Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (1 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -237,7 +237,7 @@ 237 237 *** **Profile (Region)**: Select the region that matches your device. 238 238 ** Select the **Frequency plan** that matches your device from the **Frequency plan** dropdown list. 239 239 240 -[[image:lt-22222-l-dev-repo-reg-p1.png ||height="625" width="1000"]]240 +[[image:lt-22222-l-dev-repo-reg-p1.png]] 241 241 242 242 243 243 * Register end device page continued... ... ... @@ -247,7 +247,7 @@ 247 247 ** In the **End device ID** field, enter a unique name for your LT-22222-N within this application. 248 248 ** Under **After registration**, select the **View registered end device** option. 249 249 250 -[[image:lt-22222-l-dev-repo-reg-p2.png ||height="625" width="1000"]]250 +[[image:lt-22222-l-dev-repo-reg-p2.png]] 251 251 252 252 253 253 ==== 3.2.2.3 Adding device manually ==== ... ... @@ -261,7 +261,7 @@ 261 261 ** Select the option **Over the air activation (OTAA)** under the **Activation mode.** 262 262 ** Select **Class C (Continuous)** from the **Additional LoRaWAN class capabilities** dropdown list. 263 263 264 -[[image:lt-22222-l-manually-p1.png ||height="625" width="1000"]]264 +[[image:lt-22222-l-manually-p1.png]] 265 265 266 266 267 267 * Register end device page continued... ... ... @@ -272,13 +272,13 @@ 272 272 ** Under **After registration**, select the **View registered end device** option. 273 273 ** Click the **Register end device** button. 274 274 275 -[[image:lt-22222-l-manually-p2.png ||height="625" width="1000"]]275 +[[image:lt-22222-l-manually-p2.png]] 276 276 277 277 278 278 You will be navigated to the **Device overview** page. 279 279 280 280 281 -[[image:lt-22222-device-overview.png ||height="625" width="1000"]]281 +[[image:lt-22222-device-overview.png]] 282 282 283 283 284 284 ==== 3.2.2.4 Joining ==== ... ... @@ -288,9 +288,10 @@ 288 288 Now power on your LT-22222-L. The **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** The Things Stack network server. The **TX LED** will be on for **5 seconds** after joining the network. In the **Live data** panel, you can see the **join-request** and **join-accept** messages exchanged between the device and the network server. 289 289 290 290 291 -[[image:lt-22222-join -network.png||height="625" width="1000"]]291 +[[image:lt-22222-l-joining.png]] 292 292 293 293 294 + 294 294 ==== 3.2.2.5 Uplinks ==== 295 295 296 296 ... ... @@ -307,7 +307,7 @@ 307 307 The Things Stack provides two levels of payload formatters: application level and device level. The device-level payload formatters **override **the application-level payload formatters. 308 308 {{/info}} 309 309 310 -[[image:lt-22222-ul-payload-fmt.png ||height="686" width="1000"]]311 +[[image:lt-22222-ul-payload-fmt.png]] 311 311 312 312 313 313 ==== 3.2.2.6 Downlinks ==== ... ... @@ -969,11 +969,11 @@ 969 969 970 970 ==== 3.4.2.3 Poll an uplink ==== 971 971 972 -Requests an uplink from LT-22222-L. 973 +Requests an uplink from LT-22222-L. The content of the uplink payload varies based on the device's current working mode. 973 973 974 974 (% style="color:#037691" %)**AT command** 975 975 976 -There is no AT Command torequestan uplinkfrom LT-22222-L977 +There is no AT Command available for this feature. 977 977 978 978 (% style="color:#037691" %)**Downlink payload** 979 979 ... ... @@ -981,7 +981,7 @@ 981 981 |(% style="width:101px" %)**Payload**|(% style="width:397px" %)<prefix>FF 982 982 |(% style="width:101px" %)**Parameters**|(% style="width:397px" %)**prefix** : 0x08 983 983 |(% style="width:101px" %)**Example**|(% style="width:397px" %)((( 984 -08 FF 985 +08 **FF** 985 985 986 986 Requests an uplink from LT-22222-L. 987 987 ))) ... ... @@ -1015,7 +1015,7 @@ 1015 1015 |(% style="width:97px" %)**Parameters**|(% style="width:401px" %)((( 1016 1016 **prefix** : 0x0A 06 (two bytes in hexadecimal) 1017 1017 1018 -** working1019 +**enable/disable trigger_mode** : enable (1) or disable (0), represented by 1 byte in hexadecimal. 