... ... @@ -115,23 +115,6 @@
115 115  * Smart cities
116 116  * Smart factory
117 117  
118 -== 1.5 Hardware Variants ==
119 -
120 -(% style="width:524px" %)
121 -|(% style="width:94px" %)**Model**|(% style="width:98px" %)**Photo**|(% style="width:329px" %)**Description**
122 -|(% style="width:94px" %)**LT33222-L**|(% style="width:98px" %)(((
123 -[[image:/xwiki/bin/downloadrev/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20230424115112-1.png?rev=1.1&width=58&height=106||alt="image-20230424115112-1.png" height="106" width="58"]]
124 -)))|(% style="width:329px" %)(((
125 -* 2 x Digital Input (Bi-direction)
126 -* 2 x Digital Output
127 -* 2 x Relay Output (5A@250VAC / 30VDC)
128 -* 2 x 0~~20mA Analog Input (res:0.01mA)
129 -* 2 x 0~~30V Analog Input (res:0.01v)
130 -* 1 x Counting Port
131 -)))
132 -
133 -
134 -
135 135  == 2. Assembling the device ==
136 136  
137 137  == 2.1 Connecting the antenna ==
... ... @@ -573,13 +573,13 @@
573 573  )))
574 574  
575 575  (((
576 -AT Commands for counting are similar to the [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]s.
559 +Other AT Commands for counting are similar to the [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]s.
577 577  )))
578 578  
579 579  (((
580 580  **In addition to that, below are the commands for AVI1 Counting:**
581 581  
582 -(% style="color:blue" %)**AT+SETCNT=3,60 **(%%)**(Sets AVI1 Count to 60)**
565 +(% style="color:blue" %)**AT+SETCNT=3,60 **(%%)**(Sets AVI Count to 60)**
583 583  
584 584  (% style="color:blue" %)**AT+VOLMAX=20000 **(%%)**(If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
585 585  
... ... @@ -807,9 +807,9 @@
807 807  
808 808  (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below
809 809  
810 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:674px" %)
811 -|(% style="width:64px" %)**bit 7**|(% style="width:68px" %)**bit 6**|(% style="width:63px" %)**bit 5**|(% style="width:66px" %)**bit 4**|(% style="width:109px" %)**bit 3**|(% style="width:93px" %)**bit 2**|(% style="width:109px" %)**bit 1**|(% style="width:99px" %)**bit 0**
812 -|(% style="width:64px" %)N/A|(% style="width:68px" %)N/A|(% style="width:63px" %)N/A|(% style="width:66px" %)N/A|(% style="width:109px" %)DI2_STATUS|(% style="width:93px" %)DI2_FLAG|(% style="width:109px" %)DI1_STATUS|(% style="width:99px" %)DI1_FLAG
793 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
794 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
795 +|N/A|N/A|N/A|N/A|DI2_STATUS|DI2_FLAG|DI1_STATUS|DI1_FLAG
813 813  
814 814  * Each bits shows which status has been triggered on this uplink.
815 815  
... ... @@ -994,7 +994,7 @@
994 994  (% border="2" style="width:500px" %)
995 995  |(% style="width:97px" %)**Payload**|(% style="width:401px" %)<prefix><enable/disable trigger_mode>
996 996  |(% style="width:97px" %)**Parameters**|(% style="width:401px" %)(((
997 -**prefix** : 0x0A 06 (two bytes in hexadecimal)
980 +**prefix** : 0x0A 06
998 998  
999 999  **working mode** : enable (1) or disable (0), represented by 1 byte in hexadecimal.
1000 1000  )))
... ... @@ -1014,9 +1014,9 @@
1014 1014  
1015 1015  (% style="color:#037691" %)**Downlink Payload**
1016 1016  
1017 -(% border="2" style="width:500px" %)
1000 +(% style="width:500px" %)
1018 1018  |(% style="width:95px" %)**Payload**|(% style="width:403px" %)<prefix>
1019 -|(% style="width:95px" %)**Parameters**|(% style="width:403px" %)**prefix **: AB 06 (two bytes in hexadecimal)
1002 +|(% style="width:95px" %)**Parameters**|(% style="width:403px" %)**prefix **: AB 06
1020 1020  |(% style="width:95px" %)**Example**|(% style="width:403px" %)(((
1021 1021  AB 06
1022 1022  
... ... @@ -1029,7 +1029,7 @@
1029 1029  
1030 1030  (% style="color:#037691" %)**AT Command**
1031 1031  
1032 -(% border="2" style="width:500px" %)
1015 +(% style="width:500px" %)
1033 1033  |(% style="width:98px" %)**Command**|(% style="width:400px" %)AT+DTRI=<DI1_trigger>,<DI2_trigger>
1034 1034  |(% style="width:98px" %)**Response**|(% style="width:400px" %)
1035 1035  |(% style="width:98px" %)**Parameters**|(% style="width:400px" %)(((
... ... @@ -1054,10 +1054,10 @@
1054 1054  (% class="wikigeneratedid" %)
1055 1055  (% style="color:#037691" %)**Downlink Payload**
1056 1056  
1057 -(% border="2" style="width:500px" %)
1040 +(% style="width:500px" %)
1058 1058  |(% style="width:101px" %)**Payload**|(% style="width:397px" %)<prefix><DI1_trigger><DI2_trigger>
1059 1059  |(% style="width:101px" %)**Parameters**|(% style="width:397px" %)(((
1060 -**prefix :** AA 02 (two bytes in hexadecimal)
1043 +**prefix :** AA 02
1061 1061  
1062 1062  **DI1_trigger:**
1063 1063  
... ... @@ -1081,10 +1081,23 @@
1081 1081  
1082 1082  Sets DI1 or DI3 (for LT-33222-L) as a trigger.
