... ... @@ -4,13 +4,8 @@ 4 4 **LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 -**Table of Contents:** 8 8 9 -{{toc/}} 10 10 11 - 12 - 13 - 14 14 = 1.Introduction = 15 15 16 16 == 1.1 What is LT Series I/O Controller == ... ... @@ -187,9 +187,7 @@ 187 187 188 188 [[image:image-20220523174024-3.png]] 189 189 190 -((( 191 191 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 192 -))) 193 193 194 194 [[image:image-20220523174254-4.png]] 195 195 ... ... @@ -237,188 +237,229 @@ 237 237 238 238 Total : 11 bytes payload 239 239 240 -[[image:image-20220523180452-3.png]] 233 +(% border="1" style="background-color:#f7faff; height:10px; width:500px" %) 234 +|Size(bytes)|4|4|1|1|1 235 +|Value|COUNT1|COUNT2 |DIDORO*|((( 236 +Reserve 241 241 242 -((( 243 -(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 244 -))) 238 + 239 +)))|MOD 245 245 246 - [[image:image-20220523180506-4.png]]241 +**DIDORO** is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 247 247 243 +(% border="1" style="background-color:#f7faff; width:500px" %) 244 +|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 245 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 246 + 248 248 * RO is for relay. ROx=1 : close,ROx=0 always open. 249 249 * FIRST: Indicate this is the first packet after join network. 250 250 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 251 251 252 - (% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L.251 +Note: DO3 bit is not valid for LT-22222-L. 253 253 254 -**To use counting mode, please run:** 255 255 256 -(% class="box infomessage" %) 257 -((( 258 -**AT+MOD=2** 259 -))) 254 +To use counting mode, please run: 260 260 261 -(% class="box infomessage" %) 262 -((( 263 -**ATZ** 264 -))) 256 +AT+MOD=2 265 265 266 - (% style="color:#4f81bd" %)**ATCommands for counting:**258 +ATZ 267 267 260 + 261 +AT Commands for counting: 262 + 263 +**For LT33222-L:** 264 + 265 +AT+TRIG1=0,100 (set DI3 port to trigger on low level, valid signal is 100ms) 266 + 267 +AT+TRIG1=1,100 (set DI3 port to trigger on high level, valid signal is 100ms ) 268 + 269 +AT+SETCNT=1,60 (Set COUNT1 value to 60) 270 + 271 + 268 268 **For LT22222-L:** 269 269 270 -(% class="box infomessage" %) 271 -((( 272 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 273 -))) 274 +AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) 274 274 275 -(% class="box infomessage" %) 276 -((( 277 -**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 278 -))) 276 +AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 279 279 280 -(% class="box infomessage" %) 281 -((( 282 -**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 283 -))) 278 +AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) 284 284 285 -(% class="box infomessage" %) 286 -((( 287 -**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 288 -))) 280 +AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) 289 289 290 -(% class="box infomessage" %) 291 -((( 292 -**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 293 -))) 294 294 295 -(% class="box infomessage" %) 296 -((( 297 -**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 298 -))) 283 +AT+SETCNT=1,60 (Set COUNT1 value to 60) 299 299 300 - === 3.3.3AT+MOD~=3, SingleDI Counting+2xACI===285 +AT+SETCNT=2,60 (Set COUNT2 value to 60) 301 301 287 + 288 +**For both LT22222-L & LT33222-L**: 289 + 290 +AT+CLRCOUNT clear all countings 291 + 292 +AT+COUTIME=60 Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 293 + 294 + 295 + 296 +1. 297 +11. 298 +111. AT+MOD=3, Single DI Counting + 2 x ACI 299 + 300 +**LT33222-L**: This mode the DI3 is used as a counting pin. 301 + 302 302 **LT22222-L**: This mode the DI1 is used as a counting pin. 303 303 304 -[[image:image-20220523181246-5.png]] 305 305 306 -((( 307 -(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 308 -))) 305 +(% border="1" style="background-color:#f7faff" %) 306 +|Size(bytes)|4|2|2|1|1|1 307 +|Value|COUNT1|((( 308 +ACI1 309 309 310 -[[image:image-20220523181301-6.png]] 310 +Current 311 +)))|((( 312 +ACI2 311 311 314 +Current 315 +)))|DIDORO*|Reserve|MOD 316 + 317 +**DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 318 + 319 +(% border="1" style="background-color:#f7faff" %) 320 +|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 321 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 322 + 312 312 * RO is for relay. ROx=1 : close,ROx=0 always open. 313 313 * FIRST: Indicate this is the first packet after join network. 314 314 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 315 315 316 - (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.327 +Note: DO3 is not valid for LT-22222-L. 317 317 318 -**To use counting mode, please run:** 319 319 320 -(% class="box infomessage" %) 321 -((( 322 -**AT+MOD=3** 323 -))) 330 +To use counting mode, please run: 324 324 325 -(% class="box infomessage" %) 326 -((( 327 -**ATZ** 328 -))) 332 +AT+MOD=3 329 329 334 +ATZ 335 + 336 + 330 330 Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:#COUNT_COMMAND]]. 