... ... @@ -27,7 +27,7 @@
27 27  **This manual is also applicable to the LT-33222-L.**
28 28  {{/info}}
29 29  
30 -The Dragino (% style="color:blue" %)**LT-22222-L I/O Controller**(%%) is an advanced LoRaWAN end device designed to provide seamless wireless long-range connectivity with various I/O options, including analog current and voltage inputs, digital inputs and outputs, and relay outputs.
30 +The Dragino (% style="color:blue" %)**LT-22222-L I/O Controller**(%%) is an advanced LoRaWAN device designed to provide seamless wireless long-range connectivity with various I/O options, including analog current and voltage inputs, digital inputs and outputs, and relay outputs.
31 31  
32 32  The LT-22222-L I/O Controller simplifies and enhances I/O monitoring and controlling. It is ideal for professional applications in wireless sensor networks, including irrigation systems, smart metering, smart cities, building automation, and more. These controllers are designed for easy, cost-effective deployment using LoRa wireless technology.
33 33  )))
... ... @@ -40,24 +40,23 @@
40 40  (((
41 41  You can connect the LT-22222-L I/O Controller to a LoRaWAN network service provider in several ways:
42 42  
43 -* If there is public LoRaWAN network coverage in the area where you plan to install the device (e.g., The Things Stack Community Network), you can select a network and register the LT-22222-L I/O controller with it.
43 +* If there is public LoRaWAN network coverage in the area where you plan to install the device (e.g., The Things Network), you can select a network and register the LT-22222-L I/O controller with it.
44 44  * If there is no public LoRaWAN coverage in your area, you can set up a LoRaWAN gateway, or multiple gateways, and connect them to a LoRaWAN network server to create adequate coverage. Then, register the LT-22222-L I/O controller with this network.
45 45  * Setup your own private LoRaWAN network.
46 +
47 +{{info}}
48 + You can use a LoRaWAN gateway, such as the [[Dragino LG308>>https://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], to expand or create LoRaWAN coverage in your area.
49 +{{/info}}
46 46  )))
47 47  
48 48  (((
49 -
53 +[[image:1653295757274-912.png]]
50 50  
51 -The network diagram below illustrates how the LT-22222-L communicates with a typical LoRaWAN network.
55 +
52 52  )))
53 53  
54 -(% class="wikigeneratedid" %)
55 -[[image:lorawan-nw.jpg||height="354" width="900"]]
56 -
57 -
58 58  == 1.2 Specifications ==
59 59  
60 -
61 61  (% style="color:#037691" %)**Hardware System:**
62 62  
63 63  * STM32L072xxxx MCU
... ... @@ -118,15 +118,13 @@
118 118  
119 119  == 1.5 Hardware Variants ==
120 120  
121 -
122 -(% border="1" cellspacing="3" style="background-color:#f2f2f2;width:510px" %)
123 -|(% style="width:94px;background-color:#4F81BD;color:white" %)**Model**|(% style="width:172px;background-color:#4F81BD;color:white" %)**Photo**|(% style="width:244px;background-color:#4F81BD;color:white" %)**Description**
124 -|(% style="width:94px" %)**LT-22222-L**|(% style="width:172px" %)(((
125 -(% style="text-align:center" %)
126 -[[image:lt33222-l.jpg||height="139" width="120"]]
127 -)))|(% style="width:256px" %)(((
128 -* 3 x Digital Input (Bi-direction)
129 -* 3 x Digital Output
120 +(% style="width:524px" %)
121 +|(% style="width:94px" %)**Model**|(% style="width:98px" %)**Photo**|(% style="width:329px" %)**Description**
122 +|(% style="width:94px" %)**LT33222-L**|(% style="width:98px" %)(((
123 +[[image:/xwiki/bin/downloadrev/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20230424115112-1.png?rev=1.1&width=58&height=106||alt="image-20230424115112-1.png" height="106" width="58"]]
124 +)))|(% style="width:329px" %)(((
125 +* 2 x Digital Input (Bi-direction)
126 +* 2 x Digital Output
130 130  * 2 x Relay Output (5A@250VAC / 30VDC)
131 131  * 2 x 0~~20mA Analog Input (res:0.01mA)
132 132  * 2 x 0~~30V Analog Input (res:0.01v)
... ... @@ -133,24 +133,26 @@
133 133  * 1 x Counting Port
134 134  )))
135 135  
136 -= 2. Assembling the device =
137 137  
134 +
135 +== 2. Assembling the device ==
136 +
138 138  == 2.1 Connecting the antenna ==
139 139  
140 140  Connect the LoRa antenna to the antenna connector, **ANT**,** **located on the top right side of the device, next to the upper screw terminal block. Secure the antenna by tightening it clockwise.
141 141  
142 142  {{warning}}
143 -**Warning! Do not power on the device without connecting the antenna.**
142 +Warning! Do not power on the device without connecting the antenna.
144 144  {{/warning}}
145 145  
146 146  == 2.2 Terminals ==
147 147  
148 -The  LT-22222-L has two screw terminal blocks. The upper screw treminal block has 6 screw terminals and the lower screw terminal block has 10 screw terminals.
147 +The  LT-22222-L has two screw terminal blocks. The upper screw treminal block has 6 terminals and the lower screw terminal block has 10 terminals.
149 149  
150 -**Upper screw terminal block (from left to right):**
149 +Upper screw terminal block (from left to right):
151 151  
152 152  (% style="width:634px" %)
153 -|=(% style="width: 295px;" %)Screw Terminal|=(% style="width: 338px;" %)Function
152 +|=(% style="width: 295px;" %)Terminal|=(% style="width: 338px;" %)Function
154 154  |(% style="width:295px" %)GND|(% style="width:338px" %)Ground
155 155  |(% style="width:295px" %)VIN|(% style="width:338px" %)Input Voltage
156 156  |(% style="width:295px" %)AVI2|(% style="width:338px" %)Analog Voltage Input Terminal 2
... ... @@ -158,10 +158,10 @@
158 158  |(% style="width:295px" %)ACI2|(% style="width:338px" %)Analog Current Input Terminal 2
159 159  |(% style="width:295px" %)ACI1|(% style="width:338px" %)Analog Current Input Terminal 1
160 160  
161 -**Lower screw terminal block (from left to right):**
160 +Lower screw terminal block (from left to right):
162 162  
163 163  (% style="width:633px" %)
164 -|=(% style="width: 296px;" %)Screw Terminal|=(% style="width: 334px;" %)Function
163 +|=(% style="width: 296px;" %)Terminal|=(% style="width: 334px;" %)Function
165 165  |(% style="width:296px" %)RO1-2|(% style="width:334px" %)Relay Output 1
166 166  |(% style="width:296px" %)RO1-1|(% style="width:334px" %)Relay Output 1
167 167  |(% style="width:296px" %)RO2-2|(% style="width:334px" %)Relay Output 2
... ... @@ -173,12 +173,14 @@
173 173  |(% style="width:296px" %)DO2|(% style="width:334px" %)Digital Output 2
174 174  |(% style="width:296px" %)DO1|(% style="width:334px" %)Digital Output 1
175 175  
176 -== 2.3 Connecting LT-22222-L to a Power Source ==
175 +== 2.3 Powering the device ==
177 177  
178 -The LT-22222-L I/O Controller can be powered by a **7–24V DC** power source. Connect your power supply’s **positive wire** to the **VIN** and the **negative wire** to the **GND** screw terminals. The power indicator **(PWR) LED** will turn on when the device is properly powered.
177 +The LT-22222-L I/O Controller can be powered by a **7–24V DC** power source. Connect your power supply’s positive wire to the VIN and the negative wire to the GND screw terminals. The power indicator **(PWR) LED** will turn on when the device is properly powered.
179 179  
179 +Once powered, the **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** The Things Stack. The **TX LED** will be on for **5 seconds** after joining the network. When there is a **downlink** message from the server, the **RX LED** will be on for **1 second**. When the device is sending an uplink message to the server, the **TX LED** will be on for **1 second**. See also LED status.
180 +
180 180  {{warning}}
181 -**We recommend that you power on the LT-22222-L after configuring its registration information with a LoRaWAN network server. Otherwise, the device will continuously send join-request messages to attempt to join a LoRaWAN network but will fail.**
182 +We recommend that you power on the LT-22222-L after configuring its registration information with a LoRaWAN network server. Otherwise, the device will continuously send join-request messages to attempt to join a LoRaWAN network but will fail.
182 182  {{/warning}}
183 183  
184 184  
... ... @@ -185,51 +185,36 @@
185 185  [[image:1653297104069-180.png]]
186 186  
187 187  
188 -= 3. Registering LT-22222-L with a LoRaWAN Network Server =
189 += 3. Registering with a LoRaWAN Network Server =
189 189  
190 -The LT-22222-L supports both OTAA (Over-the-Air Activation) and ABP (Activation By Personalization) methods to activate with a LoRaWAN Network Server. However, OTAA is the most secure method for activating a device with a LoRaWAN Network Server. OTAA regenerates session keys upon initial registration and regenerates new session keys after any subsequent reboots. By default, the LT-22222-L is configured to operate in LoRaWAN Class C mode.
