Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -129,7 +129,7 @@ 129 129 * 1 x Counting Port 130 130 ))) 131 131 132 -= =2. Assembling the device ==132 += 2. Assembling the device = 133 133 134 134 == 2.1 Connecting the antenna == 135 135 ... ... @@ -882,7 +882,7 @@ 882 882 These commands are specially designed for the LT-22222-L. Commands can be sent to the device using options such as an AT command or a LoRaWAN downlink payload. 883 883 884 884 885 -==== 3.4.2.1 Set Transmit Interval ==== 885 +==== 3.4.2.1 Set Transmit/Uplink Interval ==== 886 886 887 887 Sets the uplink interval of the device. The default uplink transmission interval is 10 minutes. 888 888 ... ... @@ -891,11 +891,11 @@ 891 891 (% border="2" style="width:500px" %) 892 892 |**Command**|AT+TDC=<time> 893 893 |**Response**| 894 -|**Parameters**|**time** : uplink interval is in milliseconds 894 +|**Parameters**|**time** : uplink interval is in **milliseconds** 895 895 |**Example**|((( 896 896 AT+TDC=30000 897 897 898 -Sets the uplink interval to 30 ,000milliseconds (30 seconds)898 +Sets the uplink interval to **30 seconds** (30000 milliseconds) 899 899 ))) 900 900 901 901 (% style="color:#037691" %)**Downlink payload** ... ... @@ -907,16 +907,18 @@ 907 907 |**Parameters**|((( 908 908 **prefix** : 0x01 909 909 910 -**time** : uplink interval is in milliseconds, represented by 3 bytes in hexadecimal.910 +**time** : uplink interval is in **seconds**, represented by **3 bytes** in **hexadecimal**. 911 911 ))) 912 912 |**Example**|((( 913 -01 **00 75 30**913 +01 **00 00 1E** 914 914 915 -Sets the uplink interval to 30 ,000milliseconds(30 seconds)915 +Sets the uplink interval to **30 seconds** 916 916 917 -Conversion: 30 000(dec) = 0075 30 (hex)917 +Conversion: 30 (dec) = 00 00 1E (hex) 918 918 919 -See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30000]] 919 +See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30]] 920 + 921 +[[image:Screenshot 2024-11-23 at 18.27.11.png]] 920 920 ))) 921 921 922 922 ==== 3.4.2.2 Set the Working Mode (AT+MOD) ==== ... ... @@ -1168,7 +1168,6 @@ 1168 1168 |(% style="width:96px" %)**Example**|(% style="width:402px" %)09 02 **00 00 64** 1169 1169 1170 1170 1171 - 1172 1172 ==== 3.4.2.9 Trigger – Set AC (current) as a trigger ==== 1173 1173 1174 1174 Sets the current trigger based on the AC port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -1351,7 +1351,6 @@ 1351 1351 ))) 1352 1352 1353 1353 1354 - 1355 1355 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1356 1356 1357 1357
- Screenshot 2024-11-23 at 18.27.11.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 -1 34.9KB1 +143.4 KB - Content