image:lt-22222-l-dev-repo-reg-p1.png||height="625" width="1000"]] 260 260 261 261 262 262 * Register end device page continued... ... ... @@ -266,12 +266,12 @@ 266 266 ** In the **End device ID** field, enter a unique name for your LT-22222-N within this application. 267 267 ** Under **After registration**, select the **View registered end device** option. 268 268 269 -[[image:lt-22222-l-dev-repo-reg-p2.png]] 223 +[[image:lt-22222-l-dev-repo-reg-p2.png||height="625" width="1000"]] 270 270 225 +==== ==== 271 271 272 -==== 3.2.2. 3Adding device manually ====227 +==== 3.2.2.2 Adding device manually ==== 273 273 274 - 275 275 * On the **Register end device** page: 276 276 ** Select the option **Enter end device specifies manually** under **Input method**. 277 277 ** Select the **Frequency plan** that matches your device from the **Frequency plan** dropdown list. ... ... @@ -281,11 +281,11 @@ 281 281 ** Select the option **Over the air activation (OTAA)** under the **Activation mode.** 282 282 ** Select **Class C (Continuous)** from the **Additional LoRaWAN class capabilities** dropdown list. 283 283 284 -[[image:lt-22222-l-manually-p1.png]] 238 +[[image:lt-22222-l-manually-p1.png||height="625" width="1000"]] 285 285 286 286 287 287 * Register end device page continued... 288 -** Enter the **AppEUI** in the **JoinEUI** field and click the **Confirm** button. If The Things Stack accepts the JoinEUI you provided, it will display the message ' //**This end device can be registered on the network**//'242 +** Enter the **AppEUI** in the **JoinEUI** field and click the **Confirm** button. If The Things Stack accepts the JoinEUI you provided, it will display the message 'This end device can be registered on the network' 289 289 ** In the **DevEUI** field, enter the **DevEUI**. 290 290 ** In the **AppKey** field, enter the **AppKey**. 291 291 ** In the **End device ID** field, enter a unique name for your LT-22222-N within this application. ... ... @@ -292,57 +292,41 @@ 292 292 ** Under **After registration**, select the **View registered end device** option. 293 293 ** Click the **Register end device** button. 294 294 295 -[[image:lt-22222-l-manually-p2.png]] 249 +[[image:lt-22222-l-manually-p2.png||height="625" width="1000"]] 296 296 297 297 298 298 You will be navigated to the **Device overview** page. 299 299 300 300 301 -[[image:lt-22222-device-overview.png]] 255 +[[image:lt-22222-device-overview.png||height="625" width="1000"]] 302 302 303 303 304 -==== 3.2.2. 4Joining ====258 +==== 3.2.2.3 Joining ==== 305 305 260 +On the Device overview page, click on **Live data** tab. The Live data panel for your device will display. 306 306 307 - On theDevice'spage,clickon **Live data**tab.TheLive datapanelfor yourdevice will display.262 +Now power on your LT-22222-L. It will begin joining The Things Stack. In the **Live data** panel, you can see the **join-request** and **join-accept** messages exchanged between the device and the network server. Once successfully joined, the device will send its first **uplink data message** to the application it belongs to (in this example, **dragino-docs**). 308 308 309 -Now power on your LT-22222-L. The **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** The Things Stack network server. The **TX LED** will be on for **5 seconds** after joining the network. In the **Live data** panel, you can see the **join-request** and **join-accept** messages exchanged between the device and the network server. 310 310 265 +[[image:lt-22222-join-network.png||height="625" width="1000"]] 311 311 312 -[[image:lt-22222-l-joining.png]] 313 313 268 +By default, you will receive an uplink data message from the device every 10 minutes. 314 314 315 -==== 3.2.2.5 Uplinks ==== 316 - 317 - 318 -After successfully joining, the device will send its first **uplink data message** to the application it belongs to (in this example, **dragino-docs**). When the LT-22222-L sends an uplink message to the server, the **TX LED** turns on for **1 second**. By default, you will receive an uplink data message from the device every 10 minutes. 319 - 320 320 Click on one of a **Forward uplink data messages **to see its payload content. The payload content is encapsulated within the decode_payload {} JSON object. 321 321 322 322 [[image:lt-22222-ul-payload-decoded.png]] 323 323 324 324 325 -If you can't see the decoded payload, it is because you haven't added the uplink formatter code. To add the uplink formatter code, select ** Applications > your application >End devices** > **your end device**275 +If you can't see the decoded payload, it is because you haven't added the uplink formatter code. To add the uplink formatter code, select **End devices** > **LT-22222-L** > **Payload formatters** > **Uplink**. Then select **Use Device repository formatters** for the **Formatter type** dropdown. Click the **Save changes** button to apply the changes. 326 326 327 327 {{info}} 328 328 The Things Stack provides two levels of payload formatters: application level and device level. The device-level payload formatters **override **the application-level payload formatters. 329 329 {{/info}} 330 330 331 -[[image:lt-22222-ul-payload-fmt.png]] 281 +[[image:lt-22222-ul-payload-fmt.png||height="686" width="1000"]] 332 332 333 333 334 -We also have a payload formatter that resolves some decoding issues present in the Device Repository formatter. You can add it under the Custom JavaScript formatter. It can be found [[here>>https://github.com/dragino/dragino-end-node-decoder/blob/main/LT22222-L/v1.6_decoder_ttn%20.txt]]: 335 - 336 -(% class="wikigeneratedid" %) 337 -[[image:lt-22222-l-js-custom-payload-formatter.png]] 338 - 339 - 340 -==== 3.2.2.6 Downlinks ==== 341 - 342 - 343 -When the LT-22222-L receives a downlink message from the server, the **RX LED** turns on for **1 second**. 344 - 345 - 346 346 == 3.3 Working Modes and Uplink Payload formats == 347 347 348 348 ... ... @@ -362,10 +362,8 @@ 362 362 363 363 The uplink messages are sent over LoRaWAN FPort=2. By default, an uplink message is sent every 10 minutes. 364 364 365 - 366 366 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 367 367 368 - 369 369 ((( 370 370 This is the default mode. 371 371 ... ... @@ -438,7 +438,6 @@ 438 438 439 439 MOD = 1 440 440 441 - 442 442 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 443 443 444 444 ... ... @@ -517,7 +517,6 @@ 517 517 518 518 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 519 519 520 - 521 521 (% style="color:red" %)**Note: The maximum count depends on the bytes it is. 522 522 The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 523 523 It starts counting again when it reaches the maximum value.** ... ... @@ -571,7 +571,6 @@ 571 571 572 572 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 573 573 574 - 575 575 (% style="color:red" %)**Note:The maximum count depends on the bytes it is. 576 576 The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 577 577 It starts counting again when it reaches the maximum value.** ... ... @@ -623,25 +623,24 @@ 623 623 ))) 624 624 625 625 ((( 626 -AT Commands for counting are similar to the [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]s. 559 +Other AT Commands for counting are similar to the [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]s. 627 627 ))) 628 628 629 629 ((( 630 630 **In addition to that, below are the commands for AVI1 Counting:** 631 631 632 -(% style="color:blue" %)**AT+SETCNT=3,60 **(%%)**(Sets AVI 1Count to 60)**565 +(% style="color:blue" %)**AT+SETCNT=3,60 **(%%)**(Sets AVI Count to 60)** 633 633 634 -(% style="color:blue" %)**AT+VOLMAX=20000 **(%%)**(If theAVI1 voltageishigher than VOLMAX (20000mV =20V),thecounter increasesby1)**567 +(% style="color:blue" %)**AT+VOLMAX=20000 **(%%)**(If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 635 635 636 -(% style="color:blue" %)**AT+VOLMAX=20000,0 **(%%)**(If theAVI1 voltageislower than VOLMAX (20000mV =20V), counter increasesby1)**569 +(% style="color:blue" %)**AT+VOLMAX=20000,0 **(%%)**(If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 637 637 638 -(% style="color:blue" %)**AT+VOLMAX=20000,1 **(%%)**(If theAVI1 voltageishigher than VOLMAX (20000mV =20V), counter increasesby1)**571 +(% style="color:blue" %)**AT+VOLMAX=20000,1 **(%%)**(If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 639 639 ))) 640 640 641 641 642 642 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 643 643 644 - 645 645 (% style="color:red" %)**Note:The maximum count depends on the bytes it is. 646 646 The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 647 647 It starts counting again when it reaches the maximum value.