191 +By default, the LT-22222-L is configured to operate in LoRaWAN Class C mode. It supports OTAA (Over-the-Air Activation), the most secure method for activating a device with a LoRaWAN network server. The LT-22222-L comes with device registration information that allows you to register it with a LoRaWAN network, enabling the device to perform OTAA activation with the network server upon initial power-up and after any subsequent reboots.
191 191  
193 +After powering on, the **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** the LoRaWAN network. The **TX LED** will be on for **5 seconds** after joining the network. When there is a **downlink** message from the server, the **RX LED** will be on for **1 second**. When the device is sending an uplink message to the server, the **TX LED** will be on for **1 second**. See also LED status.
192 192  
195 +In case you can't set the root key and other identifiers in the network server and must use them from the server, you can use [[AT Commands>>||anchor="H4.UseATCommand"]] to configure them on the device.
196 +
197 +The network diagram below shows how the LT-22222-L is connected to a typical LoRaWAN network.
198 +
199 +[[image:image-20220523172350-1.png||height="266" width="864"]]
200 +
193 193  === 3.2.1 Prerequisites ===
194 194  
195 -The LT-22222-L comes with device registration information such as DevEUI, AppEUI, and AppKey that allows you to register it with a LoRaWAN network. These registration information can be found on a sticker that can be found inside the package. Please keep the **registration information** sticker in a safe place for future reference.
203 +Make sure you have the device registration information such as DevEUI, AppEUI, and AppKey with you. The registration information can be found on a sticker that can be found inside the package. Please keep the **registration information** sticker in a safe place for future reference.
196 196  
197 197  [[image:image-20230425173427-2.png||height="246" width="530"]]
198 198  
199 -{{info}}
200 -In case you can't set the root key and other identifiers in the network server and must use them from the server, you can use [[AT Commands>>||anchor="H4.UseATCommand"]] to configure them on the device.
201 -{{/info}}
202 -
203 203  The following subsections explain how to register the LT-22222-L with different LoRaWAN network server providers.
204 204  
205 -=== 3.2.2 The Things Stack ===
209 +=== 3.2.2 The Things Stack Sandbox (TTSS) ===
206 206  
207 -This section guides you through how to register your LT-22222-L with The Things Stack Sandbox.
208 -
209 -{{info}}
210 210  The Things Stack Sandbox was formally called The Things Stack Community Edition.
211 -{{/info}}
212 212  
213 -
214 -The network diagram below illustrates the connection between the LT-22222-L and The Things Stack, as well as how the data can be integrated with the ThingsEye IoT platform.
215 -
216 -
217 -[[image:dragino-lorawan-nw-lt-22222-n.jpg]]
218 -
219 -{{info}}
220 - You can use a LoRaWAN gateway, such as the [[Dragino LPS8N>>https://www.dragino.com/products/lora-lorawan-gateway/item/200-lps8n.html]], to expand or create LoRaWAN coverage in your area.
221 -{{/info}}
222 -
223 -
224 -==== 3.2.2.1 Setting up ====
225 -
226 -* Sign up for a free account with [[The Things Stack Sandbox>>https://eu1.cloud.thethings.network]] if you do not have one yet.
227 -* Log in to your The Things Stack Sandbox account.
228 -* Create an **application** with The Things Stack if you do not have one yet (E.g., dragino-docs).
229 -* Go to your application's page and click on the **End devices** in the left menu.
213 +* Log in to your [[The Things Stack Sandbox>>https://eu1.cloud.thethings.network]] account.
214 +* Create an application with The Things Stack if you do not have one yet.
215 +* Go to your application page and click on the **End devices** in the left menu.
230 230  * On the End devices page, click on **+ Register end device**. Two registration options are available:
231 231  
232 -==== 3.2.2.2 Using the LoRaWAN Device Repository ====
218 +==== 3.2.2.1 Using the LoRaWAN Device Repository ====
233 233  
234 234  * On the **Register end device** page:
235 235  ** Select the option **Select the end device in the LoRaWAN Device Repository **under **Input method**.
... ... @@ -241,7 +241,7 @@
241 241  *** **Profile (Region)**: Select the region that matches your device.
242 242  ** Select the **Frequency plan** that matches your device from the **Frequency plan** dropdown list.
243 243  
244 -[[image:lt-22222-l-dev-repo-reg-p1.png]]
230 +[[image:lt-22222-l-dev-repo-reg-p1.png||height="625" width="1000"]]
245 245  
246 246  
247 247  * Register end device page continued...
... ... @@ -251,10 +251,11 @@
251 251  ** In the **End device ID** field, enter a unique name for your LT-22222-N within this application.
252 252  ** Under **After registration**, select the **View registered end device** option.
253 253  
254 -[[image:lt-22222-l-dev-repo-reg-p2.png]]
240 +[[image:lt-22222-l-dev-repo-reg-p2.png||height="625" width="1000"]]
255 255  
242 +==== ====
256 256  
257 -==== 3.2.2.3 Adding device manually ====
244 +==== 3.2.2.2 Adding device manually ====
258 258  
259 259  * On the **Register end device** page:
260 260  ** Select the option **Enter end device specifies manually** under **Input method**.
... ... @@ -265,11 +265,11 @@
265 265  ** Select the option **Over the air activation (OTAA)** under the **Activation mode.**
266 266  ** Select **Class C (Continuous)** from the **Additional LoRaWAN class capabilities** dropdown list.
267 267  
268 -[[image:lt-22222-l-manually-p1.png]]
255 +[[image:lt-22222-l-manually-p1.png||height="625" width="1000"]]
269 269  
270 270  
271 271  * Register end device page continued...
272 -** Enter the **AppEUI** in the **JoinEUI** field and click the **Confirm** button. If The Things Stack accepts the JoinEUI you provided, it will display the message '//**This end device can be registered on the network**//'
259 +** Enter the **AppEUI** in the **JoinEUI** field and click the **Confirm** button. If The Things Stack accepts the JoinEUI you provided, it will display the message 'This end device can be registered on the network'
273 273  ** In the **DevEUI** field, enter the **DevEUI**.
274 274  ** In the **AppKey** field, enter the **AppKey**.
275 275  ** In the **End device ID** field, enter a unique name for your LT-22222-N within this application.
... ... @@ -276,50 +276,41 @@
276 276  ** Under **After registration**, select the **View registered end device** option.
277 277  ** Click the **Register end device** button.
278 278  
279 -[[image:lt-22222-l-manually-p2.png]]
266 +[[image:lt-22222-l-manually-p2.png||height="625" width="1000"]]
280 280  
281 281  
282 282  You will be navigated to the **Device overview** page.
283 283  
284 284  
285 -[[image:lt-22222-device-overview.png]]
272 +[[image:lt-22222-device-overview.png||height="625" width="1000"]]
286 286  
287 287  
288 -==== 3.2.2.4 Joining ====
275 +==== 3.2.2.3 Joining ====
289 289  
290 -On the Device's page, click on **Live data** tab. The Live data panel for your device will display.
277 +On the Device overview page, click on **Live data** tab. The Live data panel for your device will display.
291 291  
292 -Now power on your LT-22222-L. The **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** The Things Stack network server. The **TX LED** will be on for **5 seconds** after joining the network. In the **Live data** panel, you can see the **join-request** and **join-accept** messages exchanged between the device and the network server.
279 +Now power on your LT-22222-L. It will begin joining The Things Stack. In the **Live data** panel, you can see the **join-request** and **join-accept** messages exchanged between the device and the network server. Once successfully joined, the device will send its first **uplink data message** to the application it belongs to (in this example, **dragino-docs**).
293 293  
294 294  
295 -[[image:lt-22222-l-joining.png]]
282 +[[image:lt-22222-join-network.png||height="625" width="1000"]]
296 296  
297 297  
285 +By default, you will receive an uplink data message from the device every 10 minutes.
298 298  
299 -==== 3.2.2.5 Uplinks ====
300 -
301 -
302 -After successfully joining, the device will send its first **uplink data message** to the application it belongs to (in this example, **dragino-docs**). When the LT-22222-L sends an uplink message to the server, the **TX LED** turns on for **1 second**. By default, you will receive an uplink data message from the device every 10 minutes.
303 -
304 304  Click on one of a **Forward uplink data messages **to see its payload content. The payload content is encapsulated within the decode_payload {} JSON object.
305 305  
306 306  [[image:lt-22222-ul-payload-decoded.png]]
307 307  
308 308  
309 -If you can't see the decoded payload, it is because you haven't added the uplink formatter code. To add the uplink formatter code, select **Applications > your application > End devices** > **your end device** > **Payload formatters** > **Uplink**. Then  select **Use Device repository formatters** for the **Formatter type** dropdown. Click the **Save changes** button to apply the changes.
292 +If you can't see the decoded payload, it is because you haven't added the uplink formatter code. To add the uplink formatter code, select **End devices** > **LT-22222-L** > **Payload formatters** > **Uplink**. Then  select **Use Device repository formatters** for the **Formatter type** dropdown. Click the **Save changes** button to apply the changes.
