Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -116,13 +116,13 @@ 116 116 117 117 == 1.5 Hardware Variants == 118 118 119 -(% style="width:5 24px" %)120 -|(% style="width:94px" %)**Model**|(% style="width: 98px" %)**Photo**|(% style="width:329px" %)**Description**121 -|(% style="width:94px" %)**LT33222-L**|(% style="width: 98px" %)(((122 - 123 -)))|(% style="width: 329px" %)(((124 -* 2x Digital Input (Bi-direction)125 -* 2x Digital Output119 +(% style="width:650px" %) 120 +|(% style="width:94px" %)**Model**|(% style="width:172px" %)**Photo**|(% style="width:256px" %)**Description** 121 +|(% style="width:94px" %)**LT-33222-L**|(% style="width:172px" %)((( 122 +[[image:lt33222-l.jpg]] 123 +)))|(% style="width:256px" %)((( 124 +* 3 x Digital Input (Bi-direction) 125 +* 3 x Digital Output 126 126 * 2 x Relay Output (5A@250VAC / 30VDC) 127 127 * 2 x 0~~20mA Analog Input (res:0.01mA) 128 128 * 2 x 0~~30V Analog Input (res:0.01v) ... ... @@ -237,7 +237,7 @@ 237 237 *** **Profile (Region)**: Select the region that matches your device. 238 238 ** Select the **Frequency plan** that matches your device from the **Frequency plan** dropdown list. 239 239 240 -[[image:lt-22222-l-dev-repo-reg-p1.png ||height="625" width="1000"]]240 +[[image:lt-22222-l-dev-repo-reg-p1.png]] 241 241 242 242 243 243 * Register end device page continued... ... ... @@ -247,7 +247,7 @@ 247 247 ** In the **End device ID** field, enter a unique name for your LT-22222-N within this application. 248 248 ** Under **After registration**, select the **View registered end device** option. 249 249 250 -[[image:lt-22222-l-dev-repo-reg-p2.png ||height="625" width="1000"]]250 +[[image:lt-22222-l-dev-repo-reg-p2.png]] 251 251 252 252 253 253 ==== 3.2.2.3 Adding device manually ==== ... ... @@ -261,7 +261,7 @@ 261 261 ** Select the option **Over the air activation (OTAA)** under the **Activation mode.** 262 262 ** Select **Class C (Continuous)** from the **Additional LoRaWAN class capabilities** dropdown list. 263 263 264 -[[image:lt-22222-l-manually-p1.png ||height="625" width="1000"]]264 +[[image:lt-22222-l-manually-p1.png]] 265 265 266 266 267 267 * Register end device page continued... ... ... @@ -272,13 +272,13 @@ 272 272 ** Under **After registration**, select the **View registered end device** option. 273 273 ** Click the **Register end device** button. 274 274 275 -[[image:lt-22222-l-manually-p2.png ||height="625" width="1000"]]275 +[[image:lt-22222-l-manually-p2.png]] 276 276 277 277 278 278 You will be navigated to the **Device overview** page. 279 279 280 280 281 -[[image:lt-22222-device-overview.png ||height="625" width="1000"]]281 +[[image:lt-22222-device-overview.png]] 282 282 283 283 284 284 ==== 3.2.2.4 Joining ==== ... ... @@ -288,9 +288,10 @@ 288 288 Now power on your LT-22222-L. The **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** The Things Stack network server. The **TX LED** will be on for **5 seconds** after joining the network. In the **Live data** panel, you can see the **join-request** and **join-accept** messages exchanged between the device and the network server. 289 289 290 290 291 -[[image:lt-22222-join -network.png||height="625" width="1000"]]291 +[[image:lt-22222-l-joining.png]] 292 292 293 293 294 + 294 294 ==== 3.2.2.5 Uplinks ==== 295 295 296 296 ... ... @@ -307,7 +307,7 @@ 307 307 The Things Stack provides two levels of payload formatters: application level and device level. The device-level payload formatters **override **the application-level payload formatters. 