1083 1083  
1067 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+TRIG1=a,b**
1084 1084  
1069 +(% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
1070 +
1071 +(% style="color:red" %)**b :** (%%)delay timing.
1072 +
1073 +**Example:** AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
1074 +
1075 +
1076 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
1077 +
1078 +(% style="color:blue" %)**0x09 01 aa bb cc    ** (%%) ~/~/ same as AT+TRIG1=aa,0x(bb cc)
1079 +
1080 +
1085 1085  (% style="color:#037691" %)**AT Command**
1086 1086  
1087 -(% border="2" style="width:500px" %)
1083 +(% style="width:500px" %)
1088 1088  |(% style="width:101px" %)**Command**|(% style="width:397px" %)AT+TRIG1=<interrupt_mode>,<minimum_signal_duration>
1089 1089  |(% style="width:101px" %)**Response**|(% style="width:397px" %)
1090 1090  |(% style="width:101px" %)**Parameters**|(% style="width:397px" %)(((
... ... @@ -1104,7 +1104,7 @@
1104 1104  (% border="2" style="width:500px" %)
1105 1105  |(% style="width:101px" %)**Payload**|(% style="width:397px" %)<prefix><interrupt_mode><minimum_signal_duration>
1106 1106  |(% style="width:101px" %)**Parameters**|(% style="width:397px" %)(((
1107 -**prefix** : 09 01 (hexadecimal)
1103 +**prefix** : 09 01
1108 1108  
1109 1109  **interrupt_mode** : 0: falling edge; 1: rising edge, 2: falling and raising edge (for MOD=1), represented by 1 byte in hexadecimal.
1110 1110  
... ... @@ -1116,11 +1116,25 @@
1116 1116  Set the DI1 port to trigger on a rising edge; the valid signal duration is 100 ms.
1117 1117  )))
1118 1118  
1115 +
1119 1119  ==== 3.4.2.8 Trigger2 – Set DI2 as a trigger ====
1120 1120  
1121 1121  Sets DI2 as a trigger.
1122 1122  
1120 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+TRIG2=a,b**
1123 1123  
1122 +(% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge (for MOD=1).
1123 +
1124 +(% style="color:red" %)**b :** (%%)delay timing.
1125 +
1126 +**Example:** AT+TRIG2=0,100 (Set the DI1 port to trigger on a falling edge; the valid signal duration is 100 ms)
1127 +
1128 +
1129 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**
1130 +
1131 +(% style="color:blue" %)**0x09 02 aa bb cc   ** (%%)~/~/ same as AT+TRIG2=aa,0x(bb cc)
1132 +
1133 +
1124 1124  (% style="color:#037691" %)**AT Command**
1125 1125  
1126 1126  (% border="2" style="width:500px" %)
... ... @@ -1142,7 +1142,7 @@
1142 1142  (% border="2" style="width:500px" %)
1143 1143  |(% style="width:96px" %)**Payload**|(% style="width:402px" %)<prefix><interrupt_mode><minimum_signal_duration>
1144 1144  |(% style="width:96px" %)**Parameters**|(% style="width:402px" %)(((
1145 -**prefix** : 09 02 (hexadecimal)
1155 +**prefix** : 09 02
1146 1146  
1147 1147  **interrupt_mode **: 0: falling edge; 1: rising edge, 2: falling and raising edge (for MOD=1), represented by 1 byte in hexadecimal.