310 310  
311 311  {{info}}
312 312  The Things Stack provides two levels of payload formatters: application level and device level. The device-level payload formatters **override **the application-level payload formatters.
313 313  {{/info}}
314 314  
315 -[[image:lt-22222-ul-payload-fmt.png]]
298 +[[image:lt-22222-ul-payload-fmt.png||height="686" width="1000"]]
316 316  
317 317  
318 -==== 3.2.2.6 Downlinks ====
319 -
320 -When the LT-22222-L receives a downlink message from the server, the **RX LED** turns on for **1 second**.
321 -
322 -
323 323  == 3.3 Working Modes and Uplink Payload formats ==
324 324  
325 325  
... ... @@ -603,11 +603,11 @@
603 603  
604 604  (% style="color:blue" %)**AT+SETCNT=3,60 **(%%)**(Sets AVI1 Count to 60)**
605 605  
606 -(% style="color:blue" %)**AT+VOLMAX=20000 **(%%)**(If the AVI1 voltage is higher than VOLMAX (20000mV =20V), the counter increases by 1)**
584 +(% style="color:blue" %)**AT+VOLMAX=20000 **(%%)**(If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
607 607  
608 -(% style="color:blue" %)**AT+VOLMAX=20000,0 **(%%)**(If the AVI1 voltage is lower than VOLMAX (20000mV =20V), counter increases by 1)**
586 +(% style="color:blue" %)**AT+VOLMAX=20000,0 **(%%)**(If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
609 609  
610 -(% style="color:blue" %)**AT+VOLMAX=20000,1 **(%%)**(If the AVI1 voltage is higher than VOLMAX (20000mV =20V), counter increases by 1)**
588 +(% style="color:blue" %)**AT+VOLMAX=20000,1 **(%%)**(If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
611 611  )))
612 612  
613 613  
... ... @@ -726,9 +726,9 @@
726 726  
727 727  (% style="color:#037691" %)**LoRaWAN Downlink Commands for Setting the Trigger Conditions:**
728 728  
729 -**Type Code**: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
707 +Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
730 730  
731 -**Format**: AA xx yy1 yy1 yy2 yy2 yy3 yy3 yy4 yy4
709 +Format: AA xx yy1 yy1 yy2 yy2 yy3 yy3 yy4 yy4
732 732  
733 733   AA: Type Code for this downlink Command:
734 734  
... ... @@ -795,7 +795,7 @@
795 795  
796 796  **Example:**
797 797  
798 -10100000: This means the system is configured to use the triggers AV1_LOW and AV2_LOW.
776 +10100000: Means the system has configure to use the trigger: AV1_LOW and AV2_LOW
799 799  
800 800  
801 801  (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1 byte as below
... ... @@ -824,7 +824,7 @@
824 824  
825 825  **Example:**
826 826  
827 -10000000: The uplink is triggered by AV1_LOW, indicating that the voltage is too low.
805 +10000000: Means this uplink is triggered by AV1_LOW. That means the voltage is too low.
828 828  
829 829  
830 830  (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below
... ... @@ -833,22 +833,22 @@
833 833  |(% style="width:64px" %)**bit 7**|(% style="width:68px" %)**bit 6**|(% style="width:63px" %)**bit 5**|(% style="width:66px" %)**bit 4**|(% style="width:109px" %)**bit 3**|(% style="width:93px" %)**bit 2**|(% style="width:109px" %)**bit 1**|(% style="width:99px" %)**bit 0**
834 834  |(% style="width:64px" %)N/A|(% style="width:68px" %)N/A|(% style="width:63px" %)N/A|(% style="width:66px" %)N/A|(% style="width:109px" %)DI2_STATUS|(% style="width:93px" %)DI2_FLAG|(% style="width:109px" %)DI1_STATUS|(% style="width:99px" %)DI1_FLAG
835 835  
836 -* Each bit shows which status has been triggered on this uplink.
814 +* Each bits shows which status has been triggered on this uplink.
837 837  
838 838  **Example:**
839 839  
840 -00000111: This means both DI1 and DI2 triggers are enabled, and this packet is trigger by DI1.
818 +00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
841 841  
842 -00000101: This means both DI1 and DI2 triggers are enabled.
820 +00000101: Means both DI1 and DI2 trigger are enabled.
843 843  
844 844  
845 -(% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enabled. 0x00: MOD6 is disabled.
823 +(% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable.
846 846  
847 -Downlink command to poll/request MOD6 status:
825 +Downlink command to poll MOD6 status:
848 848  
849 849  **AB 06**
850 850  
851 -When device receives this command, it will send the MOD6 payload.
829 +When device got this command, it will send the MOD6 payload.
852 852  
853 853  
854 854  === 3.3.7 Payload Decoder ===
... ... @@ -887,7 +887,7 @@
887 887  These commands are specially designed for the LT-22222-L. Commands can be sent to the device using options such as an AT command or a LoRaWAN downlink payload.
888 888  
889 889  
890 -==== 3.4.2.1 Set Transmit/Uplink Interval ====
868 +==== 3.4.2.1 Set Transmit Interval ====
891 891  
892 892  Sets the uplink interval of the device. The default uplink transmission interval is 10 minutes.
893 893  
... ... @@ -896,11 +896,11 @@
896 896  (% border="2" style="width:500px" %)
897 897  |**Command**|AT+TDC=<time>
898 898  |**Response**|
899 -|**Parameters**|**time** : uplink interval is in **milliseconds**
877 +|**Parameters**|**time** : uplink interval is in milliseconds
900 900  |**Example**|(((
901 901  AT+TDC=30000
902 902  
903 -Sets the uplink interval to **30 seconds** (30000 milliseconds)
881 +Sets the uplink interval to 30,000 milliseconds (30 seconds)
904 904  )))
905 905  
906 906  (% style="color:#037691" %)**Downlink payload**
... ... @@ -912,18 +912,16 @@
912 912  |**Parameters**|(((
913 913  **prefix** : 0x01
914 914  
915 -**time** : uplink interval is in **seconds**, represented by **3  bytes** in **hexadecimal**.
893 +**time** : uplink interval is in milliseconds, represented by 3  bytes in hexadecimal.
916 916  )))
917 917  |**Example**|(((
918 -01 **00 00 1E**
896 +01 **00 75 30**
919 919  
920 -Sets the uplink interval to **30 seconds**
898 +Sets the uplink interval to 30,000 milliseconds (30 seconds)
921 921  
922 -Conversion: 30 (dec) = 00 00 1E (hex)
900 +Conversion: 30000 (dec) = 00 75 30 (hex)
923 923  
924 -See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30]]
925 -
926 -[[image:Screenshot 2024-11-23 at 18.27.11.png]]
902 +See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30000]]
927 927  )))
928 928  
929 929  ==== 3.4.2.2 Set the Working Mode (AT+MOD) ====
... ... @@ -972,13 +972,13 @@
972 972  Sets the device to working mode 2 (Double DI Counting + DO + RO)
973 973  )))
974 974  
975 -==== 3.4.2.3 Request an uplink from the device ====
951 +==== 3.4.2.3 Poll an uplink ====
976 976  
977 -Requests an uplink from LT-22222-L. The content of the uplink payload varies based on the device's current working mode.
953 +Requests an uplink from LT-22222-L.
978 978  
979 979  (% style="color:#037691" %)**AT command**
980 980  
981 -There is no AT Command available for this feature.
957 +There is no AT Command to request an uplink from LT-22222-L
982 982  
983 983  (% style="color:#037691" %)**Downlink payload**
984 984  
... ... @@ -986,7 +986,7 @@
986 986  |(% style="width:101px" %)**Payload**|(% style="width:397px" %)<prefix>FF
987 987  |(% style="width:101px" %)**Parameters**|(% style="width:397px" %)**prefix** : 0x08
988 988  |(% style="width:101px" %)**Example**|(% style="width:397px" %)(((
989 -08 **FF**
965 +08 FF
990 990  
991 991  Requests an uplink from LT-22222-L.
992 992  )))
... ... @@ -1020,7 +1020,7 @@
1020 1020  |(% style="width:97px" %)**Parameters**|(% style="width:401px" %)(((
1021 1021  **prefix** : 0x0A 06 (two bytes in hexadecimal)
1022 1022  
1023 -**enable/disable trigger_mode** : enable (1) or disable (0), represented by 1 byte in hexadecimal.
999 +**working mode** : enable (1) or disable (0), represented by 1 byte in hexadecimal.
1024 1024  )))
1025 1025  |(% style="width:97px" %)**Example**|(% style="width:401px" %)(((
1026 1026  0A 06 **01**
... ... @@ -1028,13 +1028,13 @@
1028 1028  Enable trigger mode for the current working mode
1029 1029  )))
1030 1030  
1031 -==== 3.4.2.5 Request trigger settings ====
1007 +==== 3.4.2.5 Poll trigger settings ====
1032 1032  
1033 -Requests the trigger settings.