** ... ... @@ -755,9 +755,9 @@ 755 755 756 756 (% style="color:#037691" %)**LoRaWAN Downlink Commands for Setting the Trigger Conditions:** 757 757 758 - **Type Code**: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**690 +Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 759 759 760 - **Format**: AA xx yy1 yy1 yy2 yy2 yy3 yy3 yy4 yy4692 +Format: AA xx yy1 yy1 yy2 yy2 yy3 yy3 yy4 yy4 761 761 762 762 AA: Type Code for this downlink Command: 763 763 ... ... @@ -786,7 +786,7 @@ 786 786 787 787 MOD6 Payload: total of 11 bytes 788 788 789 -(% border="1" cellspacing=" 3" style="background-color:#f2f2f2; width:515px" %)721 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 790 790 |(% style="background-color:#4f81bd; color:white; width:60px" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white; width:69px" %)**1**|(% style="background-color:#4f81bd; color:white; width:69px" %)**1**|(% style="background-color:#4f81bd; color:white; width:109px" %)**1**|(% style="background-color:#4f81bd; color:white; width:49px" %)**6**|(% style="background-color:#4f81bd; color:white; width:109px" %)**1**|(% style="background-color:#4f81bd; color:white; width:50px" %)**1** 791 791 |Value|((( 792 792 TRI_A FLAG ... ... @@ -800,7 +800,7 @@ 800 800 801 801 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if the trigger is set for this part. Totally 1 byte as below 802 802 803 -(% border="1" cellspacing=" 3" style="background-color:#f2f2f2; width:515px" %)735 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 804 804 |**bit 7**|**bit 6**|**bit 5**|**bit 4**|**bit 3**|**bit 2**|**bit 1**|**bit 0** 805 805 |((( 806 806 AV1_LOW ... ... @@ -824,12 +824,12 @@ 824 824 825 825 **Example:** 826 826 827 -10100000: This means the systemis configuredto use the triggersAV1_LOW and AV2_LOW.759 +10100000: Means the system has configure to use the trigger: AV1_LOW and AV2_LOW 828 828 829 829 830 830 (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1 byte as below 831 831 832 -(% border="1" cellspacing=" 3" style="background-color:#f2f2f2; width:515px" %)764 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 833 833 |**bit 7**|**bit 6**|**bit 5**|**bit 4**|**bit 3**|**bit 2**|**bit 1**|**bit 0** 834 834 |((( 835 835 AV1_LOW ... ... @@ -853,31 +853,31 @@ 853 853 854 854 **Example:** 855 855 856 -10000000: The uplink is triggered by AV1_LOW,indicatingthatthe voltage is too low.788 +10000000: Means this uplink is triggered by AV1_LOW. That means the voltage is too low. 857 857 858 858 859 859 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 860 860 861 -(% border="1" cellspacing=" 3" style="background-color:#f2f2f2; width:515px" %)862 -|(% style="width: 50px" %)**bit 7**|(% style="width:50px" %)**bit 6**|(% style="width:50px" %)**bit 5**|(% style="width:50px" %)**bit 4**|(% style="width:90px" %)**bit 3**|(% style="width:80px" %)**bit 2**|(% style="width:90px" %)**bit 1**|(% style="width:95px" %)**bit 0**863 -|(% style="width:4 9px" %)N/A|(% style="width:53px" %)N/A|(% style="width:53px" %)N/A|(% style="width:55px" %)N/A|(% style="width:99px" %)DI2_STATUS|(% style="width:83px" %)DI2_FLAG|(% style="width:98px" %)DI1_STATUS|(% style="width:85px" %)DI1_FLAG793 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:674px" %) 794 +|(% style="width:64px" %)**bit 7**|(% style="width:68px" %)**bit 6**|(% style="width:63px" %)**bit 5**|(% style="width:66px" %)**bit 4**|(% style="width:109px" %)**bit 3**|(% style="width:93px" %)**bit 2**|(% style="width:109px" %)**bit 1**|(% style="width:99px" %)**bit 0** 795 +|(% style="width:64px" %)N/A|(% style="width:68px" %)N/A|(% style="width:63px" %)N/A|(% style="width:66px" %)N/A|(% style="width:109px" %)DI2_STATUS|(% style="width:93px" %)DI2_FLAG|(% style="width:109px" %)DI1_STATUS|(% style="width:99px" %)DI1_FLAG 864 864 865 -* Each bit shows which status has been triggered on this uplink. 797 +* Each bits shows which status has been triggered on this uplink. 866 866 867 867 **Example:** 868 868 869 -00000111: This means both DI1 and DI2 triggersare enabled,and this packet is trigger by DI1.801 +00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. 870 870 871 -00000101: This means both DI1 and DI2 triggersare enabled.803 +00000101: Means both DI1 and DI2 trigger are enabled. 872 872 873 873 874 -(% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable d. 0x00: MOD6 is disabled.806 +(% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 875 875 876 -Downlink command to poll /requestMOD6 status:808 +Downlink command to poll MOD6 status: 877 877 878 878 **AB 06** 879 879 880 -When device receivesthis command, it will send the MOD6 payload.812 +When device got this command, it will send the MOD6 payload. 881 881 882 882 883 883 === 3.3.7 Payload Decoder === ... ... @@ -891,7 +891,6 @@ 891 891 892 892 == 3.4 Configure LT-22222-L via AT Commands or Downlinks == 893 893 894 - 895 895 ((( 896 896 You can configure LT-22222-L I/O Controller via AT Commands or LoRaWAN Downlinks. 897 897 ))) ... ... @@ -906,25 +906,19 @@ 906 906 907 907 * (% style="color:blue" %)**Sensor-related commands**(%%): 908 908 909 - 910 910 === 3.4.1 Common commands === 911 911 912 - 913 913 ((( 914 914 These are available for each sensors and include actions such as changing the uplink interval or resetting the device. For firmware v1.5.4, you can find the supported common commands under: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]s. 915 - 916 - 917 917 ))) 918 918 919 919 === 3.4.2 Sensor-related commands === 920 920 921 - 922 922 These commands are specially designed for the LT-22222-L. Commands can be sent to the device using options such as an AT command or a LoRaWAN downlink payload. 923 923 924 924 925 -==== 3.4.2.1 Set Transmit /UplinkInterval ====851 +==== 3.4.2.1 Set Transmit Interval ==== 926 926 927 - 928 928 Sets the uplink interval of the device. The default uplink transmission interval is 10 minutes. 929 929 930 930 (% style="color:#037691" %)**AT command** ... ... @@ -931,19 +931,12 @@ 931 931 932 932 (% border="2" style="width:500px" %) 933 933 |**Command**|AT+TDC=<time> 934 -|**Parameters**|**time **: uplink interval in milliseconds 935 -|**Get**|AT+TDC=? 936 -|**Response**|((( 937 -current uplink interval 938 - 939 -OK 940 -))) 941 -|**Set**|AT+TDC=<time> 942 -|**Response**|OK 859 +|**Response**| 860 +|**Parameters**|**time** : uplink interval is in milliseconds 943 943 |**Example**|((( 944 944 AT+TDC=30000 945 945 946 -Sets the uplink interval to **30 seconds**(30000milliseconds)864 +Sets the uplink interval to 30,000 milliseconds (30 seconds) 947 947 ))) 948 948 949 949 (% style="color:#037691" %)**Downlink payload** ... ... @@ -955,29 +955,27 @@ 955 955 |**Parameters**|((( 956 956 **prefix** : 0x01 957 957 958 -**time** : uplink interval in **seconds**, represented by**3 bytes**in**hexadecimal**.876 +**time** : uplink interval is in milliseconds, represented by 3 bytes in hexadecimal. 959 959 ))) 960 960 |**Example**|((( 961 -01 **00 001E**879 +01 **00 75 30** 962 962 963 -Sets the uplink interval to **30 seconds**881 +Sets the uplink interval to 30,000 milliseconds (30 seconds) 964 964 965 -Conversion: 30 (dec) = 00 0 01E(hex)883 +Conversion: 30000 (dec) = 00 75 30 (hex) 966 966 967 -See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30]] 968 - 969 -[[image:Screenshot 2024-11-23 at 18.27.11.png]] 885 +See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30000]] 970 970 ))) 971 971 972 972 ==== 3.4.2.2 Set the Working Mode (AT+MOD) ==== 973 973 974 - 975 975 Sets the working mode. 976 976 977 977 (% style="color:#037691" %)**AT command** 978 978 979 979 (% border="2" style="width:500px" %) 980 -|(% style="width:97px" %)**Command**|(% style="width:413px" %)AT+MOD=<working_mode> 895 +|(% style="width:97px" %)**Command**|(% style="width:413px" %)AT+MODE=<working_mode> 896 +|(% style="width:97px" %)**Response**|(% style="width:413px" %) 981 981 |(% style="width:97px" %)**Parameters**|(% style="width:413px" %)((( 982 982 **working_mode** : 983 983 ... ... @@ -993,18 +993,6 @@ 993 993 994 994 6 = Trigger Mode, Optional, used together with MOD1 ~~ MOD5 995 995 ))) 996 -|(% style="width:97px" %)**Get**|(% style="width:413px" %)AT+MOD=? 997 -|(% style="width:97px" %)**Response**|(% style="width:413px" %)((( 998 -Current working mode 999 - 1000 -OK 1001 -))) 1002 -|(% style="width:97px" %)**Set**|(% style="width:413px" %)AT+MOD=<working_mode> 1003 -|(% style="width:97px" %)**Response**|(% style="width:413px" %)((( 1004 -Attention:Take effect after ATZ 1005 - 1006 -OK 1007 -))) 1008 1008 |(% style="width:97px" %)**Example**|(% style="width:413px" %)((( 1009 1009 AT+MOD=2 1010 1010 ... ... @@ -1027,14 +1027,13 @@ 1027 1027 Sets the device to working mode 2 (Double DI Counting + DO + RO) 1028 1028 ))) 1029 1029 1030 -==== 3.4.2.3 Requestan uplinkfrom the device====934 +==== 3.4.2.3 Poll an uplink ==== 1031 1031 936 +Requests an uplink from LT-22222-L. 1032 1032 1033 -Requests an uplink from LT-22222-L. The content of the uplink payload varies based on the device's current working mode. 1034 - 1035 1035 (% style="color:#037691" %)**AT command** 1036 1036 1037 -There is no AT Command available forthisfeature.940 +There is no AT Command to request an uplink from LT-22222-L 1038 1038 1039 1039 (% style="color:#037691" %)**Downlink payload** 1040 1040 ... ... @@ -1042,7 +1042,7 @@ 1042 1042 |(% style="width:101px" %)**Payload**|(% style="width:397px" %)<prefix>FF 1043 1043 |(% style="width:101px" %)**Parameters**|(% style="width:397px" %)**prefix** : 0x08 1044 1044 |(% style="width:101px" %)**Example**|(% style="width:397px" %)((( 1045 -08 **FF**948 +08 FF 1046 1046 1047 1047 Requests an uplink from LT-22222-L. 1048 1048 ))) ... ... @@ -1049,7 +1049,6 @@ 1049 1049 1050 1050 ==== 3.4.2.4 Enable/Disable Trigger Mode ==== 1051 1051 1052 - 1053 1053 Enable or disable the trigger mode for the current working mode (see also [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]). 