1148 1148  
... ... @@ -1150,170 +1150,94 @@
1150 1150  )))
1151 1151  |(% style="width:96px" %)**Example**|(% style="width:402px" %)09 02 **00 00 64**
1152 1152  
1153 -==== ====
1154 -
1155 1155  ==== 3.4.2.9 Trigger – Set AC (current) as a trigger ====
1156 1156  
1157 -Sets the current trigger based on the AC port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1165 +Sets the current trigger based on the AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1158 1158  
1159 -(% style="color:#037691" %)**AT Command**
1167 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+ACLIM**
1160 1160  
1169 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )**
1170 +
1171 +(% style="color:blue" %)**0x AA 01 aa bb cc dd ee ff gg hh        ** (%%) ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1172 +
1173 +
1161 1161  (% border="2" style="width:500px" %)
1162 1162  |(% style="width:104px" %)**Command**|(% style="width:394px" %)(((
1163 1163  AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
1164 1164  )))
1165 1165  |(% style="width:104px" %)**Response**|(% style="width:394px" %)
1166 -|(% style="width:104px" %)**Parameters**|(% style="width:394px" %)(((
1167 -**AC1_LIMIT_LOW** : lower limit of the current to be checked
1168 -
1169 -**AC1_LIMIT_HIGH **: higher limit of the current to be checked
1170 -
1171 -**AC2_LIMIT_HIGH **: lower limit of the current to be checked
1172 -
1173 -**AC2_LIMIT_LOW** : higher limit of the current to be checked
1174 -)))
1179 +|(% style="width:104px" %)**Parameters**|(% style="width:394px" %)-
1175 1175  |(% style="width:104px" %)**Example**|(% style="width:394px" %)(((
1176 1176  AT+ACLIM=10000,15000,0,0
1177 1177  
1178 1178  Triggers an uplink if AC1 current is lower than 10mA or higher than 15mA
1179 1179  )))
1180 -|(% style="width:104px" %)Note|(% style="width:394px" %)See also, [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1181 1181  
1182 -(% style="color:#037691" %)**Downlink Payload**
1183 -
1184 1184  (% border="2" style="width:500px" %)
1185 1185  |(% style="width:104px" %)**Payload**|(% style="width:394px" %)<prefix><AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
1186 1186  |(% style="width:104px" %)**Parameters**|(% style="width:394px" %)(((
1187 -**prefix **: AA 01 (hexadecimal)
1189 +**prefix **: AA 01 - two bytes in hexadecimal
1188 1188  
1189 -**AC1_LIMIT_LOW** : lower limit of the current to be checked, two bytes in hexadecimal
1191 +**AC1_LIMIT_LOW** : lower limit of the current to be checked / threshold, two bytes in hexadecimal
1190 1190  
1191 -**AC1_LIMIT_HIGH **: higher limit of the current to be checked, two bytes in hexadecimal
1193 +**AC1_LIMIT_HIGH **: higher limit of the current to be checked / threshold, two bytes in hexadecimal
1192 1192  
1193 -**AC2_LIMIT_HIGH **: lower limit of the current to be checked, two bytes in hexadecimal
1195 +**AC2_LIMIT_HIGH **: lower limit of the current to be checked / threshold, two bytes in hexadecimal
1194 1194  
1195 -**AC2_LIMIT_LOW** : higher limit of the current to be checked, two bytes in hexadecimal
1197 +**AC2_LIMIT_HIGH** : higher limit of the current to be checked / threshold, two bytes in hexadecimal
1196 1196  )))
1197 1197  |(% style="width:104px" %)**Example**|(% style="width:394px" %)(((
1198 -AA 01 **27** **10 3A** **98** 00 00 00 00
1200 +AA 01 27 10 3A 98 00 00 00 00
1199 1199  
1200 -Triggers an uplink if AC1 current is lower than 10mA or higher than 15mA. Set all values to zero for AC2 limits because we are only checking AC1 limits.
1202 +Triggers an uplink if AC1 current is lower than 10mA or higher than 15mA
1201 1201  )))
1202 -|(% style="width:104px" %)Note|(% style="width:394px" %)See also, [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1203 1203  
1204 1204  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
1205 1205  
1206 -Sets the current trigger based on the AV port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1207 +Sets the current trigger based on the AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1207 1207  
1208 -(% style="color:#037691" %)**AT Command**
1209 +* (% style="color:#037691" %)**AT Command**(%%): (% style="color:blue" %)**AT+AVLIM    **(%%)** See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
1209 1209  
1210 -(% border="2" style="width:500px" %)
1211 -|(% style="width:104px" %)**Command**|(% style="width:387px" %)AT+AVLIM= AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH>
1212 -|(% style="width:104px" %)**Response**|(% style="width:387px" %)
1213 -|(% style="width:104px" %)**Parameters**|(% style="width:387px" %)(((
1214 -**AC1_LIMIT_LOW** : lower limit of the current to be checked
1211 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )**
1215 1215  
1216 -**AC1_LIMIT_HIGH **: higher limit of the current to be checked
1213 +(% style="color:blue" %)**0x AA 00 aa bb cc dd ee ff gg hh    ** (%%) ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1217 1217  
1218 -**AC2_LIMIT_HIGH **: lower limit of the current to be checked
1219 1219  
1220 -**AC2_LIMIT_LOW** : higher limit of the current to be checked
1221 -)))
1222 -|(% style="width:104px" %)**Example**|(% style="width:387px" %)(((
1223 -AT+AVLIM=3000,6000,0,2000
1224 -
1225 -Triggers an uplink if AVI1 voltage is lower than 3V or higher than 6V, or if AV2 voltage is higher than 2V
1226 -)))
1227 -|(% style="width:104px" %)**Note**|(% style="width:387px" %)See also, [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1228 -
1229 -(% style="color:#037691" %)**Downlink Payload**
1230 -
1231 -(% border="2" style="width:500px" %)
1232 -|(% style="width:104px" %)**Payload**|(% style="width:394px" %)<prefix><AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH>
1233 -|(% style="width:104px" %)**Parameters**|(% style="width:394px" %)(((
1234 -**prefix **: AA 00 (hexadecimal)
1235 -
1236 -**AV1_LIMIT_LOW** : lower limit of the voltage to be checked, two bytes in hexadecimal
1237 -
1238 -**AV1_LIMIT_HIGH **: higher limit of the voltage to be checked, two bytes in hexadecimal
1239 -
1240 -**AV2_LIMIT_HIGH **: lower limit of the voltage to be checked, two bytes in hexadecimal
1241 -
1242 -**AV2_LIMIT_LOW** : higher limit of the voltage to be checked, two bytes in hexadecimal
1243 -)))
1244 -|(% style="width:104px" %)**Example**|(% style="width:394px" %)(((
1245 -AA 00 **0B B8 17 70 00 00 07 D0**
1246 -
1247 -Triggers an uplink if AVI1 voltage is lower than 3V or higher than 6V, or if AV2 voltage is higher than 2V.