1009 +Polls the trigger settings.
1034 1034  
1035 1035  (% style="color:#037691" %)**AT Command:**
1036 1036  
1037 -There is no AT Command available for this feature.
1013 +There is no AT Command for this feature.
1038 1038  
1039 1039  (% style="color:#037691" %)**Downlink Payload**
1040 1040  
... ... @@ -1174,6 +1174,8 @@
1174 1174  )))
1175 1175  |(% style="width:96px" %)**Example**|(% style="width:402px" %)09 02 **00 00 64**
1176 1176  
1153 +==== ====
1154 +
1177 1177  ==== 3.4.2.9 Trigger – Set AC (current) as a trigger ====
1178 1178  
1179 1179  Sets the current trigger based on the AC port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -1355,28 +1355,32 @@
1355 1355  )))
1356 1356  )))
1357 1357  
1336 +==== ====
1337 +
1358 1358  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
1359 1359  
1360 1360  
1361 1361  * (% style="color:#037691" %)**AT Command**
1362 1362  
1363 -There is no AT command to control the digital output.
1343 +There is no AT Command to control Digital Output
1364 1364  
1365 1365  
1366 1366  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)**
1367 1367  
1368 -(% style="color:blue" %)**0xA9 aa bb cc     **(%%) ~/~/ Sets DO1/DO2/DO3 outputs with time control
1348 +(% style="color:blue" %)**0xA9 aa bb cc     **(%%) ~/~/ Set DO1/DO2/DO3 output with time control
1369 1369  
1350 +
1370 1370  This is to control the digital output time of DO pin. Include four bytes:
1371 1371  
1372 -(% style="color:#4f81bd" %)**First byte**(%%)**:** Type code (0xA9)
1353 +(% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9)
1373 1373  
1374 -(% style="color:#4f81bd" %)**Second byte**(%%): Inverter Mode
1355 +(% style="color:#4f81bd" %)**Second Byte**(%%): Inverter Mode
1375 1375  
1376 -**01:** DO pins revert to their original state after the timeout.
1377 -**00:** DO pins switch to an inverted state after the timeout.
1357 +01: DO pins will change back to original state after timeout.
1378 1378  
1359 +00: DO pins will change to an inverter state after timeout 
1379 1379  
1361 +
1380 1380  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Port status:
1381 1381  
1382 1382  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
... ... @@ -1385,7 +1385,7 @@
1385 1385  |0x00|DO1 set to high
1386 1386  |0x11|DO1 NO Action
1387 1387  
1388 -(% style="color:#4f81bd" %)**Fourth byte**(%%): Control Method and Port status:
1370 +(% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Port status:
1389 1389  
1390 1390  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1391 1391  |(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status**
... ... @@ -1393,7 +1393,7 @@
1393 1393  |0x00|DO2 set to high
1394 1394  |0x11|DO2 NO Action
1395 1395  
1396 -(% style="color:#4f81bd" %)**Fifth byte**(%%): Control Method and Port status:
1378 +(% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Port status:
1397 1397  
1398 1398  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1399 1399  |(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status**
... ... @@ -1401,7 +1401,7 @@
1401 1401  |0x00|DO3 set to high
1402 1402  |0x11|DO3 NO Action
1403 1403  
1404 -(% style="color:#4f81bd" %)**Sixth, Seventh, Eighth, and Ninth bytes**:(%%) Latching time (Unit: ms)
1386 +(% style="color:#4f81bd" %)**Sixth, Seventh, Eighth, and Ninth Bytes**:(%%) Latching time (Unit: ms)
1405 1405  
1406 1406  
1407 1407  (% style="color:red" %)**Note: **
... ... @@ -1410,7 +1410,7 @@
1410 1410  
1411 1411   Before firmware v1.6.0, the latch time only supported 2 bytes.
1412 1412  
1413 -(% style="color:red" %)**The device will uplink a packet if the downlink code executes successfully.**
1395 +(% style="color:red" %)**Device will upload a packet if the downlink code executes successfully.**
1414 1414  
1415 1415  
1416 1416  **Example payload:**
... ... @@ -1437,16 +1437,16 @@
1437 1437  
1438 1438  * (% style="color:#037691" %)**AT Command:**
1439 1439  
1440 -There is no AT Command to control the Relay Output
1422 +There is no AT Command to control Relay Output
1441 1441  
1442 1442  
1443 1443  * (% style="color:#037691" %)**Downlink Payload (prefix 0x03):**
1444 1444  
1445 -(% style="color:blue" %)**0x03 aa bb     ** (%%)~/~/ Sets RO1/RO2 output
1427 +(% style="color:blue" %)**0x03 aa bb     ** (%%)~/~/ Set RO1/RO2 output
1446 1446  
1447 1447  
1448 1448  (((
1449 -If the payload is 0x030100, it means setting RO1 to close and RO2 to open.
1431 +If payload is 0x030100, it means setting RO1 to close and RO2 to open.
1450 1450  )))
1451 1451  
1452 1452  (((
... ... @@ -1464,7 +1464,7 @@
1464 1464  |03  00  01|Open|Close
1465 1465  )))
1466 1466  
1467 -(% style="color:red" %)**The device will uplink a packet if the downlink code executes successfully.**
1449 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1468 1468  
1469 1469  
1470 1470  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
... ... @@ -1473,19 +1473,19 @@
1473 1473  
1474 1474  * (% style="color:#037691" %)**AT Command:**
1475 1475  
1476 -There is no AT Command to control the Relay Output
1458 +There is no AT Command to control Relay Output
1477 1477  
1478 1478  
1479 1479  * (% style="color:#037691" %)**Downlink Payload (prefix 0x05):**
1480 1480  
1481 -(% style="color:blue" %)**0x05 aa bb cc dd     ** (%%)~/~/ Sets RO1/RO2 relays with time control
1463 +(% style="color:blue" %)**0x05 aa bb cc dd     ** (%%)~/~/ Set RO1/RO2 relay with time control
1482 1482  
1483 1483  
1484 -This controls the relay output time and includes 4 bytes:
1466 +This is to control the relay output time. It includes four bytes:
1485 1485  
1486 -(% style="color:#4f81bd" %)**First byte **(%%)**:** Type code (0x05)
1468 +(% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05)
1487 1487  
1488 -(% style="color:#4f81bd" %)**Second byte (aa)**(%%): Inverter Mode
1470 +(% style="color:#4f81bd" %)**Second Byte(aa)**(%%): Inverter Mode
1489 1489  
1490 1490  01: Relays will change back to their original state after timeout.
1491 1491  
... ... @@ -1492,12 +1492,12 @@
1492 1492  00: Relays will change to the inverter state after timeout.
1493 1493  
1494 1494  
1495 -(% style="color:#4f81bd" %)**Third byte (bb)**(%%): Control Method and Ports status:
1477 +(% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1496 1496  
1497 1497  [[image:image-20221008095908-1.png||height="364" width="564"]]
1498 1498  
1499 1499  
1500 -(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh bytes (cc)**(%%): Latching time. Unit: ms
1482 +(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms
1501 1501  
1502 1502  
1503 1503  (% style="color:red" %)**Note:**
... ... @@ -1507,7 +1507,7 @@
1507 1507   Before firmware v1.6.0, the latch time only supported 2 bytes.
1508 1508  
1509 1509  
1510 -(% style="color:red" %)**The device will uplink a packet if the downlink code executes successfully.**
1492 +(% style="color:red" %)**Device will upload a packet if the downlink code executes successfully.**
1511 1511  
1512 1512  
1513 1513  **Example payload:**
... ... @@ -1535,10 +1535,17 @@
1535 1535  
1536 1536  When the voltage exceeds the threshold, counting begins. For details, see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1537 1537  
1520 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+VOLMAX   ** (%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1521 +
1522 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**
1523 +
1524 +(% style="color:blue" %)**0xA5 aa bb cc   ** (%%)~/~/ Same as AT+VOLMAX=(aa bb),cc
1525 +
1526 +
1538 1538  (% style="color:#037691" %)**AT Command**
1539 1539  
1540 1540  (% border="2" style="width:500px" %)
1541 -|(% style="width:137px" %)**Command**|(% style="width:361px" %)AT+VOLMAX=<voltage>,<logic>
1530 +|(% style="width:137px" %)**Command**|(% style="width:361px" %)AT+VOLMAX=<voltage><logic>
1542 1542  |(% style="width:137px" %)**Response**|(% style="width:361px" %)
1543 1543  |(% style="width:137px" %)**Parameters**|(% style="width:361px" %)(((
1544 1544  **voltage** : voltage threshold in mV
... ... @@ -1545,9 +1545,9 @@
1545 1545  
1546 1546  **logic**:
1547 1547  
1548 -**0** : lower than
1537 +0 : lower than
1549 1549  
1550 -**1**: higher than
1539 +1: higher than
1551 1551  
1552 1552  if you leave logic parameter blank, it is considered 0
1553 1553  )))
... ... @@ -1576,9 +1576,9 @@
1576 1576  
1577 1577  **logic**: (1 byte in hexadecimal)
1578 1578  
1579 -**0** : lower than
1568 +0 : lower than
1580 1580  
1581 -**1**: higher than
1570 +1: higher than
1582 1582  
1583 1583  if you leave logic parameter blank, it is considered 1 (higher than)
1584 1584  )))
... ... @@ -1598,12 +1598,24 @@
1598 1598  
1599 1599  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1600 1600  
1601 -This command allows users to pre-configure specific count numbers for various counting parameters such as Count1, Count2, or AVI1 Count. Use the AT command to set the desired count number for each configuration.