331 331 332 -=== 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 333 333 340 + 341 + 342 +1. 343 +11. 344 +111. AT+MOD=4, Single DI Counting + 1 x Voltage Counting 345 + 346 +**LT33222-L**: This mode the DI3 is used as a counting pin. 347 + 334 334 **LT22222-L**: This mode the DI1 is used as a counting pin. 335 335 350 + 336 336 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. 337 337 338 -[[image:image-20220523181903-8.png]] 339 339 340 -((( 341 -(% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 342 -))) 354 +(% border="1" style="background-color:#f7faff" %) 355 +|Size(bytes)|4|4|1|1|1 356 +|Value|COUNT1|AVI1 Counting|DIDORO*|((( 357 +Reserve 343 343 344 -[[image:image-20220523181727-7.png]] 359 + 360 +)))|MOD 345 345 362 +**DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 363 + 364 +(% border="1" style="background-color:#f7faff" %) 365 +|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 366 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 367 + 346 346 * RO is for relay. ROx=1 : close,ROx=0 always open. 347 347 * FIRST: Indicate this is the first packet after join network. 348 348 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 349 349 350 - (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.372 +Note: DO3 is not valid for LT-22222-L. 351 351 352 -**To use this mode, please run:** 353 353 354 -(% class="box infomessage" %) 355 -((( 356 -**AT+MOD=4** 357 -))) 375 +To use this mode, please run: 358 358 359 -(% class="box infomessage" %) 360 -((( 361 -**ATZ** 362 -))) 377 +AT+MOD=4 363 363 379 +ATZ 364 364 381 + 382 + 365 365 Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:#COUNT_COMMAND]]. 366 366 367 - **Plus below command for AVI1 Counting:**385 +Plus below command for AVI1 Counting: 368 368 369 -(% class="box infomessage" %) 370 -((( 371 -**AT+SETCNT=3,60 (set AVI Count to 60)** 372 -))) 387 +AT+SETCNT=3,60 (set AVI Count to 60) 373 373 374 -(% class="box infomessage" %) 375 -((( 376 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 377 -))) 389 +AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1) 378 378 379 -(% class="box infomessage" %) 380 -((( 381 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 382 -))) 391 +AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1) 383 383 384 -(% class="box infomessage" %) 385 -((( 386 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 387 -))) 393 +AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1) 388 388 389 -=== 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 390 390 396 + 397 +1. 398 +11. 399 +111. AT+MOD=5, Single DI Counting + 2 x AVI + 1 x ACI 400 + 401 +**LT33222-L**: This mode the DI3 is used as a counting pin. 402 + 391 391 **LT22222-L**: This mode the DI1 is used as a counting pin. 392 392 393 -[[image:image-20220523182334-9.png]] 394 394 395 -((( 396 -(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 397 -))) 406 +(% border="1" style="background-color:#f7faff" %) 407 +|Size(bytes)|2|2|2|2|1|1|1 408 +|Value|((( 409 +AVI1 398 398 411 +voltage 412 +)))|((( 413 +AVI2 399 399 415 +voltage 416 +)))|((( 417 +ACI1 418 + 419 +Current 420 +)))|COUNT1|DIDORO*|((( 421 +Reserve 422 + 423 + 424 +)))|MOD 425 + 426 +**DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 427 + 428 +(% border="1" style="background-color:#f7faff" %) 429 +|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 430 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 431 + 400 400 * RO is for relay. ROx=1 : close,ROx=0 always open. 401 401 * FIRST: Indicate this is the first packet after join network. 402 402 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 403 403 404 - (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.436 +Note: DO3 is not valid for LT-22222-L. 405 405 406 -**To use this mode, please run:** 407 407 408 -(% class="box infomessage" %) 409 -((( 410 -**AT+MOD=5** 411 -))) 439 +To use this mode, please run: 412 412 413 -(% class="box infomessage" %) 414 -((( 415 -**ATZ** 416 -))) 441 +AT+MOD=5 417 417 443 +ATZ 444 + 445 + 418 418 Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:#COUNT_COMMAND]]. 419 419 420 -=== 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 421 421 449 + 450 + 451 + 452 +1. 453 +11. 454 +111. AT+ADDMOD=6. (Trigger Mode, Optional) 455 + 422 422 **This mode is an optional mode for trigger purpose. It can run together with other mode.** 423 423 424 424 For example, if user has configured below commands: ... ... @@ -1336,6 +1336,7 @@ 1336 1336 |**RO1**| 1337 1337 |**RO2**| 1338 1338 1373 + 1339 1339 1. Use AT Command 1340 1340 11. Access AT Command 1341 1341
- image-20220523181246-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -5.5 KB - Content
- image-20220523181301-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -4.6 KB - Content
- image-20220523181727-7.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -4.8 KB - Content
- image-20220523181903-8.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -4.9 KB - Content
- image-20220523182334-9.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.4 KB - Content