1019 1019 ))) 1020 1020 |(% style="width:97px" %)**Example**|(% style="width:401px" %)((( 1021 1021 0A 06 **01** ... ... @@ -1029,7 +1029,7 @@ 1029 1029 1030 1030 (% style="color:#037691" %)**AT Command:** 1031 1031 1032 -There is no AT Command for this feature. 1033 +There is no AT Command available for this feature. 1033 1033 1034 1034 (% style="color:#037691" %)**Downlink Payload** 1035 1035 ... ... @@ -1169,7 +1169,6 @@ 1169 1169 ))) 1170 1170 |(% style="width:96px" %)**Example**|(% style="width:402px" %)09 02 **00 00 64** 1171 1171 1172 - 1173 1173 ==== 3.4.2.9 Trigger – Set AC (current) as a trigger ==== 1174 1174 1175 1175 Sets the current trigger based on the AC port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -1351,7 +1351,6 @@ 1351 1351 ))) 1352 1352 ))) 1353 1353 1354 - 1355 1355 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1356 1356 1357 1357 ... ... @@ -1534,17 +1534,10 @@ 1534 1534 1535 1535 When the voltage exceeds the threshold, counting begins. For details, see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1536 1536 1537 -* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+VOLMAX ** (%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1538 - 1539 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1540 - 1541 -(% style="color:blue" %)**0xA5 aa bb cc ** (%%)~/~/ Same as AT+VOLMAX=(aa bb),cc 1542 - 1543 - 1544 1544 (% style="color:#037691" %)**AT Command** 1545 1545 1546 1546 (% border="2" style="width:500px" %) 1547 -|(% style="width:137px" %)**Command**|(% style="width:361px" %)AT+VOLMAX=<voltage><logic> 1539 +|(% style="width:137px" %)**Command**|(% style="width:361px" %)AT+VOLMAX=<voltage>,<logic> 1548 1548 |(% style="width:137px" %)**Response**|(% style="width:361px" %) 1549 1549 |(% style="width:137px" %)**Parameters**|(% style="width:361px" %)((( 1550 1550 **voltage** : voltage threshold in mV ... ... @@ -1551,9 +1551,9 @@ 1551 1551 1552 1552 **logic**: 1553 1553 1554 -0 : lower than 1546 +**0** : lower than 1555 1555 1556 -1: higher than 1548 +**1**: higher than 1557 1557 1558 1558 if you leave logic parameter blank, it is considered 0 1559 1559 ))) ... ... @@ -1582,9 +1582,9 @@ 1582 1582 1583 1583 **logic**: (1 byte in hexadecimal) 1584 1584 1585 -0 : lower than 1577 +**0** : lower than 1586 1586 1587 -1: higher than 1579 +**1**: higher than 1588 1588 1589 1589 if you leave logic parameter blank, it is considered 1 (higher than) 1590 1590 ))) ... ... @@ -1606,22 +1606,10 @@ 1606 1606 1607 1607 This command allows users to pre-configure specific count numbers for various counting parameters such as Count1, Count2, or AVI1 Count. Use the AT command to set the desired count number for each configuration. 1608 1608 1609 -* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) ** 1610 - 1611 -(% style="color:red" %)**aa:**(%%) 1: Set count1; 2: Set count2; 3: Set AV1 count 1612 - 1613 -(% style="color:red" %)**bb cc dd ee: **(%%)The number to be set 1614 - 1615 - 1616 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1617 - 1618 -(% style="color:blue" %)**0x A8 aa bb cc dd ee ** (%%)~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1619 - 1620 - 1621 1621 (% style="color:#037691" %)**AT Command** 1622 1622 1623 1623 (% border="2" style="width:500px" %) 1624 -|(% style="width:134px" %)**Command**|(% style="width:364px" %)AT+SETCNT=<counting_parameter><number> 1604 +|(% style="width:134px" %)**Command**|(% style="width:364px" %)AT+SETCNT=<counting_parameter>,<number> 1625 1625 |(% style="width:134px" %)**Response**|(% style="width:364px" %) 1626 1626 |(% style="width:134px" %)**Parameters**|(% style="width:364px" %)((( 1627 1627 **counting_parameter** : ... ... @@ -1667,12 +1667,6 @@ 1667 1667 1668 1668 This command clears the counting in counting mode. 1669 1669 1670 -* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+CLRCOUNT **(%%) ~/~/ clear all counting 1671 - 1672 