1590 +This feature allows users to pre-configure specific count numbers for various counting parameters such as Count1, Count2, or AVI1 Count. Use the AT command to set the desired count number for each configuration.
1602 1602  
1592 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) **
1593 +
1594 +(% style="color:red" %)**aa:**(%%) 1: Set count1; 2: Set count2; 3: Set AV1 count
1595 +
1596 +(% style="color:red" %)**bb cc dd ee: **(%%)The number to be set
1597 +
1598 +
1599 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):**
1600 +
1601 +(% style="color:blue" %)**0x A8 aa bb cc dd ee     ** (%%)~/~/ same as AT+SETCNT=aa,(bb cc dd ee)
1602 +
1603 +
1603 1603  (% style="color:#037691" %)**AT Command**
1604 1604  
1605 1605  (% border="2" style="width:500px" %)
1606 -|(% style="width:134px" %)**Command**|(% style="width:364px" %)AT+SETCNT=<counting_parameter>,<number>
1607 +|(% style="width:134px" %)**Command**|(% style="width:364px" %)AT+SETCNT=<counting_parameter><number>
1607 1607  |(% style="width:134px" %)**Response**|(% style="width:364px" %)
1608 1608  |(% style="width:134px" %)**Parameters**|(% style="width:364px" %)(((
1609 1609  **counting_parameter** :
... ... @@ -1647,8 +1647,14 @@
1647 1647  
1648 1648  ==== 3.4.2.18 Counting ~-~- Clear Counting ====
1649 1649  
1650 -This command clears the counting in counting mode.
1651 +This feature clears the counting in counting mode.
1651 1651  
1653 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+CLRCOUNT         **(%%) ~/~/ clear all counting
1654 +
1655 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
1656 +
1657 +(% style="color:blue" %)**0x A6 01    ** (%%)~/~/ clear all counting
1658 +
1652 1652  (% style="color:#037691" %)**AT Command**
1653 1653  
1654 1654  (% border="2" style="width:500px" %)
... ... @@ -1666,225 +1666,94 @@
1666 1666  )))
1667 1667  |(% style="width:141px" %)**Example**|(% style="width:357px" %)A6 **01**
1668 1668  
1669 -==== 3.4.2.19 Counting ~-~- Set Saving Interval for 'Counting Result' ====
1676 +==== 3.4.2.19 Counting ~-~- Change counting mode to save time ====
1670 1670  
1671 -This command allows you to configure the device to save its counting result to internal flash memory at specified intervals. By setting a save time, the device will periodically store the counting data to prevent loss in case of power failure. The save interval can be adjusted to suit your requirements, with a minimum value of 30 seconds.
1678 +This feature allows you to configure the device to save its counting result to internal flash memory at specified intervals. By setting a save time, the device will periodically store the counting data to prevent loss in case of power failure. The save interval can be adjusted to suit your requirements, with a minimum value of 30 seconds.
1672 1672  
1673 -(% style="color:#037691" %)**AT Command**
1680 +* (% style="color:#037691" %)**AT Command:**
1674 1674  
1675 -(% border="2" style="width:500px" %)
1676 -|(% style="width:124px" %)**Command**|(% style="width:374px" %)AT+COUTIME=<time>
1677 -|(% style="width:124px" %)**Response**|(% style="width:374px" %)
1678 -|(% style="width:124px" %)**Parameters**|(% style="width:374px" %)time : seconds (0 to 16777215)
1679 -|(% style="width:124px" %)**Example**|(% style="width:374px" %)(((
1680 -AT+COUTIME=60
1682 +(% style="color:blue" %)**AT+COUTIME=60  **(%%)~/~/ Sets the save time to 60 seconds. The device will save the counting result in internal flash every 60 seconds. (Min value: 30 seconds)
1681 1681  
1682 -Sets the device to save its counting results to the memory every 60 seconds.
1683 -)))
1684 1684  
1685 -(% style="color:#037691" %)**Downlink Payload**
1685 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):**
1686 1686  
1687 -(% border="2" style="width:500px" %)
1688 -|(% style="width:123px" %)**Payload**|(% style="width:375px" %)<prefix><time>
1689 -|(% style="width:123px" %)**Parameters**|(% style="width:375px" %)(((
1690 -prefix : A7
1687 +(% style="color:blue" %)**0x A7 aa bb cc     ** (%%)~/~/ same as AT+COUTIME =aa bb cc,
1691 1691  
1692 -time : seconds, 3 bytes in hexadecimal
1689 +(((
1690 +Range: aa bb cc:0 to 16777215,  (unit: seconds)
1693 1693  )))
1694 -|(% style="width:123px" %)**Example**|(% style="width:375px" %)(((
1695 -A7 **00 00 3C**
1696 1696  
1697 -Sets the device to save its counting results to the memory every 60 seconds.
1698 -)))
1699 1699  
1700 -==== 3.4.2.20 Reset saved RO and DO states ====
1701 1701  
1702 -This command allows you to reset the saved relay output (RO) and digital output (DO) states when the device joins the network. By configuring this setting, you can control whether the device should retain or reset the relay states after a reset and rejoin to the network.
1695 +==== 3.4.2.20 Reset save RO DO state ====
1703 1703  
1704 -(% style="color:#037691" %)**AT Command**
1697 +This feature allows you to reset the saved relay output (RO) and digital output (DO) states when the device joins the network. By configuring this setting, you can control whether the device should retain or reset the relay states after a reset and rejoin to the network.
1705 1705  
1706 -(% border="2" style="width:500px" %)
1707 -|(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+RODORESET=<state>
1708 -|(% style="width:127px" %)**Response**|(% style="width:371px" %)
1709 -|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)(((
1710 -**state** :
1699 +* (% style="color:#037691" %)**AT Command:**
1711 1711  
1712 -**0** RODO will close when the device joins the network. (default)
1701 +(% style="color:blue" %)**AT+RODORESET=1    **(%%)~/~/ RODO will close when the device joining the network. (default)
1713 1713  
1714 -**1**: After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network.
1715 -)))
1716 -|(% style="width:127px" %)**Example**|(% style="width:371px" %)(((
1717 -(% style="color:blue" %)**AT+RODORESET=1 **
1703 +(% style="color:blue" %)**AT+RODORESET=0    **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state will not change when the device reconnects to the network.
1718 1718  
1719 -RODO will close when the device joins the network. (default)
1720 1720  
1721 -(% style="color:blue" %)**AT+RODORESET=0 **
1706 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):**
1722 1722  
1723 -After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network.
1724 -)))
1708 +(% style="color:blue" %)**0x AD aa      ** (%%)~/~/ same as AT+RODORET =aa
1725 1725  
1726 -(% style="color:#037691" %)**Downlink Payload**
1727 1727  
1728 -(% border="2" style="width:500px" %)
1729 -|(% style="width:127px" %)**Payload**|(% style="width:371px" %)<prefix><state>
1730 -|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)(((
1731 -**prefix** : AD
1732 1732  
1733 -**state** :
1734 -
1735 -**0** : RODO will close when the device joins the network. (default), represents as 1 byte in hexadecimal.
1736 -
1737 -**1**: After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network. - represents as 1 byte in hexadecimal
1738 -)))
1739 -|(% style="width:127px" %)**Example**|(% style="width:371px" %)(((
1740 -AD **01**
1741 -
1742 -RODO will close when the device joins the network. (default)
1743 -
1744 -AD **00**
1745 -
1746 -After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network.
1747 -)))
1748 -
1749 1749  ==== 3.4.2.21 Encrypted payload ====
1750 1750  
1751 -This command allows you to configure whether the device should upload data in an encrypted format or in plaintext. By default, the device encrypts the payload before uploading. You can toggle this setting to either upload encrypted data or transmit it without encryption.
1714 +This feature allows you to configure whether the device should upload data in an encrypted format or in plaintext. By default, the device encrypts the payload before uploading. You can toggle this setting to either upload encrypted data or transmit it without encryption.
