Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -969,11 +969,11 @@ 969 969 970 970 ==== 3.4.2.3 Poll an uplink ==== 971 971 972 -Requests an uplink from LT-22222-L. The content of the uplink payload varies based on the device's current working mode.972 +Requests an uplink from LT-22222-L. 973 973 974 974 (% style="color:#037691" %)**AT command** 975 975 976 -There is no AT Command available forthisfeature.976 +There is no AT Command to request an uplink from LT-22222-L 977 977 978 978 (% style="color:#037691" %)**Downlink payload** 979 979 ... ... @@ -981,7 +981,7 @@ 981 981 |(% style="width:101px" %)**Payload**|(% style="width:397px" %)<prefix>FF 982 982 |(% style="width:101px" %)**Parameters**|(% style="width:397px" %)**prefix** : 0x08 983 983 |(% style="width:101px" %)**Example**|(% style="width:397px" %)((( 984 -08 **FF**984 +08 FF 985 985 986 986 Requests an uplink from LT-22222-L. 987 987 ))) ... ... @@ -1015,7 +1015,7 @@ 1015 1015 |(% style="width:97px" %)**Parameters**|(% style="width:401px" %)((( 1016 1016 **prefix** : 0x0A 06 (two bytes in hexadecimal) 1017 1017 1018 -** enable/disable trigger_mode** : enable (1) or disable (0), represented by 1 byte in hexadecimal.1018 +**working mode** : enable (1) or disable (0), represented by 1 byte in hexadecimal. 1019 1019 ))) 1020 1020 |(% style="width:97px" %)**Example**|(% style="width:401px" %)((( 1021 1021 0A 06 **01** ... ... @@ -1029,7 +1029,7 @@ 1029 1029 1030 1030 (% style="color:#037691" %)**AT Command:** 1031 1031 1032 -There is no AT Command availablefor this feature.1032 +There is no AT Command for this feature. 1033 1033 1034 1034 (% style="color:#037691" %)**Downlink Payload** 1035 1035 ... ... @@ -1169,6 +1169,7 @@ 1169 1169 ))) 1170 1170 |(% style="width:96px" %)**Example**|(% style="width:402px" %)09 02 **00 00 64** 1171 1171 1172 + 1172 1172 ==== 3.4.2.9 Trigger – Set AC (current) as a trigger ==== 1173 1173 1174 1174 Sets the current trigger based on the AC port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -1350,6 +1350,7 @@ 1350 1350 ))) 1351 1351 ))) 1352 1352 1354 + 1353 1353 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1354 1354 1355 1355 ... ... @@ -1532,10 +1532,17 @@ 1532 1532 1533 1533 When the voltage exceeds the threshold, counting begins. For details, see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1534 1534 1537 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+VOLMAX ** (%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1538 + 1539 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1540 + 1541 +(% style="color:blue" %)**0xA5 aa bb cc ** (%%)~/~/ Same as AT+VOLMAX=(aa bb),cc 1542 + 1543 + 1535 1535 (% style="color:#037691" %)**AT Command** 1536 1536 1537 1537 (% border="2" style="width:500px" %) 1538 -|(% style="width:137px" %)**Command**|(% style="width:361px" %)AT+VOLMAX=<voltage> ,<logic>1547 +|(% style="width:137px" %)**Command**|(% style="width:361px" %)AT+VOLMAX=<voltage><logic> 1539 1539 |(% style="width:137px" %)**Response**|(% style="width:361px" %) 1540 1540 |(% style="width:137px" %)**Parameters**|(% style="width:361px" %)((( 1541 1541 **voltage** : voltage threshold in mV ... ... @@ -1542,9 +1542,9 @@ 1542 1542 1543 1543 **logic**: 1544 1544 1545 - **0**: lower than1554 +0 : lower than 1546 1546 1547 - **1**: higher than1556 +1: higher than 1548 1548 1549 1549 if you leave logic parameter blank, it is considered 0 1550 1550 ))) ... ... @@ -1573,9 +1573,9 @@ 1573 1573 1574 1574 **logic**: (1 byte in hexadecimal) 1575 1575 1576 - **0**: lower than1585 +0 : lower than 1577 1577 1578 - **1**: higher than1587 +1: higher than 1579 1579 1580 1580 if you leave logic parameter blank, it is considered 1 (higher than) 1581 1581 ))) ... ... @@ -1597,10 +1597,22 @@ 1597 1597 1598 1598 This command allows users to pre-configure specific count numbers for various counting parameters such as Count1, Count2, or AVI1 Count. Use the AT command to set the desired count number for each configuration. 