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1673 - 1674 -(% style="color:blue" %)**0x A6 01 ** (%%)~/~/ clear all counting 1675 - 1676 1676 (% style="color:#037691" %)**AT Command** 1677 1677 1678 1678 (% border="2" style="width:500px" %) ... ... @@ -1694,20 +1694,6 @@ 1694 1694 1695 1695 This command allows you to configure the device to save its counting result to internal flash memory at specified intervals. By setting a save time, the device will periodically store the counting data to prevent loss in case of power failure. The save interval can be adjusted to suit your requirements, with a minimum value of 30 seconds. 1696 1696 1697 -* (% style="color:#037691" %)**AT Command:** 1698 - 1699 -(% style="color:blue" %)**AT+COUTIME=60 **(%%)~/~/ Sets the save time to 60 seconds. The device will save the counting result in internal flash every 60 seconds. (Min value: 30 seconds) 1700 - 1701 - 1702 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1703 - 1704 -(% style="color:blue" %)**0x A7 aa bb cc ** (%%)~/~/ same as AT+COUTIME =aa bb cc, 1705 - 1706 -((( 1707 -Range: aa bb cc:0 to 16777215, (unit: seconds) 1708 -))) 1709 - 1710 - 1711 1711 (% style="color:#037691" %)**AT Command** 1712 1712 1713 1713 (% border="2" style="width:500px" %) ... ... @@ -1739,18 +1739,8 @@ 1739 1739 1740 1740 This command allows you to reset the saved relay output (RO) and digital output (DO) states when the device joins the network. By configuring this setting, you can control whether the device should retain or reset the relay states after a reset and rejoin to the network. 1741 1741 1742 - *(% style="color:#037691" %)**AT Command:**1702 +(% style="color:#037691" %)**AT Command** 1743 1743 1744 -(% style="color:blue" %)**AT+RODORESET=1 **(%%)~/~/ RODO will close when the device joining the network. (default) 1745 - 1746 -(% style="color:blue" %)**AT+RODORESET=0 **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state will not change when the device reconnects to the network. 1747 - 1748 - 1749 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** 1750 - 1751 -(% style="color:blue" %)**0x AD aa ** (%%)~/~/ same as AT+RODORET =aa 1752 - 1753 - 1754 1754 (% border="2" style="width:500px" %) 1755 1755 |(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+RODORESET=<state> 1756 1756 |(% style="width:127px" %)**Response**|(% style="width:371px" %) ... ... @@ -1771,6 +1771,8 @@ 1771 1771 After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network. 1772 1772 ))) 1773 1773 1724 +(% style="color:#037691" %)**Downlink Payload** 1725 + 1774 1774 (% border="2" style="width:500px" %) 1775 1775 |(% style="width:127px" %)**Payload**|(% style="width:371px" %)<prefix><state> 1776 1776 |(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( ... ... @@ -1796,22 +1796,17 @@ 1796 1796 1797 1797 This command allows you to configure whether the device should upload data in an encrypted format or in plaintext. By default, the device encrypts the payload before uploading. You can toggle this setting to either upload encrypted data or transmit it without encryption. 1798 1798 1799 - *(% style="color:#037691" %)**AT Command:**1751 +(% style="color:#037691" %)**AT Command:** 1800 1800 1801 -(% style="color:blue" %)**AT+DECRYPT=1 ** (%%)~/~/ The payload is uploaded without encryption 1802 - 1803 -(% style="color:blue" %)**AT+DECRYPT=0 **(%%)~/~/ Encrypt when uploading payload (default) 1804 - 1805 - 1806 1806 (% border="2" style="width:500px" %) 1807 1807 |(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+DECRYPT=<state> 1808 1808 |(% style="width:127px" %)**Response**|(% style="width:371px" %) 1809 1809 |(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( 1810 -state : 1757 +**state** : 1811 1811 1812 -1 : The payload is uploaded without encryption 1759 +**1** : The payload is uploaded without encryption 1813 1813 1814 -0 : The payload is encrypted when uploaded (default) 1761 +**0** : The payload is encrypted when uploaded (default) 1815 1815 ))) 1816 1816 |(% style="width:127px" %)**Example**|(% style="width:371px" %)((( 1817 1817 AT+DECRYPT=1 ... ... @@ -1830,13 +1830,8 @@ 1830 1830 1831 1831 This command allows you to retrieve and optionally uplink sensor readings through the serial port. 1832 1832 1833 - *(% style="color:#037691" %)**AT Command:**1780 +(% style="color:#037691" %)**AT Command** 1834 1834 1835 -(% style="color:blue" %)**AT+GETSENSORVALUE=0 **(%%)~/~/ The serial port retrieves the reading of the current sensor. 