1752 1752  
1753 -(% style="color:#037691" %)**AT Command:**
1716 +* (% style="color:#037691" %)**AT Command:**
1754 1754  
1755 -(% border="2" style="width:500px" %)
1756 -|(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+DECRYPT=<state>
1757 -|(% style="width:127px" %)**Response**|(% style="width:371px" %)
1758 -|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)(((
1759 -**state** :
1718 +(% style="color:blue" %)**AT+DECRYPT=1  ** (%%)~/~/ The payload is uploaded without encryption
1760 1760  
1761 -**1** : The payload is uploaded without encryption
1720 +(% style="color:blue" %)**AT+DECRYPT=0    **(%%)~/~/  Encrypt when uploading payload (default)
1762 1762  
1763 -**0** : The payload is encrypted when uploaded (default)
1764 -)))
1765 -|(% style="width:127px" %)**Example**|(% style="width:371px" %)(((
1766 -AT+DECRYPT=1
1767 1767  
1768 -The payload is uploaded without encryption
1769 1769  
1770 -AT+DECRYPT=0
1771 -
1772 -The payload is encrypted when uploaded (default)
1773 -)))
1774 -
1775 -There is no downlink payload for this configuration.
1776 -
1777 -
1778 1778  ==== 3.4.2.22 Get sensor value ====
1779 1779  
1780 -This command allows you to retrieve and optionally uplink sensor readings through the serial port.
1781 1781  
1782 -(% style="color:#037691" %)**AT Command**
1727 +* (% style="color:#037691" %)**AT Command:**
1783 1783  
1784 -(% border="2" style="width:500px" %)
1785 -|(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+GETSENSORVALUE=<state>
1786 -|(% style="width:127px" %)**Response**|(% style="width:371px" %)
1787 -|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)(((
1788 -**state** :
1729 +(% style="color:blue" %)**AT+GETSENSORVALUE=0    **(%%)~/~/ The serial port retrieves the reading of the current sensor.
1789 1789  
1790 -**0 **: Retrieves the current sensor reading via the serial port.
1731 +(% style="color:blue" %)**AT+GETSENSORVALUE=1    **(%%)~/~/ The serial port retrieves the current sensor reading and uploads it.
1791 1791  
1792 -**1 **: Retrieves and uploads the current sensor reading via the serial port.
1793 -)))
1794 -|(% style="width:127px" %)**Example**|(% style="width:371px" %)(((
1795 -AT+GETSENSORVALUE=0
1796 1796  
1797 -Retrieves the current sensor reading via the serial port.
1798 1798  
1799 -AT+GETSENSORVALUE=1
1735 +==== 3.4.2.23 Resets the downlink packet count ====
1800 1800  
1801 -Retrieves and uplinks the current sensor reading via the serial port.
1802 -)))
1803 1803  
1804 -There is no downlink payload for this configuration.
1738 +* (% style="color:#037691" %)**AT Command:**
1805 1805  
1740 +(% style="color:blue" %)**AT+DISFCNTCHECK=0   **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default)
1806 1806  
1807 -==== 3.4.2.23 Resetting the downlink packet count ====
1742 +(% style="color:blue" %)**AT+DISFCNTCHECK=1   **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count.
1808 1808  
1809 -This command manages how the node handles mismatched downlink packet counts. It offers two modes: one disables the reception of further downlink packets if discrepancies occur, while the other resets the downlink packet count to align with the server, ensuring continued communication.
1810 1810  
1811 -(% style="color:#037691" %)**AT Command**
1812 1812  
1813 -(% border="2" style="width:500px" %)
1814 -|(% style="width:130px" %)**Command**|(% style="width:368px" %)AT+DISFCNTCHECK=<state>
1815 -|(% style="width:130px" %)**Response**|(% style="width:368px" %)(((
1816 -
1817 -)))
1818 -|(% style="width:130px" %)**Parameters**|(% style="width:368px" %)(((
1819 -**state **:
1820 -
1821 -**0** : When the downlink packet count sent by the server is less than the node's downlink packet count or exceeds 16,384, the node stops receiving further downlink packets (default).
1822 -
1823 -
1824 -**1** : When the downlink packet count sent by the server is less than the node's downlink packet count or exceeds 16,384, the node resets its downlink packet count to match the server's, ensuring consistency.
1825 -)))
1826 -|(% style="width:130px" %)**Example**|(% style="width:368px" %)(((
1827 -AT+DISFCNTCHECK=0
1828 -
1829 -When the downlink packet count sent by the server is less than the node's downlink packet count or exceeds 16,384, the node stops receiving further downlink packets (default).
1830 -
1831 -AT+DISFCNTCHECK=1
1832 -
1833 -When the downlink packet count sent by the server is less than the node's downlink packet count or exceeds 16,384, the node resets its downlink packet count to match the server's, ensuring consistency.
1834 -)))
1835 -
1836 -There is no downlink payload for this configuration.
1837 -
1838 -
1839 1839  ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ====
1840 1840  
1841 1841  
1842 -This command controls the behavior of the node when the combined size of the MAC commands (MACANS) from the server and the payload exceeds the allowed byte limit for the current data rate (DR). The command provides two modes: one enables splitting the data into batches to ensure compliance with the byte limit, while the other prioritizes the payload and ignores the MACANS in cases of overflow.
1749 +* (% style="color:#037691" %)**AT Command:**
1843 1843  
1844 -(% style="color:#037691" %)**AT Command**
1751 +(% style="color:blue" %)**AT+DISMACANS=0**   (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default)
1845 1845  
1846 -(% border="2" style="width:500px" %)
1847 -|(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+DISMACANS=<state>
1848 -|(% style="width:127px" %)**Response**|(% style="width:371px" %)
1849 -|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)(((
1850 -**state** :
1753 +(% style="color:blue" %)**AT+DISMACANS=1**  (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part.
1851 1851  
1852 -**0** : When the combined size of the MACANS from the server and the payload exceeds the byte limit (11 bytes for DR0 of US915, DR2 of AS923, DR2 of AU915), the node sends a packet with a payload of 00 and a port of 4. (default)
1853 1853  
1854 -**1** : When the combined size of the MACANS from the server and the payload exceeds the byte limit for the current DR, the node ignores the MACANS and only uploads the payload.
1855 -)))
1856 -|(% style="width:127px" %)**Example**|(% style="width:371px" %)(((
1857 -AT+DISMACANS=0
1756 +* (% style="color:#037691" %)**Downlink Payload **(%%)**:**
1858 1858  
1859 -When the combined size of the MACANS from the server and the payload exceeds the byte limit (11 bytes for DR0 of US915, DR2 of AS923, DR2 of AU915), the node sends a packet with a payload of 00 and a port of 4. (default)
1758 +(% style="color:blue" %)**0x21 00 01 ** (%%) ~/~/ Set  the DISMACANS=1
1860 1860  
1861 -AT+DISMACANS=1
1862 1862  
1863 -When the combined size of the MACANS from the server and the payload exceeds the byte limit for the current DR, the node ignores the MACANS and only uploads the payload.
1864 -)))
1865 1865  
1866 -(% style="color:#037691" %)**Downlink Payload**
1867 -
1868 -(% border="2" style="width:500px" %)
1869 -|(% style="width:126px" %)**Payload**|(% style="width:372px" %)<prefix><state>
1870 -|(% style="width:126px" %)**Parameters**|(% style="width:372px" %)(((
1871 -**prefix** : 21
1872 -
1873 -**state** : (2 bytes in hexadecimal)
1874 -
1875 -**0** : When the combined size of the MACANS from the server and the payload exceeds the byte limit (11 bytes for DR0 of US915, DR2 of AS923, DR2 of AU915), the node sends a packet with a payload of 00 and a port of 4. (default)
1876 -
1877 -**1 **: When the combined size of the MACANS from the server and the payload exceeds the byte limit for the current DR, the node ignores the MACANS and only uploads the payload.
1878 -)))
1879 -|(% style="width:126px" %)**Example**|(% style="width:372px" %)(((
1880 -21 **00 01**
1881 -
1882 -Set DISMACANS=1
1883 -)))
1884 -
1885 1885  ==== 3.4.2.25 Copy downlink to uplink ====
1886 1886  
1887 -This command enables the device to immediately uplink the content of a received downlink packet back to the server. The command allows for quick data replication from downlink to uplink, with a fixed port number of 100.
1888 1888  
1889 1889  * (% style="color:#037691" %)**AT Command**(%%)**:**
1890 1890  
... ... @@ -1897,22 +1897,8 @@
1897 1897  
1898 1898  For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77.
1899 1899  
1900 -(% border="2" style="width:500px" %)
1901 -|(% style="width:122px" %)**Command**|(% style="width:376px" %)(((
1902 -AT+RPL=5
1903 1903  
1904 -After receiving a downlink packet from the server, the node immediately uplinks the content of the packet back to the server using port number 100.
1905 -)))
1906 -|(% style="width:122px" %)**Example**|(% style="width:376px" %)(((
1907 -Downlink:
1908 1908  
1909 -01 00 02 58
1910 -
1911 -Uplink:
1912 -
1913 -01 01 00 02 58
1914 -)))
1915 -
1916 1916  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]]
1917 1917  
1918 1918  For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned.
... ... @@ -1919,16 +1919,14 @@
1919 1919  
1920 1920  
1921 1921  
1922 -==== 3.4.2.26 Query firmware version, frequency band, sub band, and TDC time ====
1784 +==== 3.4.2.26 Query version number and frequency band TDC ====
1923 1923  
1924 -This command is used to query key information about the device, including its firmware version, frequency band, sub band, and TDC time. By sending the specified payload as a downlink, the server can retrieve this essential data from the device.
