Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -246,7 +246,7 @@ 246 246 247 247 (% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L. 248 248 249 - **To use counting mode, please run:**249 +To use counting mode, please run: 250 250 251 251 (% class="box infomessage" %) 252 252 ((( ... ... @@ -310,106 +310,123 @@ 310 310 311 311 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 312 312 313 -**To use counting mode, please run:** 314 314 315 -(% class="box infomessage" %) 316 -((( 317 -**AT+MOD=3** 318 -))) 314 +To use counting mode, please run: 319 319 320 -(% class="box infomessage" %) 321 -((( 322 -**ATZ** 323 -))) 316 +AT+MOD=3 324 324 318 +ATZ 319 + 320 + 325 325 Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:#COUNT_COMMAND]]. 326 326 327 -=== 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 328 328 324 + 325 + 326 +1. 327 +11. 328 +111. AT+MOD=4, Single DI Counting + 1 x Voltage Counting 329 + 330 +**LT33222-L**: This mode the DI3 is used as a counting pin. 331 + 329 329 **LT22222-L**: This mode the DI1 is used as a counting pin. 330 330 334 + 331 331 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. 332 332 333 -[[image:image-20220523181903-8.png]] 334 334 335 -((( 336 -(% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 337 -))) 338 +(% border="1" style="background-color:#f7faff" %) 339 +|Size(bytes)|4|4|1|1|1 340 +|Value|COUNT1|AVI1 Counting|DIDORO*|((( 341 +Reserve 338 338 339 -[[image:image-20220523181727-7.png]] 343 + 344 +)))|MOD 340 340 346 +**DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 347 + 348 +(% border="1" style="background-color:#f7faff" %) 349 +|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 350 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 351 + 341 341 * RO is for relay. ROx=1 : close,ROx=0 always open. 342 342 * FIRST: Indicate this is the first packet after join network. 343 343 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 344 344 345 - (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.356 +Note: DO3 is not valid for LT-22222-L. 346 346 347 -**To use this mode, please run:** 348 348 349 -(% class="box infomessage" %) 350 -((( 351 -**AT+MOD=4** 352 -))) 359 +To use this mode, please run: 353 353 354 -(% class="box infomessage" %) 355 -((( 356 -**ATZ** 357 -))) 361 +AT+MOD=4 358 358 363 +ATZ 359 359 365 + 366 + 360 360 Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:#COUNT_COMMAND]]. 361 361 362 - **Plus below command for AVI1 Counting:**369 +Plus below command for AVI1 Counting: 363 363 364 -(% class="box infomessage" %) 365 -((( 366 -**AT+SETCNT=3,60 (set AVI Count to 60)** 367 -))) 371 +AT+SETCNT=3,60 (set AVI Count to 60) 368 368 369 -(% class="box infomessage" %) 370 -((( 371 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 372 -))) 373 +AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1) 373 373 374 -(% class="box infomessage" %) 375 -((( 376 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 377 -))) 375 +AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1) 378 378 379 -(% class="box infomessage" %) 380 -((( 381 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 382 -))) 377 +AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1) 383 383 384 -=== 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 385 385 380 + 381 +1. 382 +11. 383 +111. AT+MOD=5, Single DI Counting + 2 x AVI + 1 x ACI 384 + 385 +**LT33222-L**: This mode the DI3 is used as a counting pin. 386 + 386 386 **LT22222-L**: This mode the DI1 is used as a counting pin. 387 387 388 -[[image:image-20220523182334-9.png]] 389 389 390 -((( 391 -(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 392 -))) 390 +(% border="1" style="background-color:#f7faff" %) 391 +|Size(bytes)|2|2|2|2|1|1|1 392 +|Value|((( 393 +AVI1 393 393 395 +voltage 396 +)))|((( 397 +AVI2 394 394 399 +voltage 400 +)))|((( 401 +ACI1 402 + 403 +Current 404 +)))|COUNT1|DIDORO*|((( 405 +Reserve 406 + 407 + 408 +)))|MOD 409 + 410 +**DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 411 + 412 +(% border="1" style="background-color:#f7faff" %) 413 +|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 414 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 415 + 395 395 * RO is for relay. ROx=1 : close,ROx=0 always open. 396 396 * FIRST: Indicate this is the first packet after join network. 397 397 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 398 398 399 - (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.420 +Note: DO3 is not valid for LT-22222-L. 400 400 401 -**To use this mode, please run:** 402 402 403 -(% class="box infomessage" %) 404 -((( 405 -**AT+MOD=5** 406 -))) 423 +To use this mode, please run: 407 407 408 -(% class="box infomessage" %) 409 -((( 410 -**ATZ** 411 -))) 425 +AT+MOD=5 412 412 427 +ATZ 428 + 429 + 413 413 Other AT Commands for counting are similar to [[MOD2 Counting Command>>path:#COUNT_COMMAND]]. 414 414 415 415
- image-20220523182334-9.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.4 KB - Content