Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,8 +4,13 @@ 4 4 **LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 +**Table of Contents:** 7 7 9 +{{toc/}} 8 8 11 + 12 + 13 + 9 9 = 1.Introduction = 10 10 11 11 == 1.1 What is LT Series I/O Controller == ... ... @@ -391,7 +391,6 @@ 391 391 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 392 392 ))) 393 393 394 - 395 395 * RO is for relay. ROx=1 : close,ROx=0 always open. 396 396 * FIRST: Indicate this is the first packet after join network. 397 397 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. ... ... @@ -412,62 +412,51 @@ 412 412 413 413 Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:#COUNT_COMMAND]]. 414 414 419 +=== 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 415 415 421 +(% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** 416 416 417 - 418 - 419 -1. 420 -11. 421 -111. AT+ADDMOD=6. (Trigger Mode, Optional) 422 - 423 -**This mode is an optional mode for trigger purpose. It can run together with other mode.** 424 - 425 425 For example, if user has configured below commands: 426 426 427 -* AT+MOD=1 àThe normal working mode428 -* AT+ADDMOD6=1 àEnable trigger425 +* **AT+MOD=1 ** **~-~->** The normal working mode 426 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 429 429 430 430 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 431 431 432 -1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN **unconfirmed** data type 433 -1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN **CONFIRMED data type.** 430 +1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 431 +1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 434 434 435 435 **AT Command to set Trigger Condition**: 436 436 437 -**Trigger base on voltage**: 435 +(% style="color:#4f81bd" %)**Trigger base on voltage**: 438 438 439 439 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> 440 440 441 -Example: 439 +**Example:** 442 442 443 443 AT+AVLIM=3000,6000,0,2000 (If AVI1 voltage lower than 3v or higher than 6v. or AV2 voltage is higher than 2v, LT will trigger Uplink) 444 444 445 445 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 446 446 445 +(% style="color:#4f81bd" %)**Trigger base on current**: 447 447 448 -**Trigger base on current**: 449 - 450 450 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> 451 451 452 -Example: 449 +**Example:** 453 453 454 454 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 455 455 453 +(% style="color:#4f81bd" %)**Trigger base on DI status**: 456 456 457 -**Trigger base on DI status**: 458 - 459 459 DI status trigger Flag. 460 460 461 461 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 462 462 463 -Example: 459 +**Example:** 464 464 465 465 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 466 466 467 467 468 - 469 - 470 - 471 471 **Downlink Command to set Trigger Condition** 472 472 473 473 Type Code: 0xAA. Downlink command same as AT Command [[AT+AVLIM, AT+ACLIM>>path:#AT_Trigger]] ... ... @@ -486,9 +486,8 @@ 486 486 487 487 Yy4 yy4: AC2 or AV2 high limit. 488 488 482 +**Example1**: AA 00 13 88 00 00 00 00 00 00 489 489 490 -Example1: AA 00 13 88 00 00 00 00 00 00 491 - 492 492 Same as AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 493 493 494 494 Example2: AA 02 01 00 ... ... @@ -495,35 +495,14 @@ 495 495 496 496 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 497 497 490 +(% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 498 498 499 - 500 - 501 -**Trigger Settings Payload Explanation:** 502 - 503 503 MOD6 Payload : total 11 bytes payload 504 504 505 -(% border="1" style="background-color:#f7faff" %) 506 -|Size(bytes)|1|1|1|6|1|1 507 -|Value|((( 508 -TRI_A 494 +[[image:image-20220524085923-1.png]] 509 509 510 -FLAG 511 -)))|((( 512 -TRI_A 496 +(% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 513 513 514 -Status 515 -)))|((( 516 -TRI_DI 517 - 518 -FLAG+STA 519 -)))|Reserve|Enable/Disable MOD6|((( 520 -MOD 521 - 522 -(6) 523 -))) 524 - 525 -**TRI FLAG1** is a combination to show if trigger is set for this part. Totally 1byte as below 526 - 527 527 (% border="1" style="background-color:#f7faff" %) 528 528 |bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 529 529 |((( ... ... @@ -567,7 +567,7 @@ 567 567 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW 568 568 569 569 570 -**TRI Status1** is a combination to show which condition is trigger. Totally 1byte as below 541 +(% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below 571 571 572 572 (% border="1" style="background-color:#f7faff" %) 573 573 |bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 ... ... @@ -614,7 +614,7 @@ 614 614 615 615 616 616 617 -**TRI_DI FLAG+STA **is a combination to show which condition is trigger. Totally 1byte as below 588 +(% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 618 618 619 619 (% border="1" style="background-color:#f7faff" %) 620 620 |bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 ... ... @@ -629,7 +629,7 @@ 629 629 00000101: Means both DI1 and DI2 trigger are enabled. 630 630 631 631 632 -**Enable/Disable MOD6 **: 0x01: MOD6 is enable. 0x00: MOD6 is disable. 603 +(% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 633 633 634 634 635 635 Downlink command to poll MOD6 status:
- image-20220524085923-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +6.4 KB - Content
- image-20220524090106-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +5.2 KB - Content