1925 1925  
1926 1926  * (((
1927 1927  (% style="color:#037691" %)**Downlink Payload**(%%)**:**
1928 1928  
1929 -(% style="color:blue" %)**26 01  ** (%%) ~/~/  The downlink payload 26 01 is used to query the device's firmware version, frequency band, sub band, and TDC time.
1790 +(% style="color:blue" %)**26 01  ** (%%) ~/~/  Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time.
1930 1930  
1931 -
1932 1932  
1933 1933  )))
1934 1934  
... ... @@ -1954,17 +1954,15 @@
1954 1954  The username and  password (API key) you created here are required in the next section.
1955 1955  {{/info}}
1956 1956  
1957 -[[image:tts-mqtt-integration.png]]
1817 +[[image:tts-mqtt-integration.png||height="625" width="1000"]]
1958 1958  
1959 1959  === 3.5.2 Configuring ThingsEye.io ===
1960 1960  
1961 -The ThingsEye.io IoT platform is not open for self-registration at the moment. If you are interested in testing the platform, please send your project information to admin@thingseye.io, and we will create an account for you.
1962 -
1963 1963  * Login to your [[ThingsEye.io >>https://thingseye.io]]account.
1964 1964  * Under the **Integrations center**, click **Integrations**.
1965 1965  * Click the **Add integration** button (the button with the **+** symbol).
1966 1966  
1967 -[[image:thingseye-io-step-1.png]]
1825 +[[image:thingseye-io-step-1.png||height="625" width="1000"]]
1968 1968  
1969 1969  
1970 1970  On the **Add integration** window, configure the following:
... ... @@ -1979,7 +1979,7 @@
1979 1979  ** Allow create devices or assets
1980 1980  * Click the **Next** button. you will be navigated to the **Uplink data converter** tab.
1981 1981  
1982 -[[image:thingseye-io-step-2.png]]
1840 +[[image:thingseye-io-step-2.png||height="625" width="1000"]]
1983 1983  
1984 1984  
1985 1985  **Uplink data converter:**
... ... @@ -1990,7 +1990,7 @@
1990 1990  * Paste the uplink decoder function into the text area (first, delete the default code). The demo uplink decoder function can be found [[here>>https://raw.githubusercontent.com/ThingsEye-io/te-platform/refs/heads/main/Data%20Converters/The_Things_Network_MQTT_Uplink_Converter.js]].
1991 1991  * Click the **Next** button. You will be navigated to the **Downlink data converter **tab.
1992 1992  
1993 -[[image:thingseye-io-step-3.png]]
1851 +[[image:thingseye-io-step-3.png||height="625" width="1000"]]
1994 1994  
1995 1995  
1996 1996  **Downlink data converter (this is an optional step):**
... ... @@ -2001,7 +2001,7 @@
2001 2001  * Paste the downlink decoder function into the text area (first, delete the default code). The demo downlink decoder function can be found [[here>>https://raw.githubusercontent.com/ThingsEye-io/te-platform/refs/heads/main/Data%20Converters/The_Things_Network_MQTT_Downlink_Converter.js]].
2002 2002  * Click the **Next** button. You will be navigated to the **Connection** tab.
2003 2003  
2004 -[[image:thingseye-io-step-4.png]]
1862 +[[image:thingseye-io-step-4.png||height="625" width="1000"]]
2005 2005  
2006 2006  
2007 2007  **Connection:**
... ... @@ -2008,7 +2008,7 @@
2008 2008  
2009 2009  * Choose **Region** from the **Host type**.
2010 2010  * Enter the **cluster** of your **The Things Stack** in the **Region** textbox. You can find the cluster in the url (e.g., https:~/~/**eu1**.cloud.thethings.network/...).
2011 -* Enter the **Username** and **Password** of the MQTT integration in the **Credentials** section. The **username **and **password **can be found on the MQTT integration page of your The Things Stack account (see **3.5.1 Configuring The Things Stack**).
1869 +* Enter the **Username** and **Password** of the MQTT integration in the **Credentials** section. The **username **and **password **can be found on the MQTT integration page of your The Things Stack account (see Configuring The Things Stack).
2012 2012  * Click the **Check connection** button to test the connection. If the connection is successful, you will see the message saying **Connected**.
2013 2013  
2014 2014  [[image:message-1.png]]
... ... @@ -2016,13 +2016,13 @@
2016 2016  
2017 2017  * Click the **Add** button.
2018 2018  
2019 -[[image:thingseye-io-step-5.png]]
1877 +[[image:thingseye-io-step-5.png||height="625" width="1000"]]
2020 2020  
2021 2021  
2022 -Your integration has been added to the** Integrations** list and will be displayed on the **Integrations** page. Check whether the status is shown as **Active**. If not, review your configuration settings and correct any errors.
1880 +Your integration has been added to the** Integrations** list and will be displayed on the **Integrations** page. Check whether the status is shown as **Active**. If not, review your configuration settings.
2023 2023  
2024 2024  
2025 -[[image:thingseye.io_integrationsCenter_integrations.png]]
1883 +[[image:thingseye.io_integrationsCenter_integrations.png||height="686" width="1000"]]
2026 2026  
2027 2027  
2028 2028  ==== 3.5.2.1 Viewing integration details ====
... ... @@ -2029,13 +2029,13 @@
2029 2029  
2030 2030  Click on your integration from the list. The **Integration details** window will appear with the **Details **tab selected. The **Details **tab shows all the settings you have provided for this integration.
2031 2031  
2032 -[[image:integration-details.png]]
1890 +[[image:integration-details.png||height="686" width="1000"]]
2033 2033  
2034 2034  
2035 2035  If you want to edit the settings you have provided, click on the **Toggle edit mode** button. Once you have done click on the **Apply changes **button.
2036 2036  
2037 2037  {{info}}
2038 -See also [[ThingsEye documentation>>https://wiki.thingseye.io/xwiki/bin/view/Main/]].
1896 +See also ThingsEye documentation.
2039 2039  {{/info}}
2040 2040  
2041 2041  ==== **3.5.2.2 Viewing events** ====
... ... @@ -2045,12 +2045,12 @@
2045 2045  * Select **Debug **from the **Event type** dropdown.
2046 2046  * Select the** time frame** from the **time window**.
2047 2047  
2048 -[[image:thingseye-events.png]]
1906 +[[image:thingseye-events.png||height="686" width="1000"]]
2049 2049  
2050 2050  
2051 -* To view the **JSON payload** of a message, click on the **three dots (...)** in the Message column of the desired message.
1909 +* To view the JSON payload of a message, click on the three dots (...) in the Message column of the desired message.
2052 2052  
2053 -[[image:thingseye-json.png]]
1911 +[[image:thingseye-json.png||width="1000"]]
2054 2054  
2055 2055  
2056 2056  ==== **3.5.2.3 Deleting an integration** ====
... ... @@ -2058,17 +2058,12 @@
2058 2058  If you want to delete an integration, click the **Delete integratio**n button on the Integrations page.
2059 2059  
2060 2060  
2061 -==== 3.5.2.4 Creating a Dashboard to Display and Analyze LT-22222-L Data ====
2062 -
2063 -This will be added soon.
2064 -
2065 -
2066 2066  == 3.6 Interface Details ==
2067 2067  
2068 2068  === 3.6.1 Digital Input Ports: DI1/DI2/DI3 (For LT-33222-L, Low Active) ===
2069 2069  
2070 2070  
2071 -Supports** NPN-type **sensors.
1924 +Supports NPN-type sensors.
2072 2072  
2073 2073  [[image:1653356991268-289.png]]
2074 2074  
... ... @@ -2190,15 +2190,15 @@
2190 2190  )))
2191 2191  
2192 2192  
2193 -(% style="color:blue" %)**Example 4**(%%): Connecting to a Dry Contact sensor
2046 +(% style="color:blue" %)**Example4**(%%): Connecting to Dry Contact sensor
2194 2194  
2195 -From the DI port circuit above, activating the photocoupler requires a voltage difference between the DI+ and DI- ports. However, the Dry Contact sensor is a passive component and cannot provide this voltage difference on its own.
2048 +From the DI port circuit above, you can see that activating the photocoupler requires a voltage difference between the DI+ and DI- ports. However, the Dry Contact sensor is a passive component and cannot provide this voltage difference.
2196 2196  
2197 -To detect a Dry Contact, you can supply a power source to one of the pins of the Dry Contact. A reference circuit diagram is shown below.
2050 +To detect a Dry Contact, you can supply a power source to one pin of the Dry Contact. Below is a reference circuit diagram.
2198 2198  
2199 2199  [[image:image-20230616235145-1.png]]
2200 2200  
2201 -(% style="color:blue" %)**Example 5**(%%): Connecting to an Open Collector
2054 +(% style="color:blue" %)**Example5**(%%): Connecting to an Open Collector
2202 2202  
2203 2203  [[image:image-20240219115718-1.png]]
2204 2204  
... ... @@ -2274,7 +2274,7 @@
2274 2274  [[image:image-20220524100215-10.png||height="382" width="723"]]
2275 2275  
2276 2276  
2277 -== 3.7 LED Indicators ==
2130 +== 3.7 LEDs Indicators ==
2278 2278  
2279 2279  The table below lists the behavior of LED indicators for each port function.