1054 1054 1055 1055 (% style="color:#037691" %)**AT Command** ... ... @@ -1077,7 +1077,7 @@ 1077 1077 |(% style="width:97px" %)**Parameters**|(% style="width:401px" %)((( 1078 1078 **prefix** : 0x0A 06 (two bytes in hexadecimal) 1079 1079 1080 -** enable/disable trigger_mode** : enable (1) or disable (0), represented by 1 byte in hexadecimal.982 +**working mode** : enable (1) or disable (0), represented by 1 byte in hexadecimal. 1081 1081 ))) 1082 1082 |(% style="width:97px" %)**Example**|(% style="width:401px" %)((( 1083 1083 0A 06 **01** ... ... @@ -1085,14 +1085,13 @@ 1085 1085 Enable trigger mode for the current working mode 1086 1086 ))) 1087 1087 1088 -==== 3.4.2.5 Requesttrigger settings ====990 +==== 3.4.2.5 Poll trigger settings ==== 1089 1089 992 +Polls the trigger settings. 1090 1090 1091 -Requests the trigger settings. 1092 - 1093 1093 (% style="color:#037691" %)**AT Command:** 1094 1094 1095 -There is no AT Command availablefor this feature.996 +There is no AT Command for this feature. 1096 1096 1097 1097 (% style="color:#037691" %)**Downlink Payload** 1098 1098 ... ... @@ -1107,7 +1107,6 @@ 1107 1107 1108 1108 ==== 3.4.2.6 Enable/Disable DI1/DI2/DI3 as a trigger ==== 1109 1109 1110 - 1111 1111 Enable or disable DI1/DI2/DI3 as a trigger. 1112 1112 1113 1113 (% style="color:#037691" %)**AT Command** ... ... @@ -1162,9 +1162,9 @@ 1162 1162 1163 1163 ==== 3.4.2.7 Trigger1 – Set DI or DI3 as a trigger ==== 1164 1164 1165 - 1166 1166 Sets DI1 or DI3 (for LT-33222-L) as a trigger. 1167 1167 1067 + 1168 1168 (% style="color:#037691" %)**AT Command** 1169 1169 1170 1170 (% border="2" style="width:500px" %) ... ... @@ -1201,9 +1201,9 @@ 1201 1201 1202 1202 ==== 3.4.2.8 Trigger2 – Set DI2 as a trigger ==== 1203 1203 1204 - 1205 1205 Sets DI2 as a trigger. 1206 1206 1106 + 1207 1207 (% style="color:#037691" %)**AT Command** 1208 1208 1209 1209 (% border="2" style="width:500px" %) ... ... @@ -1233,9 +1233,11 @@ 1233 1233 ))) 1234 1234 |(% style="width:96px" %)**Example**|(% style="width:402px" %)09 02 **00 00 64** 1235 1235 1136 +(% class="wikigeneratedid" %) 1137 +==== ==== 1138 + 1236 1236 ==== 3.4.2.9 Trigger – Set AC (current) as a trigger ==== 1237 1237 1238 - 1239 1239 Sets the current trigger based on the AC port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1240 1240 1241 1241 (% style="color:#037691" %)**AT Command** ... ... @@ -1285,7 +1285,6 @@ 1285 1285 1286 1286 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 1287 1287 1288 - 1289 1289 Sets the current trigger based on the AV port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1290 1290 1291 1291 (% style="color:#037691" %)**AT Command** ... ... @@ -1309,6 +1309,7 @@ 1309 1309 ))) 1310 1310 |(% style="width:104px" %)**Note**|(% style="width:387px" %)See also, [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1311 1311 1213 + 1312 1312 (% style="color:#037691" %)**Downlink Payload** 1313 1313 1314 1314 (% border="2" style="width:500px" %) ... ... @@ -1331,9 +1331,9 @@ 1331 1331 ))) 1332 1332 |(% style="width:104px" %)**Note**|(% style="width:394px" %)See also, [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1333 1333 1236 + 1334 1334 ==== 3.4.2.11 Trigger – Set minimum interval ==== 1335 1335 1336 - 1337 1337 Sets the AV and AC trigger minimum interval. The device won't respond to a second trigger within this set time after the first trigger. 1338 1338 1339 1339 (% style="color:#037691" %)**AT Command** ... ... @@ -1367,9 +1367,9 @@ 1367 1367 ))) 1368 1368 |(% style="width:112px" %)Note|(% style="width:386px" %)(% style="color:red" %)**The time must be greater than 5 minutes.** 1369 1369 1272 + 1370 1370 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1371 1371 1372 - 1373 1373 Controls the digital outputs DO1, DO2, and DO3 1374 1374 1375 1375 (% style="color:#037691" %)**AT Command** ... ... @@ -1400,11 +1400,11 @@ 1400 1400 ((( 1401 1401 01: Low, 00: High, 11: No action 1402 1402 1403 -(% border="1" cellspacing=" 3" style="background-color:#f2f2f2; width:383px" %)1404 -|(% style="background-color:#4f81bd; color:white ; width:126px" %)**Downlink Code**|(% style="background-color:#4f81bd; color:white; width:85px" %)**DO1**|(% style="background-color:#4f81bd; color:white; width:86px" %)**DO2**|(% style="background-color:#4f81bd; color:white; width:86px" %)**DO3**1405 -| (% style="width:126px" %)02 01 00 11|(% style="width:85px" %)Low|(% style="width:86px" %)High|(% style="width:86px" %)No Action1406 -| (% style="width:126px" %)02 00 11 01|(% style="width:85px" %)High|(% style="width:86px" %)No Action|(% style="width:86px" %)Low1407 -| (% style="width:126px" %)02 11 01 00|(% style="width:85px" %)No Action|(% style="width:86px" %)Low|(% style="width:86px" %)High1305 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 1306 +|(% style="background-color:#4f81bd; color:white" %)**Downlink Code**|(% style="background-color:#4f81bd; color:white" %)**DO1**|(% style="background-color:#4f81bd; color:white" %)**DO2**|(% style="background-color:#4f81bd; color:white" %)**DO3** 1307 +|02 01 00 11|Low|High|No Action 1308 +|02 00 11 01|High|No Action|Low 1309 +|02 11 01 00|No Action|Low|High 1408 1408 ))) 1409 1409 1410 1410 ((( ... ... @@ -1418,28 +1418,33 @@ 1418 1418 ))) 1419 1419 ))) 1420 1420 1323 +(% class="wikigeneratedid" %) 1324 +==== ==== 1325 + 1421 1421 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1422 1422 1423 1423 1424 1424 * (% style="color:#037691" %)**AT Command** 1425 1425 1426 -There is no AT command to controlthe digitaloutput.1331 +There is no AT Command to control Digital Output 1427 1427 1428 1428 1429 1429 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)** 1430 1430 1431 -(% style="color:blue" %)**0xA9 aa bb cc **(%%) ~/~/ Set sDO1/DO2/DO3 outputswith time control1336 +(% style="color:blue" %)**0xA9 aa bb cc **(%%) ~/~/ Set DO1/DO2/DO3 output with time control 1432 1432 1338 + 1433 1433 This is to control the digital output time of DO pin. Include four bytes: 1434 1434 1435 -(% style="color:#4f81bd" %)**First byte**(%%)**:** Type code (0xA9)1341 +(% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) 1436 1436 1437 -(% style="color:#4f81bd" %)**Second byte**(%%): Inverter Mode1343 +(% style="color:#4f81bd" %)**Second Byte**(%%): Inverter Mode 1438 1438 1439 -**01:** DO pins revert to their original state after the timeout. 1440 -**00:** DO pins switch to an inverted state after the timeout. 1345 +01: DO pins will change back to original state after timeout. 1441 1441 1347 +00: DO pins will change to an inverter state after timeout 1442 1442 1349 + 1443 1443 (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Port status: 1444 1444 1445 1445 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) ... ... @@ -1448,7 +1448,7 @@ 1448 1448 |0x00|DO1 set to high 1449 1449 |0x11|DO1 NO Action 1450 1450 1451 -(% style="color:#4f81bd" %)**Fourth byte**(%%): Control Method and Port status:1358 +(% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Port status: 1452 1452 1453 1453 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1454 1454 |(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status** ... ... @@ -1456,7 +1456,7 @@ 1456 1456 |0x00|DO2 set to high 1457 1457 |0x11|DO2 NO Action 1458 1458 1459 -(% style="color:#4f81bd" %)**Fifth byte**(%%): Control Method and Port status:1366 +(% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Port status: 1460 1460 1461 1461 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1462 1462 |(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status** ... ... @@ -1464,7 +1464,7 @@ 1464 1464 |0x00|DO3 set to high 1465 1465 |0x11|DO3 NO Action 1466 1466 1467 -(% style="color:#4f81bd" %)**Sixth, Seventh, Eighth, and Ninth bytes**:(%%) Latching time (Unit: ms)1374 +(% style="color:#4f81bd" %)**Sixth, Seventh, Eighth, and Ninth Bytes**:(%%) Latching time (Unit: ms) 1468 1468 1469 1469 1470 1470 (% style="color:red" %)**Note: ** ... ... @@ -1473,7 +1473,7 @@ 1473 1473 1474 1474 Before firmware v1.6.0, the latch time only supported 2 bytes. 1475 1475 1476 -(% style="color:red" %)** Thedevice will uplinka packet if the downlink code executes successfully.**1383 +(% style="color:red" %)**Device will upload a packet if the downlink code executes successfully.** 1477 1477 1478 1478 1479 1479 **Example payload:** ... ... @@ -1500,16 +1500,16 @@ 1500 1500 1501 1501 * (% style="color:#037691" %)**AT Command:** 1502 1502 1503 -There is no AT Command to control theRelay Output1410 +There is no AT Command to control Relay Output 1504 1504 1505 1505 1506 1506 * (% style="color:#037691" %)**Downlink Payload (prefix 0x03):** 1507 1507 1508 -(% style="color:blue" %)**0x03 aa bb ** (%%)~/~/ Set sRO1/RO2 output1415 +(% style="color:blue" %)**0x03 aa bb ** (%%)~/~/ Set RO1/RO2 output 1509 1509 1510 1510 1511 1511 ((( 1512 -If thepayload is 0x030100, it means setting RO1 to close and RO2 to open.1419 +If payload is 0x030100, it means setting RO1 to close and RO2 to open. 1513 1513 ))) 1514 1514 1515 1515 ((( ... ... @@ -1527,29 +1527,28 @@ 1527 1527 |03 00 01|Open|Close 1528 1528 ))) 1529 1529 1530 -(% style="color:red" %)** Thedevice will uplinka packet ifthedownlink code executes successfully.