1836 - 1837 -(% style="color:blue" %)**AT+GETSENSORVALUE=1 **(%%)~/~/ The serial port retrieves the current sensor reading and uploads it. 1838 - 1839 - 1840 1840 (% border="2" style="width:500px" %) 1841 1841 |(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+GETSENSORVALUE=<state> 1842 1842 |(% style="width:127px" %)**Response**|(% style="width:371px" %) ... ... @@ -1864,13 +1864,8 @@ 1864 1864 1865 1865 This command manages how the node handles mismatched downlink packet counts. It offers two modes: one disables the reception of further downlink packets if discrepancies occur, while the other resets the downlink packet count to align with the server, ensuring continued communication. 1866 1866 1867 - *(% style="color:#037691" %)**AT Command:**1809 +(% style="color:#037691" %)**AT Command** 1868 1868 1869 -(% style="color:blue" %)**AT+DISFCNTCHECK=0 **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1870 - 1871 -(% style="color:blue" %)**AT+DISFCNTCHECK=1 **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count. 1872 - 1873 - 1874 1874 (% border="2" style="width:500px" %) 1875 1875 |(% style="width:130px" %)**Command**|(% style="width:368px" %)AT+DISFCNTCHECK=<state> 1876 1876 |(% style="width:130px" %)**Response**|(% style="width:368px" %)((( ... ... @@ -1902,17 +1902,6 @@ 1902 1902 1903 1903 This command controls the behavior of the node when the combined size of the MAC commands (MACANS) from the server and the payload exceeds the allowed byte limit for the current data rate (DR). The command provides two modes: one enables splitting the data into batches to ensure compliance with the byte limit, while the other prioritizes the payload and ignores the MACANS in cases of overflow. 1904 1904 1905 -* (% style="color:#037691" %)**AT Command:** 1906 - 1907 -(% style="color:blue" %)**AT+DISMACANS=0** (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default) 1908 - 1909 -(% style="color:blue" %)**AT+DISMACANS=1** (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1910 - 1911 - 1912 -* (% style="color:#037691" %)**Downlink Payload **(%%)**:** 1913 - 1914 -(% style="color:blue" %)**0x21 00 01 ** (%%) ~/~/ Set the DISMACANS=1 1915 - 1916 1916 (% style="color:#037691" %)**AT Command** 1917 1917 1918 1918 (% border="2" style="width:500px" %) ... ... @@ -2026,7 +2026,7 @@ 2026 2026 The username and password (API key) you created here are required in the next section. 2027 2027 {{/info}} 2028 2028 2029 -[[image:tts-mqtt-integration.png ||height="625" width="1000"]]1955 +[[image:tts-mqtt-integration.png]] 2030 2030 2031 2031 === 3.5.2 Configuring ThingsEye.io === 2032 2032 ... ... @@ -2036,7 +2036,7 @@ 2036 2036 * Under the **Integrations center**, click **Integrations**. 2037 2037 * Click the **Add integration** button (the button with the **+** symbol). 2038 2038 2039 -[[image:thingseye-io-step-1.png ||height="625" width="1000"]]1965 +[[image:thingseye-io-step-1.png]] 2040 2040 2041 2041 2042 2042 On the **Add integration** window, configure the following: ... ... @@ -2051,7 +2051,7 @@ 2051 2051 ** Allow create devices or assets 2052 2052 * Click the **Next** button. you will be navigated to the **Uplink data converter** tab. 2053 2053 2054 -[[image:thingseye-io-step-2.png ||height="625" width="1000"]]1980 +[[image:thingseye-io-step-2.png]] 2055 2055 2056 2056 2057 2057 **Uplink data converter:** ... ... @@ -2062,7 +2062,7 @@ 2062 2062 * Paste the uplink decoder function into the text area (first, delete the default code). The demo uplink decoder function can be found [[here>>https://raw.githubusercontent.com/ThingsEye-io/te-platform/refs/heads/main/Data%20Converters/The_Things_Network_MQTT_Uplink_Converter.js]]. 