1599 1599 1609 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) ** 1610 + 1611 +(% style="color:red" %)**aa:**(%%) 1: Set count1; 2: Set count2; 3: Set AV1 count 1612 + 1613 +(% style="color:red" %)**bb cc dd ee: **(%%)The number to be set 1614 + 1615 + 1616 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1617 + 1618 +(% style="color:blue" %)**0x A8 aa bb cc dd ee ** (%%)~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1619 + 1620 + 1600 1600 (% style="color:#037691" %)**AT Command** 1601 1601 1602 1602 (% border="2" style="width:500px" %) 1603 -|(% style="width:134px" %)**Command**|(% style="width:364px" %)AT+SETCNT=<counting_parameter> ,<number>1624 +|(% style="width:134px" %)**Command**|(% style="width:364px" %)AT+SETCNT=<counting_parameter><number> 1604 1604 |(% style="width:134px" %)**Response**|(% style="width:364px" %) 1605 1605 |(% style="width:134px" %)**Parameters**|(% style="width:364px" %)((( 1606 1606 **counting_parameter** : ... ... @@ -1646,6 +1646,12 @@ 1646 1646 1647 1647 This command clears the counting in counting mode. 1648 1648 1670 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+CLRCOUNT **(%%) ~/~/ clear all counting 1671 + 1672 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1673 + 1674 +(% style="color:blue" %)**0x A6 01 ** (%%)~/~/ clear all counting 1675 + 1649 1649 (% style="color:#037691" %)**AT Command** 1650 1650 1651 1651 (% border="2" style="width:500px" %) ... ... @@ -1667,6 +1667,20 @@ 1667 1667 1668 1668 This command allows you to configure the device to save its counting result to internal flash memory at specified intervals. By setting a save time, the device will periodically store the counting data to prevent loss in case of power failure. The save interval can be adjusted to suit your requirements, with a minimum value of 30 seconds. 1669 1669 1697 +* (% style="color:#037691" %)**AT Command:** 1698 + 1699 +(% style="color:blue" %)**AT+COUTIME=60 **(%%)~/~/ Sets the save time to 60 seconds. The device will save the counting result in internal flash every 60 seconds. (Min value: 30 seconds) 1700 + 1701 + 1702 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1703 + 1704 +(% style="color:blue" %)**0x A7 aa bb cc ** (%%)~/~/ same as AT+COUTIME =aa bb cc, 1705 + 1706 +((( 1707 +Range: aa bb cc:0 to 16777215, (unit: seconds) 1708 +))) 1709 + 1710 + 1670 1670 (% style="color:#037691" %)**AT Command** 1671 1671 1672 1672 (% border="2" style="width:500px" %) ... ... @@ -1698,8 +1698,18 @@ 1698 1698 1699 1699 This command allows you to reset the saved relay output (RO) and digital output (DO) states when the device joins the network. By configuring this setting, you can control whether the device should retain or reset the relay states after a reset and rejoin to the network. 1700 1700 1701 -(% style="color:#037691" %)**AT Command** 1742 +* (% style="color:#037691" %)**AT Command:** 1702 1702 1744 +(% style="color:blue" %)**AT+RODORESET=1 **(%%)~/~/ RODO will close when the device joining the network. (default) 1745 + 1746 +(% style="color:blue" %)**AT+RODORESET=0 **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state will not change when the device reconnects to the network. 1747 + 1748 + 1749 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** 1750 + 1751 +(% style="color:blue" %)**0x AD aa ** (%%)~/~/ same as AT+RODORET =aa 1752 + 1753 + 1703 1703 (% border="2" style="width:500px" %) 1704 1704 |(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+RODORESET=<state> 1705 1705 |(% style="width:127px" %)**Response**|(% style="width:371px" %) ... ... @@ -1720,9 +1720,6 @@ 1720 1720 After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network. 1721 1721 ))) 1722 1722 1723 - 1724 -(% style="color:#037691" %)**Downlink Payload** 1725 - 1726 1726 (% border="2" style="width:500px" %) 1727 1727 |(% style="width:127px" %)**Payload**|(% style="width:371px" %)<prefix><state> 1728 1728 |(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( ... ... @@ -1748,17 +1748,22 @@ 1748 1748 1749 1749 This command allows you to configure whether the device should upload data in an encrypted format or in plaintext. By default, the device encrypts the payload before uploading. You can toggle this setting to either upload encrypted data or transmit it without encryption. 