**1437 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1531 1531 1532 1532 1533 1533 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1534 1534 1535 - 1536 1536 Controls the relay output time. 1537 1537 1538 1538 * (% style="color:#037691" %)**AT Command:** 1539 1539 1540 -There is no AT Command to control theRelay Output1446 +There is no AT Command to control Relay Output 1541 1541 1542 1542 1543 1543 * (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1544 1544 1545 -(% style="color:blue" %)**0x05 aa bb cc dd ** (%%)~/~/ Set sRO1/RO2 relayswith time control1451 +(% style="color:blue" %)**0x05 aa bb cc dd ** (%%)~/~/ Set RO1/RO2 relay with time control 1546 1546 1547 1547 1548 -This control sthe relay output timeandincludes4bytes:1454 +This is to control the relay output time. It includes four bytes: 1549 1549 1550 -(% style="color:#4f81bd" %)**First byte **(%%)**:** Type code (0x05)1456 +(% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) 1551 1551 1552 -(% style="color:#4f81bd" %)**Second byte1458 +(% style="color:#4f81bd" %)**Second Byte(aa)**(%%): Inverter Mode 1553 1553 1554 1554 01: Relays will change back to their original state after timeout. 1555 1555 ... ... @@ -1556,12 +1556,12 @@ 1556 1556 00: Relays will change to the inverter state after timeout. 1557 1557 1558 1558 1559 -(% style="color:#4f81bd" %)**Third byte1465 +(% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1560 1560 1561 1561 [[image:image-20221008095908-1.png||height="364" width="564"]] 1562 1562 1563 1563 1564 -(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh bytes1470 +(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1565 1565 1566 1566 1567 1567 (% style="color:red" %)**Note:** ... ... @@ -1571,7 +1571,7 @@ 1571 1571 Before firmware v1.6.0, the latch time only supported 2 bytes. 1572 1572 1573 1573 1574 -(% style="color:red" %)** Thedevice will uplinka packet if the downlink code executes successfully.**1480 +(% style="color:red" %)**Device will upload a packet if the downlink code executes successfully.** 1575 1575 1576 1576 1577 1577 **Example payload:** ... ... @@ -1599,395 +1599,159 @@ 1599 1599 1600 1600 When the voltage exceeds the threshold, counting begins. For details, see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1601 1601 1602 -(% style="color:#037691" %)**AT Command** 1508 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+VOLMAX ** (%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1603 1603 1604 -(% border="2" style="width:500px" %) 1605 -|(% style="width:137px" %)**Command**|(% style="width:361px" %)AT+VOLMAX=<voltage>,<logic> 1606 -|(% style="width:137px" %)**Response**|(% style="width:361px" %) 1607 -|(% style="width:137px" %)**Parameters**|(% style="width:361px" %)((( 1608 -**voltage** : voltage threshold in mV 1510 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1609 1609 1610 - **logic**:1512 +(% style="color:blue" %)**0xA5 aa bb cc ** (%%)~/~/ Same as AT+VOLMAX=(aa bb),cc 1611 1611 1612 -**0** : lower than 1613 1613 1614 -**1**: higher than 1615 1615 1616 -if you leave logic parameter blank, it is considered 0 1617 -))) 1618 -|(% style="width:137px" %)**Examples**|(% style="width:361px" %)((( 1619 -AT+VOLMAX=20000 1620 - 1621 -If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1 1622 - 1623 -AT+VOLMAX=20000,0 1624 - 1625 -If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1 1626 - 1627 -AT+VOLMAX=20000,1 1628 - 1629 -If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1 1630 -))) 1631 - 1632 -(% style="color:#037691" %)**Downlink Payload** 1633 - 1634 -(% border="2" style="width:500px" %) 1635 -|(% style="width:140px" %)**Payload**|(% style="width:358px" %)<prefix><voltage><logic> 1636 -|(% style="width:140px" %)**Parameters**|(% style="width:358px" %)((( 1637 -**prefix** : A5 (hex) 1638 - 1639 -**voltage** : voltage threshold in mV (2 bytes in hex) 1640 - 1641 -**logic**: (1 byte in hexadecimal) 1642 - 1643 -**0** : lower than 1644 - 1645 -**1**: higher than 1646 - 1647 -if you leave logic parameter blank, it is considered 1 (higher than) 1648 -))) 1649 -|(% style="width:140px" %)**Example**|(% style="width:358px" %)((( 1650 -A5 **4E 20** 1651 - 1652 -If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1 1653 - 1654 -A5 **4E 20 00** 1655 - 1656 -If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1 1657 - 1658 -A5 **4E 20 01** 1659 - 1660 -If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1 1661 -))) 1662 - 1663 1663 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1664 1664 1665 -This commandallows users to pre-configure specific count numbers for various counting parameters such asCount1,Count2, or AVI1Count. Use the AT command to set the desired count number for each configuration.1518 +This feature allows users to pre-configure specific count numbers for various counting parameters such as count1, count2, or AV1 count. Use the AT command to set the desired count number for each configuration. 1666 1666 1667 -(% style="color:#037691" %)**AT Command** 1520 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) ** 1668 1668 1669 -(% border="2" style="width:500px" %) 1670 -|(% style="width:134px" %)**Command**|(% style="width:364px" %)AT+SETCNT=<counting_parameter>,<number> 1671 -|(% style="width:134px" %)**Response**|(% style="width:364px" %) 1672 -|(% style="width:134px" %)**Parameters**|(% style="width:364px" %)((( 1673 -**counting_parameter** : 1522 +(% style="color:red" %)**aa:**(%%) 1: Set count1; 2: Set count2; 3: Set AV1 count 1674 1674 1675 - 1:COUNT11524 +(% style="color:red" %)**bb cc dd ee: **(%%)The number to be set 1676 1676 1677 -2: COUNT2 1678 1678 1679 - 3:AVI1Count1527 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1680 1680 1681 -**number** : Start number 1682 -))) 1683 -|(% style="width:134px" %)**Example**|(% style="width:364px" %)((( 1684 -AT+SETCNT=1,10 1529 +(% style="color:blue" %)**0x A8 aa bb cc dd ee ** (%%)~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1685 1685 1686 -Sets the COUNT1 to 10. 1687 -))) 1688 1688 1689 -(% style="color:#037691" %)**Downlink Payload** 1690 1690 1691 -(% border="2" style="width:500px" %) 1692 -|(% style="width:135px" %)**Payload**|(% style="width:363px" %)<prefix><counting_parameter><number> 1693 -|(% style="width:135px" %)**Parameters**|(% style="width:363px" %)((( 1694 -prefix : A8 (hex) 1695 - 1696 -**counting_parameter** : (1 byte in hexadecimal) 1697 - 1698 -1: COUNT1 1699 - 1700 -2: COUNT2 1701 - 1702 -3: AVI1 Count 1703 - 1704 -**number** : Start number, 4 bytes in hexadecimal 1705 -))) 1706 -|(% style="width:135px" %)**Example**|(% style="width:363px" %)((( 1707 -A8 **01 00 00 00 0A** 1708 - 1709 -Sets the COUNT1 to 10. 1710 -))) 1711 - 1712 1712 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1713 1713 1714 -This commandclears the counting in counting mode.1535 +This feature clears the counting in counting mode. 1715 1715 1716 -(% style="color:#037691" %)**AT Command** 1537 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+CLRCOUNT **(%%) ~/~/ clear all counting 1717 1717 1718 -(% border="2" style="width:500px" %) 1719 -|(% style="width:142px" %)**Command**|(% style="width:356px" %)AT+CLRCOUNT 1720 -|(% style="width:142px" %)**Response**|(% style="width:356px" %)- 1539 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1721 1721 1722 -(% style="color: #037691" %)**DownlinkPayload**1541 +(% style="color:blue" %)**0x A6 01 ** (%%)~/~/ clear all counting 1723 1723 1724 -(% border="2" style="width:500px" %) 1725 -|(% style="width:141px" %)**Payload**|(% style="width:357px" %)<prefix><clear?> 1726 -|(% style="width:141px" %)**Parameters**|(% style="width:357px" %)((( 1727 -prefix : A6 (hex) 1728 1728 1729 -clear? : 01 (hex) 1730 -))) 1731 -|(% style="width:141px" %)**Example**|(% style="width:357px" %)A6 **01** 1732 1732 1733 -==== 3.4.2.19 Counting ~-~- Set SavingIntervalfor 'CountingResult'====1545 +==== 3.4.2.19 Counting ~-~- Change counting mode to save time ==== 1734 1734 1547 +This feature allows you to configure the device to save its counting result to internal flash memory at specified intervals. By setting a save time, the device will periodically store the counting data to prevent loss in case of power failure. The save interval can be adjusted to suit your requirements, with a minimum value of 30 seconds. 1735 1735 1736 - Thiscommandallowsyouto configure the device to save its counting result to internal flash memoryat specified intervals. By setting a save time, the device will periodically storethe counting data to prevent loss in case of power failure.Thesave interval can be adjusted tosuit your requirements, with aminimum value of 30 seconds.1549 +* (% style="color:#037691" %)**AT Command:** 1737 1737 1738 -(% style="color: #037691" %)**ATommand**1551 +(% style="color:blue" %)**AT+COUTIME=60 **(%%)~/~/ Sets the save time to 60 seconds. The device will save the counting result in internal flash every 60 seconds. (Min value: 30 seconds) 1739 1739 1740 -(% border="2" style="width:500px" %) 1741 -|(% style="width:124px" %)**Command**|(% style="width:374px" %)AT+COUTIME=<time> 1742 -|(% style="width:124px" %)**Response**|(% style="width:374px" %) 1743 -|(% style="width:124px" %)**Parameters**|(% style="width:374px" %)time : seconds (0 to 16777215) 1744 -|(% style="width:124px" %)**Example**|(% style="width:374px" %)((( 1745 -AT+COUTIME=60 1746 1746 1747 -Sets the device to save its counting results to the memory every 60 seconds. 