2280 2280  
... ... @@ -2313,14 +2313,13 @@
2313 2313  == 4.1 Connecting the LT-22222-L to a PC ==
2314 2314  
2315 2315  (((
2316 -You can use a USB-to-TTL adapter/converter along with a 3.5mm Program Cable to connect the LT-22222-L to a PC, as shown below.
2169 +You can use a USB-to-TTL adapter along with a 3.5mm Program Cable to connect the LT-22222-L to a PC, as shown below.
2317 2317  
2318 -[[image:usb-ttl-audio-jack-connection.jpg]]
2319 -
2320 -
2171 +[[image:usb-ttl-programming.png]]
2321 2321  )))
2322 2322  
2323 2323  
2175 +
2324 2324  (((
2325 2325  On the PC, you need to set the (% style="color:#4f81bd" %)**serial tool **(%%)(such as [[PuTTY>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]] or [[SecureCRT>>https://www.vandyke.com/cgi-bin/releases.php?product=securecrt]]) to a baud rate of (% style="color:green" %)**9600**(%%) to access the serial console of LT-22222-L. Access to AT commands is disabled by default, and a password (default: (% style="color:green" %)**123456**)(%%) must be entered to enable AT command access, as shown below:
2326 2326  )))
... ... @@ -2350,39 +2350,39 @@
2350 2350  * **##AT+APPSKEY##**: Get or set the Application Session Key (AppSKey)
2351 2351  * **##AT+APPEUI##**: Get or set the Application EUI (AppEUI)
2352 2352  * **##AT+ADR##**: Get or set the Adaptive Data Rate setting. (0: OFF, 1: ON)
2353 -* ##**AT+TXP**##: Get or set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Specification)
2354 -* **##AT+DR##**:  Get or set the Data Rate. (0-7 corresponding to DR_X)  
2355 -* **##AT+DCS##**: Get or set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing
2356 -* ##**AT+PNM**##: Get or set the public network mode. (0: off, 1: on)
2357 -* ##**AT+RX2FQ**##: Get or set the Rx2 window frequency
2358 -* ##**AT+RX2DR**##: Get or set the Rx2 window data rate (0-7 corresponding to DR_X)
2359 -* ##**AT+RX1DL**##: Get or set the delay between the end of the Tx and the Rx Window 1 in ms
2360 -* ##**AT+RX2DL**##: Get or set the delay between the end of the Tx and the Rx Window 2 in ms
2361 -* ##**AT+JN1DL**##: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms
2362 -* ##**AT+JN2DL**##: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms
2363 -* ##**AT+NJM**##: Get or set the Network Join Mode. (0: ABP, 1: OTAA)
2364 -* ##**AT+NWKID**##: Get or set the Network ID
2365 -* ##**AT+FCU**##: Get or set the Frame Counter Uplink (FCntUp)
2366 -* ##**AT+FCD**##: Get or set the Frame Counter Downlink (FCntDown)
2367 -* ##**AT+CLASS**##: Get or set the Device Class
2368 -* ##**AT+JOIN**##: Join network
2369 -* ##**AT+NJS**##: Get OTAA Join Status
2370 -* ##**AT+SENDB**##: Send hexadecimal data along with the application port
2371 -* ##**AT+SEND**##: Send text data along with the application port
2372 -* ##**AT+RECVB**##: Print last received data in binary format (with hexadecimal values)
2373 -* ##**AT+RECV**##: Print last received data in raw format
2374 -* ##**AT+VER**##: Get current image version and Frequency Band
2375 -* ##**AT+CFM**##: Get or Set the confirmation mode (0-1)
2376 -* ##**AT+CFS**##: Get confirmation status of the last AT+SEND (0-1)
2377 -* ##**AT+SNR**##: Get the SNR of the last received packet
2378 -* ##**AT+RSSI**##: Get the RSSI of the last received packet
2379 -* ##**AT+TDC**##: Get or set the application data transmission interval in ms
2380 -* ##**AT+PORT**##: Get or set the application port
2381 -* ##**AT+DISAT**##: Disable AT commands
2382 -* ##**AT+PWORD**##: Set password, max 9 digits
2383 -* ##**AT+CHS**##: Get or set the Frequency (Unit: Hz) for Single Channel Mode
2384 -* ##**AT+CHE**##: Get or set eight channels mode, Only for US915, AU915, CN470
2385 -* ##**AT+CFG**##: Print all settings
2205 +* AT+TXP: Get or set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Specification)
2206 +* AT+DR:  Get or set the Data Rate. (0-7 corresponding to DR_X)  
2207 +* AT+DCS: Get or set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing
2208 +* AT+PNM: Get or set the public network mode. (0: off, 1: on)
2209 +* AT+RX2FQ: Get or set the Rx2 window frequency
2210 +* AT+RX2DR: Get or set the Rx2 window data rate (0-7 corresponding to DR_X)
2211 +* AT+RX1DL: Get or set the delay between the end of the Tx and the Rx Window 1 in ms
2212 +* AT+RX2DL: Get or set the delay between the end of the Tx and the Rx Window 2 in ms
2213 +* AT+JN1DL: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms
2214 +* AT+JN2DL: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms
2215 +* AT+NJM: Get or set the Network Join Mode. (0: ABP, 1: OTAA)
2216 +* AT+NWKID: Get or set the Network ID
2217 +* AT+FCU: Get or set the Frame Counter Uplink (FCntUp)
2218 +* AT+FCD: Get or set the Frame Counter Downlink (FCntDown)
2219 +* AT+CLASS: Get or set the Device Class
2220 +* AT+JOIN: Join network
2221 +* AT+NJS: Get OTAA Join Status
2222 +* AT+SENDB: Send hexadecimal data along with the application port
2223 +* AT+SEND: Send text data along with the application port
2224 +* AT+RECVB: Print last received data in binary format (with hexadecimal values)
2225 +* AT+RECV: Print last received data in raw format
2226 +* AT+VER: Get current image version and Frequency Band
2227 +* AT+CFM: Get or Set the confirmation mode (0-1)
2228 +* AT+CFS: Get confirmation status of the last AT+SEND (0-1)
2229 +* AT+SNR: Get the SNR of the last received packet
2230 +* AT+RSSI: Get the RSSI of the last received packet
2231 +* AT+TDC: Get or set the application data transmission interval in ms
2232 +* AT+PORT: Get or set the application port
2233 +* AT+DISAT: Disable AT commands
2234 +* AT+PWORD: Set password, max 9 digits
2235 +* AT+CHS: Get or set the Frequency (Unit: Hz) for Single Channel Mode
2236 +* AT+CHE: Get or set eight channels mode, Only for US915, AU915, CN470
2237 +* AT+CFG: Print all settings
2386 2386  )))
2387 2387  
2388 2388  
... ... @@ -2547,7 +2547,7 @@
2547 2547  You will need the following things before proceeding:
2548 2548  
2549 2549  * 3.5mm programming cable (included with the LT-22222-L as an additional accessory)
2550 -* USB to TTL adapter/converter
2402 +* USB to TTL adapter
2551 2551  * Download and install the [[STM32 Flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. (replaced by STM32CubeProgrammer)
2552 2552  * Download the latest firmware image from [[LT-22222-L firmware image files>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AACrbrDN0AqLHbBat0ViWx5Da/LT-22222-L/Firmware?dl=0&subfolder_nav_tracking=1]]. Check the file name of the firmware to find the correct region.
2553 2553  
... ... @@ -2557,7 +2557,7 @@
2557 2557  
2558 2558  Below is the hardware setup for uploading a firmware image to the LT-22222-L:
2559 2559  
2560 -[[image:usb-ttl-audio-jack-connection.jpg]]
2412 +[[image:usb-ttl-programming.png]]
2561 2561  
2562 2562  
2563 2563  
Screenshot 2024-11-23 at 18.27.11.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.pradeeka
Size
... ... @@ -1,1 +1,0 @@
1 -143.4 KB
Content
dragino-lorawan-nw-lt-22222-n.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.pradeeka
Size
... ... @@ -1,1 +1,0 @@
1 -267.3 KB
Content
dragino-ttn-te.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.pradeeka
Size
... ... @@ -1,1 +1,0 @@
1 -273.8 KB
Content
lorawan-nw.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.pradeeka
Size
... ... @@ -1,1 +1,0 @@
1 -250.6 KB
Content
lt-22222-l-joining.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.pradeeka
Size
... ... @@ -1,1 +1,0 @@
1 -301.9 KB
Content
lt33222-l.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.pradeeka
Size
... ... @@ -1,1 +1,0 @@
1 -31.3 KB
Content
usb-ttl-audio-jack-connection.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.pradeeka
Size
... ... @@ -1,1 +1,0 @@
1 -394.4 KB
Content