1248 -)))
1249 -|(% style="width:104px" %)**Note**|(% style="width:394px" %)See also, [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1250 -
1251 1251  ==== 3.4.2.11 Trigger – Set minimum interval ====
1252 1252  
1253 -Sets the AV and AC trigger minimum interval. The device won't respond to a second trigger within this set time after the first trigger.
1218 +Sets AV and AC trigger minimum interval. Device won't response to the second trigger within this set time after the first trigger.
1254 1254  
1255 -(% style="color:#037691" %)**AT Command**
1220 +* (% style="color:#037691" %)**AT Command**(%%): (% style="color:blue" %)**AT+ATDC=5        ** ~/~/ (%%)Device won't response the second trigger within 5 minute after the first trigger.
1256 1256  
1257 -(% border="2" style="width:500px" %)
1258 -|(% style="width:113px" %)**Command**|(% style="width:385px" %)AT+ATDC=<time>
1259 -|(% style="width:113px" %)**Response**|(% style="width:385px" %)
1260 -|(% style="width:113px" %)**Parameters**|(% style="width:385px" %)(((
1261 -**time** : in minutes
1262 -)))
1263 -|(% style="width:113px" %)**Example**|(% style="width:385px" %)(((
1264 -AT+ATDC=5
1222 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
1265 1265  
1266 -The device won't respond to the second trigger within 5 minutes after the first trigger.
1267 -)))
1268 -|(% style="width:113px" %)Note|(% style="width:385px" %)(% style="color:red" %)**The time must be greater than 5 minutes.**
1224 +(% style="color:blue" %)**0x AC aa bb   **(%%) ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
1269 1269  
1270 -(% style="color:#037691" %)**Downlink Payload**
1271 -
1272 -(% border="2" style="width:500px" %)
1273 -|(% style="width:112px" %)**Payload**|(% style="width:386px" %)<prefix><time>
1274 -|(% style="width:112px" %)**Parameters**|(% style="width:386px" %)(((
1275 -**prefix** : AC (hexadecimal)
1276 -
1277 -**time **: in minutes (two bytes in hexadecimal)
1226 +(((
1227 +(% style="color:red" %)**Note: ATDC setting must be more than 5min**
1278 1278  )))
1279 -|(% style="width:112px" %)**Example**|(% style="width:386px" %)(((
1280 -AC **00 05**
1281 1281  
1282 -The device won't respond to the second trigger within 5 minutes after the first trigger.
1283 -)))
1284 -|(% style="width:112px" %)Note|(% style="width:386px" %)(% style="color:red" %)**The time must be greater than 5 minutes.**
1285 1285  
1231 +
1286 1286  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
1287 1287  
1288 1288  Controls the digital outputs DO1, DO2, and DO3
1289 1289  
1290 -(% style="color:#037691" %)**AT Command**
1236 +* (% style="color:#037691" %)**AT Command**
1291 1291  
1292 -There is no AT Command to control the Digital Output.
1238 +There is no AT Command to control Digital Output
1293 1293  
1294 1294  
1295 -(% style="color:#037691" %)**Downlink Payload**
1241 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)**
1296 1296  
1297 -(% border="2" style="width:500px" %)
1298 -|(% style="width:115px" %)**Payload**|(% style="width:383px" %)<prefix><DO1><DO2><DO3>
1299 -|(% style="width:115px" %)**Parameters**|(% style="width:383px" %)(((
1300 -**prefix** : 02 (hexadecimal)
1243 +(% style="color:blue" %)**0x02 aa bb cc     ** (%%)~/~/ Set DO1/DO2/DO3 output
1301 1301  
1302 -**DOI** : 01: Low,  00: High, 11: No action (1 byte in hex)
1303 -
1304 -**DO2** : 01: Low,  00: High, 11: No action (1 byte in hex)
1305 -
1306 -**DO3 **: 01: Low,  00: High, 11: No action (1 byte in hex)
1245 +(((
1246 +If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low.