2063 2063 * Click the **Next** button. You will be navigated to the **Downlink data converter **tab. 2064 2064 2065 -[[image:thingseye-io-step-3.png ||height="625" width="1000"]]1991 +[[image:thingseye-io-step-3.png]] 2066 2066 2067 2067 2068 2068 **Downlink data converter (this is an optional step):** ... ... @@ -2073,7 +2073,7 @@ 2073 2073 * Paste the downlink decoder function into the text area (first, delete the default code). The demo downlink decoder function can be found [[here>>https://raw.githubusercontent.com/ThingsEye-io/te-platform/refs/heads/main/Data%20Converters/The_Things_Network_MQTT_Downlink_Converter.js]]. 2074 2074 * Click the **Next** button. You will be navigated to the **Connection** tab. 2075 2075 2076 -[[image:thingseye-io-step-4.png ||height="625" width="1000"]]2002 +[[image:thingseye-io-step-4.png]] 2077 2077 2078 2078 2079 2079 **Connection:** ... ... @@ -2088,13 +2088,13 @@ 2088 2088 2089 2089 * Click the **Add** button. 2090 2090 2091 -[[image:thingseye-io-step-5.png ||height="625" width="1000"]]2017 +[[image:thingseye-io-step-5.png]] 2092 2092 2093 2093 2094 2094 Your integration has been added to the** Integrations** list and will be displayed on the **Integrations** page. Check whether the status is shown as **Active**. If not, review your configuration settings and correct any errors. 2095 2095 2096 2096 2097 -[[image:thingseye.io_integrationsCenter_integrations.png ||height="686" width="1000"]]2023 +[[image:thingseye.io_integrationsCenter_integrations.png]] 2098 2098 2099 2099 2100 2100 ==== 3.5.2.1 Viewing integration details ==== ... ... @@ -2101,7 +2101,7 @@ 2101 2101 2102 2102 Click on your integration from the list. The **Integration details** window will appear with the **Details **tab selected. The **Details **tab shows all the settings you have provided for this integration. 2103 2103 2104 -[[image:integration-details.png ||height="686" width="1000"]]2030 +[[image:integration-details.png]] 2105 2105 2106 2106 2107 2107 If you want to edit the settings you have provided, click on the **Toggle edit mode** button. Once you have done click on the **Apply changes **button. ... ... @@ -2117,12 +2117,12 @@ 2117 2117 * Select **Debug **from the **Event type** dropdown. 2118 2118 * Select the** time frame** from the **time window**. 2119 2119 2120 -[[image:thingseye-events.png ||height="686" width="1000"]]2046 +[[image:thingseye-events.png]] 2121 2121 2122 2122 2123 2123 * To view the **JSON payload** of a message, click on the **three dots (...)** in the Message column of the desired message. 2124 2124 2125 -[[image:thingseye-json.png ||width="1000"]]2051 +[[image:thingseye-json.png]] 2126 2126 2127 2127 2128 2128 ==== **3.5.2.3 Deleting an integration** ==== ... ... @@ -2140,7 +2140,7 @@ 2140 2140 === 3.6.1 Digital Input Ports: DI1/DI2/DI3 (For LT-33222-L, Low Active) === 2141 2141 2142 2142 2143 -Supports 2069 +Supports** NPN-type **sensors. 2144 2144 2145 2145 [[image:1653356991268-289.png]] 2146 2146 ... ... @@ -2262,15 +2262,15 @@ 2262 2262 ))) 2263 2263 2264 2264 2265 -(% style="color:blue" %)**Example4**(%%): Connecting to Dry Contact sensor 2191 +(% style="color:blue" %)**Example 4**(%%): Connecting to a Dry Contact sensor 2266 2266 2267 -From the DI port circuit above, you can see that activating the photocoupler requires a voltage difference between the DI+ and DI- ports. However, the Dry Contact sensor is a passive component and cannot provide this voltage difference.2193 +From the DI port circuit above, activating the photocoupler requires a voltage difference between the DI+ and DI- ports. However, the Dry Contact sensor is a passive component and cannot provide this voltage difference on its own. 2268 2268 2269 -To detect a Dry Contact, you can supply a power source to one pin of the Dry Contact. Belowis areference circuit diagram.2195 +To detect a Dry Contact, you can supply a power source to one of the pins of the Dry Contact. A reference circuit diagram is shown below. 