308 308 {{/info}} 309 309 310 -[[image:lt-22222-ul-payload-fmt.png ||height="686" width="1000"]]311 +[[image:lt-22222-ul-payload-fmt.png]] 311 311 312 312 313 313 ==== 3.2.2.6 Downlinks ==== ... ... @@ -598,11 +598,11 @@ 598 598 599 599 (% style="color:blue" %)**AT+SETCNT=3,60 **(%%)**(Sets AVI1 Count to 60)** 600 600 601 -(% style="color:blue" %)**AT+VOLMAX=20000 **(%%)**(If AVI1 voltage higher than VOLMAX (20000mV =20 v), counter increase 1)**602 +(% style="color:blue" %)**AT+VOLMAX=20000 **(%%)**(If the AVI1 voltage is higher than VOLMAX (20000mV =20V), the counter increases by 1)** 602 602 603 -(% style="color:blue" %)**AT+VOLMAX=20000,0 **(%%)**(If AVI1 voltage lower than VOLMAX (20000mV =20 v), counter increase 1)**604 +(% style="color:blue" %)**AT+VOLMAX=20000,0 **(%%)**(If the AVI1 voltage is lower than VOLMAX (20000mV =20V), counter increases by 1)** 604 604 605 -(% style="color:blue" %)**AT+VOLMAX=20000,1 **(%%)**(If AVI1 voltage higher than VOLMAX (20000mV =20 v), counter increase 1)**606 +(% style="color:blue" %)**AT+VOLMAX=20000,1 **(%%)**(If the AVI1 voltage is higher than VOLMAX (20000mV =20V), counter increases by 1)** 606 606 ))) 607 607 608 608 ... ... @@ -721,9 +721,9 @@ 721 721 722 722 (% style="color:#037691" %)**LoRaWAN Downlink Commands for Setting the Trigger Conditions:** 723 723 724 -Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 725 +**Type Code**: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 725 725 726 -Format: AA xx yy1 yy1 yy2 yy2 yy3 yy3 yy4 yy4 727 +**Format**: AA xx yy1 yy1 yy2 yy2 yy3 yy3 yy4 yy4 727 727 728 728 AA: Type Code for this downlink Command: 729 729 ... ... @@ -790,7 +790,7 @@ 790 790 791 791 **Example:** 792 792 793 -10100000: Means the systemhas configure to use the trigger:AV1_LOW and AV2_LOW794 +10100000: This means the system is configured to use the triggers AV1_LOW and AV2_LOW. 794 794 795 795 796 796 (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1 byte as below ... ... @@ -819,7 +819,7 @@ 819 819 820 820 **Example:** 821 821 822 -10000000: Meansthisuplink is triggered by AV1_LOW.Thatmeansthe voltage is too low.823 +10000000: The uplink is triggered by AV1_LOW, indicating that the voltage is too low. 823 823 824 824 825 825 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below ... ... @@ -828,22 +828,22 @@ 828 828 |(% style="width:64px" %)**bit 7**|(% style="width:68px" %)**bit 6**|(% style="width:63px" %)**bit 5**|(% style="width:66px" %)**bit 4**|(% style="width:109px" %)**bit 3**|(% style="width:93px" %)**bit 2**|(% style="width:109px" %)**bit 1**|(% style="width:99px" %)**bit 0** 829 829 |(% style="width:64px" %)N/A|(% style="width:68px" %)N/A|(% style="width:63px" %)N/A|(% style="width:66px" %)N/A|(% style="width:109px" %)DI2_STATUS|(% style="width:93px" %)DI2_FLAG|(% style="width:109px" %)DI1_STATUS|(% style="width:99px" %)DI1_FLAG 830 830 831 -* Each bit sshows which status has been triggered on this uplink.832 +* Each bit shows which status has been triggered on this uplink. 832 832 833 833 **Example:** 834 834 835 -00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.836 +00000111: This means both DI1 and DI2 triggers are enabled, and this packet is trigger by DI1. 836 836 837 -00000101: Means both DI1 and DI2 trigger are enabled.838 +00000101: This means both DI1 and DI2 triggers are enabled. 838 838 839 839 840 -(% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 841 +(% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enabled. 0x00: MOD6 is disabled. 841 841 842 -Downlink command to poll MOD6 status: 843 +Downlink command to poll/request MOD6 status: 843 843 844 844 **AB 06** 845 845 846 -When device gotthis command, it will send the MOD6 payload.847 +When device receives this command, it will send the MOD6 payload. 847 847 848 848 849 849 === 3.3.7 Payload Decoder === ... ... @@ -967,7 +967,7 @@ 967 967 Sets the device to working mode 2 (Double DI Counting + DO + RO) 968 968 ))) 969 969 970 -==== 3.4.2.3 Pollan uplink ====971 +==== 3.4.2.3 Request an uplink from the device ==== 971 971 972 972 Requests an uplink from LT-22222-L. The content of the uplink payload varies based on the device's current working mode. 973 973 ... ... @@ -1023,9 +1023,9 @@ 1023 1023 Enable trigger mode for the current working mode 1024 1024 ))) 1025 1025 1026 -==== 3.4.2.5 Polltrigger settings ====1027 +==== 3.4.2.5 Request trigger settings ==== 1027 1027 1028 - Polls the trigger settings.1029 +Requests the trigger settings. 