1307 1307  )))
1308 -|(% style="width:115px" %)**Examples**|(% style="width:383px" %)(((
1309 -02 **01 00 01**
1310 1310  
1311 -If there is a load between V+ and DOx, it means DO1 is set to low, DO2 is set to high, and DO3 is set to low.
1312 -
1313 -**More examples:**
1314 -
1315 1315  (((
1316 -01: Low,  00: High,  11: No action
1250 +01: Low,  00: High ,  11: No action
1317 1317  
1318 1318  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1319 1319  |(% style="background-color:#4f81bd; color:white" %)**Downlink Code**|(% style="background-color:#4f81bd; color:white" %)**DO1**|(% style="background-color:#4f81bd; color:white" %)**DO2**|(% style="background-color:#4f81bd; color:white" %)**DO3**
... ... @@ -1323,18 +1323,15 @@
1323 1323  )))
1324 1324  
1325 1325  (((
1326 -(((
1327 -(% style="color:red" %)**Note: For the LT-22222-L, there is no DO3; the last byte can have any value.**
1260 +(% style="color:red" %)**Note: For LT-22222-L, there is no DO3, the last byte can use any value.**
1328 1328  )))
1329 1329  
1330 1330  (((
1331 -(% style="color:red" %)**The device will upload a packet if downlink code executes successfully.**
1264 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1332 1332  )))
1333 -)))
1334 -)))
1335 1335  
1336 -==== ====
1337 1337  
1268 +
1338 1338  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
1339 1339  
1340 1340  
... ... @@ -1359,7 +1359,7 @@
1359 1359  00: DO pins will change to an inverter state after timeout 
1360 1360  
1361 1361  
1362 -(% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Port status:
1293 +(% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1363 1363  
1364 1364  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1365 1365  |(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status**
... ... @@ -1367,7 +1367,7 @@
1367 1367  |0x00|DO1 set to high
1368 1368  |0x11|DO1 NO Action
1369 1369  
1370 -(% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Port status:
1301 +(% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1371 1371  
1372 1372  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1373 1373  |(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status**
... ... @@ -1375,7 +1375,7 @@
1375 1375  |0x00|DO2 set to high
1376 1376  |0x11|DO2 NO Action
1377 1377  
1378 -(% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Port status:
1309 +(% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1379 1379  
1380 1380  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1381 1381  |(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status**
... ... @@ -1383,16 +1383,16 @@
1383 1383  |0x00|DO3 set to high
1384 1384  |0x11|DO3 NO Action
1385 1385  
1386 -(% style="color:#4f81bd" %)**Sixth, Seventh, Eighth, and Ninth Bytes**:(%%) Latching time (Unit: ms)
1317 +(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**:(%%) Latching time. Unit: ms
1387 1387  
1388 1388  
1389 1389  (% style="color:red" %)**Note: **
1390 1390  
1391 - Since firmware v1.6.0, the latch time support 4 bytes and 2 bytes
1322 + Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes
1392 1392  
1393 - Before firmware v1.6.0, the latch time only supported 2 bytes.
1324 + Before Firmwre v1.6.0 the latch time only suport 2 bytes.
1394 1394  
1395 -(% style="color:red" %)**Device will upload a packet if the downlink code executes successfully.**
1326 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1396 1396  
1397 1397  
1398 1398  **Example payload:**
... ... @@ -1399,21 +1399,22 @@
1399 1399  
1400 1400  **~1. A9 01 01 01 01 07 D0**
1401 1401  
1402 -DO1 pin, DO2 pin, and DO3 pin will be set to low, last for 2 seconds, and then revert to their original state.
1333 +DO1 pin & DO2 pin & DO3 pin will be set to Low, last 2 seconds, then change back to original state.
1403 1403  
1404 1404  **2. A9 01 00 01 11 07 D0**
1405 1405  
1406 -DO1 pin is set to high, DO2 pin is set to low, and DO3 pin takes no action. This lasts for 2 seconds and then reverts to the original state.
1337 +DO1 pin set high, DO2 pin set low, DO3 pin no action, last 2 seconds, then change back to original state.
1407 1407  
1408 1408  **3. A9 00 00 00 00 07 D0**
1409 1409  
1410 -DO1 pin, DO2 pin, and DO3 pin will be set to high, last for 2 seconds, and then all change to low.
1341 +DO1 pin & DO2 pin & DO3 pin will be set to high, last 2 seconds, then both change to low.