1750 1750 1751 -(% style="color:#037691" %)**AT Command:** 1799 +* (% style="color:#037691" %)**AT Command:** 1752 1752 1801 +(% style="color:blue" %)**AT+DECRYPT=1 ** (%%)~/~/ The payload is uploaded without encryption 1802 + 1803 +(% style="color:blue" %)**AT+DECRYPT=0 **(%%)~/~/ Encrypt when uploading payload (default) 1804 + 1805 + 1753 1753 (% border="2" style="width:500px" %) 1754 1754 |(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+DECRYPT=<state> 1755 1755 |(% style="width:127px" %)**Response**|(% style="width:371px" %) 1756 1756 |(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( 1757 - **state**:1810 +state : 1758 1758 1759 - **1**: The payload is uploaded without encryption1812 +1 : The payload is uploaded without encryption 1760 1760 1761 - **0**: The payload is encrypted when uploaded (default)1814 +0 : The payload is encrypted when uploaded (default) 1762 1762 ))) 1763 1763 |(% style="width:127px" %)**Example**|(% style="width:371px" %)((( 1764 1764 AT+DECRYPT=1 ... ... @@ -1777,8 +1777,13 @@ 1777 1777 1778 1778 This command allows you to retrieve and optionally uplink sensor readings through the serial port. 1779 1779 1780 -(% style="color:#037691" %)**AT Command** 1833 +* (% style="color:#037691" %)**AT Command:** 1781 1781 1835 +(% style="color:blue" %)**AT+GETSENSORVALUE=0 **(%%)~/~/ The serial port retrieves the reading of the current sensor. 1836 + 1837 +(% style="color:blue" %)**AT+GETSENSORVALUE=1 **(%%)~/~/ The serial port retrieves the current sensor reading and uploads it. 1838 + 1839 + 1782 1782 (% border="2" style="width:500px" %) 1783 1783 |(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+GETSENSORVALUE=<state> 1784 1784 |(% style="width:127px" %)**Response**|(% style="width:371px" %) ... ... @@ -1806,8 +1806,13 @@ 1806 1806 1807 1807 This command manages how the node handles mismatched downlink packet counts. It offers two modes: one disables the reception of further downlink packets if discrepancies occur, while the other resets the downlink packet count to align with the server, ensuring continued communication. 1808 1808 1809 -(% style="color:#037691" %)**AT Command** 1867 +* (% style="color:#037691" %)**AT Command:** 1810 1810 1869 +(% style="color:blue" %)**AT+DISFCNTCHECK=0 **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1870 + 1871 +(% style="color:blue" %)**AT+DISFCNTCHECK=1 **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count. 1872 + 1873 + 1811 1811 (% border="2" style="width:500px" %) 1812 1812 |(% style="width:130px" %)**Command**|(% style="width:368px" %)AT+DISFCNTCHECK=<state> 1813 1813 |(% style="width:130px" %)**Response**|(% style="width:368px" %)((( ... ... @@ -1839,6 +1839,17 @@ 1839 1839 1840 1840 This command controls the behavior of the node when the combined size of the MAC commands (MACANS) from the server and the payload exceeds the allowed byte limit for the current data rate (DR). The command provides two modes: one enables splitting the data into batches to ensure compliance with the byte limit, while the other prioritizes the payload and ignores the MACANS in cases of overflow. 1841 1841 1905 +* (% style="color:#037691" %)**AT Command:** 1906 + 1907 +(% style="color:blue" %)**AT+DISMACANS=0** (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default) 1908 + 1909 +(% style="color:blue" %)**AT+DISMACANS=1** (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1910 + 1911 + 1912 +* (% style="color:#037691" %)**Downlink Payload **(%%)**:** 1913 + 1914 +(% style="color:blue" %)**0x21 00 01 ** (%%) ~/~/ Set the DISMACANS=1 1915 + 1842 1842 (% style="color:#037691" %)**AT Command** 1843 1843 1844 1844 (% border="2" style="width:500px" %)