1029 1029 1030 1030 (% style="color:#037691" %)**AT Command:** 1031 1031 ... ... @@ -1355,25 +1355,23 @@ 1355 1355 1356 1356 * (% style="color:#037691" %)**AT Command** 1357 1357 1358 -There is no AT Command to controlDigitalOutput1359 +There is no AT command to control the digital output. 1359 1359 1360 1360 1361 1361 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)** 1362 1362 1363 -(% style="color:blue" %)**0xA9 aa bb cc **(%%) ~/~/ Set DO1/DO2/DO3 output with time control 1364 +(% style="color:blue" %)**0xA9 aa bb cc **(%%) ~/~/ Sets DO1/DO2/DO3 outputs with time control 1364 1364 1365 - 1366 1366 This is to control the digital output time of DO pin. Include four bytes: 1367 1367 1368 -(% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9)1368 +(% style="color:#4f81bd" %)**First byte**(%%)**:** Type code (0xA9) 1369 1369 1370 -(% style="color:#4f81bd" %)**Second Byte**(%%): Inverter Mode1370 +(% style="color:#4f81bd" %)**Second byte**(%%): Inverter Mode 1371 1371 1372 -01: DO pins will change back to original state after timeout. 1372 +**01:** DO pins revert to their original state after the timeout. 1373 +**00:** DO pins switch to an inverted state after the timeout. 1373 1373 1374 -00: DO pins will change to an inverter state after timeout 1375 1375 1376 - 1377 1377 (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Port status: 1378 1378 1379 1379 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) ... ... @@ -1382,7 +1382,7 @@ 1382 1382 |0x00|DO1 set to high 1383 1383 |0x11|DO1 NO Action 1384 1384 1385 -(% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Port status:1384 +(% style="color:#4f81bd" %)**Fourth byte**(%%): Control Method and Port status: 1386 1386 1387 1387 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1388 1388 |(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status** ... ... @@ -1390,7 +1390,7 @@ 1390 1390 |0x00|DO2 set to high 1391 1391 |0x11|DO2 NO Action 1392 1392 1393 -(% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Port status:1392 +(% style="color:#4f81bd" %)**Fifth byte**(%%): Control Method and Port status: 1394 1394 1395 1395 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1396 1396 |(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status** ... ... @@ -1398,7 +1398,7 @@ 1398 1398 |0x00|DO3 set to high 1399 1399 |0x11|DO3 NO Action 1400 1400 1401 -(% style="color:#4f81bd" %)**Sixth, Seventh, Eighth, and Ninth Bytes**:(%%) Latching time (Unit: ms)1400 +(% style="color:#4f81bd" %)**Sixth, Seventh, Eighth, and Ninth bytes**:(%%) Latching time (Unit: ms) 1402 1402 1403 1403 1404 1404 (% style="color:red" %)**Note: ** ... ... @@ -1407,7 +1407,7 @@ 1407 1407 1408 1408 Before firmware v1.6.0, the latch time only supported 2 bytes. 1409 1409 1410 -(% style="color:red" %)** Device will uploada packet if the downlink code executes successfully.**1409 +(% style="color:red" %)**The device will uplink a packet if the downlink code executes successfully.** 1411 1411 1412 1412 1413 1413 **Example payload:** ... ... @@ -1434,16 +1434,16 @@ 1434 1434 1435 1435 * (% style="color:#037691" %)**AT Command:** 1436 1436 1437 -There is no AT Command to control Relay Output 1436 +There is no AT Command to control the Relay Output 1438 1438 1439 1439 1440 1440 * (% style="color:#037691" %)**Downlink Payload (prefix 0x03):** 1441 1441 1442 -(% style="color:blue" %)**0x03 aa bb ** (%%)~/~/ Set RO1/RO2 output 1441 +(% style="color:blue" %)**0x03 aa bb ** (%%)~/~/ Sets RO1/RO2 output 1443 1443 1444 1444 1445 1445 ((( 1446 -If payload is 0x030100, it means setting RO1 to close and RO2 to open. 1445 +If the payload is 0x030100, it means setting RO1 to close and RO2 to open. 1447 1447 ))) 1448 1448 1449 1449 ((( ... ... @@ -1461,7 +1461,7 @@ 1461 1461 |03 00 01|Open|Close 1462 1462 ))) 1463 1463 1464 -(% style="color:red" %)** Device will uploada packet if downlink code executes successfully.