Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -129,7 +129,7 @@ 129 129 * 1 x Counting Port 130 130 ))) 131 131 132 -= =2. Assembling the device ==132 += 2. Assembling the device = 133 133 134 134 == 2.1 Connecting the antenna == 135 135 ... ... @@ -882,7 +882,7 @@ 882 882 These commands are specially designed for the LT-22222-L. Commands can be sent to the device using options such as an AT command or a LoRaWAN downlink payload. 883 883 884 884 885 -==== 3.4.2.1 Set Transmit Interval ==== 885 +==== 3.4.2.1 Set Transmit/Uplink Interval ==== 886 886 887 887 Sets the uplink interval of the device. The default uplink transmission interval is 10 minutes. 888 888 ... ... @@ -891,11 +891,11 @@ 891 891 (% border="2" style="width:500px" %) 892 892 |**Command**|AT+TDC=<time> 893 893 |**Response**| 894 -|**Parameters**|**time** : uplink interval is in milliseconds 894 +|**Parameters**|**time** : uplink interval is in **milliseconds** 895 895 |**Example**|((( 896 896 AT+TDC=30000 897 897 898 -Sets the uplink interval to 30 ,000milliseconds (30 seconds)898 +Sets the uplink interval to **30 seconds** (30000 milliseconds) 899 899 ))) 900 900 901 901 (% style="color:#037691" %)**Downlink payload** ... ... @@ -907,16 +907,18 @@ 907 907 |**Parameters**|((( 908 908 **prefix** : 0x01 909 909 910 -**time** : uplink interval is in milliseconds, represented by 3 bytes in hexadecimal.910 +**time** : uplink interval is in **seconds**, represented by **3 bytes** in **hexadecimal**. 911 911 ))) 912 912 |**Example**|((( 913 -01 **00 75 30**913 +01 **00 00 1E** 914 914 915 -Sets the uplink interval to 30 ,000milliseconds(30 seconds)915 +Sets the uplink interval to **30 seconds** 916 916 917 -Conversion: 30 000(dec) = 0075 30 (hex)917 +Conversion: 30 (dec) = 00 00 1E (hex) 918 918 919 -See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30000]] 919 +See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30]] 920 + 921 +[[image:Screenshot 2024-11-23 at 18.27.11.png]] 920 920 ))) 921 921 922 922 ==== 3.4.2.2 Set the Working Mode (AT+MOD) ==== ... ... @@ -967,11 +967,11 @@ 967 967 968 968 ==== 3.4.2.3 Poll an uplink ==== 969 969 970 -Requests an uplink from LT-22222-L. 972 +Requests an uplink from LT-22222-L. The content of the uplink payload varies based on the device's current working mode. 971 971 972 972 (% style="color:#037691" %)**AT command** 973 973 974 -There is no AT Command torequestan uplinkfrom LT-22222-L976 +There is no AT Command available for this feature. 975 975 976 976 (% style="color:#037691" %)**Downlink payload** 977 977 ... ... @@ -979,7 +979,7 @@ 979 979 |(% style="width:101px" %)**Payload**|(% style="width:397px" %)<prefix>FF 980 980 |(% style="width:101px" %)**Parameters**|(% style="width:397px" %)**prefix** : 0x08 981 981 |(% style="width:101px" %)**Example**|(% style="width:397px" %)((( 982 -08 FF 984 +08 **FF** 983 983 984 984 Requests an uplink from LT-22222-L. 985 985 ))) ... ... @@ -1013,7 +1013,7 @@ 1013 1013 |(% style="width:97px" %)**Parameters**|(% style="width:401px" %)((( 1014 1014 **prefix** : 0x0A 06 (two bytes in hexadecimal) 1015 1015 1016 -** working1018 +**enable/disable trigger_mode** : enable (1) or disable (0), represented by 1 byte in hexadecimal. 1017 1017 ))) 1018 1018 |(% style="width:97px" %)**Example**|(% style="width:401px" %)((( 1019 1019 0A 06 **01** ... ... @@ -1027,7 +1027,7 @@ 1027 1027 1028 1028 (% style="color:#037691" %)**AT Command:** 1029 1029 1030 -There is no AT Command for this feature. 1032 +There is no AT Command available for this feature. 1031 1031 1032 1032 (% style="color:#037691" %)**Downlink Payload** 1033 1033 ... ... @@ -1167,8 +1167,6 @@ 1167 1167 ))) 1168 1168 |(% style="width:96px" %)**Example**|(% style="width:402px" %)09 02 **00 00 64** 1169 1169 1170 - 1171 - 1172 1172 ==== 3.4.2.9 Trigger – Set AC (current) as a trigger ==== 1173 1173 1174 1174 Sets the current trigger based on the AC port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -1350,8 +1350,6 @@ 1350 1350 ))) 1351 1351 ))) 1352 1352 1353 - 1354 - 1355 1355 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1356 1356 1357 1357 ... ... @@ -1534,17 +1534,10 @@ 1534 1534 1535 1535 When the voltage exceeds the threshold, counting begins. For details, see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1536 1536 1537 -* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+VOLMAX ** (%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1538 - 1539 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1540 - 1541 -(% style="color:blue" %)**0xA5 aa bb cc ** (%%)~/~/ Same as AT+VOLMAX=(aa bb),cc 1542 - 1543 - 1544 1544 (% style="color:#037691" %)**AT Command** 1545 1545 1546 1546 (% border="2" style="width:500px" %) 1547 -|(% style="width:137px" %)**Command**|(% style="width:361px" %)AT+VOLMAX=<voltage><logic> 1538 +|(% style="width:137px" %)**Command**|(% style="width:361px" %)AT+VOLMAX=<voltage>,<logic> 1548 1548 |(% style="width:137px" %)**Response**|(% style="width:361px" %) 1549 1549 |(% style="width:137px" %)**Parameters**|(% style="width:361px" %)((( 1550 1550 **voltage** : voltage threshold in mV ... ... @@ -1551,9 +1551,9 @@ 1551 1551 1552 1552 **logic**: 1553 1553 1554 -0 : lower than 1545 +**0** : lower than 1555 1555 1556 -1: higher than 1547 +**1**: higher than 1557 1557 1558 1558 if you leave logic parameter blank, it is considered 0 1559 1559 ))) ... ... @@ -1582,9 +1582,9 @@ 1582 1582 1583 1583 **logic**: (1 byte in hexadecimal) 1584 1584 1585 -0 : lower than 1576 +**0** : lower than 1586 1586 1587 -1: higher than 1578 +**1**: higher than 1588 1588 1589 1589 if you leave logic parameter blank, it is considered 1 (higher than) 1590 1590 ))) ... ... @@ -1606,22 +1606,10 @@ 1606 1606 1607 1607 This command allows users to pre-configure specific count numbers for various counting parameters such as Count1, Count2, or AVI1 Count. Use the AT command to set the desired count number for each configuration. 1608 1608 1609 -* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) ** 1610 - 1611 -(% style="color:red" %)**aa:**(%%) 1: Set count1; 2: Set count2; 3: Set AV1 count 1612 - 1613 -(% style="color:red" %)**bb cc dd ee: **(%%)The number to be set 1614 - 1615 - 1616 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1617 - 1618 -(% style="color:blue" %)**0x A8 aa bb cc dd ee ** (%%)~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1619 - 1620 - 1621 1621 (% style="color:#037691" %)**AT Command** 1622 1622 1623 1623 (% border="2" style="width:500px" %) 1624 -|(% style="width:134px" %)**Command**|(% style="width:364px" %)AT+SETCNT=<counting_parameter><number> 1603 +|(% style="width:134px" %)**Command**|(% style="width:364px" %)AT+SETCNT=<counting_parameter>,<number> 1625 1625 |(% style="width:134px" %)**Response**|(% style="width:364px" %) 1626 1626 |(% style="width:134px" %)**Parameters**|(% style="width:364px" %)((( 1627 1627 **counting_parameter** : ... ... @@ -1667,12 +1667,6 @@ 1667 1667 1668 1668 This command clears the counting in counting mode. 1669 1669 1670 -* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+CLRCOUNT **(%%) ~/~/ clear all counting 1671 - 1672 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1673 - 1674 -(% style="color:blue" %)**0x A6 01 ** (%%)~/~/ clear all counting 1675 - 1676 1676 (% style="color:#037691" %)**AT Command** 1677 1677 1678 1678 (% border="2" style="width:500px" %) ... ... @@ -1694,20 +1694,6 @@ 1694 1694 1695 1695 This command allows you to configure the device to save its counting result to internal flash memory at specified intervals. By setting a save time, the device will periodically store the counting data to prevent loss in case of power failure. The save interval can be adjusted to suit your requirements, with a minimum value of 30 seconds. 1696 1696 1697 -* (% style="color:#037691" %)**AT Command:** 1698 - 1699 -(% style="color:blue" %)**AT+COUTIME=60 **(%%)~/~/ Sets the save time to 60 seconds. The device will save the counting result in internal flash every 60 seconds. (Min value: 30 seconds) 1700 - 1701 - 1702 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1703 - 1704 -(% style="color:blue" %)**0x A7 aa bb cc ** (%%)~/~/ same as AT+COUTIME =aa bb cc, 1705 - 1706 -((( 1707 -Range: aa bb cc:0 to 16777215, (unit: seconds) 1708 -))) 1709 - 1710 - 1711 1711 (% style="color:#037691" %)**AT Command** 1712 1712 1713 1713 (% border="2" style="width:500px" %) ... ... @@ -1739,18 +1739,8 @@ 1739 1739 1740 1740 This command allows you to reset the saved relay output (RO) and digital output (DO) states when the device joins the network. By configuring this setting, you can control whether the device should retain or reset the relay states after a reset and rejoin to the network. 1741 1741 1742 - *(% style="color:#037691" %)**AT Command:**1701 +(% style="color:#037691" %)**AT Command** 1743 1743 1744 -(% style="color:blue" %)**AT+RODORESET=1 **(%%)~/~/ RODO will close when the device joining the network. (default) 1745 - 1746 -(% style="color:blue" %)**AT+RODORESET=0 **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state will not change when the device reconnects to the network. 