2270 2270 2271 2271 [[image:image-20230616235145-1.png]] 2272 2272 2273 -(% style="color:blue" %)**Example5**(%%): Connecting to an Open Collector 2199 +(% style="color:blue" %)**Example 5**(%%): Connecting to an Open Collector 2274 2274 2275 2275 [[image:image-20240219115718-1.png]] 2276 2276 ... ... @@ -2346,7 +2346,7 @@ 2346 2346 [[image:image-20220524100215-10.png||height="382" width="723"]] 2347 2347 2348 2348 2349 -== 3.7 LED sIndicators ==2275 +== 3.7 LED Indicators == 2350 2350 2351 2351 The table below lists the behavior of LED indicators for each port function. 2352 2352 ... ... @@ -2385,13 +2385,14 @@ 2385 2385 == 4.1 Connecting the LT-22222-L to a PC == 2386 2386 2387 2387 ((( 2388 -You can use a USB-to-TTL adapter along with a 3.5mm Program Cable to connect the LT-22222-L to a PC, as shown below. 2314 +You can use a USB-to-TTL adapter/converter along with a 3.5mm Program Cable to connect the LT-22222-L to a PC, as shown below. 2389 2389 2390 -[[image:usb-ttl-programming.png]] 2316 +[[image:usb-ttl-audio-jack-connection.jpg]] 2317 + 2318 + 2391 2391 ))) 2392 2392 2393 2393 2394 - 2395 2395 ((( 2396 2396 On the PC, you need to set the (% style="color:#4f81bd" %)**serial tool **(%%)(such as [[PuTTY>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]] or [[SecureCRT>>https://www.vandyke.com/cgi-bin/releases.php?product=securecrt]]) to a baud rate of (% style="color:green" %)**9600**(%%) to access the serial console of LT-22222-L. Access to AT commands is disabled by default, and a password (default: (% style="color:green" %)**123456**)(%%) must be entered to enable AT command access, as shown below: 2397 2397 ))) ... ... @@ -2421,39 +2421,39 @@ 2421 2421 * **##AT+APPSKEY##**: Get or set the Application Session Key (AppSKey) 2422 2422 * **##AT+APPEUI##**: Get or set the Application EUI (AppEUI) 2423 2423 * **##AT+ADR##**: Get or set the Adaptive Data Rate setting. (0: OFF, 1: ON) 2424 -* AT+TXP: Get or set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Specification) 2425 -* AT+DR: Get or set the Data Rate. (0-7 corresponding to DR_X) 2426 -* AT+DCS: Get or set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 2427 -* AT+PNM: Get or set the public network mode. (0: off, 1: on) 2428 -* AT+RX2FQ: Get or set the Rx2 window frequency 2429 -* AT+RX2DR: Get or set the Rx2 window data rate (0-7 corresponding to DR_X) 2430 -* AT+RX1DL: Get or set the delay between the end of the Tx and the Rx Window 1 in ms 2431 -* AT+RX2DL: Get or set the delay between the end of the Tx and the Rx Window 2 in ms 2432 -* AT+JN1DL: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 2433 -* AT+JN2DL: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 2434 -* AT+NJM: Get or set the Network Join Mode. (0: ABP, 1: OTAA) 2435 -* AT+NWKID: Get or set the Network ID 2436 -* AT+FCU: Get or set the Frame Counter Uplink (FCntUp) 2437 -* AT+FCD: Get or set the Frame Counter Downlink (FCntDown) 2438 -* AT+CLASS: Get or set the Device Class 2439 -* AT+JOIN: Join network 2440 -* AT+NJS: Get OTAA Join Status 2441 -* AT+SENDB: Send hexadecimal data along with the application port 2442 -* AT+SEND: Send text data along with the application port 2443 -* AT+RECVB: Print last received data in binary format (with hexadecimal values) 2444 -* AT+RECV: Print last received data in raw format 2445 -* AT+VER: Get current image version and Frequency Band 2446 -* AT+CFM: Get or Set the confirmation mode (0-1) 2447 -* AT+CFS: Get confirmation status of the last AT+SEND (0-1) 2448 -* AT+SNR: Get the SNR of the last received packet 2449 -* AT+RSSI: Get the RSSI of the last received packet 2450 -* AT+TDC: Get or set the application data transmission interval in ms 2451 -* AT+PORT: Get or set the application port 2452 -* AT+DISAT: Disable AT commands 2453 -* AT+PWORD: Set password, max 9 digits 2454 -* AT+CHS: Get or set the Frequency (Unit: Hz) for Single Channel Mode 2455 -* AT+CHE: Get or set eight channels mode, Only for US915, AU915, CN470 2456 -* AT+CFG: Print all settings 2351 +* ##**AT+TXP**##: Get or set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Specification) 2352 +* **##AT+DR##**: Get or set the Data Rate. (0-7 corresponding to DR_X) 2353 +* **##AT+DCS##**: Get or set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 2354 +* ##**AT+PNM**##: Get or set the public network mode. (0: off, 1: on) 2355 +* ##**AT+RX2FQ**##: Get or set the Rx2 window frequency 2356 +* ##**AT+RX2DR**##: Get or set the Rx2 window data rate (0-7 corresponding to DR_X) 2357 +* ##**AT+RX1DL**##: Get or set the delay between the end of the Tx and the Rx Window 1 in ms 2358 +* ##**AT+RX2DL**##: Get or set the delay between the end of the Tx and the Rx Window 2 in ms 2359 +* ##**AT+JN1DL**##: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 2360 +* ##**AT+JN2DL**##: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 2361 +* ##**AT+NJM**##: Get or set the Network Join Mode. (0: ABP, 1: OTAA) 2362 +* ##**AT+NWKID**##: Get or set the Network ID 2363 +* ##**AT+FCU**##: Get or set the Frame Counter Uplink (FCntUp) 2364 +* ##**AT+FCD**##: Get or set the Frame Counter Downlink (FCntDown) 2365 +* ##**AT+CLASS**##: Get or set the Device Class 2366 +* ##**AT+JOIN**##: Join network 2367 +* ##**AT+NJS**##: Get OTAA Join Status 2368 +* ##**AT+SENDB**##: Send hexadecimal data along with the application port 2369 +* ##**AT+SEND**##: Send text data along with the application port 2370 +* ##**AT+RECVB**##: Print last received data in binary format (with hexadecimal values) 2371 +* ##**AT+RECV**##: Print last received data in raw format 2372 +* ##**AT+VER**##: Get current image version and Frequency Band 2373 +* ##**AT+CFM**##: Get or Set the confirmation mode (0-1) 2374 +* ##**AT+CFS**##: Get confirmation status of the last AT+SEND (0-1) 2375 +* ##**AT+SNR**##: Get the SNR of the last received packet 2376 +* ##**AT+RSSI**##: Get the RSSI of the last received packet 2377 +* ##**AT+TDC**##: Get or set the application data transmission interval in ms 2378 +* ##**AT+PORT**##: Get or set the application port 2379 +* ##**AT+DISAT**##: Disable AT commands 2380 +* ##**AT+PWORD**##: Set password, max 9 digits 2381 +* ##**AT+CHS**##: Get or set the Frequency (Unit: Hz) for Single Channel Mode 2382 +* ##**AT+CHE**##: Get or set eight channels mode, Only for US915, AU915, CN470 2383 +* ##**AT+CFG**##: Print all settings 2457 2457 ))) 2458 2458 2459 2459 ... ... @@ -2618,7 +2618,7 @@ 2618 2618 You will need the following things before proceeding: 2619 2619 2620 2620 * 3.5mm programming cable (included with the LT-22222-L as an additional accessory) 2621 -* USB to TTL adapter 2548 +* USB to TTL adapter/converter 2622 2622 * Download and install the [[STM32 Flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. (replaced by STM32CubeProgrammer) 2623 2623 * Download the latest firmware image from [[LT-22222-L firmware image files>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AACrbrDN0AqLHbBat0ViWx5Da/LT-22222-L/Firmware?dl=0&subfolder_nav_tracking=1]]. Check the file name of the firmware to find the correct region. 2624 2624 ... ... @@ -2628,7 +2628,7 @@ 2628 2628 2629 2629 Below is the hardware setup for uploading a firmware image to the LT-22222-L: 2630 2630 2631 -[[image:usb-ttl- programming.png]]2558 +[[image:usb-ttl-audio-jack-connection.jpg]] 2632 2632 2633 2633 2634 2634
- Screenshot 2024-11-23 at 18.27.11.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 -1 34.9KB1 +143.4 KB - Content
- lt-22222-l-joining.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +274.1 KB - Content
- usb-ttl-audio-jack-connection.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +394.4 KB - Content