**1463 +(% style="color:red" %)**The device will uplink a packet if the downlink code executes successfully.** 1465 1465 1466 1466 1467 1467 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== ... ... @@ -1470,19 +1470,19 @@ 1470 1470 1471 1471 * (% style="color:#037691" %)**AT Command:** 1472 1472 1473 -There is no AT Command to control Relay Output 1472 +There is no AT Command to control the Relay Output 1474 1474 1475 1475 1476 1476 * (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1477 1477 1478 -(% style="color:blue" %)**0x05 aa bb cc dd ** (%%)~/~/ Set RO1/RO2 relay with time control 1477 +(% style="color:blue" %)**0x05 aa bb cc dd ** (%%)~/~/ Sets RO1/RO2 relays with time control 1479 1479 1480 1480 1481 -This is tocontrol the relay output time.Itincludesfourbytes:1480 +This controls the relay output time and includes 4 bytes: 1482 1482 1483 -(% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05)1482 +(% style="color:#4f81bd" %)**First byte **(%%)**:** Type code (0x05) 1484 1484 1485 -(% style="color:#4f81bd" %)**Second Byte(aa)**(%%): Inverter Mode1484 +(% style="color:#4f81bd" %)**Second byte (aa)**(%%): Inverter Mode 1486 1486 1487 1487 01: Relays will change back to their original state after timeout. 1488 1488 ... ... @@ -1489,12 +1489,12 @@ 1489 1489 00: Relays will change to the inverter state after timeout. 1490 1490 1491 1491 1492 -(% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:1491 +(% style="color:#4f81bd" %)**Third byte (bb)**(%%): Control Method and Ports status: 1493 1493 1494 1494 [[image:image-20221008095908-1.png||height="364" width="564"]] 1495 1495 1496 1496 1497 -(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms1496 +(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh bytes (cc)**(%%): Latching time. Unit: ms 1498 1498 1499 1499 1500 1500 (% style="color:red" %)**Note:** ... ... @@ -1504,7 +1504,7 @@ 1504 1504 Before firmware v1.6.0, the latch time only supported 2 bytes. 1505 1505 1506 1506 1507 -(% style="color:red" %)** Device will uploada packet if the downlink code executes successfully.**1506 +(% style="color:red" %)**The device will uplink a packet if the downlink code executes successfully.** 1508 1508 1509 1509 1510 1510 **Example payload:** ... ... @@ -1663,7 +1663,7 @@ 1663 1663 ))) 1664 1664 |(% style="width:141px" %)**Example**|(% style="width:357px" %)A6 **01** 1665 1665 1666 -==== 3.4.2.19 Counting ~-~- Changecountingmodetosavetime====1665 +==== 3.4.2.19 Counting ~-~- Set Saving Interval for 'Counting Result' ==== 1667 1667 1668 1668 This command allows you to configure the device to save its counting result to internal flash memory at specified intervals. By setting a save time, the device will periodically store the counting data to prevent loss in case of power failure. The save interval can be adjusted to suit your requirements, with a minimum value of 30 seconds. 1669 1669 ... ... @@ -1694,7 +1694,7 @@ 1694 1694 Sets the device to save its counting results to the memory every 60 seconds. 1695 1695 ))) 1696 1696 1697 -==== 3.4.2.20 Reset save RO DO state ==== 1696 +==== 3.4.2.20 Reset saved RO and DO states ==== 1698 1698 1699 1699 This command allows you to reset the saved relay output (RO) and digital output (DO) states when the device joins the network. By configuring this setting, you can control whether the device should retain or reset the relay states after a reset and rejoin to the network. 1700 1700 ... ... @@ -1951,7 +1951,7 @@ 1951 1951 The username and password (API key) you created here are required in the next section. 1952 1952 {{/info}} 1953 1953 1954 -[[image:tts-mqtt-integration.png ||height="625" width="1000"]]1953 +[[image:tts-mqtt-integration.png]] 1955 1955 1956 1956 === 3.5.2 Configuring ThingsEye.io === 1957 1957 ... ... @@ -1961,7 +1961,7 @@ 1961 1961 * Under the **Integrations center**, click **Integrations**. 1962 1962 * Click the **Add integration** button (the button with the **+** symbol). 