1747 - 1748 - 1749 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** 1750 - 1751 -(% style="color:blue" %)**0x AD aa ** (%%)~/~/ same as AT+RODORET =aa 1752 - 1753 - 1754 1754 (% border="2" style="width:500px" %) 1755 1755 |(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+RODORESET=<state> 1756 1756 |(% style="width:127px" %)**Response**|(% style="width:371px" %) ... ... @@ -1771,6 +1771,9 @@ 1771 1771 After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network. 1772 1772 ))) 1773 1773 1723 + 1724 +(% style="color:#037691" %)**Downlink Payload** 1725 + 1774 1774 (% border="2" style="width:500px" %) 1775 1775 |(% style="width:127px" %)**Payload**|(% style="width:371px" %)<prefix><state> 1776 1776 |(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( ... ... @@ -1796,22 +1796,17 @@ 1796 1796 1797 1797 This command allows you to configure whether the device should upload data in an encrypted format or in plaintext. By default, the device encrypts the payload before uploading. You can toggle this setting to either upload encrypted data or transmit it without encryption. 1798 1798 1799 - *(% style="color:#037691" %)**AT Command:**1751 +(% style="color:#037691" %)**AT Command:** 1800 1800 1801 -(% style="color:blue" %)**AT+DECRYPT=1 ** (%%)~/~/ The payload is uploaded without encryption 1802 - 1803 -(% style="color:blue" %)**AT+DECRYPT=0 **(%%)~/~/ Encrypt when uploading payload (default) 1804 - 1805 - 1806 1806 (% border="2" style="width:500px" %) 1807 1807 |(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+DECRYPT=<state> 1808 1808 |(% style="width:127px" %)**Response**|(% style="width:371px" %) 1809 1809 |(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( 1810 -state : 1757 +**state** : 1811 1811 1812 -1 : The payload is uploaded without encryption 1759 +**1** : The payload is uploaded without encryption 1813 1813 1814 -0 : The payload is encrypted when uploaded (default) 1761 +**0** : The payload is encrypted when uploaded (default) 1815 1815 ))) 1816 1816 |(% style="width:127px" %)**Example**|(% style="width:371px" %)((( 1817 1817 AT+DECRYPT=1 ... ... @@ -1830,13 +1830,8 @@ 1830 1830 1831 1831 This command allows you to retrieve and optionally uplink sensor readings through the serial port. 1832 1832 1833 - *(% style="color:#037691" %)**AT Command:**1780 +(% style="color:#037691" %)**AT Command** 1834 1834 1835 -(% style="color:blue" %)**AT+GETSENSORVALUE=0 **(%%)~/~/ The serial port retrieves the reading of the current sensor. 1836 - 1837 -(% style="color:blue" %)**AT+GETSENSORVALUE=1 **(%%)~/~/ The serial port retrieves the current sensor reading and uploads it. 1838 - 1839 - 1840 1840 (% border="2" style="width:500px" %) 1841 1841 |(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+GETSENSORVALUE=<state> 1842 1842 |(% style="width:127px" %)**Response**|(% style="width:371px" %) ... ... @@ -1864,13 +1864,8 @@ 1864 1864 1865 1865 This command manages how the node handles mismatched downlink packet counts. It offers two modes: one disables the reception of further downlink packets if discrepancies occur, while the other resets the downlink packet count to align with the server, ensuring continued communication. 1866 1866 1867 - *(% style="color:#037691" %)**AT Command:**1809 +(% style="color:#037691" %)**AT Command** 1868 1868 1869 -(% style="color:blue" %)**AT+DISFCNTCHECK=0 **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1870 - 1871 -(% style="color:blue" %)**AT+DISFCNTCHECK=1 **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count. 1872 - 1873 - 1874 1874 (% border="2" style="width:500px" %) 1875 1875 |(% style="width:130px" %)**Command**|(% style="width:368px" %)AT+DISFCNTCHECK=<state> 1876 1876 |(% style="width:130px" %)**Response**|(% style="width:368px" %)((( ... ... @@ -1902,17 +1902,6 @@ 1902 1902 1903 1903 This command controls the behavior of the node when the combined size of the MAC commands (MACANS) from the server and the payload exceeds the allowed byte limit for the current data rate (DR). The command provides two modes: one enables splitting the data into batches to ensure compliance with the byte limit, while the other prioritizes the payload and ignores the MACANS in cases of overflow. 1904 1904 1905 -* (% style="color:#037691" %)**AT Command:** 1906 - 1907 -(% style="color:blue" %)**AT+DISMACANS=0** (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default) 1908 - 1909 -(% style="color:blue" %)**AT+DISMACANS=1** (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1910 - 1911 - 1912 -* (% style="color:#037691" %)**Downlink Payload **(%%)**:** 1913 - 1914 -(% style="color:blue" %)**0x21 00 01 ** (%%) ~/~/ Set the DISMACANS=1 1915 - 1916 1916 (% style="color:#037691" %)**AT Command** 1917 1917 1918 1918 (% border="2" style="width:500px" %)
- Screenshot 2024-11-23 at 18.27.11.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 -1 34.9KB1 +143.4 KB - Content