1411 1411  
1412 1412  **4. A9 00 11 01 00 07 D0**
1413 1413  
1414 -DO1 pin takes no action, DO2 pin is set to low, and DO3 pin is set to high. This lasts for 2 seconds, after which DO1 pin takes no action, DO2 pin is set to high, and DO3 pin is set to low.
1345 +DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low
1415 1415  
1416 1416  
1348 +
1417 1417  ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1418 1418  
1419 1419  
... ... @@ -1428,11 +1428,11 @@
1428 1428  
1429 1429  
1430 1430  (((
1431 -If payload is 0x030100, it means setting RO1 to close and RO2 to open.
1363 +If payload = 0x030100, it means set RO1 to close and RO2 to open.
1432 1432  )))
1433 1433  
1434 1434  (((
1435 -00: Close ,  01: Open , 11: No action
1367 +00: Closed ,  01: Open , 11: No action
1436 1436  
1437 1437  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:320px" %)
1438 1438  |(% style="background-color:#4f81bd; color:white" %)**Downlink Code**|(% style="background-color:#4f81bd; color:white" %)**RO1**|(% style="background-color:#4f81bd; color:white" %)**RO2**
... ... @@ -1449,9 +1449,9 @@
1449 1449  (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1450 1450  
1451 1451  
1384 +
1452 1452  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1453 1453  
1454 -Controls the relay output time.
1455 1455  
1456 1456  * (% style="color:#037691" %)**AT Command:**
1457 1457  
... ... @@ -1463,15 +1463,15 @@
1463 1463  (% style="color:blue" %)**0x05 aa bb cc dd     ** (%%)~/~/ Set RO1/RO2 relay with time control
1464 1464  
1465 1465  
1466 -This is to control the relay output time. It includes four bytes:
1398 +This is to control the relay output time of relay. Include four bytes:
1467 1467  
1468 1468  (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05)
1469 1469  
1470 1470  (% style="color:#4f81bd" %)**Second Byte(aa)**(%%): Inverter Mode
1471 1471  
1472 -01: Relays will change back to their original state after timeout.
1404 +01: Relays will change back to original state after timeout.
1473 1473  
1474 -00: Relays will change to the inverter state after timeout.
1406 +00: Relays will change to an inverter state after timeout
1475 1475  
1476 1476  
1477 1477  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
... ... @@ -1484,12 +1484,12 @@
1484 1484  
1485 1485  (% style="color:red" %)**Note:**
1486 1486  
1487 - Since firmware v1.6.0, the latch time supports both 4 bytes and 2 bytes.
1419 + Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes
1488 1488  
1489 - Before firmware v1.6.0, the latch time only supported 2 bytes.
1421 + Before Firmwre v1.6.0 the latch time only suport 2 bytes.
1490 1490  
1491 1491  
1492 -(% style="color:red" %)**Device will upload a packet if the downlink code executes successfully.**
1424 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1493 1493  
1494 1494  
1495 1495  **Example payload:**
... ... @@ -1496,19 +1496,19 @@
1496 1496  
1497 1497  **~1. 05 01 11 07 D0**
1498 1498  
1499 -Relay1 and Relay2 will be set to NC, lasting 2 seconds, then revert to their original state
1431 +Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state.
1500 1500  
1501 1501  **2. 05 01 10 07 D0**
1502 1502  
1503 -Relay1 will change to NC, Relay2 will change to NO, lasting 2 seconds, then both will revert to their original state.
1435 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then both change back to original state.
1504 1504  
1505 1505  **3. 05 00 01 07 D0**
1506 1506  
1507 -Relay1 will change to NO, Relay2 will change to NC, lasting 2 seconds, then Relay1 will change to NC, and Relay2 will change to NO.
1439 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO.
1508 1508  
1509 1509  **4. 05 00 00 07 D0**
1510 1510  
1511 -Relay1 and Relay2 will change to NO, lasting 2 seconds, then both will change to NC.
1443 +Relay 1 & relay2 will change to NO, last 2 seconds, then both change to NC.