1748 -))) 1554 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1749 1749 1750 -(% style="color: #037691" %)**DownlinkPayload**1556 +(% style="color:blue" %)**0x A7 aa bb cc ** (%%)~/~/ same as AT+COUTIME =aa bb cc, 1751 1751 1752 -(% border="2" style="width:500px" %) 1753 -|(% style="width:123px" %)**Payload**|(% style="width:375px" %)<prefix><time> 1754 -|(% style="width:123px" %)**Parameters**|(% style="width:375px" %)((( 1755 -prefix : A7 1756 - 1757 -time : seconds, 3 bytes in hexadecimal 1558 +((( 1559 +Range: aa bb cc:0 to 16777215, (unit: seconds) 1758 1758 ))) 1759 -|(% style="width:123px" %)**Example**|(% style="width:375px" %)((( 1760 -A7 **00 00 3C** 1761 1761 1762 -Sets the device to save its counting results to the memory every 60 seconds. 1763 -))) 1764 1764 1765 -==== 3.4.2.20 Reset saved RO and DO states ==== 1766 1766 1564 +==== 3.4.2.20 Reset save RO DO state ==== 1767 1767 1768 -This commandallows you to reset the saved relay output (RO) and digital output (DO) states when the device joins the network. By configuring this setting, you can control whether the device should retain or reset the relay states after a reset and rejoin to the network.1566 +This feature allows you to reset the saved relay output (RO) and digital output (DO) states when the device joins the network. By configuring this setting, you can control whether the device should retain or reset the relay states after a reset and rejoin to the network. 1769 1769 1770 -(% style="color:#037691" %)**AT Command** 1568 +* (% style="color:#037691" %)**AT Command:** 1771 1771 1772 -(% border="2" style="width:500px" %) 1773 -|(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+RODORESET=<state> 1774 -|(% style="width:127px" %)**Response**|(% style="width:371px" %) 1775 -|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( 1776 -**state** : 1570 +(% style="color:blue" %)**AT+RODORESET=1 **(%%)~/~/ RODO will close when the device joining the network. (default) 1777 1777 1778 -**0** :RODO willclose when the devicejoins the network.(default)1572 +(% style="color:blue" %)**AT+RODORESET=0 **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state will not change when the device reconnects to the network. 1779 1779 1780 -**1**: After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network. 1781 -))) 1782 -|(% style="width:127px" %)**Example**|(% style="width:371px" %)((( 1783 -(% style="color:blue" %)**AT+RODORESET=1 ** 1784 1784 1785 - RODOwillclosewhenthe device joinsthe network.(default)1575 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** 1786 1786 1787 -(% style="color:blue" %)**AT+RODORE SET=0**1577 +(% style="color:blue" %)**0x AD aa ** (%%)~/~/ same as AT+RODORET =aa 1788 1788 1789 -After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network. 1790 -))) 1791 1791 1792 -(% style="color:#037691" %)**Downlink Payload** 1793 1793 1794 -(% border="2" style="width:500px" %) 1795 -|(% style="width:127px" %)**Payload**|(% style="width:371px" %)<prefix><state> 1796 -|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( 1797 -**prefix** : AD 1798 - 1799 -**state** : 1800 - 1801 -**0** : RODO will close when the device joins the network. (default), represents as 1 byte in hexadecimal. 1802 - 1803 -**1**: After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network. - represents as 1 byte in hexadecimal 1804 -))) 1805 -|(% style="width:127px" %)**Example**|(% style="width:371px" %)((( 1806 -AD **01** 1807 - 1808 -RODO will close when the device joins the network. (default) 1809 - 1810 -AD **00** 1811 - 1812 -After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network. 1813 -))) 1814 - 1815 1815 ==== 3.4.2.21 Encrypted payload ==== 1816 1816 1583 +This feature allows you to configure whether the device should upload data in an encrypted format or in plaintext. By default, the device encrypts the payload before uploading. You can toggle this setting to either upload encrypted data or transmit it without encryption. 1817 1817 1818 - Thiscommandallowsyouto configure whether the device should upload data in an encrypted format or in plaintext. By default, the device encrypts the payload before uploading. You can toggle this setting to eitheruploadencrypted dataor transmit it without encryption.1585 +* (% style="color:#037691" %)**AT Command:** 1819 1819 1820 -(% style="color: #037691" %)**ATmmand:**1587 +(% style="color:blue" %)**AT+DECRYPT=1 ** (%%)~/~/ The payload is uploaded without encryption 1821 1821 1822 -(% border="2" style="width:500px" %) 1823 -|(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+DECRYPT=<state> 1824 -|(% style="width:127px" %)**Response**|(% style="width:371px" %) 1825 -|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( 1826 -**state** : 1589 +(% style="color:blue" %)**AT+DECRYPT=0 **(%%)~/~/ Encrypt when uploading payload (default) 1827 1827 1828 -**1** : The payload is uploaded without encryption 1829 1829 1830 -**0** : The payload is encrypted when uploaded (default) 1831 -))) 1832 -|(% style="width:127px" %)**Example**|(% style="width:371px" %)((( 1833 -AT+DECRYPT=1 1834 1834 1835 -The payload is uploaded without encryption 1836 - 1837 -AT+DECRYPT=0 1838 - 1839 -The payload is encrypted when uploaded (default) 1840 -))) 1841 - 1842 -There is no downlink payload for this configuration. 1843 - 1844 - 1845 1845 ==== 3.4.2.22 Get sensor value ==== 1846 1846 1847 1847 1848 - Thiscommandallowsyouto retrieve and optionallyuplink sensorreadingsthrough the serial port.1596 +* (% style="color:#037691" %)**AT Command:** 1849 1849 1850 -(% style="color: #037691" %)**ATCommand**1598 +(% style="color:blue" %)**AT+GETSENSORVALUE=0 **(%%)~/~/ The serial port retrieves the reading of the current sensor. 1851 1851 1852 -(% border="2" style="width:500px" %) 1853 -|(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+GETSENSORVALUE=<state> 1854 -|(% style="width:127px" %)**Response**|(% style="width:371px" %) 1855 -|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( 1856 -**state** : 1600 +(% style="color:blue" %)**AT+GETSENSORVALUE=1 **(%%)~/~/ The serial port retrieves the current sensor reading and uploads it. 1857 1857 1858 -**0 **: Retrieves the current sensor reading via the serial port. 1859 1859 1860 -**1 **: Retrieves and uploads the current sensor reading via the serial port. 1861 -))) 1862 -|(% style="width:127px" %)**Example**|(% style="width:371px" %)((( 1863 -AT+GETSENSORVALUE=0 1864 1864 1865 -Re trieves thecurrent sensor readingviatheserial port.1604 +==== 3.4.2.23 Resets the downlink packet count ==== 1866 1866 1867 -AT+GETSENSORVALUE=1 1868 1868 1869 -Retrieves and uplinks the current sensor reading via the serial port. 1870 -))) 1607 +* (% style="color:#037691" %)**AT Command:** 1871 1871 1872 -There is no downlink pa yloadfor thisconfiguration.1609 +(% style="color:blue" %)**AT+DISFCNTCHECK=0 **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1873 1873 1611 +(% style="color:blue" %)**AT+DISFCNTCHECK=1 **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count. 1874 1874 1875 -==== 3.4.2.23 Resetting the downlink packet count ==== 1876 1876 1877 1877 1878 -This command manages how the node handles mismatched downlink packet counts. It offers two modes: one disables the reception of further downlink packets if discrepancies occur, while the other resets the downlink packet count to align with the server, ensuring continued communication. 1879 - 1880 -(% style="color:#037691" %)**AT Command** 1881 - 1882 -(% border="2" style="width:500px" %) 1883 -|(% style="width:130px" %)**Command**|(% style="width:368px" %)AT+DISFCNTCHECK=<state> 1884 -|(% style="width:130px" %)**Response**|(% style="width:368px" %)((( 1885 - 1886 -))) 1887 -|(% style="width:130px" %)**Parameters**|(% style="width:368px" %)((( 1888 -**state **: 1889 - 1890 -**0** : When the downlink packet count sent by the server is less than the node's downlink packet count or exceeds 16,384, the node stops receiving further downlink packets (default). 1891 - 1892 - 1893 -**1** : When the downlink packet count sent by the server is less than the node's downlink packet count or exceeds 16,384, the node resets its downlink packet count to match the server's, ensuring consistency. 1894 -))) 1895 -|(% style="width:130px" %)**Example**|(% style="width:368px" %)((( 1896 -AT+DISFCNTCHECK=0 1897 - 1898 -When the downlink packet count sent by the server is less than the node's downlink packet count or exceeds 16,384, the node stops receiving further downlink packets (default). 1899 - 1900 -AT+DISFCNTCHECK=1 1901 - 1902 -When the downlink packet count sent by the server is less than the node's downlink packet count or exceeds 16,384, the node resets its downlink packet count to match the server's, ensuring consistency. 1903 -))) 1904 - 1905 -There is no downlink payload for this configuration. 