1963 1963 1964 -[[image:thingseye-io-step-1.png ||height="625" width="1000"]]1963 +[[image:thingseye-io-step-1.png]] 1965 1965 1966 1966 1967 1967 On the **Add integration** window, configure the following: ... ... @@ -1976,7 +1976,7 @@ 1976 1976 ** Allow create devices or assets 1977 1977 * Click the **Next** button. you will be navigated to the **Uplink data converter** tab. 1978 1978 1979 -[[image:thingseye-io-step-2.png ||height="625" width="1000"]]1978 +[[image:thingseye-io-step-2.png]] 1980 1980 1981 1981 1982 1982 **Uplink data converter:** ... ... @@ -1987,7 +1987,7 @@ 1987 1987 * Paste the uplink decoder function into the text area (first, delete the default code). The demo uplink decoder function can be found [[here>>https://raw.githubusercontent.com/ThingsEye-io/te-platform/refs/heads/main/Data%20Converters/The_Things_Network_MQTT_Uplink_Converter.js]]. 1988 1988 * Click the **Next** button. You will be navigated to the **Downlink data converter **tab. 1989 1989 1990 -[[image:thingseye-io-step-3.png ||height="625" width="1000"]]1989 +[[image:thingseye-io-step-3.png]] 1991 1991 1992 1992 1993 1993 **Downlink data converter (this is an optional step):** ... ... @@ -1998,7 +1998,7 @@ 1998 1998 * Paste the downlink decoder function into the text area (first, delete the default code). The demo downlink decoder function can be found [[here>>https://raw.githubusercontent.com/ThingsEye-io/te-platform/refs/heads/main/Data%20Converters/The_Things_Network_MQTT_Downlink_Converter.js]]. 1999 1999 * Click the **Next** button. You will be navigated to the **Connection** tab. 2000 2000 2001 -[[image:thingseye-io-step-4.png ||height="625" width="1000"]]2000 +[[image:thingseye-io-step-4.png]] 2002 2002 2003 2003 2004 2004 **Connection:** ... ... @@ -2013,13 +2013,13 @@ 2013 2013 2014 2014 * Click the **Add** button. 2015 2015 2016 -[[image:thingseye-io-step-5.png ||height="625" width="1000"]]2015 +[[image:thingseye-io-step-5.png]] 2017 2017 2018 2018 2019 2019 Your integration has been added to the** Integrations** list and will be displayed on the **Integrations** page. Check whether the status is shown as **Active**. If not, review your configuration settings and correct any errors. 2020 2020 2021 2021 2022 -[[image:thingseye.io_integrationsCenter_integrations.png ||height="686" width="1000"]]2021 +[[image:thingseye.io_integrationsCenter_integrations.png]] 2023 2023 2024 2024 2025 2025 ==== 3.5.2.1 Viewing integration details ==== ... ... @@ -2026,7 +2026,7 @@ 2026 2026 2027 2027 Click on your integration from the list. The **Integration details** window will appear with the **Details **tab selected. The **Details **tab shows all the settings you have provided for this integration. 2028 2028 2029 -[[image:integration-details.png ||height="686" width="1000"]]2028 +[[image:integration-details.png]] 2030 2030 2031 2031 2032 2032 If you want to edit the settings you have provided, click on the **Toggle edit mode** button. Once you have done click on the **Apply changes **button. ... ... @@ -2042,12 +2042,12 @@ 2042 2042 * Select **Debug **from the **Event type** dropdown. 2043 2043 * Select the** time frame** from the **time window**. 2044 2044 2045 -[[image:thingseye-events.png ||height="686" width="1000"]]2044 +[[image:thingseye-events.png]] 2046 2046 2047 2047 2048 2048 * To view the **JSON payload** of a message, click on the **three dots (...)** in the Message column of the desired message. 2049 2049 2050 -[[image:thingseye-json.png ||width="1000"]]2049 +[[image:thingseye-json.png]] 2051 2051 2052 2052 2053 2053 ==== **3.5.2.3 Deleting an integration** ==== ... ... @@ -2065,7 +2065,7 @@ 2065 2065 === 3.6.1 Digital Input Ports: DI1/DI2/DI3 (For LT-33222-L, Low Active) === 2066 2066 2067 2067 2068 -Supports** 2067 +Supports** NPN-type **sensors. 2069 2069 2070 2070 [[image:1653356991268-289.png]] 2071 2071
- lt-22222-l-joining.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +301.9 KB - Content
- lt33222-l.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.3 KB - Content