1512 1512  
1513 1513  
1514 1514  
... ... @@ -1515,7 +1515,7 @@
1515 1515  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1516 1516  
1517 1517  
1518 -When the voltage exceeds the threshold, counting begins. For details, see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1450 +When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1519 1519  
1520 1520  * (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+VOLMAX   ** (%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1521 1521  
... ... @@ -1524,76 +1524,15 @@
1524 1524  (% style="color:blue" %)**0xA5 aa bb cc   ** (%%)~/~/ Same as AT+VOLMAX=(aa bb),cc
1525 1525  
1526 1526  
1527 -(% style="color:#037691" %)**AT Command**
1528 1528  
1529 -(% border="2" style="width:500px" %)
1530 -|(% style="width:137px" %)**Command**|(% style="width:361px" %)AT+VOLMAX=<voltage><logic>
1531 -|(% style="width:137px" %)**Response**|(% style="width:361px" %)
1532 -|(% style="width:137px" %)**Parameters**|(% style="width:361px" %)(((
1533 -**voltage** : voltage threshold in mV
1534 -
1535 -**logic**:
1536 -
1537 -0 : lower than
1538 -
1539 -1: higher than
1540 -
1541 -if you leave logic parameter blank, it is considered 0
1542 -)))
1543 -|(% style="width:137px" %)**Examples**|(% style="width:361px" %)(((
1544 -AT+VOLMAX=20000
1545 -
1546 -If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1
1547 -
1548 -AT+VOLMAX=20000,0
1549 -
1550 -If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1
1551 -
1552 -AT+VOLMAX=20000,1
1553 -
1554 -If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1
1555 -)))
1556 -
1557 -(% style="color:#037691" %)**Downlink Payload**
1558 -
1559 -(% border="2" style="width:500px" %)
1560 -|(% style="width:140px" %)**Payload**|(% style="width:358px" %)<prefix><voltage><logic>
1561 -|(% style="width:140px" %)**Parameters**|(% style="width:358px" %)(((
1562 -**prefix** : A5 (hex)
1563 -
1564 -**voltage** : voltage threshold in mV (2 bytes in hex)
1565 -
1566 -**logic**: (1 byte in hexadecimal)
1567 -
1568 -0 : lower than
1569 -
1570 -1: higher than
1571 -
1572 -if you leave logic parameter blank, it is considered 1 (higher than)
1573 -)))
1574 -|(% style="width:140px" %)**Example**|(% style="width:358px" %)(((
1575 -A5 **4E 20**
1576 -
1577 -If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1
1578 -
1579 -A5 **4E 20 00**
1580 -
1581 -If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1
1582 -
1583 -A5 **4E 20 01**
1584 -
1585 -If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1
1586 -)))
1587 -
1588 1588  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1589 1589  
1590 -This feature allows users to pre-configure specific count numbers for various counting parameters such as Count1, Count2, or AVI1 Count. Use the AT command to set the desired count number for each configuration.
1591 1591  
1592 1592  * (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) **
1593 1593  
1594 1594  (% style="color:red" %)**aa:**(%%) 1: Set count1; 2: Set count2; 3: Set AV1 count
1595 1595  
1596 -(% style="color:red" %)**bb cc dd ee: **(%%)The number to be set
1467 +(% style="color:red" %)**bb cc dd ee: **(%%)number to be set
1597 1597  
1598 1598  
1599 1599  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):**
... ... @@ -1601,55 +1601,12 @@
1601 1601  (% style="color:blue" %)**0x A8 aa bb cc dd ee     ** (%%)~/~/ same as AT+SETCNT=aa,(bb cc dd ee)
1602 1602  
1603 1603  
1604 -(% style="color:#037691" %)**AT Command**
1605 1605  
1606 -(% border="2" style="width:500px" %)
1607 -|(% style="width:134px" %)**Command**|(% style="width:364px" %)AT+SETCNT=<counting_parameter><number>
1608 -|(% style="width:134px" %)**Response**|(% style="width:364px" %)
1609 -|(% style="width:134px" %)**Parameters**|(% style="width:364px" %)(((
1610 -**counting_parameter** :
1611 -
1612 -1: COUNT1
1613 -
1614 -2: COUNT2
1615 -
1616 -3: AVI1 Count
1617 -
1618 -**number** : Start number
1619 -)))
1620 -|(% style="width:134px" %)**Example**|(% style="width:364px" %)(((
1621 -AT+SETCNT=1,10
1622 -
1623 -Sets the COUNT1 to 10.
1624 -)))
1625 -
1626 -(% style="color:#037691" %)**Downlink Payload**
1627 -
1628 -(% border="2" style="width:500px" %)
1629 -|(% style="width:135px" %)**Payload**|(% style="width:363px" %)<prefix><counting_parameter><number>
1630 -|(% style="width:135px" %)**Parameters**|(% style="width:363px" %)(((
1631 -prefix : A8 (hex)
1632 -
1633 -**counting_parameter** : (1 byte in hexadecimal)
1634 -
1635 -1: COUNT1
1636 -
1637 -2: COUNT2
1638 -
1639 -3: AVI1 Count
1640 -
1641 -**number** : Start number, 4 bytes in hexadecimal
1642 -)))
1643 -|(% style="width:135px" %)**Example**|(% style="width:363px" %)(((
1644 -A8 **01 00 00 00 0A**
1645 -
1646 -Sets the COUNT1 to 10.
1647 -)))
1648 -
1649 1649  ==== 3.4.2.18 Counting ~-~- Clear Counting ====
1650 1650  
1651 -This feature clears the counting in counting mode.