1906 - 1907 - 1908 1908 ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1909 1909 1910 1910 1911 - Thiscommand controls the behavior of the node when the combined size of the MAC commands(MACANS)from theserver andthe payloadexceeds the allowed bytelimit forthe current data rate (DR).Thecommandprovides two modes:one enables splitting the data into batches to ensure compliance with the byte limit, while the other prioritizes the payload and ignores the MACANS in cases of overflow.1618 +* (% style="color:#037691" %)**AT Command:** 1912 1912 1913 -(% style="color: #037691" %)**AT Command**1620 +(% style="color:blue" %)**AT+DISMACANS=0** (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default) 1914 1914 1915 -(% border="2" style="width:500px" %) 1916 -|(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+DISMACANS=<state> 1917 -|(% style="width:127px" %)**Response**|(% style="width:371px" %) 1918 -|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( 1919 -**state** : 1622 +(% style="color:blue" %)**AT+DISMACANS=1** (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1920 1920 1921 -**0** : When the combined size of the MACANS from the server and the payload exceeds the byte limit (11 bytes for DR0 of US915, DR2 of AS923, DR2 of AU915), the node sends a packet with a payload of 00 and a port of 4. (default) 1922 1922 1923 -**1** : When the combined size of the MACANS from the server and the payload exceeds the byte limit for the current DR, the node ignores the MACANS and only uploads the payload. 1924 -))) 1925 -|(% style="width:127px" %)**Example**|(% style="width:371px" %)((( 1926 -AT+DISMACANS=0 1625 +* (% style="color:#037691" %)**Downlink Payload **(%%)**:** 1927 1927 1928 - Whenthembined sizeof the MACANS from the server and the payloadexceedsthe byte limit (11bytes for DR0of US915,DR2ofAS923,DR2ofAU915),thenodesendsapacketwith a payload of00 anda portof 4. (default)1627 +(% style="color:blue" %)**0x21 00 01 ** (%%) ~/~/ Set the DISMACANS=1 1929 1929 1930 -AT+DISMACANS=1 1931 1931 1932 -When the combined size of the MACANS from the server and the payload exceeds the byte limit for the current DR, the node ignores the MACANS and only uploads the payload. 1933 -))) 1934 1934 1935 -(% style="color:#037691" %)**Downlink Payload** 1936 - 1937 -(% border="2" style="width:500px" %) 1938 -|(% style="width:126px" %)**Payload**|(% style="width:372px" %)<prefix><state> 1939 -|(% style="width:126px" %)**Parameters**|(% style="width:372px" %)((( 1940 -**prefix** : 21 1941 - 1942 -**state** : (2 bytes in hexadecimal) 1943 - 1944 -**0** : When the combined size of the MACANS from the server and the payload exceeds the byte limit (11 bytes for DR0 of US915, DR2 of AS923, DR2 of AU915), the node sends a packet with a payload of 00 and a port of 4. (default) 1945 - 1946 -**1 **: When the combined size of the MACANS from the server and the payload exceeds the byte limit for the current DR, the node ignores the MACANS and only uploads the payload. 1947 -))) 1948 -|(% style="width:126px" %)**Example**|(% style="width:372px" %)((( 1949 -21 **00 01** 1950 - 1951 -Set DISMACANS=1 1952 -))) 1953 - 1954 1954 ==== 3.4.2.25 Copy downlink to uplink ==== 1955 1955 1956 1956 1957 - Thiscommandenableshe device to immediatelyuplink thepayload of a received downlink packet back tothe server.Thecommandallows for quick data replication from downlink to uplink, with a fixed port number of 100.1634 +* (% style="color:#037691" %)**AT Command**(%%)**:** 1958 1958 1959 -(% style="color: #037691" %)**ATCommand**(%%)**:**1636 +(% style="color:blue" %)**AT+RPL=5** (%%) ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100. 1960 1960 1961 - (% style="color:blue" %)**AT+RPL=5**(%%)~/~/Afterreceivingadownlink payloadfromtherver,thedevice will immediately uplinkthe payloadback to the serverusingportnumber100.1638 +Example:**aa xx xx xx xx** ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent. 1962 1962 1963 -Example:**aa xx xx xx xx** ~/~/ **aa** indicates whether the configuration has changed: **00** means YES, and **01** means NO. **xx xx xx xx** are the bytes uplinked back. 1964 1964 1965 - 1966 1966 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]] 1967 1967 1968 1968 For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77. 1969 1969 1645 + 1646 + 1970 1970 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]] 1971 1971 1972 1972 For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned. 1973 1973 1974 1974 1975 -(% style="color:#037691" %)**Downlink Payload**(%%)**:** 1976 1976 1977 - Thereisno downlinkoptionavailableforthisfeature.1653 +==== 3.4.2.26 Query version number and frequency band 、TDC ==== 1978 1978 1979 1979 1980 -==== 3.4.2.26 Query firmware version, frequency band, sub band, and TDC time ==== 1981 - 1982 - 1983 -This command is used to query key information about the device, including its firmware version, frequency band, sub band, and TDC time. By sending the specified payload as a downlink, the server can retrieve this essential data from the device. 1984 - 1985 1985 * ((( 1986 1986 (% style="color:#037691" %)**Downlink Payload**(%%)**:** 1987 1987 1988 -(% style="color:blue" %)**26 01 ** (%%) ~/~/ The downlinkpayload26 01isusedtoquerythedevice'sfirmwareversion, frequency band, sub band,andTDC time.1659 +(% style="color:blue" %)**26 01 ** (%%) ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time. 1989 1989 1990 - 1991 1991 1992 1992 ))) 1993 1993 ... ... @@ -1998,13 +1998,10 @@ 1998 1998 1999 1999 == 3.5 Integrating with ThingsEye.io == 2000 2000 2001 - 2002 2002 The Things Stack application supports integration with ThingsEye.io. Once integrated, ThingsEye.io acts as an MQTT client for The Things Stack MQTT broker, allowing it to subscribe to upstream traffic and publish downlink traffic. 2003 2003 2004 - 2005 2005 === 3.5.1 Configuring The Things Stack === 2006 2006 2007 - 2008 2008 We use The Things Stack Sandbox in this example: 2009 2009 2010 2010 * In **The Things Stack Sandbox**, go to the **Application **for the LT-22222-L you added. ... ... @@ -2016,19 +2016,15 @@ 2016 2016 The username and password (API key) you created here are required in the next section. 2017 2017 {{/info}} 2018 2018 2019 -[[image:tts-mqtt-integration.png]] 1686 +[[image:tts-mqtt-integration.png||height="625" width="1000"]] 2020 2020 2021 - 2022 2022 === 3.5.2 Configuring ThingsEye.io === 2023 2023 2024 - 2025 -The ThingsEye.io IoT platform is not open for self-registration at the moment. If you are interested in testing the platform, please send your project information to admin@thingseye.io, and we will create an account for you. 2026 - 2027 2027 * Login to your [[ThingsEye.io >>https://thingseye.io]]account. 2028 2028 * Under the **Integrations center**, click **Integrations**. 2029 2029 * Click the **Add integration** button (the button with the **+** symbol). 2030 2030 2031 -[[image:thingseye-io-step-1.png]] 1694 +[[image:thingseye-io-step-1.png||height="625" width="1000"]] 2032 2032 2033 2033 2034 2034 On the **Add integration** window, configure the following: ... ... @@ -2043,7 +2043,7 @@ 2043 2043 ** Allow create devices or assets 2044 2044 * Click the **Next** button. you will be navigated to the **Uplink data converter** tab. 2045 2045 2046 -[[image:thingseye-io-step-2.png]] 1709 +[[image:thingseye-io-step-2.png||height="625" width="1000"]] 2047 2047 2048 2048 2049 2049 **Uplink data converter:** ... ... @@ -2054,7 +2054,7 @@ 2054 2054 * Paste the uplink decoder function into the text area (first, delete the default code). The demo uplink decoder function can be found [[here>>https://raw.githubusercontent.com/ThingsEye-io/te-platform/refs/heads/main/Data%20Converters/The_Things_Network_MQTT_Uplink_Converter.js]]. 2055 2055 * Click the **Next** button. You will be navigated to the **Downlink data converter **tab. 2056 2056 2057 -[[image:thingseye-io-step-3.png]] 1720 +[[image:thingseye-io-step-3.png||height="625" width="1000"]] 2058 2058 2059 2059 2060 2060 **Downlink data converter (this is an optional step):** ... ... @@ -2065,7 +2065,7 @@ 2065 2065 * Paste the downlink decoder function into the text area (first, delete the default code). The demo downlink decoder function can be found [[here>>https://raw.githubusercontent.com/ThingsEye-io/te-platform/refs/heads/main/Data%20Converters/The_Things_Network_MQTT_Downlink_Converter.js]]. 2066 2066 * Click the **Next** button. You will be navigated to the **Connection** tab. 2067 2067 2068 -[[image:thingseye-io-step-4.png]] 1731 +[[image:thingseye-io-step-4.png||height="625" width="1000"]] 2069 2069 2070 2070 2071 2071 **Connection:** ... ... @@ -2072,7 +2072,7 @@ 2072 2072 2073 2073 * Choose **Region** from the **Host type**. 2074 2074 * Enter the **cluster** of your **The Things Stack** in the **Region** textbox. You can find the cluster in the url (e.g., https:~/~/**eu1**.cloud.thethings.network/...). 2075 -* Enter the **Username** and **Password** of the MQTT integration in the **Credentials** section. The **username **and **password **can be found on the MQTT integration page of your The Things Stack account (see **3.5.1Configuring The Things Stack**).1738 +* Enter the **Username** and **Password** of the MQTT integration in the **Credentials** section. The **username **and **password **can be found on the MQTT integration page of your The Things Stack account (see Configuring The Things Stack). 2076 2076 * Click the **Check connection** button to test the connection. If the connection is successful, you will see the message saying **Connected**. 2077 2077 2078 2078 [[image:message-1.png]] ... ... @@ -2080,64 +2080,54 @@ 2080 2080 2081 2081 * Click the **Add** button. 2082 2082 2083 -[[image:thingseye-io-step-5.png]] 1746 +[[image:thingseye-io-step-5.png||height="625" width="1000"]] 2084 2084 2085 2085 2086 -Your integration has been added to the** Integrations** list and will be displayed on the **Integrations** page. Check whether the status is shown as **Active**. If not, review your configuration settings and correct any errors.1749 +Your integration has been added to the** Integrations** list and will be displayed on the **Integrations** page. Check whether the status is shown as **Active**. If not, review your configuration settings. 2087 2087 2088 2088 2089 -[[image:thingseye.io_integrationsCenter_integrations.png]] 1752 +[[image:thingseye.io_integrationsCenter_integrations.png||height="686" width="1000"]] 2090 2090 2091 2091 2092 2092 ==== 3.5.2.1 Viewing integration details ==== 2093 2093 2094 - 2095 2095 Click on your integration from the list. The **Integration details** window will appear with the **Details **tab selected. The **Details **tab shows all the settings you have provided for this integration. 2096 2096 2097 -[[image:integration-details.png]] 1759 +[[image:integration-details.png||height="686" width="1000"]] 2098 2098 2099 2099 2100 2100 If you want to edit the settings you have provided, click on the **Toggle edit mode** button. Once you have done click on the **Apply changes **button. 2101 2101 2102 2102 {{info}} 2103 -See also [[ThingsEye documentation>>https://wiki.thingseye.io/xwiki/bin/view/Main/]].1765 +See also ThingsEye documentation. 2104 2104 {{/info}} 2105 2105 1768 +==== **3.5.2.2 Viewing events** ==== 2106 2106 2107 -==== 3.5.2.2 Viewing events ==== 2108 - 2109 - 2110 2110 The **Events **tab displays all the uplink messages from the LT-22222-L. 2111 2111 2112 2112 * Select **Debug **from the **Event type** dropdown. 2113 2113 * Select the** time frame** from the **time window**. 2114 2114 2115 -[[image:thingseye-events.png]] 1775 +[[image:thingseye-events.png||height="686" width="1000"]] 2116 2116 2117 2117 2118 -* To view the **JSON payload**of a message, click on the**three dots (...)**in the Message column of the desired message.1778 +* To view the JSON payload of a message, click on the three dots (...) in the Message column of the desired message. 2119 2119 2120 -[[image:thingseye-json.png]] 1780 +[[image:thingseye-json.png||width="1000"]] 2121 2121 2122 2122 2123 -==== 3.5.2.3 Deleting an integration ==== 1783 +==== **3.5.2.3 Deleting an integration** ==== 2124 2124 2125 - 2126 2126 If you want to delete an integration, click the **Delete integratio**n button on the Integrations page. 2127 2127 2128 2128 2129 -==== 3.5.2.4 Creating a Dashboard to Display and Analyze LT-22222-L Data ==== 2130 - 2131 - 2132 -This will be added soon. 2133 - 2134 - 2135 2135 == 3.6 Interface Details == 2136 2136 2137 2137 === 3.6.1 Digital Input Ports: DI1/DI2/DI3 (For LT-33222-L, Low Active) === 2138 2138 2139 2139 2140 -Supports **NPN-type**sensors.1793 +Supports NPN-type sensors. 2141 2141 2142 2142 [[image:1653356991268-289.png]] 2143 2143 ... ... @@ -2259,15 +2259,15 @@ 2259 2259 ))) 2260 2260 2261 2261 2262 -(% style="color:blue" %)**Example aDry Contact sensor1915 +(% style="color:blue" %)**Example4**(%%): Connecting to Dry Contact sensor 2263 2263 2264 -From the DI port circuit above, activating the photocoupler requires a voltage difference between the DI+ and DI- ports. However, the Dry Contact sensor is a passive component and cannot provide this voltage difference on its own.1917 +From the DI port circuit above, you can see that activating the photocoupler requires a voltage difference between the DI+ and DI- ports. However, the Dry Contact sensor is a passive component and cannot provide this voltage difference. 2265 2265 2266 -To detect a Dry Contact, you can supply a power source to one of thepinsof the Dry Contact.Areference circuit diagramis shown below.1919 +To detect a Dry Contact, you can supply a power source to one pin of the Dry Contact. Below is a reference circuit diagram. 2267 2267 2268 2268 [[image:image-20230616235145-1.png]] 2269 2269 2270 -(% style="color:blue" %)**Example 1923 +(% style="color:blue" %)**Example5**(%%): Connecting to an Open Collector 2271 2271 2272 2272 [[image:image-20240219115718-1.png]] 2273 2273 ... ... @@ -2343,9 +2343,8 @@ 2343 2343 [[image:image-20220524100215-10.png||height="382" width="723"]] 2344 2344 2345 2345 2346 -== 3.7 LED Indicators == 1999 +== 3.7 LEDs Indicators == 2347 2347 2348 - 2349 2349 The table below lists the behavior of LED indicators for each port function. 2350 2350 2351 2351 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) ... ... @@ -2378,22 +2378,18 @@ 2378 2378 2379 2379 = 4. Using AT Commands = 2380 2380 2381 - 2382 2382 The LT-22222-L supports programming using AT Commands. 2383 2383 2384 - 2385 2385 == 4.1 Connecting the LT-22222-L to a PC == 2386 2386 2387 - 2388 2388 ((( 2389 -You can use a USB-to-TTL adapter /converteralong with a 3.5mm Program Cable to connect the LT-22222-L to a PC, as shown below.2038 +You can use a USB-to-TTL adapter along with a 3.5mm Program Cable to connect the LT-22222-L to a PC, as shown below. 2390 2390 2391 -[[image:usb-ttl-audio-jack-connection.jpg]] 2392 - 2393 - 2040 +[[image:usb-ttl-programming.png]] 2394 2394 ))) 2395 2395 2396 2396 2044 + 2397 2397 ((( 2398 2398 On the PC, you need to set the (% style="color:#4f81bd" %)**serial tool **(%%)(such as [[PuTTY>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]] or [[SecureCRT>>https://www.vandyke.com/cgi-bin/releases.php?product=securecrt]]) to a baud rate of (% style="color:green" %)**9600**(%%) to access the serial console of LT-22222-L. Access to AT commands is disabled by default, and a password (default: (% style="color:green" %)**123456**)(%%) must be entered to enable AT command access, as shown below: 2399 2399 ))) ... ... @@ -2404,10 +2404,7 @@ 2404 2404 ((( 2405 2405 You can find more details in the [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 2406 2406 2407 - 2408 2408 == 4.2 LT-22222-L related AT commands == 2409 - 2410 - 2411 2411 ))) 2412 2412 2413 2413 ((( ... ... @@ -2426,39 +2426,39 @@ 2426 2426 * **##AT+APPSKEY##**: Get or set the Application Session Key (AppSKey) 2427 2427 * **##AT+APPEUI##**: Get or set the Application EUI (AppEUI) 2428 2428 * **##AT+ADR##**: Get or set the Adaptive Data Rate setting. (0: OFF, 1: ON) 2429 -* ##**AT+TXP**##: Get or set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Specification)2430 -* **##AT+DR##**: Get or set the Data Rate. (0-7 corresponding to DR_X)2431 -* **##AT+DCS##**: Get or set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing2432 -* ##**AT+PNM**##: Get or set the public network mode. (0: off, 1: on)2433 -* ##**AT+RX2FQ**##: Get or set the Rx2 window frequency2434 -* ##**AT+RX2DR**##: Get or set the Rx2 window data rate (0-7 corresponding to DR_X)2435 -* ##**AT+RX1DL**##: Get or set the delay between the end of the Tx and the Rx Window 1 in ms2436 -* ##**AT+RX2DL**##: Get or set the delay between the end of the Tx and the Rx Window 2 in ms2437 -* ##**AT+JN1DL**##: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms2438 -* ##**AT+JN2DL**##: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms2439 -* ##**AT+NJM**##: Get or set the Network Join Mode. (0: ABP, 1: OTAA)2440 -* ##**AT+NWKID**##: Get or set the Network ID2441 -* ##**AT+FCU**##: Get or set the Frame Counter Uplink (FCntUp)2442 -* ##**AT+FCD**##: Get or set the Frame Counter Downlink (FCntDown)2443 -* ##**AT+CLASS**##: Get or set the Device Class2444 -* ##**AT+JOIN**##: Join network2445 -* ##**AT+NJS**##: Get OTAA Join Status2446 -* ##**AT+SENDB**##: Send hexadecimal data along with the application port2447 -* ##**AT+SEND**##: Send text data along with the application port2448 -* ##**AT+RECVB**##: Print last received data in binary format (with hexadecimal values)2449 -* ##**AT+RECV**##: Print last received data in raw format2450 -* ##**AT+VER**##: Get current image version and Frequency Band2451 -* ##**AT+CFM**##: Get or Set the confirmation mode (0-1)2452 -* ##**AT+CFS**##: Get confirmation status of the last AT+SEND (0-1)2453 -* ##**AT+SNR**##: Get the SNR of the last received packet2454 -* ##**AT+RSSI**##: Get the RSSI of the last received packet2455 -* ##**AT+TDC**##: Get or set the application data transmission interval in ms2456 -* ##**AT+PORT**##: Get or set the application port2457 -* ##**AT+DISAT**##: Disable AT commands2458 -* ##**AT+PWORD**##: Set password, max 9 digits2459 -* ##**AT+CHS**##: Get or set the Frequency (Unit: Hz) for Single Channel Mode2460 -* ##**AT+CHE**##: Get or set eight channels mode, Only for US915, AU915, CN4702461 -* ##**AT+CFG**##: Print all settings2074 +* AT+TXP: Get or set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Specification) 2075 +* AT+DR: Get or set the Data Rate. (0-7 corresponding to DR_X) 2076 +* AT+DCS: Get or set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 2077 +* AT+PNM: Get or set the public network mode. (0: off, 1: on) 2078 +* AT+RX2FQ: Get or set the Rx2 window frequency 2079 +* AT+RX2DR: Get or set the Rx2 window data rate (0-7 corresponding to DR_X) 2080 +* AT+RX1DL: Get or set the delay between the end of the Tx and the Rx Window 1 in ms 2081 +* AT+RX2DL: Get or set the delay between the end of the Tx and the Rx Window 2 in ms 2082 +* AT+JN1DL: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 2083 +* AT+JN2DL: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 2084 +* AT+NJM: Get or set the Network Join Mode. (0: ABP, 1: OTAA) 2085 +* AT+NWKID: Get or set the Network ID 2086 +* AT+FCU: Get or set the Frame Counter Uplink (FCntUp) 2087 +* AT+FCD: Get or set the Frame Counter Downlink (FCntDown) 2088 +* AT+CLASS: Get or set the Device Class 2089 +* AT+JOIN: Join network 2090 +* AT+NJS: Get OTAA Join Status 2091 +* AT+SENDB: Send hexadecimal data along with the application port 2092 +* AT+SEND: Send text data along with the application port 2093 +* AT+RECVB: Print last received data in binary format (with hexadecimal values) 2094 +* AT+RECV: Print last received data in raw format 2095 +* AT+VER: Get current image version and Frequency Band 2096 +* AT+CFM: Get or Set the confirmation mode (0-1) 2097 +* AT+CFS: Get confirmation status of the last AT+SEND (0-1) 2098 +* AT+SNR: Get the SNR of the last received packet 2099 +* AT+RSSI: Get the RSSI of the last received packet 2100 +* AT+TDC: Get or set the application data transmission interval in ms 2101 +* AT+PORT: Get or set the application port 2102 +* AT+DISAT: Disable AT commands 2103 +* AT+PWORD: Set password, max 9 digits 2104 +* AT+CHS: Get or set the Frequency (Unit: Hz) for Single Channel Mode 2105 +* AT+CHE: Get or set eight channels mode, Only for US915, AU915, CN470 2106 +* AT+CFG: Print all settings 2462 2462 ))) 2463 2463 2464 2464 ... ... @@ -2604,19 +2604,16 @@ 2604 2604 2605 2605 == 5.1 Counting how many objects pass through the flow line == 2606 2606 2607 - 2608 2608 See [[How to set up to setup counting for objects passing through the flow line>>How to set up to count objects pass in flow line]]? 2609 2609 2610 2610 2611 2611 = 6. FAQ = 2612 2612 2613 - 2614 2614 This section contains some frequently asked questions, which can help you resolve common issues and find solutions quickly. 2615 2615 2616 2616 2617 2617 == 6.1 How to update the firmware? == 2618 2618 2619 - 2620 2620 Dragino frequently releases firmware updates for the LT-22222-L. Updating your LT-22222-L with the latest firmware version helps to: 2621 2621 2622 2622 * Support new features ... ... @@ -2626,7 +2626,7 @@ 2626 2626 You will need the following things before proceeding: 2627 2627 2628 2628 * 3.5mm programming cable (included with the LT-22222-L as an additional accessory) 2629 -* USB to TTL adapter /converter2271 +* USB to TTL adapter 2630 2630 * Download and install the [[STM32 Flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. (replaced by STM32CubeProgrammer) 2631 2631 * Download the latest firmware image from [[LT-22222-L firmware image files>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AACrbrDN0AqLHbBat0ViWx5Da/LT-22222-L/Firmware?dl=0&subfolder_nav_tracking=1]]. Check the file name of the firmware to find the correct region. 2632 2632 ... ... @@ -2636,7 +2636,7 @@ 2636 2636 2637 2637 Below is the hardware setup for uploading a firmware image to the LT-22222-L: 2638 2638 2639 -[[image:usb-ttl- audio-jack-connection.jpg]]2281 +[[image:usb-ttl-programming.png]] 2640 2640 2641 2641 2642 2642 ... ... @@ -2669,8 +2669,6 @@ 2669 2669 ((( 2670 2670 ((( 2671 2671 == 6.2 How to change the LoRaWAN frequency band/region? == 2672 - 2673 - 2674 2674 ))) 2675 2675 ))) 2676 2676 ... ... @@ -2682,8 +2682,6 @@ 2682 2682 2683 2683 2684 2684 == 6.3 How to setup LT-22222-L to work with a Single Channel Gateway, such as LG01/LG02? == 2685 - 2686 - 2687 2687 ))) 2688 2688 2689 2689 ((( ... ... @@ -2757,13 +2757,11 @@ 2757 2757 2758 2758 == 6.4 How to change the uplink interval? == 2759 2759 2760 - 2761 2761 Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]] 2762 2762 2763 2763 2764 2764 == 6.5 Can I see the counting event in the serial output? == 2765 2765 2766 - 2767 2767 ((( 2768 2768 You can run the AT command **AT+DEBUG** to view the counting event in the serial output. If the firmware is too old and doesn’t support AT+DEBUG, update to the latest firmware first. 2769 2769 ... ... @@ -2770,7 +2770,6 @@ 2770 2770 2771 2771 == 6.6 Can I use point-to-point communication with LT-22222-L? == 2772 2772 2773 - 2774 2774 Yes, you can. Please refer to the [[Point-to-Point Communication of LT-22222-L>>https://wiki.dragino.com/xwiki/bin/view/Main/%20Point%20to%20Point%20Communication%20of%20LT-22222-L/]] page. The firmware that supports point-to-point communication can be found [[here>>https://github.com/dragino/LT-22222-L/releases]]. 2775 2775 2776 2776 ... ... @@ -2779,7 +2779,6 @@ 2779 2779 ((( 2780 2780 == 6.7 Why does the relay output default to an open relay after the LT-22222-L is powered off? == 2781 2781 2782 - 2783 2783 * If the device is not properly shut down and is directly powered off. 2784 2784 * It will default to a power-off state. 2785 2785 * In modes 2 to 5, the DO/RO status and pulse count are saved to flash memory. ... ... @@ -2787,7 +2787,6 @@ 2787 2787 2788 2788 == 6.8 Can I setup LT-22222-L as a NC (Normally Closed) relay? == 2789 2789 2790 - 2791 2791 The LT-22222-L's built-in relay is Normally Open (NO). You can use an external relay to achieve a Normally Closed (NC) configuration. The circuit diagram is shown below: 2792 2792 2793 2793 ... ... @@ -2796,19 +2796,16 @@ 2796 2796 2797 2797 == 6.9 Can the LT-22222-L save the RO state? == 2798 2798 2799 - 2800 2800 To enable this feature, the firmware version must be 1.6.0 or higher. 2801 2801 2802 2802 2803 2803 == 6.10 Why does the LT-22222-L always report 15.585V when measuring the AVI? == 2804 2804 2805 - 2806 2806 It is likely that the GND is not connected during the measurement, or that the wire connected to the GND is loose. 2807 2807 2808 2808 2809 2809 = 7. Troubleshooting = 2810 2810 2811 - 2812 2812 This section provides some known troubleshooting tips. 2813 2813 2814 2814 ... ... @@ -2817,8 +2817,6 @@ 2817 2817 ((( 2818 2818 ((( 2819 2819 == 7.1 Downlink isn't working. How can I solve this? == 2820 - 2821 - 2822 2822 ))) 2823 2823 ))) 2824 2824 ... ... @@ -2830,8 +2830,6 @@ 2830 2830 2831 2831 2832 2832 == 7.2 Having trouble uploading an image? == 2833 - 2834 - 2835 2835 ))) 2836 2836 2837 2837 ((( ... ... @@ -2842,8 +2842,6 @@ 2842 2842 2843 2843 2844 2844 == 7.3 Why can't I join TTN in the US915 /AU915 bands? == 2845 - 2846 - 2847 2847 ))) 2848 2848 2849 2849 ((( ... ... @@ -2853,7 +2853,6 @@ 2853 2853 2854 2854 == 7.4 Why can the LT-22222-L perform uplink normally, but cannot receive downlink? == 2855 2855 2856 - 2857 2857 The FCD count of the gateway is inconsistent with the FCD count of the node, causing the downlink to remain in the queue. 2858 2858 Use this command to synchronize their counts: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resetsthedownlinkpacketcount"]] 2859 2859 ... ... @@ -2860,7 +2860,6 @@ 2860 2860 2861 2861 = 8. Ordering information = 2862 2862 2863 - 2864 2864 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 2865 2865 2866 2866 (% style="color:#4f81bd" %)**XXX:** ... ... @@ -2877,7 +2877,6 @@ 2877 2877 2878 2878 = 9. Package information = 2879 2879 2880 - 2881 2881 **Package includes**: 2882 2882 2883 2883 * 1 x LT-22222-L I/O Controller ... ... @@ -2894,7 +2894,6 @@ 2894 2894 2895 2895 = 10. Support = 2896 2896 2897 - 2898 2898 * ((( 2899 2899 Support is available Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different time zones, we cannot offer live support. However, your questions will be answered as soon as possible within the aforementioned schedule. 2900 2900 ))) ... ... @@ -2906,7 +2906,6 @@ 2906 2906 2907 2907 = 11. Reference = 2908 2908 2909 - 2910 2910 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2911 2911 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2912 2912 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
- Screenshot 2024-11-23 at 18.27.11.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.pradeeka - Size
-
... ... @@ -1,1 +1,0 @@ 1 -143.4 KB - Content
- Screenshot 2024-12-08 193946.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.pradeeka - Size
-
... ... @@ -1,1 +1,0 @@ 1 -32.4 KB - Content
- dragino-lorawan-nw-lt-22222-n.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.pradeeka - Size
-
... ... @@ -1,1 +1,0 @@ 1 -267.3 KB - Content
- dragino-ttn-te.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.pradeeka - Size
-
... ... @@ -1,1 +1,0 @@ 1 -273.8 KB - Content
- lorawan-nw.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.pradeeka - Size
-
... ... @@ -1,1 +1,0 @@ 1 -250.6 KB - Content
- lt-22222-l-joining.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.pradeeka - Size
-
... ... @@ -1,1 +1,0 @@ 1 -301.9 KB - Content
- lt-22222-l-js-custom-payload-formatter.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.pradeeka - Size
-
... ... @@ -1,1 +1,0 @@ 1 -453.9 KB - Content
- lt33222-l.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.pradeeka - Size
-
... ... @@ -1,1 +1,0 @@ 1 -31.3 KB - Content
- usb-ttl-audio-jack-connection.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.pradeeka - Size
-
... ... @@ -1,1 +1,0 @@ 1 -394.4 KB - Content