1652 1652  
1479 +Clear counting for counting mode
1480 +
1653 1653  * (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+CLRCOUNT         **(%%) ~/~/ clear all counting
1654 1654  
1655 1655  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
... ... @@ -1656,30 +1656,14 @@
1656 1656  
1657 1657  (% style="color:blue" %)**0x A6 01    ** (%%)~/~/ clear all counting
1658 1658  
1659 -(% style="color:#037691" %)**AT Command**
1660 1660  
1661 -(% border="2" style="width:500px" %)
1662 -|(% style="width:142px" %)**Command**|(% style="width:356px" %)AT+CLRCOUNT
1663 -|(% style="width:142px" %)**Response**|(% style="width:356px" %)-
1664 1664  
1665 -(% style="color:#037691" %)**Downlink Payload**
1666 -
1667 -(% border="2" style="width:500px" %)
1668 -|(% style="width:141px" %)**Payload**|(% style="width:357px" %)<prefix><clear?>
1669 -|(% style="width:141px" %)**Parameters**|(% style="width:357px" %)(((
1670 -prefix : A6 (hex)
1671 -
1672 -clear? : 01 (hex)
1673 -)))
1674 -|(% style="width:141px" %)**Example**|(% style="width:357px" %)A6 **01**
1675 -
1676 1676  ==== 3.4.2.19 Counting ~-~- Change counting mode to save time ====
1677 1677  
1678 -This feature allows you to configure the device to save its counting result to internal flash memory at specified intervals. By setting a save time, the device will periodically store the counting data to prevent loss in case of power failure. The save interval can be adjusted to suit your requirements, with a minimum value of 30 seconds.
1679 1679  
1680 1680  * (% style="color:#037691" %)**AT Command:**
1681 1681  
1682 -(% style="color:blue" %)**AT+COUTIME=60  **(%%)~/~/ Sets the save time to 60 seconds. The device will save the counting result in internal flash every 60 seconds. (Min value: 30 seconds)
1494 +(% style="color:blue" %)**AT+COUTIME=60  **(%%)~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)
1683 1683  
1684 1684  
1685 1685  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):**
... ... @@ -1687,7 +1687,7 @@
1687 1687  (% style="color:blue" %)**0x A7 aa bb cc     ** (%%)~/~/ same as AT+COUTIME =aa bb cc,
1688 1688  
1689 1689  (((
1690 -Range: aa bb cc:0 to 16777215,  (unit: seconds)
1502 +range: aa bb cc:0 to 16777215,  (unit:second)
1691 1691  )))
1692 1692  
1693 1693  
... ... @@ -1694,13 +1694,12 @@
1694 1694  
1695 1695  ==== 3.4.2.20 Reset save RO DO state ====
1696 1696  
1697 -This feature allows you to reset the saved relay output (RO) and digital output (DO) states when the device joins the network. By configuring this setting, you can control whether the device should retain or reset the relay states after a reset and rejoin to the network.
1698 1698  
1699 1699  * (% style="color:#037691" %)**AT Command:**
1700 1700  
1701 1701  (% style="color:blue" %)**AT+RODORESET=1    **(%%)~/~/ RODO will close when the device joining the network. (default)
1702 1702  
1703 -(% style="color:blue" %)**AT+RODORESET=0    **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state will not change when the device reconnects to the network.
1514 +(% style="color:blue" %)**AT+RODORESET=0    **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network.
1704 1704  
1705 1705  
1706 1706  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):**
... ... @@ -1711,7 +1711,6 @@
1711 1711  
1712 1712  ==== 3.4.2.21 Encrypted payload ====
1713 1713  
1714 -This feature allows you to configure whether the device should upload data in an encrypted format or in plaintext. By default, the device encrypts the payload before uploading. You can toggle this setting to either upload encrypted data or transmit it without encryption.
1715 1715  
1716 1716  * (% style="color:#037691" %)**AT Command:**
1717 1717  
... ... @@ -1726,9 +1726,9 @@
1726 1726  
1727 1727  * (% style="color:#037691" %)**AT Command:**
1728 1728  
1729 -(% style="color:blue" %)**AT+GETSENSORVALUE=0    **(%%)~/~/ The serial port retrieves the reading of the current sensor.
1539 +(% style="color:blue" %)**AT+GETSENSORVALUE=0    **(%%)~/~/ The serial port gets the reading of the current sensor
1730 1730  
1731 -(% style="color:blue" %)**AT+GETSENSORVALUE=1    **(%%)~/~/ The serial port retrieves the current sensor reading and uploads it.
1541 +(% style="color:blue" %)**AT+GETSENSORVALUE=1    **(%%)~/~/ The serial port gets the current sensor reading and uploads it.
1732 1732  
1733 1733  
1734 1734  
... ... @@ -1918,7 +1918,7 @@
1918 1918  
1919 1919  == 3.6 Interface Details ==
1920 1920  
1921 -=== 3.6.1 Digital Input Ports: DI1/DI2/DI3 (For LT-33222-L, Low Active) ===
1731 +=== 3.6.1 Digital Input Ports: DI1/DI2/DI3 (For LT-33222-L, Low Active ) ===
1922 1922  
1923 1923  
1924 1924  Supports NPN-type sensors.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved